摘要
分析了湛江发电厂3号发电机进相试验中失磁事故原因,探讨了发电机进相运行存在的问题,提出了发电机手动励磁调节装置及电源改进措施,对发电机进相运行安全监控进行了研究。
This paper analyzes the cause of excitationloss failure of # 3 generator during the test of leading phase operation in Zhanjiang Power plant, approaches the problems existing in the leading phase operation, puts forward the manual excitation regulation device of generator and power source improvement measures, and studies the safety monitoring of leading phase operation of generator.
出处
《电力设备》
2004年第7期46-48,共3页
Electrical Equipment
关键词
发电机
励磁系统
失磁
安全控制
generator
excitation system
excitation-loss