Renewable Electricity Generation: Solution to GHG Emissions in Nigeria Telecom Industry
1
作者 Rilwan Olaolu Oliyide Mojisola F. Olugbemi 《World Journal of Engineering and Technology》 2024年第4期885-894,共10页
Continual release of greenhouse gases emission into the atmosphere is the main cause of climate change. Climate change and its consequent impacts have been source of concerns for all as it directly affects the sustain... Continual release of greenhouse gases emission into the atmosphere is the main cause of climate change. Climate change and its consequent impacts have been source of concerns for all as it directly affects the sustainability of life on the planet earth. Greenhouse gases emission must be reduced in all sectors to avert the inherent dangers of climate change. This work investigates the emission of greenhouse gases in the Nigerian Telecoms industry. Empirical data from Nigerian Telecoms industry are gathered and technically evaluated to investigate the carbon footprint of operations in the sector. The work further estimates the environmental gains in terms of reduction in greenhouse gases emission and economic gains in terms of reduction in fuel costs achievable with deploying renewable energy solution (solar-powered inverter with backup batteries) to power base stations. 展开更多
关键词 Telecoms Greenhouse Gases Base Stations Renewable Energy Climate Change Power Inverter
在线阅读 下载PDF
Management of Charging Load of Electric Vehicles for Optimal Capacity Utilisation of Distribution Transformers
2
作者 Rilwan Olaolu Oliyide Liana M. Cipcigan 《Journal of Power and Energy Engineering》 2021年第11期60-79,共20页
A de-centralised load management technique exploiting the flexibility in the charging of Electric Vehicles (EVs) is presented. Two charging regimes are assumed. The Controlled Charging Regime (CCR) between 16:30 hours... A de-centralised load management technique exploiting the flexibility in the charging of Electric Vehicles (EVs) is presented. Two charging regimes are assumed. The Controlled Charging Regime (CCR) between 16:30 hours and 06:00 hours of the next day and the Uncontrolled Charging Regime (UCR) between 06:00 hours and 16:30 hours of the same day. During the CCR, the charging of EVs is coordinated and controlled by means of a wireless two-way communication link between EV Smart Charge Controllers (EVSCCs) at EV owners’ premises and the EV Load Controller (EVLC) at the local LV distribution substation. The EVLC sorts the EVs batteries in ascending order of their states of charge (SoC) and sends command signals for charging to as many EVs as the transformer could allow at that interval based on the condition of the transformer as analysed by the Distribution Transformer Monitor (DTM). A real and typical urban LV area distribution network in Great Britain (GB) is used as the case study. The technique is applied on</span></span><span><span><span style="font-family:""> </span></span></span><span><span><span style="font-family:"">the LV area when its transformer is carrying the future load demand of the area on a typical winter weekday in the year 2050. To achieve the load management, load demand of the LV area network is decomposed into Non-EV <span>load and EV load. The load on the transformer is managed by varying the EV load in an optimisation objective function which maximises the capacity uti</span>lisation of the transformer subject to operational constraints and non-disruption of daily trips of EV owners. Results show that with the proposed load management technique, LV distribution networks could accommodate high uptake of EVs without compromising the useful normal life expectancy of distribution transformers before the need for capacity reinforcement. 展开更多
关键词 Electric Vehicles Load Management EV Charge Controller EV Load Controller Distribution Transformer Monitor
暂未订购
Developing Operational Model for Heat Pumps as Space Heating and Domestic Hot Water Provider
3
作者 Rilwan Olaolu Oliyide Jose B. Hernandez 《Open Journal of Applied Sciences》 2024年第10期2880-2900,共21页
In the United Kingdom, means of meeting domestic heating is being electrified to decarbonise in effort to reduce the greenhouse gases emissions from the burning of natural gas. Therefore, the uptake of heat pumps is o... In the United Kingdom, means of meeting domestic heating is being electrified to decarbonise in effort to reduce the greenhouse gases emissions from the burning of natural gas. Therefore, the uptake of heat pumps is on the increase. The operation and working principle of heat pumps must be well understood in the investigations of their impacts on the grid and the grid assets, especially distribution transformers which could be overloaded due to higher peak load demand. This work develops an operational model of heat pumps as combined space heating and domestic hot water provider implemented in MATLAB. The developed operational model of heat pumps is adaptable and repeatable for different input parameters. The developed model is used to generate daily average demand profiles of heat pumps for a typical winter weekday and a typical summer weekday. The generated demand profiles of heat pumps by the developed model compared well with the demand profiles of heat pumps generated from actual field projects which are usually expensive and time-tasking. 展开更多
关键词 Heat Pumps Greenhouse Gases Space Heating Domestic Hot Water TRANSFORMER MATLAB
在线阅读 下载PDF
High Capacity Data Rate System:Review of Visible Light Communications Technology 被引量:5
4
作者 Augustus Ehiremen Ibhaze Patience Ebehiremen Orukpe Frederick Obataimen Edeko 《Journal of Electronic Science and Technology》 CAS CSCD 2020年第3期241-265,共25页
Wireless communications have become an integral part of global convergence as global connectedness has gradually become dependent on its efficient deployment.The need for"more-broadband"techniques in relatio... Wireless communications have become an integral part of global convergence as global connectedness has gradually become dependent on its efficient deployment.The need for"more-broadband"techniques in relation to the ever increasing growth rate of the data hungry society now necessitates novel techniques for the high-speed data transmission.While advancements have been made in this regard,the projection of having an eventual Internet of everything (IoE) deployment will result in an unimaginable transmission data rate requirement as huge data traffic will be conveyed per time within the communications network,which will require a capacity upgrade of the existing infrastructure.Visible light communications (VLCs),as an integral part of optical wireless communications (OWCs),have been reviewed in this article,having the capacity to extend the achievable data rate requirement of the wireless communications network.The technologies,techniques,and best practices have been presented alongside technology integration for the seamless high capacity wireless broadband deployment. 展开更多
关键词 Channel equalization heterogeneous network(HetNet) light-fidelity(Li-Fi) propagation link visible light communications(VLCs) wireless-fidelity(Wi-Fi)
在线阅读 下载PDF
Quadcopter Design for Payload Delivery 被引量:1
5
作者 Gordon Ononiwu Ondoma Onojo +1 位作者 Oliver Ozioko Onyebuchi Nosiri 《Journal of Computer and Communications》 2016年第10期1-12,共13页
This paper presents the design and implementation of a quadcopter capable of payload delivery. A quadcopter is a unique unmanned aerial vehicle which has the capability of vertical take-off and landing. In this design... This paper presents the design and implementation of a quadcopter capable of payload delivery. A quadcopter is a unique unmanned aerial vehicle which has the capability of vertical take-off and landing. In this design, the quadcopter was controlled wirelessly from a ground control station using radio frequency. It was modeled mathematically considering its attitude and altitude, and a simulation carried out in MATLAB by designing a proportional Integral Derivative (PID) controller was applied to a mathematical model. The PID controller parameters were then applied to the real system. Finally, the output of the simulation and the prototype were compared both in the presence and absence of disturbances. The results showed that the quadcopter was stable and able to compensate for the external disturbances. 展开更多
关键词 Quadcopter PID CONTROLLER PAYLOAD Delivery Unmanned AERIAL VEHICLE
在线阅读 下载PDF
Maximum Power Point Tracking Using the Incremental Conductance Algorithm for PV Systems Operating in Rapidly Changing Environmental Conditions 被引量:1
6
作者 Derek Ajesam Asoh Brice Damien Noumsi Edwin Nyuysever Mbinkar 《Smart Grid and Renewable Energy》 2022年第5期89-108,共20页
Maximum Power Point Tracking (MPPT) is an important process in Photovoltaic (PV) systems because of the need to extract maximum power from PV panels used in these systems. Without the ability to track and have PV pane... Maximum Power Point Tracking (MPPT) is an important process in Photovoltaic (PV) systems because of the need to extract maximum power from PV panels used in these systems. Without the ability to track and have PV panels operate at its maximum power point (MPP) entails power losses;resulting in high cost since more panels will be required to provide specified energy needs. To achieve high efficiency and low cost, MPPT has therefore become an imperative in PV systems. In this study, an MPP tracker is modeled using the IC algorithm and its behavior under rapidly changing environmental conditions of temperature and irradiation levels is investigated. This algorithm, based on knowledge of the variation of the conductance of PV cells and the operating point with respect to the voltage and current of the panel calculates the slope of the power characteristics to determine the MPP as the peak of the curve. A simple circuit model of the DC-DC boost converter connected to a PV panel is used in the simulation;and the output of the boost converter is fed through a 3-phase inverter to an electricity grid. The model was simulated and tested using MATLAB/Simulink. Simulation results show the effectiveness of the IC algorithm for tracking the MPP in PV systems operating under rapidly changing temperatures and irradiations with a settling time of 2 seconds. 展开更多
关键词 MODELING SIMULATION PV System Maximum Power Point Tracking (MPPT) Incremental Conductance Algorithm MATLAB/SIMULINK
暂未订购
Transient Stability Analysis of 33 KV Transmission Network of Egi Community, Nigeria
7
作者 Promise Elechi Christopher Okwuchukwu Ahiakwo Ugochukwu Nureedin Okwu 《Journal of Power and Energy Engineering》 2020年第3期18-35,共18页
Transient analysis of 33 KV power transmission line stability of Egi communi-ty is considered in this research work with the aim of reducing the frequency of fault occurrence and voltage collapse in the network. The s... Transient analysis of 33 KV power transmission line stability of Egi communi-ty is considered in this research work with the aim of reducing the frequency of fault occurrence and voltage collapse in the network. The supply is taken from Egi generating station located at Total Nigeria Limited Gas Plant Obite at voltage level of 33 KV to Egi communities. This work focuses on the transient nature of network stability since transient fault is the most dangerous in elec-trical systems. The swinging of the generator rotor in the event of transient three-phase short circuit fault can be monitored by the circuit breakers and the protective relays which causes mal-functioning of the circuit breakers and pro-tective relays leading to abnormal behavior of the network. Therefore, data obtained from the power station were used as a case study of Independent Power Producer (IPP) in Nigeria. For investigation of the power angle, angular velocity, rotor angle differential changes, and angular velocity differential changes, an electrical transient analyzer tool was employed (ETap version 16.00) for circuit breaker and protective relay time setting of (0.00, 0.05, 0.10, 0.15, 0.20, 0.25, 0.30, 0.35, 0.40, 0.45, 0.50, 0.55, 0.60). The work used the Trapezoidal numerical technique for data analysis. The graphs were plotted using Matlab R2015a and the results obtained showed that when a symmetrical three-phase short circuit fault occur at one or any of the feeders, the fault must be cleared as quick as possible through the coordination of the circuit breakers and protective relays. For this research work, 17 cycles corresponding to relay time setting of t = 0.34 s were recommended and at each cycle, changes in time with respect to changes in rotor angle, angular velocity, rotor differential and angular velocity differential were calculated on the power network simultaneously. The results demonstrated that the Trapezoidal method is numerically stable, accurate and has faster respond time when compared to Modified Euler and swing equation techniques in event of fault occurrence in network. 展开更多
关键词 Rotor Angle Transient Stability SWING Equation ANGULAR Speed Differential Changes Trapezoidal RULE Fault CLEARING TIME Critical CLEARING TIME
在线阅读 下载PDF
Enhancement of Transient Stability of the Nigeria 330 kV Transmission Network Using Fault Current Limiter
8
作者 Ignatius K. Okakwu Emmanuel A. Ogujor 《Journal of Power and Energy Engineering》 2017年第9期92-103,共12页
The dynamic responses of generators when subjected to disturbances in an interconnected power system have become a major challenge to power utility companies due to increasing stress on the power network. Since the oc... The dynamic responses of generators when subjected to disturbances in an interconnected power system have become a major challenge to power utility companies due to increasing stress on the power network. Since the occurrence of a disturbance or fault cannot be completely avoided, hence, when it occurs, control measures need to be put in place to limit the fault current, which invariably limit the level of the disturbances. This paper explores the use of Superconductor Fault Current Limiter (SFCL) to improve the transient stability of the Nigeria 330 kV Transmission Network. During a large disturbance, the rotor angle of the generator is enhanced by connecting a Fault Current Limiter (FCL) which reduces the fault current and hence, increases transient stability of the power network. In this study, the most affected generator was taken into consideration in locating the SFCL. The result obtained reveals that the Swing Curve of the generator without FCL increases monotonically which indicates instability, while the Swing Curve of the System with FCL reaches steady state. 展开更多
关键词 TRANSIENT Stability FAULT Current LIMITER NIGERIA 330 KV Power System
在线阅读 下载PDF
Medical Diagnosis Expert System for Malaria and Related Diseases for Developing Countries
9
作者 Kenneth Ikechukwu Nkuma-Udah Gloria Azogini Chukwudebe Emmanuel Nwabueze Ekwonwune 《E-Health Telecommunication Systems and Networks》 2018年第2期43-56,共14页
There is a strong need for cost-effective technologies to manage disease processes and thus reduce morbidity and mortality in the developing countries. Yet bringing intelligent healthcare informatics to bear on the du... There is a strong need for cost-effective technologies to manage disease processes and thus reduce morbidity and mortality in the developing countries. Yet bringing intelligent healthcare informatics to bear on the dual problems of reducing healthcare costs and improving quality and outcomes is a challenge even in countries with a reasonably developed technology infrastructure. This paper focused at how appropriate an ap-plication of Medical Diagnosis Expert System (MDES) is to manage diseases in developing countries. MDES is usually designed to enable clinicians to identify diseases and describe methods of treatment to be carried out taking into account the user capability. The MDES described here is implemented using the C Language Integrated Production System (CLIPS). The CLIPS is an expert system, which has a shell composed of four modules: the user interface, the explanation system, the inference engine and the knowledge base editor. In the system, a number of patient cases will be selected as prototypes and stored in a separate database. The knowledge is acquired from literature review, human experts and the internet of the specific domain and is used as a base for analysis, diagnosis and recommendations. 展开更多
关键词 DEVELOPING AFFORDABILITY APPROPRIATENESS Expert System Medical Diagnosis DEVELOPING COUNTRIES Artificial Intelligence
暂未订购
On the Comparison Analysis of Two 4G-WiMAX Base Stations in an Urban Sub-Saharan African Environment
10
作者 Eric Tutu Tchao Kwasi Diawuo Willie Ofosu 《通讯和计算机(中英文版)》 2013年第6期863-872,共10页
关键词 撒哈拉 环境 非洲 基站 无线宽带接入 城市 仿真结果 多媒体应用
在线阅读 下载PDF
Low-Cost Automated PV Panel Dust Cleaning System for Rural Communities
11
作者 Derek Ajesam Asoh Noel Nkwa Awangum 《Smart Grid and Renewable Energy》 CAS 2022年第8期173-199,共27页
Dust accumulation on photovoltaic (PV) panels degrades PV panels’ performance;leading to decreased power output and consequently high cost per generated kilowatt. Research addressing the severity of dust accumulation... Dust accumulation on photovoltaic (PV) panels degrades PV panels’ performance;leading to decreased power output and consequently high cost per generated kilowatt. Research addressing the severity of dust accumulation on PV panels has been ongoing since the 1940s, but proposed solutions have tended to increase the cost of PV systems either from oversizing or from cleaning the system. The objective of this work, therefore, is to design and implement a low-cost affordable automated PV panel dust cleaning system for use in rural communities of Sub-Saharan Africa (SSA);where financial resources are limited and significantly strained in meeting livelihood activities. Complete design and implementation details of a prototype system are provided for easy replication and capitalization on PV systems for sustainable energy needs. The system detects dust based on the innovative use of light-dependent resistors. Testing and observation of the system in operational mode reveal satisfactory performance;measured parameters quantify a power output increase of 33.76% as a result of cleaning dust off the PV panel used in the study. 展开更多
关键词 PV Panel Automated Dust Cleaning Arduino Microcontroller Light Dependent Resistor Dust Percentage Threshold Low-Income Rural Communities Sub-Sahara Africa
在线阅读 下载PDF
Design and Implementation of an Automatic Over/Undervoltage Protection System for Single-Phase Low Voltage Power Lines
12
作者 Derek Ajesam Asoh Lizette Nange Chia 《Journal of Power and Energy Engineering》 2022年第8期12-25,共14页
Today, many industrial and domestic electronic appliances and equipment (devices) are exposed to power disturbances such as voltage variations of the AC mains supply which often lead to damage of the electronic device... Today, many industrial and domestic electronic appliances and equipment (devices) are exposed to power disturbances such as voltage variations of the AC mains supply which often lead to damage of the electronic devices. As these devices are quite sensitive to power disturbances, there is a need for a tripping system that can help avoid any damage to devices in use. The objective of this work is to build a system that monitors line voltage and protects appliances from unacceptable voltage variations. The system consists of a tripping mechanism that monitors the input voltage and trips according to the limits provided. An Arduino Uno microcontroller is used to determine the voltage level through a voltage divider circuit. The system’s novelty and innovation lie in its flexibility. It offers the user the ability to define different overvoltage and undervoltage threshold values depending on the specific appliances used in the household. In operation, the system displays the voltage state (overvoltage, normal voltage, overvoltage) and alerts the user by sending an SMS via a GSM modem. The system is valuable for industrial and domestic applications, especially in developing economies such as those of Sub-Saharan Africa, where overvoltage and undervoltage are acute problems. 展开更多
关键词 OVERVOLTAGE UNDERVOLTAGE Simulation Arduino Microcontroller Tripping Mechanism Sub-Saharan Africa