期刊文献+

PCS颗粒测量技术中不同粒径颗粒的相互影响 被引量:4

Mutual effects of particles with different diameters in PCS sizing technique
在线阅读 下载PDF
导出
摘要 在光子相关光谱(photoncorrelationspectroscopy,简称PCS)颗粒测量技术中,由于不同粒径颗粒的散射光强分布差异巨大,导致在多分散颗粒系中,进行颗粒粒度分布(particlesizedistribution,简称PSD)测量时,某些占有足够多数量的颗粒,由于其散射光强度相对微弱而被忽视,从而影响粒度分布的计算结果. The photon correlation spectroscopy (PCS) method is used to measure the polydisperse polystyrene particle sizes and size distribution. Because the differences in scattering light intensity for different particles are so big that the scattering light intensity for certain portion of particles is too weak to be detected when the particle size distributions (PSD) of the polydisperse particle samples are measured. Consequently, the final calculated results of the PSD can be affected by the differences in scattering light intensity.
作者 申晋 杨淑连
出处 《山东理工大学学报(自然科学版)》 CAS 2004年第4期31-34,共4页 Journal of Shandong University of Technology:Natural Science Edition
关键词 PCS颗粒测量 散射光强 粒度分布 光子相关光谱 MIE散射理论 particle sizing particle size distribution(PSD) scattering light intensity
  • 相关文献

参考文献4

  • 1Pecora R. Dynamic Light Scattering-Applications of Photon Correlation Spectroscopy [M]. New York:Plenum Press,1985.
  • 2王乃宁.颗粒粒径的光学测量技术及应用[M].北京:原子能出版社,2000..
  • 3Tkihonov A N, Arsenin V Y. Solutions of ill-posed problems[M].Washington: V. H. Winston & Sons, 1977.
  • 4Ruf H. Treatment of contributions of dust to dynamic light scattering data [J]. Langmuir, 2002, 18: 3 804-3 814.

共引文献39

同被引文献25

  • 1郭永彩,王远,高潮,邓冬梅.基于动态光散射法的亚微米级微粒粒度测量[J].重庆大学学报(自然科学版),2006,29(2):35-37. 被引量:7
  • 2喻雷寿,杨冠玲,何振江,李仪芳.用于动态光散射颗粒测量的迭代CONTIN算法[J].光电工程,2006,33(8):64-69. 被引量:25
  • 3喻雷寿,杨冠玲,何振江,李仪芳.颗粒粒径测量中约束正则CONTIN算法分析[J].激光生物学报,2007,16(1):74-78. 被引量:9
  • 4[1]Provder T.Chalenges in particle size distri-bution measurement part,present and for the 21st century[J].Progress in Organic Coalings,1997,(32):143-153.
  • 5[4]Robert.Pecora Dynamic Light Scattering.Application of Photon Correlation Spectroscopy[M].New York:Plenum press,1985:14-17.
  • 6Provder T.Chalenges in particle size distribution measurement part,present and for the 21st century[J].Progress in Organic Coalings,1997,(32):143-153.
  • 7Robert,Pecora Dynamic Light Scattering.Application of Photon Correlation Spectroscopy[J].New York:Plenum press,1985.14-17.
  • 8Otsuka K, Abe K,Sano N,et al. Two-channel self-mixing laser Doppler measurement with carrier-frequency-division multiple- xing [J]. Appl. Opt. ,2005,44 (9): 1 709-1 714.
  • 9Sudol S,Miyasaka Y,Otsuka K,et al. Quick and easy measure- ment of particle size of Brownian particles and planktons in wa- ter using a self-mixing laser[J]. Opt. Express. ,2006,14(3) 1 044-1 054.
  • 10Otsuka K,Abe K,Ko J-Y,et al. Real-time nanometer-vibration measurement with a self-mixing mierochip solid-state laser[J]. Opt. Lett.,2002,27 (15): 1 339-1 341.