This paper analyzes the effects of the voltage across insulator of 69 kV and 24 kV lines installed on the same pole. The case studies illustrated the lightning strike to direct top pole and mid span of ground wire usi...This paper analyzes the effects of the voltage across insulator of 69 kV and 24 kV lines installed on the same pole. The case studies illustrated the lightning strike to direct top pole and mid span of ground wire using the ATP-EMTP (Alternative Transient Program-Electromagnetic Transient Program). The results found that when lightning strike the voltage across the 69 kV line insulator at mid span is 1.55 times and 1.34 times higher than at top pole when the front time is 0.25/100μs and 10/350 μs, respectively. When lightning strike the voltage across the 24 kV line at mid span is 1.04 times and 0.64 times higher than at top pole when the front time is 0.25/100μs and 10/350μs, respectively. So the effect of lightning strike is more severe at mid span than at the direct top pole, especially for the 69 kV insulator.展开更多
This paper deals with the operation and performance of VSC (voltage source converter) based HVDC (high voltage direct current) interconnecting two extremely weak AC networks, the experience of Caprivilink project....This paper deals with the operation and performance of VSC (voltage source converter) based HVDC (high voltage direct current) interconnecting two extremely weak AC networks, the experience of Caprivilink project. It is shown in the paper that the HVDC converter automatically provides the supreme voltage and frequency stabilizing function when a critical situation is detected, no matter the disturbances appeared in sending end or receiving end AC networks. This supreme voltage and frequency stabilizing function makes it possible to avoid the blackout even if all the generators are tripped under an extra-ordinary worst contingency. By plots of recorded transients, the paper will show how the eventual blackouts are avoided.展开更多
文摘This paper analyzes the effects of the voltage across insulator of 69 kV and 24 kV lines installed on the same pole. The case studies illustrated the lightning strike to direct top pole and mid span of ground wire using the ATP-EMTP (Alternative Transient Program-Electromagnetic Transient Program). The results found that when lightning strike the voltage across the 69 kV line insulator at mid span is 1.55 times and 1.34 times higher than at top pole when the front time is 0.25/100μs and 10/350 μs, respectively. When lightning strike the voltage across the 24 kV line at mid span is 1.04 times and 0.64 times higher than at top pole when the front time is 0.25/100μs and 10/350μs, respectively. So the effect of lightning strike is more severe at mid span than at the direct top pole, especially for the 69 kV insulator.
文摘This paper deals with the operation and performance of VSC (voltage source converter) based HVDC (high voltage direct current) interconnecting two extremely weak AC networks, the experience of Caprivilink project. It is shown in the paper that the HVDC converter automatically provides the supreme voltage and frequency stabilizing function when a critical situation is detected, no matter the disturbances appeared in sending end or receiving end AC networks. This supreme voltage and frequency stabilizing function makes it possible to avoid the blackout even if all the generators are tripped under an extra-ordinary worst contingency. By plots of recorded transients, the paper will show how the eventual blackouts are avoided.