期刊文献+

Rapid detection of coliforms in drinking water of Arak city using multiplex PCR method in comparison with the standard method of culture(Most probably Number) 被引量:1

Rapid detection of coliforms in drinking water of Arak city using multiplex PCR method in comparison with the standard method of culture(Most probably Number)
暂未订购
导出
摘要 Objective:To analyse molecular detection of coliforms and shorten the time of PCR.Methods:Rapid detection of coliforms by amplification of lacZ and uidA genes in a multiplex PCR reaction was designed and performed in comparison with most probably number(MPN)method for 16 artificial and 101 field samples.The molecular method was also conducted on isolated coliforms from positive MPN samples;standard sample for verification of microbial method certificated reference material;isolated strains from certificated reference material and standard bacteria.The PCR and electrophoresis parameters were changed for reducing the operation time.Results:Results of PCR for lacZ and uidA genes were similar in all of standard,operational and artificial samples and showed the 876 bp and 147 bp bands of lacZ and uidA genes by multiplex PCR.PCR results were confirmed by MPN culture method by sensitivity 86%(95%CI:0.71-0.93).Also the total execution time,with a successful change of factors,was reduced to less than two and a half hour.Conclusions:Multiplex PCR method with shortened operation time was used for the simultaneous detection of total coliforms and Escherichia coli in distribution system of Arak city.It's recommended to be used at least as an initial screening test,and then the positive samples could be randomly tested by MPN. Objective:To analyse molecular detection of coliforms and shorten the time of PCR.Methods:Rapid detection of coliforms by amplification of lacZ and uidA genes in a multiplex PCR reaction was designed and performed in comparison with most probably number(MPN)method for 16 artificial and 101 field samples.The molecular method was also conducted on isolated coliforms from positive MPN samples;standard sample for verification of microbial method certificated reference material;isolated strains from certificated reference material and standard bacteria.The PCR and electrophoresis parameters were changed for reducing the operation time.Results:Results of PCR for lacZ and uidA genes were similar in all of standard,operational and artificial samples and showed the 876 bp and 147 bp bands of lacZ and uidA genes by multiplex PCR.PCR results were confirmed by MPN culture method by sensitivity 86%(95%CI:0.71-0.93).Also the total execution time,with a successful change of factors,was reduced to less than two and a half hour.Conclusions:Multiplex PCR method with shortened operation time was used for the simultaneous detection of total coliforms and Escherichia coli in distribution system of Arak city.It’s recommended to be used at least as an initial screening test,and then the positive samples could be randomly tested by MPN.
出处 《Asian Pacific Journal of Tropical Biomedicine》 SCIE CAS 2014年第5期404-409,共6页 亚太热带生物医学杂志(英文版)
基金 Supported by the Ministry of Power of I.R.Iran(Grant No.201)
关键词 Water COLIFORMS PCR Rapid detection Water Coliforms PCR Rapid detection
  • 相关文献

同被引文献3

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部