期刊文献+
共找到46篇文章
< 1 2 3 >
每页显示 20 50 100
Statistical Analysis and Energy Planning of Electric Power Supply Systems with Intelligent Control
1
作者 Valentin Gyurov Vladimir Chikov 《Journal of Energy and Power Engineering》 2014年第4期702-708,共7页
The study presents possibilities for reconstruction of electric power supply systems in Bulgarian Black Sea resorts and possibilities to use statistical methods in energy planning. The paper shows the use of classic s... The study presents possibilities for reconstruction of electric power supply systems in Bulgarian Black Sea resorts and possibilities to use statistical methods in energy planning. The paper shows the use of classic statistical methods in combination with advanced digital measurement systems in order to obtain the correlation dependencies, nature of energy consumption and opportunities for energy forecasting. The main purpose of the study is to obtain statistical dependencies of the nature of power consumption and correlations between electricity consumption and ambient temperature in order to improve the accuracy of energy planning. The analysis includes application of energy management systems for proper energy planning, improving economical efficiency and reducing power and energy losses. 展开更多
关键词 Electric power supply energy planning energy forecasting.
在线阅读 下载PDF
Influences of Resistor-Type Superconducting Fault Current Limiter on Power System Transient Stability with Asymmetrical Short-Circuit Faults 被引量:1
2
作者 Xue-Ping Gu Zhi-Long Yang 《Journal of Electronic Science and Technology of China》 2008年第2期101-107,共7页
The transient stability of a single machine to infinite-busbar power system with resistortype superconducting fault current limiters (SFCL) is analyzed under asymmetrical short-circuit fault conditions. The SFCL is ... The transient stability of a single machine to infinite-busbar power system with resistortype superconducting fault current limiters (SFCL) is analyzed under asymmetrical short-circuit fault conditions. The SFCL is considered to introduce a resistance into the three-phase circuits when faults occur. Based on the power-angle curves for different short-circuit conditions of the single-line to ground, double-line to ground and line to line short-circuit faults, the influences of the SFCLs on transient stability are analyzed in detail. The time-domain simulation of transient stability is carried out to verify the analytical results. 展开更多
关键词 Equal-area criterion power angle curves power systems resistor-type SFCL transientstability.
在线阅读 下载PDF
Method for Determination of Optimal Installed Capacity of Renewable Sources of Energy by the Criterion of Minimum Losses of Active Power in Distribution System
3
作者 P. D. Lezhniuk V. A. Komar D. S. Sobchuk 《Energy and Power Engineering》 2014年第3期37-46,共10页
New method for determination of optimal placement and value of installed capacity of renewable source of energy (RES) by the criterion of minimum losses of active power, that allows taking into consideration the depen... New method for determination of optimal placement and value of installed capacity of renewable source of energy (RES) by the criterion of minimum losses of active power, that allows taking into consideration the dependence of RES on natural conditions of region, schedule of energy supply, parameters and configuration of distribution network is suggested in the paper. Results of computations of test scheme confirm the efficiency of the proposed method and its simplicity as compared with the methods considered in literature sources. 展开更多
关键词 Distributed Generation RENEWABLE Sources of ENERGY Minimum LOSSES of Active Power
暂未订购
Voltage Profile Enhancement and Power Loss Reduction with Economic Feasibility Using Small Capacity Distribution Transformers 被引量:1
4
作者 Rasool M.Imran Mohammed R.Saeed +5 位作者 Mohammed Amer Mohammed Osama A.Suhry Ihsan H.Abdulqadder Hasan Wahhab Salih Mohammed R.Almallah Firas M.F.Flaih 《Energy Engineering》 EI 2022年第6期2447-2467,共21页
Usually,rural areas can be electrified via three-phase distribution transformers with relatively large capacities.In such areas,low voltage lines are used for long distances,which cause power losses and voltage drop f... Usually,rural areas can be electrified via three-phase distribution transformers with relatively large capacities.In such areas,low voltage lines are used for long distances,which cause power losses and voltage drop for different types of consumers.Reducing losses and improving voltage profiles in rural distribution networks are significant challenges for electricity distribution companies.However different solutions were proposed in the literature to overcome these challenges,most of them face difficulties when applied in the conventional distribution network.To address the above issues,an applicable solution is proposed in this paper by installing a number of small-capacity distribution transformers instead of every single large-capacity transformer in rural areas.The proposed approach is implemented in the branch network of Al-Hoqool village,which belongs to the Nineveh distribution network.The network has been inspected on-site,drawn,and analyzed using the electrical systems analysis program(ETAP).The analysis showed that using the single-phase pole-mounted transformers can improve the voltage in the network’s end by 29%and enhance the voltage profile for all consumers.The analysis has also demonstrated that the modification can reduce the total power losses by 78%compared to the existing network.Concerning the economic aspect,the payback period for the proposed network is assigned to be 20 months. 展开更多
关键词 Single-phase pole-mounted transformer three-phase transformer power losses voltage profile distribution networks
在线阅读 下载PDF
A Novel Model Calculated Distribution Systems Planning Intergrated Distribution Generators for Competitive Electricity Markets 被引量:1
5
作者 V. V. Thang N. T. D. Thuy +1 位作者 D. Q. Thong B. Q. Khanh 《Journal of Software Engineering and Applications》 2013年第3期42-47,共6页
Recently, the distributed generator (DG) has been successfully studied and applied in distribution system at many countries around the world. Many planning models of the DG integrated distribution system have been pro... Recently, the distributed generator (DG) has been successfully studied and applied in distribution system at many countries around the world. Many planning models of the DG integrated distribution system have been proposed. These models can choose the optimization locations, capacities and technologies of DG with the objective function minimizing power loss, investment costs or total life cycle costs of the investment project. However, capacity of DG that uses renewable energy resources is natural variability according to primary energy. This study proposed a planning model of optimized distribution system that integrates DG in the competitive electricity market. Model can determine equipment sizing and timeframe requiring for upgrading equipment of distribution system as well as select DG technologies with power variable constraints of DG. The objective function is minimizing total life cycle cost of the investment project. The proposed model is calculated and tested for a 48-bus radial distribution system in the GAMS programming language. 展开更多
关键词 COMPETITIVE Electricity MARKETS (CEM) Distributed Generators (DG) DISTRIBUTION Systems (DS) PLANNING
在线阅读 下载PDF
Assessment of Initial Investment Valuation Methodology of Brazilian Power Transmissions Auction
6
作者 André L. V. Gimenes Raphael B. Heideier +1 位作者 Miguel E. M. Udaeta Marco A. Saidel 《Journal of Power and Energy Engineering》 2017年第1期75-90,共16页
This paper aims to assess the Initial Investment Valuation Methodology of the local regulator, facing the results of auctions, due to the high occurrence of low clearing prices observed from 2003 to 2008 and the high ... This paper aims to assess the Initial Investment Valuation Methodology of the local regulator, facing the results of auctions, due to the high occurrence of low clearing prices observed from 2003 to 2008 and the high percentage of auctions without any bidder recently. The regulator investment forecasted defines the maximum value of Yearly Allowed Revenue and the bidder that offers the lowest YAR value wins the auction. The first type of analysis considers project cost, location, execution deadline, transmission line extension and type of all actions from 1999 to 2015, totalling about 3.361 billion USD. It was not found any correlation of those variables and the result of the actions. The second analysis compared the equipment and the additional costs breakdown of the regulator investment forecast with the real investment in projects from 2009 to 2013 and it rarely surpasses 5%. Suggestions are proposed based on the analysis. 展开更多
关键词 BRAZILIAN AUCTION CLEARING PRICES Transmission Line VALUATION
暂未订购
Reliability Evaluation of Distribution Systems under <i>μ</i>Grid-Tied and Islanded <i>μ</i>Grid Modes Using Monte Carlo Simulation
7
作者 Ahmed R. Abul’Wafa A. T. M. Taha 《Smart Grid and Renewable Energy》 2014年第3期52-62,共11页
Reliability evaluation of distribution networks under grid-tied and islanded μ grid modes is presented. The Monte Carlo simulation (MCS) algorithm is applied to a modified RBTS Bus 2 distribution network. The network... Reliability evaluation of distribution networks under grid-tied and islanded μ grid modes is presented. The Monte Carlo simulation (MCS) algorithm is applied to a modified RBTS Bus 2 distribution network. The network includes three types of distributed energy resources, namely, solar photovoltaic (PV), wind turbine (WT), and diesel turbine generator (DTG). These distributed generators contribute to supply part of the load during grid-connected mode, but supply 100% of the load in the islanded μ grid mode. A storage system is included to decrease the peak load since the peak of the output power of the PV’s and the peak load do not match time wise in most load profiles. The impact of implementing renewable distributed generation, storage systems, and conventional generation on the reliability of distribution network is studied. This study shows that the penetration of distributed generations can improve the reliability indices of the distribution network. 展开更多
关键词 Reliability Evaluation MONTE Carlo Simulation Distributed Generations
在线阅读 下载PDF
Reducing Intermittence of Renewable Energy Sources with Seasonal-Pumped-Storage Plants 被引量:2
8
作者 Pedro P. B. Machado Dorel S. Ramos +1 位作者 Gustavo C. Tenaglia Julian D. Hunt 《Energy and Power Engineering》 2017年第4期273-292,共20页
This paper presents a computational method to model and evaluate if Pumped Storage Plants (PSP) have the potential to reduce the intermittency of wind generation from different sites in Brazil and to improve the opera... This paper presents a computational method to model and evaluate if Pumped Storage Plants (PSP) have the potential to reduce the intermittency of wind generation from different sites in Brazil and to improve the operation efficiency of hydroelectric plants when operating in cascade. Since the problem to be solved does not have a defined analytic solution, a Stochastic Optimization Algorithm was implemented to reach an optimal solution to the set of equations, inputs and proposed scenarios. A case study was developed based on the Paraná River Basin and the results shows that the model can operate in a variety of different operational patterns, making feasible the evaluation of different hydrological and wind scenarios. Given the Model support, it is easy to assume different PSP storage and generation capacities, allowing the comparison between the efficiency improvement of a conventional Pumped-Storage and a Season-al-Pumped-Storage in the same scenario. The study concludes that a PSP can effectively reduce the intermittency of wind and solar sources and contribute to the optimization of the Brazilian electricity sector. 展开更多
关键词 Pumped-Storage HYDROELECTRICITY ELECTRICITY Supply Modelling GENETIC Algorithms EVOLUTIONARY Algorithm
暂未订购
Modification of streamer-to-leader transition model based on radial thermal expansion in the sphere-plane gap discharge at high altitude
9
作者 耿江海 林果 +3 位作者 王平 丁玉剑 丁杨 俞华 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第1期42-49,共8页
Historically,streamer-to-leader transition studies mainly focused on the rod-plane gap and low altitude analysis,with limited attention paid to the sphere-plane gap at high altitude analysis.In this work,sphere-plane ... Historically,streamer-to-leader transition studies mainly focused on the rod-plane gap and low altitude analysis,with limited attention paid to the sphere-plane gap at high altitude analysis.In this work,sphere-plane gap discharge tests were carried out under the gap distance of 5 m at the Qinghai Ultra High Voltage(UHV)test base at an altitude of 2200 m.The experiments measured the physical parameters such as the discharge current,electric field intensity and instantaneous optical power.The duration of the dark period and the critical charge of streamer-toleader transition were obtained at high altitude.Based on radial thermal expansion of the streamer stem,we established a modified streamer-to-leader transition model of the sphere-plane gap discharge at high altitude,and calculated the stem temperature,stem radii and the duration of streamer-to-leader transition.Compared with the measured duration of sphere-plane electrode discharge at an altitude of 2200 m,the error rate of the modified model was 0.94%,while the classical model was 6.97%,demonstrating the effectiveness of the modified model.From the comparisons and analysis,several suggestions are proposed to improve the numerical model for further quantitative investigations of the leader inception. 展开更多
关键词 streamer-to-leader transition model high altitude streamer stem convective diffusion radial thermal expansion
在线阅读 下载PDF
Numerical Study on NOx Emissions of Methane Re-Combustion in a 600 MWe Coal-Fired Boiler
10
作者 Xiaotao Zhang Hussain Ahmad Madni Gondal +4 位作者 Foyuan Duan Weidong Zhang Haoliang Mu Chengyu Zhang Aijun Wang 《Energy and Power Engineering》 2020年第3期101-107,共7页
The fuel staging combustion technology is a promising low NOx combustion technology for coal-fired boiler. In order to reduce NOx emissions, the burners of a 600?MWe coal-fired boiler are retrofitted in which methane ... The fuel staging combustion technology is a promising low NOx combustion technology for coal-fired boiler. In order to reduce NOx emissions, the burners of a 600?MWe coal-fired boiler are retrofitted in which methane gas is selected as a secondary fuel for re-combustion. The CFD models of combustion process are built to investigate?effects of the methane gasratio on combustion process and NOx emissions. A total of 4 cases are numerically studied, including the pure coal combustion case, the coal combustion with 7.5%, 10%, 12.5% of methane gas re-combustion cases respectively. The results show that the re-combustion of methane can reduce the temperature at primary combustion zone, but increase the temperatures at the re-combustion area and the furnace outlet. The NOx concentration at the furnace outlet reduces with the increasing methane gas ratio.?Methane re-combustion can greatly benefit to the NOx emissions reduction. 展开更多
关键词 NUMERICAL Simulation Re-Combustion NOx EMISSION Reduction
在线阅读 下载PDF
Overvoltage Condition Assessment of a Microgrid Due to Faults Occurring in the Islanded Mode of Operation
11
作者 Ricardo Leon Vasquez-Arnez Dorel Soares Ramos Tesoro Elena Del Carpio Huayllas 《Energy and Power Engineering》 2015年第11期525-534,共10页
This paper presents the results of the simulations and their respective analyses corresponding to the power frequency overvoltages resulting from various fault types occurring inside a microgrid. During the islanded m... This paper presents the results of the simulations and their respective analyses corresponding to the power frequency overvoltages resulting from various fault types occurring inside a microgrid. During the islanded mode of operation, the analysed microgrid can be simultaneously fed by a diesel generator, a 1 MW wind power turbine, a small solar system and a 1 MW hydroelectric scheme. The operating voltage of the microgrid is 2.4 kV. During a fault in the system, the overvoltages normally occur in two remarkable instants. The first one occurs at the beginning of the fault itself. The second one occurs at the instant when the fault is cleared. The major concern here is the overvoltage during the fault period. Due to the travelling wave effect along cables and overhead lines composing the microgrid system, these overvoltages can be amplified, thus jeopardizing the insulation level of the microgrid transmission system and related equipment. Much of the work available now is dedicated to overvoltages present in high-voltage systems leaving a gap for the study and behaviour on low voltage microgrid systems. The overvoltage stress is characterized by the maximum low-frequency, short-duration (crest value) of the overvoltage. Both cables and overhead lines that constitute the microgrid transmission system are characterized by their R-L-C parameters. The simulations of the microgrid system are conducted using the ATP program. According to the international ANSI and IEEE standards, the minimum BIL (Basic Impulse Insulation Level) and BSL (Basic Impulse Switching Level) for the 2.4 kV voltage level are 20 kV and 10 kV, respectively;thus, care should be taken so that the healthy phases upon which commonly appear such overvoltages are not exceeded in their insulation level. 展开更多
关键词 Islanded MODE MICROGRIDS OVERVOLTAGE SHORT-CIRCUIT
暂未订购
Research on Modeling and Control of a 100 kW Micro Bio-Gas Turbine
12
作者 Xiaotao Zhang Xiang Liu +2 位作者 Haoliang Mu Wenxian Zhang Aijun Wang 《Journal of Power and Energy Engineering》 2021年第2期1-6,共6页
In order to know about the influences of disturbance on the operating performance, the present work developed the overall dynamic simulation model of the micro gas turbine and investigated the control system under the... In order to know about the influences of disturbance on the operating performance, the present work developed the overall dynamic simulation model of the micro gas turbine and investigated the control system under the disturbances of environmental temperature and unit load. The response processes of main parameters have been obtained. It found that the compressor pressure ratio and the fuel flow rate increase in the case of natural gas being replaced by pine gas. When the system reaches a new steady state, the main parameters change to different values. The output power decreases with the declining of the air mass flow when the ambient temperature rises, the biomass gas mass flow rate increases under the regulation of the control system to maintain the output power and rotating speed in which the thermal efficiency reduces by 1.40%. The thermal efficiency enhances with the increase of output load. The control system can quickly and effectively act to maintain the key parameters at desired value. 展开更多
关键词 Micro Gas Turbine Biomass Gas Overall Model Turbine Control System
在线阅读 下载PDF
Load Shedding Application within a Microgrid to Assure Its Dynamic Performance during Its Transition to the Islanded Mode of Operation
13
作者 Dorel Soares Ramos Tesoro Elena Del Carpio-Huayllas Ricardo Leon Vasquez-Arnez 《Energy and Power Engineering》 2013年第7期437-445,共9页
This article presents the simulation results and analysis related to the response of the generators within a microgrid towards an accidental overload condition that will require some load shedding action. A microgrid ... This article presents the simulation results and analysis related to the response of the generators within a microgrid towards an accidental overload condition that will require some load shedding action. A microgrid overload can occur due to various reasons ranging from poor load schedule, inadequate switching of circuits within the microgrid, outage of one or more generators inside the microgrid, illegal load connections by some low voltage consumers, etc. It was observed that among the main factors that determine the survival of the microgrid during its transition from the grid connected mode to the islanded mode of operation are the size and type of the load connected (passive or dynamic load) as well as the length of time during which the unexpected load is connected. Models of a speed and voltage regulators of a diesel generator, and important for coping with the overload conditions are provided in the paper. The novelty of the work lies in the load shedding simulation and analysis of the specific generators studied herein, regarding that in many countries the microgrid technology is seen as an important alternative towards the ever increasing load demand and also to assist the system during periods of blackout. 展开更多
关键词 Distributed Generation Islanded Operation Mode Load Shedding Microgrid Systems
暂未订购
Research on Active and Reactive Power Decoupling Control Based on VSC-HVDC
14
作者 Hongshan Lin Yiming Lei Feng Ning 《Journal of Electronic Research and Application》 2024年第4期48-54,共7页
Voltage Source Converter-based High Voltage Direct Current(VSC-HVDC)transmission technology represents a groundbreaking approach in high voltage Direct Current(DC)transmission,offering numerous technical advantages an... Voltage Source Converter-based High Voltage Direct Current(VSC-HVDC)transmission technology represents a groundbreaking approach in high voltage Direct Current(DC)transmission,offering numerous technical advantages and broad application prospects.However,in the d-q synchronous rotating coordinate system,the VSC-HVDC exhibits the coupling effect of active power and reactive power,so it needs to be decoupled.This paper introduces the basic principle and mathematical model of the VSC-HVDC transmission system.Through the combination of coordinate transformation and variable substitution,a feedforward decoupling control method is derived.Then the VSC-HVDC simulation model is designed,and the simulation analysis is carried out in the MATLAB environment.The simulation results demonstrate that the method effectively achieves decoupling control of active and reactive power,exhibiting superior dynamic performance and robustness.These findings validate the correctness and effectiveness of the control strategy. 展开更多
关键词 Voltage source converter Decoupling control Feedforward decoupling
在线阅读 下载PDF
The Shift from "Grid-Tie" to Partly "Off-Grid"
15
作者 Balint David Olaszi Jozsef Ladanyi 《Journal of Energy and Power Engineering》 2015年第1期54-58,共5页
This paper deals with that basic economy grounds which support to shift from "grid-tie" to partly "off-grid" PV (photovoltaic) systems. By using our own written VBA (visual basic) Simulation, we can predict th... This paper deals with that basic economy grounds which support to shift from "grid-tie" to partly "off-grid" PV (photovoltaic) systems. By using our own written VBA (visual basic) Simulation, we can predict the size of energy storage capacity and support our basic assumption. 展开更多
关键词 Partly off-grid PV system energy storage simulation.
在线阅读 下载PDF
An Exergy Analysis Model for the Optimal Operation of Integrated Heat-and-Electricity-Based Energy Systems 被引量:8
16
作者 Jianrun Chen Haoyong Chen +4 位作者 Zipeng Liang Xiaodong Zheng Dongliang Xiao Yirui Li Huaguang Yan 《Protection and Control of Modern Power Systems》 SCIE EI 2024年第1期1-18,共18页
Exergy analysis is a unified approach to evaluating the quantity and quality of energy in integrated energy systems(IESs).However,exergy analysis models have been relatively underexplored for IES operation in energy t... Exergy analysis is a unified approach to evaluating the quantity and quality of energy in integrated energy systems(IESs).However,exergy analysis models have been relatively underexplored for IES operation in energy transmission networks.This study addresses this gap by developing an input-benefit exergy model and an exergy loss calculation model for each link within heat-and-electricity-based IESs(HE-IESs),encompassing the transmission networks.Then,an exergy-based unified optimal operation model for HE-IESs is introduced by minimizing the total exergy loss of the system.In addition,the effect of load rate on the energy efficiency of energy conversion equipment is considered.By applying piecewise linearization to the non-convex terms in the objective function and the equality constraints,the proposed optimization model is accurately and efficiently analyzed as a mixed-integer second-order cone pro-gramming problem.The case study results demonstrate that the proposed model reduces equipment-related ex-ergy loss,with approximately 3.2 times the heat net-work-related exergy loss.Moreover,the average deviation gaps of the overall system's exergy loss and equipment's output exergy power between the proposed and the existing models reach 12.94%and 27.83%,respectively.The maximum relative error of the solution results with the proposed linearization method remains below 1.2%,satisfying the requirements of practical application. 展开更多
关键词 UNIFIED LINEARIZATION satisfying
在线阅读 下载PDF
Adaptive coordination control strategy of renewable energy sources,hydrogen production unit,and fuel celi for frequency regulation of a hybrid distributed power system 被引量:7
17
作者 Hossam S.Salama Gaber Magdy +1 位作者 Abualkasim Bakeer Istvan Vokony 《Protection and Control of Modern Power Systems》 2022年第1期472-489,共18页
Owing to the significant number of hybrid generation systems(HGSs)containing various energy sources,coordina-tion between these sources plays a vital role in preserving frequency stability.In this paper,an adaptive co... Owing to the significant number of hybrid generation systems(HGSs)containing various energy sources,coordina-tion between these sources plays a vital role in preserving frequency stability.In this paper,an adaptive coordination control strategy for renewable energy sources(RESs),an aqua electrolyzer(AE)for hydrogen production,and a fuel cell(FC)-based energy storage system(ESS)is proposed to enhance the frequency stability of an HGS.In the proposed system,the excess energy from RESs is used to power electrolysis via an AE for hydrogen energy storage in FCs.The proposed method is based on a proportional-integral(Pl)controller,which is optimally designed using a grey wolf optimization(GWO)algorithm to estimate the surplus energy from RESs(ie,a proportion of total power generation of RESs:Kn).The studied HGS contains various types of generation systems including a diesel generator,wind tur-bines,photovoltaic(PV)systems,AE with FCs,and ESSs(e.g.,battery and flywheel).The proposed method varies Kn with varying frequency deviation values to obtain the best benefits from RESs,while damping the frequency fluc-tuations.The proposed method is validated by considering different loading conditions and comparing with other existing studies that consider Kn as a constant value.The simulation results demonstrate that the proposed method,which changes Kn value and subsequently stores the power extracted from the RESs in hydrogen energy storage according to frequency deviation changes,performs better than those that use constant Kn.The statistical analysis for frequency deviation of HGS with the proposed method has the best values and achieves large improvements for minimum,maximum,difference between maximum and minimum,mean,and standard deviation compared to the existing method. 展开更多
关键词 Adaptive coordination control method Renewable energy sources Fuel cell Grey wolf optimization(GWO)algorithm Fraction factor(Kn) Frequency control
在线阅读 下载PDF
基于统计聚类分析的短期风电功率预测 被引量:46
18
作者 方江晓 周晖 +1 位作者 黄梅 T.S.Sidhu 《电力系统保护与控制》 EI CSCD 北大核心 2011年第11期67-73,78,共8页
考虑到短期风电功率预测模型建立时,样本的选取对预测模型的精度有较大影响,提出了运用聚类方法对历史风速数据进行处理,实现了历史数据的自动分类。根据预测日的平均风速和最大风速等特征参数,按照相似度最大的原则,选择合适的类别作... 考虑到短期风电功率预测模型建立时,样本的选取对预测模型的精度有较大影响,提出了运用聚类方法对历史风速数据进行处理,实现了历史数据的自动分类。根据预测日的平均风速和最大风速等特征参数,按照相似度最大的原则,选择合适的类别作为预测建模用的训练样本。运用时间序列方法,建立风速预测模型,与不经过预处理的相比,所建立预测精度得到了提高,验证了运用聚类进行数据预处理的正确性。运用风力发电机的出力曲线,得到了未来日的风电功率的预测值,为含风电系统的电力系统运行计划的制定,提供了基础数据支持。 展开更多
关键词 风电预测 聚类分析 最大相似度 时间序列模型
在线阅读 下载PDF
Modern Travelling Wave Based Fault Location Techniques for HVDC Transmission Lines 被引量:6
19
作者 陈平 徐丙垠 +1 位作者 李京 葛耀中 《Transactions of Tianjin University》 EI CAS 2008年第2期139-143,共5页
The modern travelling wave based fault location principles for transmission lines are analyzed.In order to apply the travelling wave principles to HVDC transmission lines,the special technical problems are studied.Bas... The modern travelling wave based fault location principles for transmission lines are analyzed.In order to apply the travelling wave principles to HVDC transmission lines,the special technical problems are studied.Based on this,a fault locating system for HVDC transmission lines is developed.The system can support modern double ended and single ended travelling wave princi- ples simultaneously,and it is composed of three different parts:travelling wave data acquisition and processing system,communication network and PC based master station.In the system,the fault generated transients are induced from the ground leads of the over-voltage suppression capacitors of an HVDC line through specially developed travelling wave couplers.The system was applied to 500 kV Gezhouba-Nanqiao(Shanghai)HVDC transmission line in China.Some field operation experiences are summarized,showing that the system has very high reliability and accuracy,and the maximum location error is about 3 km(not more than 0.3%of the total line length). Obviously,the application of the system is successful,and the fault location problem has finally been solved completely since the line operation. 展开更多
关键词 fault location global positioning system HVDC transmission lines REPEATERS
在线阅读 下载PDF
Effect of harmonic distortion on electric energy meters of different metrological principles 被引量:2
20
作者 Illia DIAHOVCHENKO Vitalii VOLOKHIN +2 位作者 Victoria KUROCHKINA Michal SPES Michal KOSTEREC 《Frontiers in Energy》 SCIE CSCD 2019年第2期377-385,共9页
This paper deals with the errors of electric energy metering devices as a result of distortions in the shape of the curves of voltage and current load. It is shown and proved that the errors in energy measurements dep... This paper deals with the errors of electric energy metering devices as a result of distortions in the shape of the curves of voltage and current load. It is shown and proved that the errors in energy measurements depend on the design and the algorithms used in electricity meters. There are three main types of metering devises having different principles: inductive (electro-mechanical), elec-tronic static, and digital electronic (microprocessor). Each of these types has its measuring features. Some devices take into account all the harmonic distortions and the constant component which occur in the network while others measure the power and energy values of the fundamental harmonic only. Such traits lead to the discrepancies in the readings of commercial electric energy meters of different types. Hence, the violations in the measurement system unity occur, and a significant error can be observed in the balance of transmitted/consumed electric energy. 展开更多
关键词 CURRENT DISTORTION ELECTRIC energy METER HARMONICS power quality
原文传递
上一页 1 2 3 下一页 到第
使用帮助 返回顶部