Quantification by Signal to Noise Ratio of Active Infrared Thermography Data Processing Techniques 被引量:2
1
作者 R. Hidalgo-Gato J. R. Andrés +1 位作者 J. M. López-Higuera F. J. Madruga 《Optics and Photonics Journal》 2013年第4期20-26,共7页
In this paper, the use of a signal to noise ratio (SNR) is proposed for the quantification of the goodness of some selected processing techniques of thermographic images, such as differentiated absolute contrast, skew... In this paper, the use of a signal to noise ratio (SNR) is proposed for the quantification of the goodness of some selected processing techniques of thermographic images, such as differentiated absolute contrast, skewness and kurtosis based algorithms, pulsed phase transform, principal component analysis and thermographic signal reconstruction. A new hybrid technique is also applied (PhAC—Phase absolute contrast), it combines three different processing techniques: phase absolute contrast, pulsed phase thermography and thermographic signal reconstruction. The quality of the results is established on the basis of the values of the parameter SNR, assessed for the present defects in the analyzed specimen, which enabled to quantify and compare their identification and the quality of the results of the employed technique. 展开更多
关键词 IMAGE Processing INFRARED THERMOGRAPHY NONDESTRUCTIVE Testing ACTIVE THERMOGRAPHY SNR
暂未订购
REAL-TIME OPTICAL MONITORING OF CAPILLARY GRID SPATIAL PATTERN IN EPITHELIUM BY SPATIALLY RESOLVED DIFFUSE REFLECTANCE PROBE
2
作者 GUENNADI SAIKO ALEXANDRE DOUPLIK 《Journal of Innovative Optical Health Sciences》 SCIE EI CAS 2012年第2期10-18,共9页
We developed a novel method for real-time monitoring of alteration of the local epithelium vessel/capillary and blood oxygenation spatial pattern in epithelium exploiting a compact fibre sensor system based on spatial... We developed a novel method for real-time monitoring of alteration of the local epithelium vessel/capillary and blood oxygenation spatial pattern in epithelium exploiting a compact fibre sensor system based on spatially and spectrally resolved diffuse reflectance.The method is based on collection of spatially resolved diffuse reflectance Re(λ)by fiber sensors.The spatial resolution is provided as a dependence of Re(λ)on a set of distancesρbetween the source and detector(attenuation curve).It is expected that the new method can reasonably extract the minor spatial deviations of oxygenation and local blood volume fraction-parameters,directly related to the local vessel density and capillary spatial patterns in the epithelium.Light scattering in visible range is naturally taken into account in the proposed method. 展开更多
关键词 Spatially resolved diffuse reflectance fiber optics biospectroscopy DIAGNOSTICS shock cancer
原文传递
MICROENDOSCOPIC SPECTRAL IMAGING AS A TOOL FOR SMALL DUCTUAL DIAGNOSTICS:PRELIMINARY EXPERIENCE
3
作者 A.DOUPLIK W.L.LEONG +4 位作者 A.M.EASSON S.DONE B.C.WILSON A.SHAHMOON Z.ZALEVSKY 《Journal of Innovative Optical Health Sciences》 SCIE EI CAS 2012年第3期64-70,共7页
A technical feasibility of autofluorescence ductoscopy in breast milk ducts as blood vessels phantoms has been assessed as successful.Malignant tumor can be clearly identified through the milk ducts.We also present th... A technical feasibility of autofluorescence ductoscopy in breast milk ducts as blood vessels phantoms has been assessed as successful.Malignant tumor can be clearly identified through the milk ducts.We also present the operation principle as well as the preliminary experimental results of a new type of microsize multicorefiber that enables imaging through blood vessel phantoms.Imaging of a manipulated microwire through a drilled phantom is presented. 展开更多
关键词 Cancer margin delineation ENDOSCOPY MICROENDOSCOPY autofluorescence imaging surgical guidance multicorefibers
原文传递
Identification of Carbon Black in Military Textiles Using Infrared Imaging Techniques
4
作者 J. R. Andrés R. Hidalgo-Gato +1 位作者 J. M. López-Higuera F. J. Madruga 《Optics and Photonics Journal》 2013年第4期27-30,共4页
The carbon black has been used in military fabrics to comply with the color requirements and infrared radiation lessening criteria. Currently, military industries don’t distinguish between fabrics with carbon black f... The carbon black has been used in military fabrics to comply with the color requirements and infrared radiation lessening criteria. Currently, military industries don’t distinguish between fabrics with carbon black fibers or with carbon black into dyes or prints. The latter initially allows us to comply with the color specifications in the visible and infrared, but fabrics are degraded with use losing that initial capacity. The inclusion of carbon black in the fiber gets that the fabric doesn’t degrade with the wear, washed and dried, ensuring the accomplishment of the specifications all the time. The use of infrared imaging will allow us to define a method to discriminate those textiles with carbon black in their fibers from those which are dyed or printed. 展开更多
关键词 MILITARY TEXTILES FABRICS Infrared Imaging Step-Heating Carbon BLACK Thermal Response
暂未订购