期刊文献+

Investigations by electrochemical quartz crystal impedance system-electrodeposition of silver and polyaniline

Investigations by electrochemical quartz crystal impedance system-electrodeposition of silver and polyaniline
全文增补中
导出
摘要 An electrochemical quartz crystal impedance system (EQCIS) which allows rapid and simultaneous measurements of admittance spectra of piezoelectric quartz crystal resonance during electrochemical processes was developed by combining an HP 4395A Network/Spectrum/Impedance analyzer with an EG & G M283 potentiostat. Non-linear least square regression analyses of simultaneously acquired conductance and susceptance data were discussed in detail, giving that Rm, Cs, 1/Cm (or Lm) and of as estimation parameters is the best choice among various fitting routines. Equivalent electrical circuit parameters of quartz crystal resonance during electrodeposition of silver and polyaniline and electrochemical processes of the deposits were obtained and discussed according to changes in electrode mass, electrode surface roughness and film conductivity etc. The significant changes of motional resistance Rm and static capacitance C, observed in the silver case was believed to result mainly from changes in electrode surface roughness and the linear relationship between them was well explained by the following equation, Cs = Cq+ Ce = εqAq/ hq + εek2Rm/[he(ωρLηL]1/2. An electrochemical quartz crystal impedance system (EQCIS) which allows rapid and simultaneous measurements of admittance spectra of piezoelectric quartz crystal resonance during electrochemical processes was developed by combining an HP 4395A Network/Spectrum/Impedance analyzer with an EG & G M283 potentiostat. Non-linear least square regression analyses of simultaneously acquired conductance and susceptance data were discussed in detail, giving that Rm, Cs, 1/Cm (or Lm) and of as estimation parameters is the best choice among various fitting routines. Equivalent electrical circuit parameters of quartz crystal resonance during electrodeposition of silver and polyaniline and electrochemical processes of the deposits were obtained and discussed according to changes in electrode mass, electrode surface roughness and film conductivity etc. The significant changes of motional resistance Rm and static capacitance C, observed in the silver case was believed to result mainly from changes in electrode surface roughness and the linear relationship between them was well explained by the following equation, Cs = Cq+ Ce = εqAq/ hq + εek2Rm/[he(ωρLηL]1/2.
出处 《Chinese Journal of Chemistry》 SCIE CAS CSCD 1999年第5期491-501,426,共11页 中国化学(英文版)
基金 National Natural Science Foundation of China (No. 29875006) Educational 'Committee Foundation of China (No. Liu [1997]436) Science and Technology Foundation of Hunan Province for Youth.
关键词 In situ quartz crystal impedance measurement ELECTROCHEMISTRY SILVER POLYANILINE In situ quartz crystal impedance measurement electrochemistry silver polyaniline
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部