摘要
介绍了外高桥第二发电厂2号机抗燃油系统发生的污染情况、污染原因分析,以及采取的技术措施,及时消除了污染源,使油质符合机组启动前的各项要求,同时提出了油质污染查找分析思路。
The situation and the reasons of the contamination of the fire-resistant oil system of the No.2 unit in Waigaoqiao 2nd Power Generation Co. Ltd. were introduced, as well as the technical measures adopted. The contamination source was eliminated timely and the oil quality meets the requirements of pre-starting up of the unit. The logical concept of searching for the contamination source of the fire-resistant oil was put forward.
出处
《华东电力》
北大核心
2004年第9期28-30,共3页
East China Electric Power