摘要 各国规范中对钢管混凝土构件截面刚度的定义存在着差异,钢管混凝土截面刚度的取值对钢管混凝土拱内力、变形和稳定计算均有影响。本文以1座实桥的实测资料为基础,对现有钢管混凝土截面刚度的不同算法进行了比较分析,得出了一些有益的结论,可供工程实践参考。 There are some differences in the definition of the rigidity of CFST component between the codes of different countries.These differences influence the internal force,deform,stability of CFST arch.Comparing with the results of the testing of a real bridge,the calculation for it by using the different rigidity definitions of the CFST component was carried out in this paper.Some useful conclusions were deduced and it will be of help for the design of this kind of bridge.
出处 《公路交通科技》 CAS CSCD 北大核心 2004年第11期47-51,共5页 Journal of Highway and Transportation Research and Development
基金 福建省重大科技项目(2003F007) 福建省教育厅科技项目(JA03016)
关键词 钢管混凝土 刚度 Concrete filled steel tube Arch Rigidity
  • 相关文献

参考文献3

  • 1AISC.Load and Resistance Factor Design Specification for Structural Steel Buildings,Chapter one[S].1986.
  • 2British Standards Institute,BS5400,Part 5.Concrete and Composite Bridges[S].1979.
  • 3Architectural Institute of Japan (AIJ).Recommendations for Design and Construction of Concrete Filled Tubular Structures[S].Japan,1997.