期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
Reactive oxygen species, nitric oxide and plant cell death associated with caspase-like protease activity during somatic embryogenesis in Fraxinus mandshurica 被引量:1
1
作者 Hao Wang Dongyan Zhang +2 位作者 Juan Luis Fernández-Lorenzo Hailong Shen Ling Yang 《Journal of Forestry Research》 SCIE CAS CSCD 2022年第3期1005-1017,共13页
Programmed cell death occurs in browning explants of Fraxinus mandshurica during somatic embryogenesis, but the underlying mechanism is unclear. In this study, single cotyledons of zygotic embryos of F. mandshurica we... Programmed cell death occurs in browning explants of Fraxinus mandshurica during somatic embryogenesis, but the underlying mechanism is unclear. In this study, single cotyledons of zygotic embryos of F. mandshurica were used as explants. Mitochondrial structure and function, caspase-3-like protease activity, hydrogen peroxide metabolism, and nitric oxide accumulation induced by high concentrations of sucrose and plant growth regulators were studied. The results show that plant growth regulators induced somatic embryogenesis and also promoted explant browning. High sucrose concentrations had similar effects. High concentrations of sucrose and plant growth regulators led to the accumulation of hydrogen peroxide and nitric oxide which induced changes in mitochondrial structure and function such as modifications in mitochondrial morphology, increased membrane permeability, decreased membrane potential, and the release of cytochrome c into the cytoplasm. An increase in caspase-3-like protease activity triggered programmed cell death in some browning explant cells. During somatic embryogenesis there were increased activities of superoxide dismutase, peroxidase, and catalase, which are associated with hydrogen peroxide metabolism and jointly maintain reactive oxygen species levels. Intracellular nitric oxide synthase and nitrate reductase activities were not significantly correlated with nitric oxide content. Instead, intracellular nitric oxide may be derived from non-enzymatic reactions. Our results indicate that hydrogen peroxide and nitric oxide may function as signals, playing key roles in somatic embryogenesis and programmed cell death of explant cells of F. mandshurica. The interaction between nitric oxide and reactive oxygen species determines the occurrence of programmed cell death in explant cells;somatic embryogenesis and programmed cell death are positively regulated by hydrogen peroxide. However, the regulation of nitric oxide is complex. 展开更多
关键词 Manchurian ash Somatic embryogenesis Programmed cell death MITOCHONDRIA Reactive oxide species Nitric oxide
在线阅读 下载PDF
Orogenesis: Cause of Sedimentary Formations
2
作者 Guy Guy Berthault 《Open Journal of Geology》 2013年第2期22-24,共3页
Experiments on stratification discussed here have revealed the mechanical nature of lamination as well as the role of turbulent current as agent of stratification. They challenge Steno’s principle that superposed str... Experiments on stratification discussed here have revealed the mechanical nature of lamination as well as the role of turbulent current as agent of stratification. They challenge Steno’s principle that superposed strata are successive sedimentary layers. They show that relative chronology should not be referred to as “stages” but as “sequences” of series. The rock formation studied by Lalomov shows that the duration of sedimentation could be considerably shorter than indicated by the Geological Time Scale. The latter scale corresponds to large marine transgressions and regressions that can result from the shift of polar axis following such major orogeneses as the Caledonian, Hercynian and Alpine. 展开更多
关键词 STRATIFICATION LAMINATION TURBULENT Flow Time of SEDIMENTATION OROGENESIS
暂未订购
Correction to:Reactive oxygen species,nitric oxide and plant cell death associated with caspase-like protease activity during somatic embryogenesis in Fraxinus mandshurica
3
作者 Hao Wang Dongyan Zhang +2 位作者 Juan Luis Fernández-Lorenzo Hailong Shen Ling Yang 《Journal of Forestry Research》 SCIE CAS CSCD 2022年第6期1959-1959,共1页
Correction to:J.For.Res.https://doi.org/10.1007/s11676-021-01392-y In this article Ling Yang should have been denoted as a corresponding author.The original article has been corrected.Publisher’s Note Springer Nature... Correction to:J.For.Res.https://doi.org/10.1007/s11676-021-01392-y In this article Ling Yang should have been denoted as a corresponding author.The original article has been corrected.Publisher’s Note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affi liations. 展开更多
关键词 NEUTRAL corrected MAPS
在线阅读 下载PDF
Effect of 3D anchorage attachment on the alleviating tipping/extrusion of premolars for en-mass distalization of maxillary molars with clear aligners:A finite element study
4
作者 Lurong Jia Chunjuan Wang +4 位作者 Yao He Chao Wang Antonio Apicella Jinlin Song Yubo Fan 《Medicine in Novel Technology and Devices》 2023年第2期272-280,共9页
This study aimed to explore the optimal invisible orthodontic force system during the en-mass distalization of two maxillary molars to minimize the side effect of anchorage loss by changing the direction of the applic... This study aimed to explore the optimal invisible orthodontic force system during the en-mass distalization of two maxillary molars to minimize the side effect of anchorage loss by changing the direction of the application of the orthodontic force system.A high bio-fidelity 3D finite element model including maxilla,periodontal ligament,dentition,clear aligner,3D anchorage attachment and mini-implant was established.Different lengths of lateral hooks of 3D-printed anchorage attachments and mini-implant positions into the palatal alveolus were considered.A 200 g distal force was applied to the lateral hooks of different horizontal lengths(3.26 mm,6.52 mm and 9.78 mm)with the mini-implant as the application point.Using ABAQUS software,orthodontic tooth movements under 12 different clinical treatment designs were analyzed and calculated.The 3D anchorage attachment enhanced the anchorage of anterior teeth and alleviated the tipping/extrusion of premolars.In contrast to without clear aligners,length of the lateral hook had a negligible effect on both mesial tipping and buccal tipping with clear aligners,which could then be ignored.The change in mesial tipping was less and nearly remained constant despite of the different heights of the mini-implant.The 3D anchorage attachment assisted clear aligner can avoid the side effects of anterior tooth proclination caused by insufficient anchorage.The length of the lateral hook,and height of the mini-implant in this invisible orthodontic force system hardly affects the tooth movement of anchorage units.Clear aligners can effectively control the rotation and tipping of anchorage units caused by 3D anchorage attachment. 展开更多
关键词 Clear aligner ORTHODONTICS 3D printing Three-dimensional finite element ATTACHMENTS Reinforced anchorage
暂未订购
上一页 1 下一页 到第
使用帮助 返回顶部