To measure the signals with high freq u ency(>500 MHz),a sampling frequency down conversion method is introduced.This pa per analyzes the intermodulation signals and figures out the relationship betwee n the interm...To measure the signals with high freq u ency(>500 MHz),a sampling frequency down conversion method is introduced.This pa per analyzes the intermodulation signals and figures out the relationship betwee n the intermodulation signal and intermediate frequenc y signal.Based on the frequency conversion technology,an exclusion algorithm i s proposed a nd the actual implementation of the algorithm is given.The application resu lts show that the exclusion algorithm can identify the intermodulation signal exactly and eliminate the bad influence on the frequency measurement.展开更多
Modulation domain measurement can be u sed to analyze the frequency,phase,and time intervals which transiently change with time.During the implementation of modulation domain analyzer,meas urement errors can be introd...Modulation domain measurement can be u sed to analyze the frequency,phase,and time intervals which transiently change with time.During the implementation of modulation domain analyzer,meas urement errors can be introduced in multiple parts.Aiming at a typical implementation of modul ation domain analyzer,this paper analyzes the inherent error between channe l s,temperature drift error in time-to-digital converter(TDC),random err or,time-base error and their influence on the modulation domain measurement.It also gives a correction sche me and comparison of the measurement results.The frequency resolution can be im proved from 10 to 12 bit/s after correction.展开更多
Klinefelter syndrome (KS) (47, XXY) is the most abundant sex-chromosome disorder, and is a common cause of infertility and hypogonadism in men. Most men with KS go through life without knowing the diagnosis, as on...Klinefelter syndrome (KS) (47, XXY) is the most abundant sex-chromosome disorder, and is a common cause of infertility and hypogonadism in men. Most men with KS go through life without knowing the diagnosis, as only 25% are diagnosed and only a few of these before puberty. Apart from hypogonadism and azoospermia, most men with KS suffer from some degree of learning disability and may have various kinds of psychiatric problems. The effects of long-term hypogonadism may be difficult to discern from the gene dose effect of the extra X-chromosome. Whatever the cause, alterations in body composition, with more fat and less muscle mass and diminished bone mineral mass, as well as increased risk of metabolic consequences, such as type 2 diabetes and the metabolic syndrome are all common in KS. These findings should be a concern as they are not simply laboratory findings; epidemiological studies in KS populations show an increased risk of beth hospitalization and death from various diseases. Testosterone treatment should be offered to KS patients from early puberty, to secure a proper masculine development, nonetheless the evidence is weak or nonexisting, since no randomized controlled trials have ever been published. Here, we will review the current knowledge of hypogonadism in KS and the rationale for testosterone treatment and try to give our best recommendations for surveillance of this rather common, but often ignored, syndrome.展开更多
An inclusion complex between p-tert-butylcalixarene and toluene was prepared. It crystallized in the monoclinic system with space group P 2 1/ n , a =1.734 7(2) nm, b =1.903 2(2) nm, c =1.972 9(2) ...An inclusion complex between p-tert-butylcalixarene and toluene was prepared. It crystallized in the monoclinic system with space group P 2 1/ n , a =1.734 7(2) nm, b =1.903 2(2) nm, c =1.972 9(2) nm , β =94.74(1)°, V =6.491 2(14) nm 3, Z =4. The toluene molecule was included in the macrocycle cavity. The calixanene is of a pinched cone conformation.展开更多
This paper describes the detailed desi gn of data acquisition device with multi-channel and high-precision for aerosp ace.Based on detailed analysis of the advantages and disadvantages of tw o common acquisition circu...This paper describes the detailed desi gn of data acquisition device with multi-channel and high-precision for aerosp ace.Based on detailed analysis of the advantages and disadvantages of tw o common acquisition circuits,the design factors of acquisition device focus o n accuracy,sampling rate,hardware overhead and design space.The me chanical structure of the system is divided into different card layers according to different functions and the structure has the characteristics of high reliability,conveni ence to install and scalability.To ens ure reliable operation mode,the interface uses the optocoupler isolated from th e e xternal circuit.The transmission of signal is decided by the current in the cur rent loop that consists of optocouplers between acquisition device and t est bench.In multi-channel switching circuit,by establ ishing analog multiplexer model,the selection principles of circuit modes are given.展开更多
文摘To measure the signals with high freq u ency(>500 MHz),a sampling frequency down conversion method is introduced.This pa per analyzes the intermodulation signals and figures out the relationship betwee n the intermodulation signal and intermediate frequenc y signal.Based on the frequency conversion technology,an exclusion algorithm i s proposed a nd the actual implementation of the algorithm is given.The application resu lts show that the exclusion algorithm can identify the intermodulation signal exactly and eliminate the bad influence on the frequency measurement.
文摘Modulation domain measurement can be u sed to analyze the frequency,phase,and time intervals which transiently change with time.During the implementation of modulation domain analyzer,meas urement errors can be introduced in multiple parts.Aiming at a typical implementation of modul ation domain analyzer,this paper analyzes the inherent error between channe l s,temperature drift error in time-to-digital converter(TDC),random err or,time-base error and their influence on the modulation domain measurement.It also gives a correction sche me and comparison of the measurement results.The frequency resolution can be im proved from 10 to 12 bit/s after correction.
文摘Klinefelter syndrome (KS) (47, XXY) is the most abundant sex-chromosome disorder, and is a common cause of infertility and hypogonadism in men. Most men with KS go through life without knowing the diagnosis, as only 25% are diagnosed and only a few of these before puberty. Apart from hypogonadism and azoospermia, most men with KS suffer from some degree of learning disability and may have various kinds of psychiatric problems. The effects of long-term hypogonadism may be difficult to discern from the gene dose effect of the extra X-chromosome. Whatever the cause, alterations in body composition, with more fat and less muscle mass and diminished bone mineral mass, as well as increased risk of metabolic consequences, such as type 2 diabetes and the metabolic syndrome are all common in KS. These findings should be a concern as they are not simply laboratory findings; epidemiological studies in KS populations show an increased risk of beth hospitalization and death from various diseases. Testosterone treatment should be offered to KS patients from early puberty, to secure a proper masculine development, nonetheless the evidence is weak or nonexisting, since no randomized controlled trials have ever been published. Here, we will review the current knowledge of hypogonadism in KS and the rationale for testosterone treatment and try to give our best recommendations for surveillance of this rather common, but often ignored, syndrome.
文摘An inclusion complex between p-tert-butylcalixarene and toluene was prepared. It crystallized in the monoclinic system with space group P 2 1/ n , a =1.734 7(2) nm, b =1.903 2(2) nm, c =1.972 9(2) nm , β =94.74(1)°, V =6.491 2(14) nm 3, Z =4. The toluene molecule was included in the macrocycle cavity. The calixanene is of a pinched cone conformation.
基金National Natural Science Foundation of China (No.50905169)
文摘This paper describes the detailed desi gn of data acquisition device with multi-channel and high-precision for aerosp ace.Based on detailed analysis of the advantages and disadvantages of tw o common acquisition circuits,the design factors of acquisition device focus o n accuracy,sampling rate,hardware overhead and design space.The me chanical structure of the system is divided into different card layers according to different functions and the structure has the characteristics of high reliability,conveni ence to install and scalability.To ens ure reliable operation mode,the interface uses the optocoupler isolated from th e e xternal circuit.The transmission of signal is decided by the current in the cur rent loop that consists of optocouplers between acquisition device and t est bench.In multi-channel switching circuit,by establ ishing analog multiplexer model,the selection principles of circuit modes are given.