期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Aristotle’s dream:Evolutionary and neural aspects of aesthetic communication in the arts
1
作者 Christa Sütterlin Xinchi Yu 《PsyCh Journal》 2021年第2期224-243,共20页
Art in general perception is something that transcends our notion of reality.In view of the earliest findings in Paleolithic sites,their abstract appearance and sometimes ceremonial context increased their status of a... Art in general perception is something that transcends our notion of reality.In view of the earliest findings in Paleolithic sites,their abstract appearance and sometimes ceremonial context increased their status of a secret language.Even the first figurative cave paintings remained in a context of an encoded semantic whole.The highly symbolic value of art seemed invulnerable.It was just the claim for“mimesis”in Greek antiquity(Plato)that urged artists to“realistically”depict what can be seen—as to stay in track of eternal messages behind.This devaluated the artistic oeuvre to a purely imitating craft and had to overcome at once several inherent obstacles.First,that reality(the phenomenal world)is in general only a pale reflection of what lays behind(Platonic ideas)and second,that the human eye,unlike the human mind,cannot penetrate to more than ephemeral impressions.Moreover,it mixed up reality with what we are able to see(i.e.visual perception),thus supposing a pinpoint representation of the world by our senses.Aristotle was the first to qualify art as picturing more than we usually are meant to see,filling the gap between the sensual and the spiritual world.Aristotelian aesthetics includes concepts of reduction and selection of composition and emotion,thus a summarized view within any performance of poetics or painting.And it took centuries to close the gap between natural and aesthetic perception or art.Life sciences in the 20th century discovered the evolutionary basis of sensory perception as being highly biased and organized,concept as emotion-driven and thus,mentally equipped as well.This sets a new approach in our understanding of perception,art,and aesthetics as an ongoing communication in process on common bases.Art may cooperate or disagree,but never can cut the nexus with its perceptual prejudices and substrate. 展开更多
关键词 art COMMUNICATION complexity reduction evolution MIMESIS REALISM template formation
在线阅读 下载PDF
Electrochemical measurement of serotonin by Au-CNT electrodes fabricated on microporous cell culture membranes 被引量:1
2
作者 Ashley A.Chapin Pradeep R.Rajasekaran +4 位作者 David N.Quan Liangbing Hu Jens Herberholz William E.Bentley Reza Ghodssi 《Microsystems & Nanoengineering》 EI CSCD 2020年第1期494-506,共13页
Gut–brain axis(GBA)communication relies on serotonin(5-HT)signaling between the gut epithelium and the peripheral nervous system,where 5-HT release patterns from the basolateral(i.e.,bottom)side of the epithelium act... Gut–brain axis(GBA)communication relies on serotonin(5-HT)signaling between the gut epithelium and the peripheral nervous system,where 5-HT release patterns from the basolateral(i.e.,bottom)side of the epithelium activate nerve afferents.There have been few quantitative studies of this gut-neuron signaling due to a lack of real-time measurement tools that can access the basolateral gut epithelium.In vitro platforms allow quantitative studies of cultured gut tissue,but they mainly employ offline and endpoint assays that cannot resolve dynamic molecular-release patterns.Here,we present the modification of a microporous cell culture membrane with carbon nanotube-coated gold(Au-CNT)electrodes capable of continuous,label-free,and direct detection of 5-HT at physiological concentrations.Electrochemical characterization of single-walled carbon nanotube(SWCNT)-coated Au electrodes shows increased electroactive surface area,5-HT specificity,sensitivity,and saturation time,which are correlated with the CNT film drop-cast volume.Two microliters of CNT films,with a 10-min saturation time,0.6μA/μM 5-HT sensitivity,and reliable detection within a linear range of 500 nM–10μM 5-HT,can be targeted for high-concentration,high-time-resolution 5-HT monitoring.CNT films(12.5μL)with a 2-h saturation time,4.5μA/μM 5-HT sensitivity,and quantitative detection in the linear range of 100 nM–1μM can target low concentrations with low time resolution.These electrodes achieved continuous detection of dynamic diffusion across the porous membrane,mimicking basolateral 5-HT release from cells,and detection of cell-released 5-HT from separately cultured RIN14B cell supernatant.Electrode-integrated cell culture systems such as this can improve in vitro molecular detection mechanisms and aid in quantitative GBA signaling studies. 展开更多
关键词 release SATURATION dynamic
原文传递
3D-Printed electrochemical sensor-integrated transwell systems
3
作者 Pradeep Ramiah Rajasekaran Ashley Augustiny Chapin +3 位作者 David N.Quan Jens Herberholz William E.Bentley Reza Ghodssi 《Microsystems & Nanoengineering》 EI CSCD 2020年第1期357-368,共12页
This work presents a 3D-printed,modular,electrochemical sensor-integrated transwell system for monitoring cellular and molecular events in situ without sample extraction or microfluidics-assisted downstream omics.Simp... This work presents a 3D-printed,modular,electrochemical sensor-integrated transwell system for monitoring cellular and molecular events in situ without sample extraction or microfluidics-assisted downstream omics.Simple additive manufacturing techniques such as 3D printing,shadow masking,and molding are used to fabricate this modular system,which is autoclavable,biocompatible,and designed to operate following standard operating protocols(SOPs)of cellular biology.Integral to the platform is a flexible porous membrane,which is used as a cell culture substrate similarly to a commercial transwell insert.Multimodal electrochemical sensors fabricated on the membrane allow direct access to cells and their products.A pair of gold electrodes on the top side of the membrane measures impedance over the course of cell attachment and growth,characterized by an exponential decrease(~160%at 10Hz)due to an increase in the double layer capacitance from secreted extracellular matrix(ECM)proteins.Cyclic voltammetry(CV)sensor electrodes,fabricated on the bottom side of the membrane,enable sensing of molecular release at the site of cell culture without the need for downstream fluidics.Real-time detection of ferrocene dimethanol injection across the membrane showed a three order-of-magnitude higher signal at the membrane than in the bulk media after reaching equilibrium.This modular sensor-integrated transwell system allows unprecedented direct,real-time,and noninvasive access to physical and biochemical information,which cannot be obtained in a conventional transwell system. 展开更多
关键词 TRANSWELL ELECTROCHEMICAL CULTURE
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部