Endoscopic ultrasound guided radiofrequency ablation for pancreatic tumors: A critical review focusing on safety, efficacy and controversies 被引量:2
1
作者 Tawfik Khoury Wisam Sbeit Bertrand Napoléon 《World Journal of Gastroenterology》 SCIE CAS 2023年第1期157-170,共14页
The role of endoscopic ultrasound(EUS)in the last two decades has shifted from a diagnostic tool to an important therapeutic tool treating mainly pancreatobiliary disorders.In recent years,its applications for treatin... The role of endoscopic ultrasound(EUS)in the last two decades has shifted from a diagnostic tool to an important therapeutic tool treating mainly pancreatobiliary disorders.In recent years,its applications for treating pancreatic diseases have broadened,including the implementation of radiofrequency ablation(RFA),which has been traditionally used for treating solid tumors.In this critical indepth review,we summarized all the papers throughout the literature regarding EUS-RFA for pancreatic neuroendocrine neoplasms,adenocarcinoma,and pancreatic cystic lesions.Overall,for pancreatic neuroendocrine neoplasms we identified 16 papers that reported 96 patients who underwent EUS-RFA,with acceptable adverse events that were rated mild to moderate and a high complete radiological resolution rate of 90%.For pancreatic adenocarcinoma,we identified 8 papers with 121 patients.Adverse events occurred in 13%of patients,mostly rated mild.However,no clear survival benefit was demonstrated.For pancreatic cystic lesions,we identified 4 papers with 38 patients.The adverse events were mostly mild and occurred in 9.1%of patients,and complete or partial radiological resolution of the cysts was reported in 36.8%.Notably,the procedure was technically feasible for most of the patients.Nevertheless,a long road remains before this technique finds its definite place in guidelines due to several controversies.EUS-RFA for pancreatic tumors seems to be safe and effective,especially for pancreatic neuroendocrine neoplasms,but multicenter prospective trials are needed to consider this treatment as a gold standard. 展开更多
关键词 Endoscopic ultrasound Radiofrequency ablation EFFICACY SAFETY PANCREAS TUMORS
暂未订购
Endoscopic therapy using a self-expandable metallic stent with an anti-migration system for postorthotopic liver transplantation anastomotic biliary stricture
2
作者 Larissa Wermelinger Pinheiro Fernanda Prata Martins +3 位作者 Gustavo Andrade De Paulo Mðnica Lúcia Campos Contini Angelo Paulo Ferrari Ermelindo Della Libera 《World Journal of Gastrointestinal Endoscopy》 2022年第9期547-554,共8页
BACKGROUND Endoscopic therapy using multiple plastic stents(MPSs)is the standard therapy for postorthotopic liver transplantation(p-OLT)anastomotic biliary stricture(ABS).However,this approach demands repeated procedu... BACKGROUND Endoscopic therapy using multiple plastic stents(MPSs)is the standard therapy for postorthotopic liver transplantation(p-OLT)anastomotic biliary stricture(ABS).However,this approach demands repeated procedures.Recent studies us-ing fully covered self-expandable metallic stents(FCSEMS)have shown en-couraging results,but migration occurs in 10%to 40%of cases.The objective of this retrospective study was to evaluate the efficacy of endoscopic treatment using FCSEMS with an anti-migration system(Am-FCSEMS)in patients with p-OLT ABS.AIM To evaluate the efficacy of endoscopic treatment using an Am-FCSEMS in patients with p-OLT ABS.METHODS This study was conducted in a private tertiary care centre in S?o Paulo,Brazil and was approved by our institution's Human Research Committee.From April 2018 to October 2020,regardless of previous endoscopic treatment(MPS or FCSEMS),17 patients with p-OLT ABS and indications for endoscopic therapy were included in this study.The exclusion criteria were pregnancy,nonanastomotic biliary or hilar stricture,hepatic artery stenosis/thrombosis,isolated biliary fistulae,a distance shorter than 2 cm from the stricture to the hepatic hilum,and patient refusal.The primary endpoint was the efficacy of p-OLT ABS endoscopic treatment using an Am-FCSEMS that re-mained in place for a 12-mo period.Biliary sphincterotomy was performed in patients with native papilla,and an Am-FCSEMS(10 mm in final diameter and 60 or 80 mm in length)was placed(Hanarostent TM MI Tech,Co).Balloon stricture dilation was performed only if necessary to introduce the stent.RESULTS Three patients were excluded due to loss to follow-up before stent removal.Among the 14 patients included and followed,7 were women,and the average age was 56 years(range:28-76).The average period of Am-FCSEMS placement was 362±109 d.Technical success occurred in all 14 patients(100%).There were no cases of distal stent migration.Complete resolution of the stricture occurred in 13/14 patients(92.85%).Adverse events occurred in 3/14 patients(21.42%):2 patients with mild acute pancreatitis(14.28%)and 1 patient(7.14%)with stent dysfunction(occlusion by biliary sludge and stones,which was treated endoscopically without the need for stent removal).No deaths occurred related to therapy.All stents were removed using foreign body forceps or snares without difficulty.After Am-FCSEMS removal,all 13 patients who had ABS resolution were followed-up for an average of 411±172 d,and there was no stricture recurrence or need for further endoscopic therapy.CONCLUSION In this retrospective study,endoscopy therapy using an Am-FCSEMS for p-OLT ABS was safe and effective,with a high stricture re-solution rate that was probably due to the absence of stent migration. 展开更多
关键词 Liver transplantation ENDOSCOPY Endoscopic retrograde cholangiopancreatography Biliary strictures Self-expandable metallic biliary stents