This work aims the deterministic dynamic analysis,in the time and frequency domain,of a reinforced concrete floor supported by a pre-cast pile foundation system,when subjected to the excitation produced by a large com...This work aims the deterministic dynamic analysis,in the time and frequency domain,of a reinforced concrete floor supported by a pre-cast pile foundation system,when subjected to the excitation produced by a large compressor installed in an industry for the production of air gases.The concrete slab presents a dimension of 12 m×15 m,required to support a compressor-motor assembly weighting 1,900 kN and positioned at a height of 4m of the investigated concrete floor.In this investigation,two numerical models were developed and the difference between these models is characterized by the discretization of the support points(pre-cast concrete piles).The developed numerical model adopted the usual mesh refinement techniques present in finite element method simulations implemented in the CSi SAP2000 V.17.2.0 software.Based on the developed analysis methodology,the dynamic structural response of the foundation system is evaluated in terms of natural frequencies,vibration modes,displacements,velocities,and accelerations.The maximum values of the dynamic response of the system are compared with the limit values recommended by standards and project recommendations,aiming a careful evaluation,regarding the performance of the structure in terms of excessive vibrations and the economic aspects involved in the design of the foundation system.Finally,the obtained results of the two developed numerical models are compared,as to evaluate if there are benefits in refining the support points modelling.展开更多
The competitive trends of the world market have long been forcing structural engineers to develop minimum weight and labour cost solutions. A direct consequence of this new design trend has been a considerable increas...The competitive trends of the world market have long been forcing structural engineers to develop minimum weight and labour cost solutions. A direct consequence of this new design trend has been a considerable increase in problems related to undesired floor vibrations. For this reason, structural floor systems can become vulnerable to excessive vibrations that are produced by, for example, impacts due to mechanical equipment (e.g., rotating machinery). This study investigates the dynamic behaviour of a production platform constructed of steel and located in the Santos Basin (Merluza field), Sao Paulo/SP, Brazil, when subjected to impacts produced by mechanical equipment (rotating machinery). The structural model consists of two steel decks with a total area of 1,915 m^2 (upper deck: 445 m^2, lower deck: 1,470 m^2) and supported by piles. A numerical analysis is performed to assess the dynamic impacts on the deck structure originating from the electrical generators and compressors. Based on the peak acceleration values obtained for the structure steady-state response, it is possible to evaluate the structural model performance in terms of human comfort, the maximum tolerances of the mechanical equipment and the vibration serviceability limit states of the structure.展开更多
The current steel-concrete composite floors design might be susceptible to the resonance phenomenon, causing undesirable vibrations in the frequency range that is the most noticeable to humans, i.e., 4 Hz to 8 Hz. Thi...The current steel-concrete composite floors design might be susceptible to the resonance phenomenon, causing undesirable vibrations in the frequency range that is the most noticeable to humans, i.e., 4 Hz to 8 Hz. This way, the main objective of this work is to investigate the dynamic structural behaviour of a steel-concrete composite multi-storey building when subjected to human rhythmic activities (aerobics). The studied structural model represents a typical interior floor bay of a commercial building used for gym and is composed by three floor levels spanning 20 m by 20 m, with a total area of 3×400 m2. An extensive parametric study was developed aiming to obtain the peak accelerations, RMS (root mean square) accelerations and VDV (vibration dose value) values, based on two different mathematical formulations. The human comfort of the building was analysed and the vibration transmissibility related to the steel columns was verified. Based on the found results, the investigated structural model presented high vibration levels that compromise the human comfort.展开更多
Structural problems associated with excessive vibration of building floor systems when subjected to human rhythmic activities have been frequent.In this context,this research work aims to develop an analysis methodolo...Structural problems associated with excessive vibration of building floor systems when subjected to human rhythmic activities have been frequent.In this context,this research work aims to develop an analysis methodology to evaluate the human comfort and assess the fatigue performance of steel-concrete composite floors when subjected to human rhythmic activities(aerobics).The investigated structural model corresponds to a steel-concrete floor with dimensions of 10 m×10 m and a total area of 100 m^(2).The numerical model developed for the dynamic analysis of the floor adopted the usual mesh refinement techniques present in finite element method(FEM)simulations implemented in the ANSYS program.The investigated floor dynamic response was calculated through the consideration of people practicing rhythmic activities on the structure,in order to verify the occurrence of excessive vibration and to assess the human comfort.The fatigue assessment is based on a linear cumulative damage rule through the use of the Rainflow-counting algorithm and S-N curves from traditional design codes.The results indicated that,in several analysed situations,the investigated floor presents excessive vibration and user’s discomfort.On the other hand,the structure service life values were higher than those proposed by the design codes,ensuring that the members,connections and joints will not fail by fatigue cracking.展开更多
Floors subjected to mechanical equipment loads frequently present problems associated with excessive vibration which can cause human discomfort or even reduce the structure service life.In this context,this work aims ...Floors subjected to mechanical equipment loads frequently present problems associated with excessive vibration which can cause human discomfort or even reduce the structure service life.In this context,this work aims to develop an analysis methodology in order to assess the fatigue performance of steel-concrete composite floors,when subjected to vibrations induced by mechanical equipment.The studied structural model corresponds to a steel-concrete composite floor spanning 10 m by 10 m,with a total area of 100 m^(2).The numerical model developed for the dynamic analysis adopted the usual mesh refinement techniques present in finite element method(FEM)simulations implemented in the ANSYS program.The investigated floor dynamic response was calculated through the consideration of the dynamic loadings imposed by the mechanical equipment,simulated based on the use of harmonic forces applied on the concrete slabs.Furthermore,the dynamic structural response was performed considering several scenarios for the positioning of the equipment,in order to verify the occurrence of excessive vibration.The fatigue assessment is based on a linear cumulative damage rule through the use of the Rainflow-counting algorithm and S-N curves from traditional design codes.The results of this investigation indicated that the equipment position affects directly the floor dynamic structural response and also significantly influences the structure service life.展开更多
文摘This work aims the deterministic dynamic analysis,in the time and frequency domain,of a reinforced concrete floor supported by a pre-cast pile foundation system,when subjected to the excitation produced by a large compressor installed in an industry for the production of air gases.The concrete slab presents a dimension of 12 m×15 m,required to support a compressor-motor assembly weighting 1,900 kN and positioned at a height of 4m of the investigated concrete floor.In this investigation,two numerical models were developed and the difference between these models is characterized by the discretization of the support points(pre-cast concrete piles).The developed numerical model adopted the usual mesh refinement techniques present in finite element method simulations implemented in the CSi SAP2000 V.17.2.0 software.Based on the developed analysis methodology,the dynamic structural response of the foundation system is evaluated in terms of natural frequencies,vibration modes,displacements,velocities,and accelerations.The maximum values of the dynamic response of the system are compared with the limit values recommended by standards and project recommendations,aiming a careful evaluation,regarding the performance of the structure in terms of excessive vibrations and the economic aspects involved in the design of the foundation system.Finally,the obtained results of the two developed numerical models are compared,as to evaluate if there are benefits in refining the support points modelling.
基金Acknowledgments The authors gratefully acknowledge the support for this work provided by the Brazilian Science Foundations: CAPES, CNPq and FAPERJ.
文摘The competitive trends of the world market have long been forcing structural engineers to develop minimum weight and labour cost solutions. A direct consequence of this new design trend has been a considerable increase in problems related to undesired floor vibrations. For this reason, structural floor systems can become vulnerable to excessive vibrations that are produced by, for example, impacts due to mechanical equipment (e.g., rotating machinery). This study investigates the dynamic behaviour of a production platform constructed of steel and located in the Santos Basin (Merluza field), Sao Paulo/SP, Brazil, when subjected to impacts produced by mechanical equipment (rotating machinery). The structural model consists of two steel decks with a total area of 1,915 m^2 (upper deck: 445 m^2, lower deck: 1,470 m^2) and supported by piles. A numerical analysis is performed to assess the dynamic impacts on the deck structure originating from the electrical generators and compressors. Based on the peak acceleration values obtained for the structure steady-state response, it is possible to evaluate the structural model performance in terms of human comfort, the maximum tolerances of the mechanical equipment and the vibration serviceability limit states of the structure.
文摘The current steel-concrete composite floors design might be susceptible to the resonance phenomenon, causing undesirable vibrations in the frequency range that is the most noticeable to humans, i.e., 4 Hz to 8 Hz. This way, the main objective of this work is to investigate the dynamic structural behaviour of a steel-concrete composite multi-storey building when subjected to human rhythmic activities (aerobics). The studied structural model represents a typical interior floor bay of a commercial building used for gym and is composed by three floor levels spanning 20 m by 20 m, with a total area of 3×400 m2. An extensive parametric study was developed aiming to obtain the peak accelerations, RMS (root mean square) accelerations and VDV (vibration dose value) values, based on two different mathematical formulations. The human comfort of the building was analysed and the vibration transmissibility related to the steel columns was verified. Based on the found results, the investigated structural model presented high vibration levels that compromise the human comfort.
基金the support for this work provided by the Brazilian Science Foundations:CAPES,CNPq and FAPERJ.
文摘Structural problems associated with excessive vibration of building floor systems when subjected to human rhythmic activities have been frequent.In this context,this research work aims to develop an analysis methodology to evaluate the human comfort and assess the fatigue performance of steel-concrete composite floors when subjected to human rhythmic activities(aerobics).The investigated structural model corresponds to a steel-concrete floor with dimensions of 10 m×10 m and a total area of 100 m^(2).The numerical model developed for the dynamic analysis of the floor adopted the usual mesh refinement techniques present in finite element method(FEM)simulations implemented in the ANSYS program.The investigated floor dynamic response was calculated through the consideration of people practicing rhythmic activities on the structure,in order to verify the occurrence of excessive vibration and to assess the human comfort.The fatigue assessment is based on a linear cumulative damage rule through the use of the Rainflow-counting algorithm and S-N curves from traditional design codes.The results indicated that,in several analysed situations,the investigated floor presents excessive vibration and user’s discomfort.On the other hand,the structure service life values were higher than those proposed by the design codes,ensuring that the members,connections and joints will not fail by fatigue cracking.
基金the support for this work provided by the Brazilian Science Foundations:CAPES,CNPq and FAPERJ.
文摘Floors subjected to mechanical equipment loads frequently present problems associated with excessive vibration which can cause human discomfort or even reduce the structure service life.In this context,this work aims to develop an analysis methodology in order to assess the fatigue performance of steel-concrete composite floors,when subjected to vibrations induced by mechanical equipment.The studied structural model corresponds to a steel-concrete composite floor spanning 10 m by 10 m,with a total area of 100 m^(2).The numerical model developed for the dynamic analysis adopted the usual mesh refinement techniques present in finite element method(FEM)simulations implemented in the ANSYS program.The investigated floor dynamic response was calculated through the consideration of the dynamic loadings imposed by the mechanical equipment,simulated based on the use of harmonic forces applied on the concrete slabs.Furthermore,the dynamic structural response was performed considering several scenarios for the positioning of the equipment,in order to verify the occurrence of excessive vibration.The fatigue assessment is based on a linear cumulative damage rule through the use of the Rainflow-counting algorithm and S-N curves from traditional design codes.The results of this investigation indicated that the equipment position affects directly the floor dynamic structural response and also significantly influences the structure service life.