期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Prediction of Swelling Kinetics of Expansive Soils of Rufisque (Senegal, West Africa) 被引量:1
1
作者 Papa Sanou Faye Issa Ndoye +3 位作者 Mapathé Ndiaye Abib Tall Ibrahima Khalil Cissé Jean Pierre Magnan 《Open Journal of Civil Engineering》 2017年第2期267-281,共15页
The disorders caused by the swelling of the soil on the structures have been observed for several years in the city of Rufisque. This article presents the results of the study of swelling kinetics of expansive soils i... The disorders caused by the swelling of the soil on the structures have been observed for several years in the city of Rufisque. This article presents the results of the study of swelling kinetics of expansive soils in Rufisque and their prediction based on the hyperbolic rule. The odometer is used as an instrument for measuring swelling and the tests are carried out on some intact samples at their sampling water content. The present study shows that in Rufisque the most swelling layer is marl. The results show two phases of development. The first phase is very fast and represents 77% of the final deformation and the second one is slower. The prediction of the issue by the hyperbolic rule shows that it underestimates the first phase but gives a good prediction of the second phase of the swelling rate. There is a good correlation between the final swelling rates. However, the model gives a bad approximation of the half-swelling time. 展开更多
关键词 MARLS MARLS Clays Clays KINETIC SWELLING Expansive Soils HYPERBOLIC Rule Rufisque
暂未订购
A Simple Theoretical Approach of Aqueous Solutions of Salts and Organic Solvents in Paper Chromatography
2
作者 Jacques P. Viejo 《American Journal of Analytical Chemistry》 2019年第8期255-285,共31页
The purpose of this study is to determine the properties of the solvents responsible of the chromatographic phenomenon. A simple and homogeneous system of ascending chromatography on paper is described, allowing varyi... The purpose of this study is to determine the properties of the solvents responsible of the chromatographic phenomenon. A simple and homogeneous system of ascending chromatography on paper is described, allowing varying only one of the factors constituting it. This method made it possible to determine constants by means of a simple equation. The validity of the method is deduced from the good agreement between its mathematical expression and the experimental values obtained. 展开更多
关键词 PAPER CHROMATOGRAPHY AQUEOUS SOLVENT Organic SOLVENT Theory
在线阅读 下载PDF
Evaluation of an Ultrasound-Guided Focused Ultrasound CMUT Probe for Targeted Therapy Applications
3
作者 Dominique Gross Mathieu Legros +1 位作者 Philippe Vince Dominique Certon 《Open Journal of Applied Sciences》 2018年第1期25-45,共21页
Capacitive Micromachined Ultrasonic Transducer (CMUT) technology, which has been widely studied in the field of medical imaging, possesses strong design flexibility due to its manufacturing process. Many applications ... Capacitive Micromachined Ultrasonic Transducer (CMUT) technology, which has been widely studied in the field of medical imaging, possesses strong design flexibility due to its manufacturing process. Many applications could benefit from this unique feature, especially those that require different operating ultrasonic frequencies. This article reports on the characterization of the therapeutic low-frequency field provided by an ultrasound-guided focused ultrasound CMUT probe that is connected to a custom ultrasonic scanner for hyperthermia applications. The study begins by mapping the focused ultrasonic beam in the vicinity of the focal spot and a parametric analysis providing the maximum peak-to-peak (PTP) pressure delivered by the probe under different acoustic conditions. The measured maximum PTP pressure at the targeted operating frequency of 1 MHz is 3 MPa, with a maximum of 3.6 MPa at 1.25 MHz. Based on an in vitro setup found in the literature, the temperature elevation at the focal point was measured, showing results in agreement with the targeted applications (max. ΔT = 7.5°C). The article concludes with a reliability study considering the delivered pressure and the self-heating of the CMUT probe: the results show the good stability of the pressure amplitude over 1.8 × 109 cycles at a duty cycle of 40%, with a moderate internal heating of 3°C. 展开更多
关键词 Capacitive Micromachined ULTRASONIC Transducers CMUT USgFUS TARGETED THERAPY
暂未订购
上一页 1 下一页 到第
使用帮助 返回顶部