摘要
介绍了以氯化钙 氨为工质对的吸附式两床循环制冷装置,并在此实验装置上进行了实验研究,得出了以氯化钙 氨为工质对的连续循环制冷系统的制冷量、性能系数COP随时间的变化关系.结果表明,此装置的制冷效果优于设计指标,设计的壳管式吸附器具有实用性.
An experimental equipment of singular cycle refrigeration system using CaCl2-NH3 as adsorption refrigeration working pair as well as the experimental study based on it are introduced.The relations between the refrigeration capacity and COP changing with testing time are investigated by experiments.The results show that the performance of the experimental equipment is better than its design indices and the shell and tube exchangers for adsorption are practicable.
出处
《上海理工大学学报》
CAS
北大核心
2004年第5期409-411,417,共4页
Journal of University of Shanghai For Science and Technology
基金
上海市重点学科建设资助项目(能源岛关键技术及基地建设)
关键词
氯化钙
氨
吸附制冷
calcium chloride
ammonia
adsorption refrigeration