Ordinary columns of jet grouting are circular or fan-shaped. But in recent years, such shapes as candy-shaped columns were put to practical use. They are constructed by switching the rotational speed of the stem in on...Ordinary columns of jet grouting are circular or fan-shaped. But in recent years, such shapes as candy-shaped columns were put to practical use. They are constructed by switching the rotational speed of the stem in one rotation. We applied this method to swing jet grouting. That is, we changed the rotational speeds in the swing jet grouting to make elongated columns near rectangle. The test construction was succeeded and the columns’ shapes conformed to those designed. In addition, the quality was confirmed to be as good as ordinary columns. Radii (distances from center to outer ends) were 1.03 to 1.21 times as large as those designed. Improvement ratios were 95% or more in any position. Strengths were varied by location, but they satisfied design strength 1.5 kN/m2 at any position. We concluded that this new column can be applied to practice in the same way as ordinary columns.展开更多
A pH-sensitive modified polyacrylamide hydrogel was prepared by two steps and the modified polyacrylamide was characterized by ^1HNMR spectrum. The surface morphology and swelling behavior of the hydrogels were invest...A pH-sensitive modified polyacrylamide hydrogel was prepared by two steps and the modified polyacrylamide was characterized by ^1HNMR spectrum. The surface morphology and swelling behavior of the hydrogels were investigated.展开更多
This study explored the seismic response of a house supporting base sides with a polymeric displacement control material and by magnetically levitating the foundation base. In this paper, we explore the possibility an...This study explored the seismic response of a house supporting base sides with a polymeric displacement control material and by magnetically levitating the foundation base. In this paper, we explore the possibility and efficacy of a seismic-isolated detached house as described above from both a shaking table experiment of model and three-dimensional finite element analysis. The seismic-isolated model showed stable response and its acceleration response was significantly reduced compared to the base-fixed model in the shaking table test. Three-dimensional finite element analysis was possible to simulate the experimental results. In the seismic response analysis of a full-scale detached house, the seismic-isolated model showed response reduction and its residual displacement was smaller than that of the sliding-base isolation model.展开更多
文摘Ordinary columns of jet grouting are circular or fan-shaped. But in recent years, such shapes as candy-shaped columns were put to practical use. They are constructed by switching the rotational speed of the stem in one rotation. We applied this method to swing jet grouting. That is, we changed the rotational speeds in the swing jet grouting to make elongated columns near rectangle. The test construction was succeeded and the columns’ shapes conformed to those designed. In addition, the quality was confirmed to be as good as ordinary columns. Radii (distances from center to outer ends) were 1.03 to 1.21 times as large as those designed. Improvement ratios were 95% or more in any position. Strengths were varied by location, but they satisfied design strength 1.5 kN/m2 at any position. We concluded that this new column can be applied to practice in the same way as ordinary columns.
文摘A pH-sensitive modified polyacrylamide hydrogel was prepared by two steps and the modified polyacrylamide was characterized by ^1HNMR spectrum. The surface morphology and swelling behavior of the hydrogels were investigated.
文摘This study explored the seismic response of a house supporting base sides with a polymeric displacement control material and by magnetically levitating the foundation base. In this paper, we explore the possibility and efficacy of a seismic-isolated detached house as described above from both a shaking table experiment of model and three-dimensional finite element analysis. The seismic-isolated model showed stable response and its acceleration response was significantly reduced compared to the base-fixed model in the shaking table test. Three-dimensional finite element analysis was possible to simulate the experimental results. In the seismic response analysis of a full-scale detached house, the seismic-isolated model showed response reduction and its residual displacement was smaller than that of the sliding-base isolation model.