Although tumor gene therapy falls behind its clinical use, the combination of irradiation and gene therapy is full ofpromise in cancer therapy based on traditional radiotherapy, chemotherapy and surgery. We have terme...Although tumor gene therapy falls behind its clinical use, the combination of irradiation and gene therapy is full ofpromise in cancer therapy based on traditional radiotherapy, chemotherapy and surgery. We have termed it as radiogenic therapy. This review focuses on the following aspects of radiogenic therapy in recent years: improvement of gene transfer efficiency by irradiation, radiotherapy combined with cytokine gene delivery or enhancement of the immunity of tumor cells by transgene, direct stimulation by radiation toproduce cytotoxic agents, increase of tumor cell radiosensitivity in gene therapy by controlling the radiosensitivity genes and adjusting the fraction dose and interval of radiation so as to achieve the optimum antitumor effect while reducing the normal tissue damage, radioprotective gene therapy enhancing radiation tumor killing effect while protecting the normal tissue and organs with transgene using transfer vectors.展开更多
The dependence of the ratio R1 for transfer ionization to single capture for Cq+, Nq+, Oq+, Neq+ ions on Ne target upon the electronic structure of the projectile is studied. For Aq+-Ne collisions the ratio R1 decreas...The dependence of the ratio R1 for transfer ionization to single capture for Cq+, Nq+, Oq+, Neq+ ions on Ne target upon the electronic structure of the projectile is studied. For Aq+-Ne collisions the ratio R1 decreases as the atomic number Z of the projectile increases for q=4,5,6,7 sequences which provides strong evidence for the increase of the binding energy of the target valence electron after single electron capture. The increase in binding energy depends both upon the atomic number of the projectile and the target atom.展开更多
Background Several million subclavian-vein catheters are placed in patients each year to enable caregivers to administer chemotherapy, total parenteral nutrition, or long-term antibiotics or to manage preoperative fl...Background Several million subclavian-vein catheters are placed in patients each year to enable caregivers to administer chemotherapy, total parenteral nutrition, or long-term antibiotics or to manage preoperative fluids. Subclavian venipuncture requires the position of a deep vein to be identified with only surface landmarks. But the traditional right subclavian vein (RSV) catheterization (primitive procedures) is not the answer for all patients. The precise location of the vein is not known, and it is important to select the most appropriate method to achieve central venous access safely in any given patient. To modify the primitive procedures of the RSV catheterization for greater success and reduce the complications, anatomic studies and ultrasonography were conducted and clinical applications were validated. Methods Anatomical observation and measurement of the RSV and its adjacent structures were performed on 20 adult cadavers according to modified procedures. The RSV catheterization of 2900 cases was carried out by the modified procedure, 500 of these cases were observed by ultrasonography after the operation. Results The anatomical studies and clinical application showed that the insertion point differs from the bodily form of fatness or leptosome. The clinical data revealed that in the 2900 cases which were performed with the modified approach, the success rate was 98.90% (2868 cases), the failure rate was 1.10% (32 cases), and the complication rate is 0.79% (23 cases), and the catheterization time is (31.2±10.5) minutes. Five hundred and sixty cases of the RSV catheterization were carried out by the recommended insertion procedure; the results were compared with the modified approach and the traditional approach. The successful rate of the traditional approach was 73.0%, of which the complication rate was 6.1%; the two approaches were significantly different (successful rate: χ 2=626.642, P <0.01; complication rate: χ 2=80.708, P <0.01). Conclusions The modified RSV catheterization is characterized with a higher success rate and less complications, and the insertion procedure differs from the bodily form of fatness or leptosome.展开更多
The spectra of highly charged titanium ions produced by the interaction of 120 MeV titanium ions with carbon foil were investigated with the so-called beam-foil technique using the HI-13 tandem accelerator in China In...The spectra of highly charged titanium ions produced by the interaction of 120 MeV titanium ions with carbon foil were investigated with the so-called beam-foil technique using the HI-13 tandem accelerator in China In- stitute of Atomic Energy. Spectral lines emitted from fifty- three excited energy levels were observed in the wavelength range 120—220 ?, among which eleven lines were new. Our experimental results show good agreement with the results of laser plasma experiments, and are in reasonable agreement with theoretical calculations.展开更多
基金Supported by the Key Basic Research Project of Science and Technology Ministry of China, 2003CCB00200
文摘Although tumor gene therapy falls behind its clinical use, the combination of irradiation and gene therapy is full ofpromise in cancer therapy based on traditional radiotherapy, chemotherapy and surgery. We have termed it as radiogenic therapy. This review focuses on the following aspects of radiogenic therapy in recent years: improvement of gene transfer efficiency by irradiation, radiotherapy combined with cytokine gene delivery or enhancement of the immunity of tumor cells by transgene, direct stimulation by radiation toproduce cytotoxic agents, increase of tumor cell radiosensitivity in gene therapy by controlling the radiosensitivity genes and adjusting the fraction dose and interval of radiation so as to achieve the optimum antitumor effect while reducing the normal tissue damage, radioprotective gene therapy enhancing radiation tumor killing effect while protecting the normal tissue and organs with transgene using transfer vectors.
文摘The dependence of the ratio R1 for transfer ionization to single capture for Cq+, Nq+, Oq+, Neq+ ions on Ne target upon the electronic structure of the projectile is studied. For Aq+-Ne collisions the ratio R1 decreases as the atomic number Z of the projectile increases for q=4,5,6,7 sequences which provides strong evidence for the increase of the binding energy of the target valence electron after single electron capture. The increase in binding energy depends both upon the atomic number of the projectile and the target atom.
文摘Background Several million subclavian-vein catheters are placed in patients each year to enable caregivers to administer chemotherapy, total parenteral nutrition, or long-term antibiotics or to manage preoperative fluids. Subclavian venipuncture requires the position of a deep vein to be identified with only surface landmarks. But the traditional right subclavian vein (RSV) catheterization (primitive procedures) is not the answer for all patients. The precise location of the vein is not known, and it is important to select the most appropriate method to achieve central venous access safely in any given patient. To modify the primitive procedures of the RSV catheterization for greater success and reduce the complications, anatomic studies and ultrasonography were conducted and clinical applications were validated. Methods Anatomical observation and measurement of the RSV and its adjacent structures were performed on 20 adult cadavers according to modified procedures. The RSV catheterization of 2900 cases was carried out by the modified procedure, 500 of these cases were observed by ultrasonography after the operation. Results The anatomical studies and clinical application showed that the insertion point differs from the bodily form of fatness or leptosome. The clinical data revealed that in the 2900 cases which were performed with the modified approach, the success rate was 98.90% (2868 cases), the failure rate was 1.10% (32 cases), and the complication rate is 0.79% (23 cases), and the catheterization time is (31.2±10.5) minutes. Five hundred and sixty cases of the RSV catheterization were carried out by the recommended insertion procedure; the results were compared with the modified approach and the traditional approach. The successful rate of the traditional approach was 73.0%, of which the complication rate was 6.1%; the two approaches were significantly different (successful rate: χ 2=626.642, P <0.01; complication rate: χ 2=80.708, P <0.01). Conclusions The modified RSV catheterization is characterized with a higher success rate and less complications, and the insertion procedure differs from the bodily form of fatness or leptosome.
文摘The spectra of highly charged titanium ions produced by the interaction of 120 MeV titanium ions with carbon foil were investigated with the so-called beam-foil technique using the HI-13 tandem accelerator in China In- stitute of Atomic Energy. Spectral lines emitted from fifty- three excited energy levels were observed in the wavelength range 120—220 ?, among which eleven lines were new. Our experimental results show good agreement with the results of laser plasma experiments, and are in reasonable agreement with theoretical calculations.