期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Temporal Trends in Radiation Dose Associated with Coronary Computed Tomography Angiography
1
作者 Paolo Marraccini Alessandro Mazzarisi +7 位作者 Clara Carpeggiani Mathis Schluter Marco Brambilla Massimiliano Bianchi Lorenzo Faggioni Giuseppe Coppini Carlo Bartolozzi Eugenio Picano 《Open Journal of Radiology》 2014年第1期101-110,共10页
Background: In 2010, the International Atomic Energy Agency launched the “3A’s campaign” as an effective tool for primary cancer prevention. In 2011, the American Association of Physicists in Medicine recommended t... Background: In 2010, the International Atomic Energy Agency launched the “3A’s campaign” as an effective tool for primary cancer prevention. In 2011, the American Association of Physicists in Medicine recommended the size specific dose estimate (SSDE). Objectives: To audit doses of Coronary CT Angiography (Coronary CTA) in tertiary care referral center. Methods: We reviewed 998 consecutive Coronary CTA (from 2007 to 2012). Doses (CTDIvol mGy), DLP (mGy*cm), effective dose (DLP*0.014, mSv) were on-line archived. SSDE was estimated retrospectively. Appropriateness score was evaluated for exams performed from the 2010. Results: Overall median dose per Coronary CTA was 49.7 mGy for CTDIvol, 55.5 mGy for SSDE, 994.96 mGy*cm for DLP, 13.9 mSv for effective dose. Median DLP decreased over time (1452.94 in 2007, 1605.56 in 2008, 1113.49 in 2009, 759.99 in 2010, 448.61 in 2011 and 497.88 mGy*cm in 2012, p < 0.0001). SSDE was proportional to the size dependent factor (SDF);in patients with SDF > 1 (88%) CTDIvol underestimated SSDE (48.49 vs 57.19 mGy), whilst in patients with SDF < 1 (12%) CTDIvol overestimated SSDE (56.46 vs 50.3 mGy). Scans were appropriate in 58%, uncertain in 24%, and inappropriate in 18% of cases. Doses were similar in appropriate, uncertain or inappropriate examinations and in excellent-to-good (81%) vs. sufficient-to-poor (19%) image quality exams. Conclusions: Coronary CTA reference doses can be very misleading. SSDE can allow individual technique optimization. The dose is similar in appropriate and inappropriate examinations, and unrelated to image quality. The rate of inappropriate examinations is still too high even after dissemination of guidelines. 展开更多
关键词 ISCHEMIC Heart Disease X RAY CARDIAC COMPUTED Tomography CARDIOVASCULAR Imaging Radiation DOSING
暂未订购
An Assessment of Ingestion Dose due to the Intake of ^210Po and ^210Pb through Drinking Water of Eloor, Ernakulam District, Kerala, India
2
作者 A. G. Umadev Dhanya Balakrishnan +5 位作者 Jose P. Abraham M. Rajagopalan M. George P. Dharmalingam Sujatha Radhakrishnan M. Harikumar 《Journal of Chemistry and Chemical Engineering》 2011年第10期903-908,共6页
The present study aims at measuring the activity concentrations of ^210Po and ^210Pb in the potable water of Eloor, a major industrial belt in the Ernakulam district of Kerala, India with an aim of evaluating resultan... The present study aims at measuring the activity concentrations of ^210Po and ^210Pb in the potable water of Eloor, a major industrial belt in the Ernakulam district of Kerala, India with an aim of evaluating resultant ingestion dose to critical population. The industrial units located in Eloor discharge their treated effluents into the river Periyar and the surrounding environs. The two major industries of interest with respect to NORMs are the fertilizer plant, processing rock phosphate and the monazite processing plant, which had been in operation for the last 50 years. For sampling, Eloor region was divided into four zones and a total of 55 water samples from different locations were collected and analysed as per standard analytical procedure manual of BARC. The ^210Po concentration ranged between 0.3 to 4.7 mBq.L^-1 and ^210Pb ranged from 0.6 to 4.3 mBq.L^-1. All values are well below the limit of 0.1 Bq.Ll recommended by World Health Organization. Statistical analysis shows a good co-relation between ^210Po and ^210Pb in the water samples analyzed and the mean activity concentration is found to be relatively high in the western region of Eloor compared to other regions. The annual effective dose equivalent to man from ^210Po and ^210Pb through drinking water intake were estimated and found to be 1.13 μSv.y^-1 and 0.99 μSv.y^-1 respectively, which is well below the reference level of committed effective dose (100 μSv.y^-1) recommended by WHO. 展开更多
关键词 ^210Po and ^210Pb activity concentration groundwater Eloor drinking water quality dose calculations
在线阅读 下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部