介绍Winkler弹性地基模型在某全埋式污水处理厂底板结构设计的应用实例,探讨基床系数在工程应用中的取值和计算等问题,为其他工程设计提供参考。
In this paper,the method of Winkler elastic foundation is used in the base slap design of a whole-buried underground sewage treatment plant.The calculation and other issues of the subgrade reaction coefficient is discussed,which results can provide a reference for other engineering design.
出处
《广东土木与建筑》
2011年第3期11-13,共3页
Guangdong Architecture Civil Engineering
关键词
全埋式污水处理厂
基床系数
弹性地基
whole-buried underground sewage treatment plant
subgrade reaction coefficient