以沙坪排涝站的布置方案优选为例,结合站址地形地质、泵房结构形式、施工等因素,引用模糊分析理论与层次分析法相结合的综合评判模型,将定性与定量分析有机结合,优选出最佳方案。实践证明,该法克服了主观因素干扰,提高了方案优选的效率和质量。
Taking optimization of layout scheme of Shaping drainage station for example, combined with the topographic and geological site factors, structural form, construction of pumping station, an comprehensive evaluation model is proposed based on fuzzy analysis theory and hierarchy analysis process. The resu lts indicate that since this method combines the quantitative and qualitative analysis naturally without being interfere d by any subjective factors, it will greatly enhance the result optimality in terms of the efficiency and quality.