摘要   介绍了颗粒计数仪在水厂的使用效果,并论述采用该计数仪对于控制水质安全和优化工艺过程的必要性,对水厂 的工艺过程改进有一定的参考价值,特别是对水质的优化监测,降低饮用水中致病原虫的风险将起非常重要的怍用。 In this paper, the necessity and the performance of appling particle counter in the field of water quality control and optimization of water treatment processes were illustrated,it s useful in improve ment of water treatment processes,especially in optimization of water quality monitoring and plays an im portant role in decreasing the risk of disease from pathogenic protozoa.
出处 《净水技术》 CAS 2004年第3期32-34,37,共4页 Water Purification Technology
关键词 北京第九水厂 水处理 颗粒计数仪 沉淀 过滤 水质监测 饮用水 particle counter sedimentation filtration risk of disease from pathogenic protozoa.
  • 相关文献

参考文献8

  • 1Guidance manual for Compliance with the Filtration and Disinfection Requirements for Public Water Systems Using surface Water Sources, USA EPA, 1991 Edition
  • 2Microbial and Disinfection Byproduct Rules Simultaneous Compliance Guidance Manual, USA EPA, Water Division, 1999
  • 3National Primary Drinking Water; Filter Backwash Recycling Rule; Final Rule, USA EPA, Federal Register. Vol. 66, No. 111,Friday ,June 8,2001, Rules and Regulations
  • 4E.E. Hargesheimer et al,Tracking filter performance with particle counting, AWWA, Vol. 90, Issue 12
  • 5Erika E. Hargesheimer, et al, Fundamentals of Drinking Water Particle Counting, September 2000
  • 6Monitoring Drinking Water Supplies for Protozoan Pathogens,Joanne O Toole and Christine Kaucner, 61st Annual Water Industry Engineers and Operators'Conference, Civic Centre- Shepparton,2 and 3 September, 1998
  • 7Nancy E. McTigue(Editor), National Assessment of Particle Removal by Filtration,October 1998
  • 8Zaid K. Chowdhury (Editor), Particle Count Method Development for Concentration Standards and Sample Stabilization, November 1999

同被引文献159

引证文献18

二级引证文献75

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部