摘要 目的 了解正常听力成人同时多频听觉稳态诱发反应的特性。方法  32名受试者 (6 4耳 ) ,年龄 2 2~ 32岁 ,平均 2 8.3岁 ,男 12名 ,女 2 0名 ,双耳纯音听阈测试各频率听阈在 2 0dB以内。以载波频率为 0 .5、1、2和 4kHz的纯音 ,调制频率分别为 77、85、93和 10 1Hz(左耳 )以及 79、87、95、10 3Hz(右耳 )的调幅声作为测试信号 ,双耳 8个频率同时给声刺激 ,同时自动判定并记录反应。各载波频率的阈值、反应幅度等数据采用SPSS统计软件分析。结果 ①同时多频听觉稳态诱发反应阈高于纯音听阈 7~ 19dB。②反应阈经双因素方差分析 (侧别×频率 ) ,左右耳之间无显著性差异 (F =1.94 2 ;μ 1,179;P =0 .16 5 ) ,但各频率之间有显著性差异 (F =31.2 5 4 ;μ 3,179;P =0 .0 0 0 ) ,各频率反应阈均值之间进一步的两两比较显示 0 .5kHz反应阈与其它频率之间存在显著性差异。③以 6 0dBSPL作为分析强度 ,男女受试者在各个频率的反应幅度的差异经双因素方差分析 (性别×频率 )有显著性差异 (F =2 .94 8;μ 3,175 ;P =0 .0 34) ,0 .5kHz反应幅度最低 ,4kHz最高。性别之间有显著性差异 (F =16 .4 90 ;μ 1,175 ;P=0 .0 0 0 ) ,男性反应幅度高于女性。④各频率不同状态下背景噪声的差异经双因素方差分析 ,提示清醒状? Objective To explore some characters of auditory steady-state responses (ASSR) to multiple simultaneous stimuli in a sample of normal-hearing adults.Methods The ASSR to multiple simultaneous stimuli were recorded in a sample of 32 normal-hearing adults (64 ears). Simultaneous carrier tones (0.5, 1, 2 and 4 kHz), modulated in amplitude at different rate of 77, 85,93, 101 Hz for left ear and 79, 87, 95, 103 Hz for right ear, were presented binaurally by the insert phones. For each subject the response thresholds (RTHs) at 0.5, 1, 2 and 4 kHz were determined automatically and compared with the corresponding behavioral thresholds (BTHs).Results ①In the normal-hearing adults, RTHs were on average between 7~19 dB above the BTHs.②2-way repeated measures ANOVA (ear×carrier frequencies) showed significant main effect between carrier frequencies on RTH ( F =31.254; μ 3,179; P =0.000). Post Hoc analysis indicated that this effect was due to the highest threshold found at 0.5 kHz. The test showed no significant difference of threshold between left ear and right ear ( F =1.942; μ 1,179; P =0.165). ③Taking 60 dB SPL as analysis level, 2-way repeated measures ANOVA (gender×carrier frequencies) revealed significant difference of amplitude between male and female( F =16.490; μ 1,175; P =0.000); and difference of amplitude between carrier frequencies ( F =2.948; μ3, 175; P =0.034).④The average testing time was 61 minutes for male and 69 minutes for female. Independent t-test showed statistical significance within sex.⑤Two- way ANOVA (state×frequency)showed that background EEG noise were significantly higher in awake than that in sleep ( F =152.511; P =0.000). There were no appreciable significance in background noise among frequencies. Conclusion The ASSR to multiple simultaneous stimuli was proven to be a frequency specific, objective and valid technique for threshold estimation at least for normal-hearing adults. Issues concern ing clinical use were discussed.
出处 《听力学及言语疾病杂志》 CAS CSCD 2004年第6期381-384,共4页 Journal of Audiology and Speech Pathology
关键词 同时多频听觉稳态诱发反应 稳态听觉诱发电位 调幅调制声 Mltiple auditory steady state responses Steady-state evoked potential Amplitude-modulated tone
  • 相关文献

参考文献12

  • 1Lins OG, Picton TW. Auditory steady- state responses to multiple simultaneous stimuli [ J ]. Electroencephalogr Clin Neurophysiol, 1995,96: 420.
  • 2Herdman AT, Stapells DR. Thresholds determined using the monotic and dichotic multiple auditory steady - state response technique in normal - hearing subjects[J]. Scand Audiol,2001,30:41.
  • 3Picton TW, Dimitruevic A, John MS. Multiple auditory steady - state responses[J]. Ann Otol Rhino Laryngol, 2002,111: 16.
  • 4John MS, Dimtrijevic A, van Roon P, et al. Multiple auditory steady state responses to AM and FM stimuli[J]. Audiol Neurootol,2001,6:12.
  • 5Perez- Abalo MC, Savio G, Torres A,et al. Steady state responses to multiple amplitude - modulated tones: an optimaized method to test frequency - specific thresholds in hearing- impaired children and normal - hearing subjects[J]. Ear Hear, 2001,22:200.
  • 6Dimitrijevic A, John MS, Roon PV, et al. Estimating the audiogram using multiple auditory steady- state responses[J]. J Am Acad Audiol, 2002,13:205.
  • 7Picton TW, Durieus - Smith A, Champagne S, et al. Objective evaluation of aided thresholds using auditory steady - state responses [ J ]. J Am Acad Audiol, 1998,9:315.
  • 8Lins OG, Picton TW, Boucher BL, et al. Frequency - specific audiometry using steady- state responses[J]. Ear Hear, 1996; 17:81.
  • 9Rance G, Rickards F, Cohen LT, et al. The automated prediction of hearing thresholds in sleeping subjects using auditory steady - state evoked potentials[J]. Ear and hearing, 1995,16: 499.
  • 10Aoyagi M, Kiren T, Furuse H,et al. Pure- tone threshold prediction by 80 Hz amplitude modulation following response[ J]. Acta Otolaryngologica (Stockholm) , 1994(Suppl), 511:7.

二级参考文献9

  • 1[1]Beverly A,Goldstein and Craig W,Newman. Clinical masking: A decision masking process. Jack Katz. Handbook of clinical audiology[M]. Baltimore: Williams & Wilkins, 1994.109~131.
  • 2[2]Frank T,Vavrek MJ.Reference threshold levels for an ER-3A insert earphone[J]. J Am Acad Audiol,1992,3:51.
  • 3[3]Daniel A,Sklare & Larry J,Denenberg. Interaural attenuation for tubephone insert earphones[J]. Ear and Hearing, 1987,7:298.
  • 4[4]Clemis JD, Ballad WJ, Killion MC. Clinical use of an insert earphone[J].Ann Otol Rhinol Larngol,1986,95:520.
  • 5[5]Frank T, Wright DC. Attenuation provided by four different audiometric earphone systems[J].Ear Hear,1990,11:70.
  • 6[6]Blackwell KL,Oyler RF,Seyfried DN, A clinical comparison of Grason Stadler insert earphones and TDH-50P standard earphones[J]. Ear Hear, 1991,12:361.
  • 7[7]Luks SB, Borton TE, Nolen BL. Insert earphones for audiometry: application, advantages and limitations[J].Entechnology,1989,28:61.
  • 8[8]Hosford-Dunn H.Solving audiometric masking dilemmas with an insert masker[J].Arch Otolaryngol Head Neck Surg, 1986,112:92.
  • 9[9]Hall, JW, 3rd and JH Grose.The effect of conductive hearing loss on the masking-level difference: insert versus standard earphones[J].J Acoust Soc Am,1994,95:2 652.