摘要 为保证制冷系统高效运行,风冷冰箱需要定期进行除霜。除霜过程包括对蒸发器加热、除霜、处理化霜水等主要步骤,在这个过程中,加热元件产生的热量融化霜层,但同时也带来箱内温度波动和能耗增加等副作用。本文针对化霜加热过程进行分析,探讨更高效的加热控制方法。 To ensure refrigeration system run efficiently,the refrigerator cooled by forced air circulation need defrosting on a regular basis.The defrosting process should include several main steps such as heating the evaporator,melting the frost and disposal the defrosted water.In this process,the heater not only prevent the permanent formation of frost,but also bring some side effects such as temperature fluctuations in the compartment and increase of energy consumption.This paper is dedicated to analyze the process of defrosting to explore more efficient method for controlling the heater.
出处 《电器》 2013年第S1期142-147,共6页 China Appliance
关键词 化霜加热管 控制程序 对流换热 Defrost heater Control procedures Thermal convection
  • 相关文献

同被引文献33

  • 1宋新洲,范志军.利用冷藏室循环热进行化霜预处理的蒸发器化霜系统的试验研究[J].制冷技术,2012,32(1):15-18. 被引量:5
  • 2李成武,钟金华,陈星.无霜冰箱化霜可靠性设计[J].电器,2012(S1):142-147. 被引量:3
  • 3李永,朱日昭.间冷式冰箱热气流除霜的试验[J].家用电器科技,1993(6):12-13. 被引量:3
  • 4张文慧,龚毅.冷冻冷藏陈列柜蒸发器结霜研究及融霜技术现状[J].制冷,2006,25(3):23-27. 被引量:8
  • 5HUANGJ M, HSIEHWC, KEXJ, etal. The effects of frost thickness on the heat transfer of finned tube heat exchanger subject to the combined influence of fan types [J]. Applied Thermal Engineering, 2008, 28(7) : 728-737.
  • 6AYNUR T N, INAN C, KARATAS H, et al. Real time upright freezer evaporator performance under frosted conditions [C]//9th International Refrigeration and Air Conditioning Conference at Purdue. West La- fayette, USA: IRACC, 2002.. 675-681.
  • 7OZKAN D B, OZIL E, |NAN C. Experimental inves- tigation of the defrosting process on domestic refriger- ator finned tube evaporators [J]. Heat Transfer Engi- neering, 2012, 33(6): 548-557.
  • 8MELO C, KNABBEN F T, PEREIRA P V. An ex- perimental study on defrost heaters applied to frost- free household refrigerators [J-/. Applied Thermal En- gineering, 2013, 51(1): 239-245.
  • 9BANSAL P, FOTHERGILL D, FERNANDES R. Thermal analysis of the defrost cycle in a domestic freezer [J]. International Journal of Refrigeration, 2010, 33(3): 589-599.
  • 10KNABBEN F T, HERMES C J L, MELO C. In-situ study of frosting and defrosting processes in tube-fin evaporators of household refrigerating appliances [J]. International Journal of Refrigeration, 2011, 34 (8) : 2031-2041.

引证文献5

二级引证文献17

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部