A slit die apparatus is used to measure hole pressures for two polymer melts.Hole pressures up to 110kPa are determined and shear rates reach 200 s<sup>-1</sup>.Viscosity data obtained from the same appara...A slit die apparatus is used to measure hole pressures for two polymer melts.Hole pressures up to 110kPa are determined and shear rates reach 200 s<sup>-1</sup>.Viscosity data obtained from the same apparatus agreewell with the values obtained from a cone-and-plate rheometer or a capillary rheometer.The hole pressuresobtained by direct measurements are all positive and increase with increasing shear stress.The values of the firstnormal stress difference obtained from hole pressures according to the Higashitani-Pritchard(HP)theory are ofthe right order of magnitude,but appear to be on the low side when compared with values obtained from a cone-and-plate rheometer or with values obtained via exit pressures.It is believed that the hole pressure is a measureof fluid elasticity,but cannot yield accurate values of the first normal stress difference according to the HP theory.展开更多
Two kinds of polypeptides were tethered onto the surface of polypropylene microporous membrane (PPMM) through a ring opening polymerization of L-glutamate N-carboxyanhydride initiated by amino groups which were intr...Two kinds of polypeptides were tethered onto the surface of polypropylene microporous membrane (PPMM) through a ring opening polymerization of L-glutamate N-carboxyanhydride initiated by amino groups which were introduced by ammonia plasma and y-aminopropyl triethanoxysilane treatments. X-ray photoelectron spectroscopy (XPS), attenuated total reflectance Fourier transform infrared spectroscopy (FT-IR/ATR), scanning electron microscopy (SEM), together with water contact angle measurements were used to characterize the modified membranes. XPS analyses and FT-IR/ATR spectra demonstrated that polypeptides are actually grafted onto the membrane surface. The wettability of the membrane surface increases at first and then decreases with the increase in grafting degrees of polypeptide. Platelet adhesion and murine macrophage attachment experiments reveal an enhanced hemocompatibility for the polypeptide modified PPMMs. All these results give evidence that polypeptide grafting can simultaneously improve the hemocompatibility as well as reserve the hydrophobicity for the membrane, which will provide a potential approach to improve the performance of polypropylene hollow fiber microporous membrane used in artificial oxygenator.展开更多
A simple, rapid, and reproducible method is described employing solid phase extraction(SPE) using dichloromethane followed by gas chromatography(GC) with flame ionization detection(FID) for determination of volatile ...A simple, rapid, and reproducible method is described employing solid phase extraction(SPE) using dichloromethane followed by gas chromatography(GC) with flame ionization detection(FID) for determination of volatile organic compound(VOC) from the Buriganga River water of Bangladesh. The method was applied to detect the benzene, toluene, ethylbenzene, xylene and cumene(BTEXC) in the sample collected from the surface or 15 cm depth of water. Two hundred ml of n hexane pretreated and filtered water samples were applied directly to a C 18 SPE column. BTEXC were extracted with dichloromethane and average concentrations were obtained as 0 104 to 0 372 μg/ml. The highest concentration of benzene was found as 0 372 μg/ml with a relative standard deviation(RSD) of 6 2%, and cumene was not detected. Factors influencing SPE e.g., adsorbent types, sample load volume, eluting solvent, headspace and temperatures, were investigated. A cartridge containing a C 18 adsorbent and using dichloromethane gave better performance for extraction of BTEXC from water. Average recoveries exceeding 90% could be achieved for cumene at 4℃ with a 2 7% RSD.展开更多
Spherical polyethylene/polypropylene (PE/PP) in-reactor blend granules with various ethylene/propylene molar ratios and high porosity were synthesized using a high yield TiCVMgCl2 supported catalyst. A solution of ben...Spherical polyethylene/polypropylene (PE/PP) in-reactor blend granules with various ethylene/propylene molar ratios and high porosity were synthesized using a high yield TiCVMgCl2 supported catalyst. A solution of benzoyl peroxide (BPO)/maleic anhydride (MAH)/xylene (interfacial reagent) or BPO/MAH/St (comonomer) was absorbed onto the PE/PP in- reactor blend granules, and solid phase graft polymerization of MAH on PE/PP was conducted. The amount of grafted MAH on PE/PP was measured through chemical titration. The results showed that solid phase graft polymerization of MAH in PE/PP in-reactor blend granules produced graft copolymer with high amount of grafted MAH, and the amount of grafted MAH was raised slightly when St was introduced as comonomer. The graft in-reactor blend was fractionated into five fractions through temperature-gradient extraction fractionation (TGEF), and the fractions were analyzed by FTIR. The results revealed that MAH is mainly grafted on the PE segments, whereas MAH was predominantly grafted on the PP segments when St was present in the graft polymerization system. In addition, the final product is still in the form of regular spherical granules, which is beneficial for industrial processing.展开更多
The deficiencies of popular phthalate plasticizers(ready migration from a polymer matrix into which they have been incorporated,flammability,environmental pollution,human health risks)have stimulated efforts to develo...The deficiencies of popular phthalate plasticizers(ready migration from a polymer matrix into which they have been incorporated,flammability,environmental pollution,human health risks)have stimulated efforts to develop new effective,nonmigrating,low-cost,nontoxic replacements.In the main,these have been based on readilyavailable,nontoxic biobased precursors.Some,including those prepared from plant oils,have been generated from biomaterials themselves.However,the more numerous and generally more effective have been generated from discrete compounds produced from various biomaterials.Several structural features of effective plasticizers have been recognized.Polar functionality is required to assure compatibility with a wide range of polymeric materials,including poly(vinyl chloride)(PVC),the most heavily plasticized polymer.A branched structure greatly enhances the effectiveness of compounds used as plasticizers.An oligomeric structure may strongly limit or prevent migration from a polymer matrix.Hyperbranched oligomers of defined structure derived from the readilyavailable,inexpensive,nontoxic biomonomers,glycerol and adipic acid contain all these features and are excellent plasticizers.They contain ester functionality,are highly branched,and display a large number of end groups,all of which contribute to their effectiveness as plasticizers.展开更多
文摘A slit die apparatus is used to measure hole pressures for two polymer melts.Hole pressures up to 110kPa are determined and shear rates reach 200 s<sup>-1</sup>.Viscosity data obtained from the same apparatus agreewell with the values obtained from a cone-and-plate rheometer or a capillary rheometer.The hole pressuresobtained by direct measurements are all positive and increase with increasing shear stress.The values of the firstnormal stress difference obtained from hole pressures according to the Higashitani-Pritchard(HP)theory are ofthe right order of magnitude,but appear to be on the low side when compared with values obtained from a cone-and-plate rheometer or with values obtained via exit pressures.It is believed that the hole pressure is a measureof fluid elasticity,but cannot yield accurate values of the first normal stress difference according to the HP theory.
基金This project was supported by the National Natural Science Foundation of China (No. 20074033)the National Basic Research Program of China (No. 2003CB15705).
文摘Two kinds of polypeptides were tethered onto the surface of polypropylene microporous membrane (PPMM) through a ring opening polymerization of L-glutamate N-carboxyanhydride initiated by amino groups which were introduced by ammonia plasma and y-aminopropyl triethanoxysilane treatments. X-ray photoelectron spectroscopy (XPS), attenuated total reflectance Fourier transform infrared spectroscopy (FT-IR/ATR), scanning electron microscopy (SEM), together with water contact angle measurements were used to characterize the modified membranes. XPS analyses and FT-IR/ATR spectra demonstrated that polypeptides are actually grafted onto the membrane surface. The wettability of the membrane surface increases at first and then decreases with the increase in grafting degrees of polypeptide. Platelet adhesion and murine macrophage attachment experiments reveal an enhanced hemocompatibility for the polypeptide modified PPMMs. All these results give evidence that polypeptide grafting can simultaneously improve the hemocompatibility as well as reserve the hydrophobicity for the membrane, which will provide a potential approach to improve the performance of polypropylene hollow fiber microporous membrane used in artificial oxygenator.
文摘A simple, rapid, and reproducible method is described employing solid phase extraction(SPE) using dichloromethane followed by gas chromatography(GC) with flame ionization detection(FID) for determination of volatile organic compound(VOC) from the Buriganga River water of Bangladesh. The method was applied to detect the benzene, toluene, ethylbenzene, xylene and cumene(BTEXC) in the sample collected from the surface or 15 cm depth of water. Two hundred ml of n hexane pretreated and filtered water samples were applied directly to a C 18 SPE column. BTEXC were extracted with dichloromethane and average concentrations were obtained as 0 104 to 0 372 μg/ml. The highest concentration of benzene was found as 0 372 μg/ml with a relative standard deviation(RSD) of 6 2%, and cumene was not detected. Factors influencing SPE e.g., adsorbent types, sample load volume, eluting solvent, headspace and temperatures, were investigated. A cartridge containing a C 18 adsorbent and using dichloromethane gave better performance for extraction of BTEXC from water. Average recoveries exceeding 90% could be achieved for cumene at 4℃ with a 2 7% RSD.
基金This work was supported by the Special Fund for Major State Basic Research Projects (Grant no. G1999064803).
文摘Spherical polyethylene/polypropylene (PE/PP) in-reactor blend granules with various ethylene/propylene molar ratios and high porosity were synthesized using a high yield TiCVMgCl2 supported catalyst. A solution of benzoyl peroxide (BPO)/maleic anhydride (MAH)/xylene (interfacial reagent) or BPO/MAH/St (comonomer) was absorbed onto the PE/PP in- reactor blend granules, and solid phase graft polymerization of MAH on PE/PP was conducted. The amount of grafted MAH on PE/PP was measured through chemical titration. The results showed that solid phase graft polymerization of MAH in PE/PP in-reactor blend granules produced graft copolymer with high amount of grafted MAH, and the amount of grafted MAH was raised slightly when St was introduced as comonomer. The graft in-reactor blend was fractionated into five fractions through temperature-gradient extraction fractionation (TGEF), and the fractions were analyzed by FTIR. The results revealed that MAH is mainly grafted on the PE segments, whereas MAH was predominantly grafted on the PP segments when St was present in the graft polymerization system. In addition, the final product is still in the form of regular spherical granules, which is beneficial for industrial processing.
文摘The deficiencies of popular phthalate plasticizers(ready migration from a polymer matrix into which they have been incorporated,flammability,environmental pollution,human health risks)have stimulated efforts to develop new effective,nonmigrating,low-cost,nontoxic replacements.In the main,these have been based on readilyavailable,nontoxic biobased precursors.Some,including those prepared from plant oils,have been generated from biomaterials themselves.However,the more numerous and generally more effective have been generated from discrete compounds produced from various biomaterials.Several structural features of effective plasticizers have been recognized.Polar functionality is required to assure compatibility with a wide range of polymeric materials,including poly(vinyl chloride)(PVC),the most heavily plasticized polymer.A branched structure greatly enhances the effectiveness of compounds used as plasticizers.An oligomeric structure may strongly limit or prevent migration from a polymer matrix.Hyperbranched oligomers of defined structure derived from the readilyavailable,inexpensive,nontoxic biomonomers,glycerol and adipic acid contain all these features and are excellent plasticizers.They contain ester functionality,are highly branched,and display a large number of end groups,all of which contribute to their effectiveness as plasticizers.