ADAPTIVE CALIBRATION OF I AND Q MISMATCH IN QUADRATURE RECEIVER 被引量:3
1
作者 YangXuexian ZhangQunying 《Journal of Electronics(China)》 2002年第2期187-191,共5页
The mismatch of ill-phase and quadrature channels in quadrature receiver affects and constrains radar detection performance in coherent radar. It is necessary to keep the in-phase and quadrature branches symmetrical. ... The mismatch of ill-phase and quadrature channels in quadrature receiver affects and constrains radar detection performance in coherent radar. It is necessary to keep the in-phase and quadrature branches symmetrical. In this letter, an adaptive method t.o detect imbalance parameters is derived by means of evaluating channel errors from the received signal .sequences. No matter how the bias degree of the gain and phase errors in I/Q channels are. the proposed adaptive scheme can obtain good calibration results. And the inquired calculations are only a few multiplications and additions. No need of a special test signal, the introduced method is simple to implement and easy to operate. 展开更多
关键词 Quadrature receiver I/Q mismatch Adaptive' calibration
在线阅读 下载PDF
RESEARCH ON CYLINDRICAL BOX TYPE WINDOWS USED TO TRANSMIT HIGH POWER CW 被引量:1
2
作者 LinFumin DingYaogen +1 位作者 ShenBin XuShouxi 《Journal of Electronics(China)》 2004年第5期392-400,共9页
The formula for calculating the threshold of average transmitting power of cylindrical TE11 mode window is revised by accurate deduction and a practical method for calculating the temperature increment of the dielectr... The formula for calculating the threshold of average transmitting power of cylindrical TE11 mode window is revised by accurate deduction and a practical method for calculating the temperature increment of the dielectric disk in cylindrical box type window is given. Meanwhile,a typical cylindrical box type window is calculated and used as an example to discuss the power capacity, the special harmfulness and elimination of ghost mode resonance when the window is used to transmit high power Continuous Wave(CW). 展开更多
关键词 High power Continuous Wave(CW) Microwave window Dielectric disk in window RF loss Power capacity Ghost mode
在线阅读 下载PDF
HIGH-ORDER NYSTRM METHOD FOR THE EFIE OF EM SCATTERING PROBLEMS 被引量:1
3
作者 ZhangXiaojuan 《Journal of Electronics(China)》 2004年第6期476-481,共6页
Nystrm method is a new method for solving electromagnetic scattering problems. This paper gives the detailed description on high-order Nystrm method used for the electric field integral equation of electromagnetic sca... Nystrm method is a new method for solving electromagnetic scattering problems. This paper gives the detailed description on high-order Nystrm method used for the electric field integral equation of electromagnetic scattering problems. The numerical solutions of two examples are correct compared with Method Of Moment(MOM). 展开更多
关键词 EM Scattering High-order Nystrm method
在线阅读 下载PDF
Effects of Substrates with Different Dielectric Parameters on Left-Handed Frequency of Left-Handed Materials 被引量:2
4
作者 全保刚 李超 +4 位作者 隋强 李俊杰 刘伍明 李芳 顾长志 《Chinese Physics Letters》 SCIE CAS CSCD 2005年第5期1243-1245,共3页
原文传递
Electron Density Fluctuation in a Dusty Plasma 被引量:1
5
作者 李芳 《Chinese Physics Letters》 SCIE CAS CSCD 2002年第2期214-216,共3页
原文传递
Top—Higgs and the Process e^+e^— → vvtt
6
作者 YUEChong-Xing YANGHua 《Communications in Theoretical Physics》 SCIE CAS CSCD 2002年第4期447-449,共3页
We discuss the contributions of the top-Higgs ht0 predicted by topcolor-assisted technicolor (TC2) models to the process e+e- → vvtt.We find that the contributions are very large.For mht = 400 GeV and ε = 0.01,the p... We discuss the contributions of the top-Higgs ht0 predicted by topcolor-assisted technicolor (TC2) models to the process e+e- → vvtt.We find that the contributions are very large.For mht = 400 GeV and ε = 0.01,the production cross section of this process can reach 11.2 fb,which may be detected in thc future high energy e+e- collider experiments.The process e+ e- → vvtt can be used to test experimentally the signal of TC2 models. 展开更多
关键词 电弱统一机制 上Higgs粒子 正负电子淹没过程
在线阅读 下载PDF
DEVELOPMENT OF AN S-BAND KLYSTRON WITH BANDWIDTH OF 11%
7
作者 WangYong DingYaogen ZhangJian WangShuguo XuMiaoling JiangZhenbo LuXi 《Journal of Electronics(China)》 2004年第6期522-524,共3页
This letter introduces the design ideas, simulation and test results of an S-band klystron with bandwidth of 11%, which was developed by the Institute of Electronics, Chinese Academy of Sciences (IECAS). On the peak p... This letter introduces the design ideas, simulation and test results of an S-band klystron with bandwidth of 11%, which was developed by the Institute of Electronics, Chinese Academy of Sciences (IECAS). On the peak power level of 800 kW, the efficiency of klystron is more than 30%; the gain is more than 41 dB; the equal-driving relative instantaneous bandwidth is over 11%; the average power is larger than 8 kW, and the power fluctuation within bandwidth is less than 1.5 dB. 展开更多
关键词 S-band klystron Bandwidth of 11% Lower peak power
在线阅读 下载PDF
ELECTRIC FIELD SENSORS BASED ON MEMS TECHNOLOGY
8
作者 GongChao XiaShanhong DengKai BaiQiang ChenShaofeng 《Journal of Electronics(China)》 2005年第4期443-448,共6页
The design and optimization of two types of novel miniature vibrating Electric Field Sensors (EFSs) based on Micro Electro Mechanical Systems (MEMS) technology are presented.They have different structures and vibratin... The design and optimization of two types of novel miniature vibrating Electric Field Sensors (EFSs) based on Micro Electro Mechanical Systems (MEMS) technology are presented.They have different structures and vibrating modes. The volume is much smaller than other types of charge-induced EFSs such as field-mills. As miniaturizing, the induced signal is reduced enormously and a high sensitive circuit is needed to detect it. Elaborately designed electrodes can increase the amplitude of the output current, making the detecting circuit simplified and improving the signal-to-noise ratio. Computer simulations for different structural parameters of the EFSs and vibrating methods have been carried out by Finite Element Method (FEM). It is proved that the new structures are realizable and the output signals are detectable. 展开更多
关键词 Electric Field Sensor (EFS) MicroElectroMechanical Systems (MEMS) Finite Element Method (FEM)
在线阅读 下载PDF
Study of nano biosensors
9
作者 CAIXin-xia 《中国医学工程》 2005年第2期154-154,共1页
Point of care testing (POCT) based on biosensors has been recently received increasingly interesting in the world. Using biosensor technology for biomedical analysis has demonstrated many advantages. However, low cost... Point of care testing (POCT) based on biosensors has been recently received increasingly interesting in the world. Using biosensor technology for biomedical analysis has demonstrated many advantages. However, low cost and high accurate biosensors for clinical analysis, particularly for POCT is still a common problem for commercialization of the most biosensors. In this work, it has the goals to develop materials (including nano materials) and methods for producing disposable biosensors capable with low cost, high reliability & sensitivity, robustness, low volume sample, and creating portable sensor systems (Figure 1) for testing human metabolites, biochemical markers without reagents. On top of the use of electrochemical method and Nano, MEMS technology, hemoglobin, creative kinase, alanine aminotransferas (ALT), Aspartate Aminotransferase (AST), glucose, lactate, ketone (β-Hydroxybutyrate), cholesterol have been tested using thin film electrode biosensors, modified with nanoporous and nanostructured materials (Figure 2). The electrode has high surface-to-volume ratio and excellent hydrophilicity, thus the electrode possesses high catalytic activities for electrolytic processes and are ideal candidates for biosensors. It is significant for the applications in clinical diagnosis of diabetes, cardiovascular diseases, home health care, sports, physical performance of athletes, blood screen. Glycated hemoglobin, creatine kinase MB (CK-MB), myoglobin, cardiac troponin I (cTnI), cardiac troponin T (cTnT) are interesting to be tested for the next study. 展开更多
关键词 纳米生物传感器 POCT 工艺技术 生物科学
暂未订购
A Conjecture on the Origin of Dark Energy
10
作者 高山 《Chinese Physics Letters》 SCIE CAS CSCD 2005年第3期783-784,共2页
原文传递
Verification and Calculation of Negative Refractive Indices of a Meta-Material by Numerical Method
11
作者 隋强 刘慈香 +1 位作者 李超 李芳 《Chinese Physics Letters》 SCIE CAS CSCD 2005年第8期2073-2076,共4页