期刊文献+
共找到4,601篇文章
< 1 2 231 >
每页显示 20 50 100
Research on the Quality Management Strategy and Practice of Building Curtain Wall Construction
1
作者 Lichong Duan 《Journal of Architectural Research and Development》 2025年第5期36-42,共7页
Quality management in building curtain wall construction covers both the essence and scope,including material control and process control.It is crucial for safety,longevity,and energy efficiency.Although quality manag... Quality management in building curtain wall construction covers both the essence and scope,including material control and process control.It is crucial for safety,longevity,and energy efficiency.Although quality management models are diverse,they have their limitations.The paper also discusses key points such as quality issues,material and process compatibility,and node construction,along with various techniques and management methods to improve quality.It also highlights areas for further research and future directions. 展开更多
关键词 Building curtain wall Construction quality Quality management
在线阅读 下载PDF
Development of a First Prototype of a Liquid-Shaded Dynamic Glazed Facade for Buildings
2
作者 Marco Cecchi 《Journal of Civil Engineering and Architecture》 2025年第6期296-304,共9页
This paper will report on the development of a prototype of actively controlled facade module,which is capable of adapting its solar transmittance to changeable solar gains.Hence this new facade offers additional feat... This paper will report on the development of a prototype of actively controlled facade module,which is capable of adapting its solar transmittance to changeable solar gains.Hence this new facade offers additional features with respect to the most popular currently used glass facades,which have fixed solar transmittance indeed.The novel technology is made possible by the creation of an additional 1.5-mm-thick sliding shielding liquid,which flows internally,in order to dynamically adapt the window’s solar transmittance.As compared with competitive technologies,this shielding system has low manufacturing costs,is durable,is completely reversible and always transparent,irrespective of its transmittance state.Specifically,the manufacture of a full-size window prototype and the engineering of the window was carried out;moreover,glass pane bending when subject to hydrostatic pressure was eventually assessed.All this information has been used to set up the industrial process needed for its manufacturing. 展开更多
关键词 Active solar control liquid shading window smart buildings
在线阅读 下载PDF
Strength-based concurrent design for structural topology and building orientation of additively manufactured lattice structure
3
作者 Chenyang LI Yamin LI +3 位作者 Shangqin YUAN Shaoying LI Jihong ZHU Weihong ZHANG 《Chinese Journal of Aeronautics》 2025年第9期540-558,共19页
A novel Additive Manufacturing(AM)-driven concurrent design strategy based on the beam characterization model considering strength constraints is proposed.The lattice topology,radius size,Building Orientation(BO),and ... A novel Additive Manufacturing(AM)-driven concurrent design strategy based on the beam characterization model considering strength constraints is proposed.The lattice topology,radius size,Building Orientation(BO),and structural yield strength can be simultaneously adjusted by integrating the overall process-structure-performance relationship of the AM process into the optimization.Specifically,the transverse isotropic material model is adopted to describe the material properties induced by the layer-by-layer manner of additive manufacturing.To bolster lattice strength performance,the stress constraints and ratio constraints of lattice struts are employed.The Tsai-Wu yield criterion is implemented to characterize the lattice strut's strength,while the P-norm method streamlines the handling of multiple constraints,minimizing computational overhead.Moreover,the gradient-based optimization model is established,where both the individual struts diameters and BO can be designed,and the buckling-prone spatial struts are strategically eliminated to improve the lattice strength further.Furthermore,several typical structures are optimized to verify the effectiveness of the proposed method.The optimized results are quite encouraging since the heterogeneous lattice structures with optimized BO obtained by the strength-based concurrent method show a remarkably improved performance compared to traditional designs. 展开更多
关键词 Strength-based design AM-driven design Concurrent design Building orientation Additive manufacturing
原文传递
A New Dynamic and Vertical Photovoltaic Integrated Building Envelope for High-Rise Glaze-Facade Buildings 被引量:1
4
作者 Wuwei Zou Yan Wang +3 位作者 Enze Tian Jiaze Wei Jinqing Peng Jinhan Mo 《Engineering》 SCIE EI CAS CSCD 2024年第8期194-203,共10页
Substantially glazed facades are extensively used in contemporary high-rise buildings to achieve attractive architectural aesthetics.Inherent conflicts exist among architectural aesthetics,building energy consumption,... Substantially glazed facades are extensively used in contemporary high-rise buildings to achieve attractive architectural aesthetics.Inherent conflicts exist among architectural aesthetics,building energy consumption,and solar energy harvesting for glazed facades.In this study,we addressed these conflicts by introducing a new dynamic and vertical photovoltaic integrated building envelope(dvPVBE)that offers extraordinary flexibility with weather-responsive slat angles and blind positions,superior architectural aesthetics,and notable energy-saving potential.Three hierarchical control strategies were proposed for different scenarios of the dvPVBE:power generation priority(PGP),natural daylight priority(NDP),and energy-saving priority(ESP).Moreover,the PGP and ESP strategies were further analyzed in the simulation of a dvPVBE.An office room integrated with a dvPVBE was modeled using EnergyPlus.The influence of the dvPVBE in improving the building energy efficiency and corresponding optimal slat angles was investigated under the PGP and ESP control strategies.The results indicate that the application of dvPVBEs in Beijing can provide up to 131%of the annual energy demand of office rooms and significantly increase the annual net energy output by at least 226%compared with static photovoltaic(PV)blinds.The concept of this novel dvPVBE offers a viable approach by which the thermal load,daylight penetration,and energy generation can be effectively regulated. 展开更多
关键词 Weather-responsive facades Building energy efficiency Dynamic photovoltaic integrated building envelopes(PVBEs) Building-integrated photovoltaics(BIPVs)
在线阅读 下载PDF
The energy flexibility potential of short-term HVAC system management in office buildings under both typical and extreme weather conditions in China during the cooling season 被引量:1
5
作者 HUANG Bingjie LIU Meng LI Ziqiao 《土木与环境工程学报(中英文)》 北大核心 2025年第4期157-171,共15页
To meet the challenge of mismatches between power supply and demand,modern buildings must schedule flexible energy loads in order to improve the efficiency of power grids.Furthermore,it is essential to understand the ... To meet the challenge of mismatches between power supply and demand,modern buildings must schedule flexible energy loads in order to improve the efficiency of power grids.Furthermore,it is essential to understand the effectiveness of flexibility management strategies under different climate conditions and extreme weather events.Using both typical and extreme weather data from cities in five major climate zones of China,this study investigates the energy flexibility potential of an office building under three short-term HVAC management strategies in the context of different climates.The results show that the peak load flexibility and overall energy performance of the three short-term strategies were affected by the surrounding climate conditions.The peak load reduction rate of the pre-cooling and zone temperature reset strategies declined linearly as outdoor temperature increased.Under extreme climate conditions,the daily peak-load time was found to be over two hours earlier than under typical conditions,and the intensive solar radiation found in the extreme conditions can weaken the correlation between peak load reduction and outdoor temperature,risking the ability of a building’s HVAC system to maintain a comfortable indoor environment. 展开更多
关键词 energy flexibility demand-side management extreme weather HVAC systems thermal requirements
在线阅读 下载PDF
Influence of isolated footing embedment on the seismic performance of building considering the soil-foundation-structure interaction:An experimental approach
6
作者 Vaibhav Mittal Manojit Samanta D.P.Kanungo 《Journal of Rock Mechanics and Geotechnical Engineering》 2025年第2期1194-1212,共19页
The present study investigates the influence of embedment depth of isolated footing supporting moment-resisting frame buildings through scaled-down tests.These experiments utilize scaled models representing different ... The present study investigates the influence of embedment depth of isolated footing supporting moment-resisting frame buildings through scaled-down tests.These experiments utilize scaled models representing different building aspect ratios and footing embedment depths.All the model tests are subjected to scaled-down input ground motions of different intensities and magnitudes.These model tests are performed in laminar shear containers through shake table testing.The results obtained for different cases of soil-foundation-structure systems and fixed-base conditions are expressed in terms of natural frequency,peak spectral acceleration,frequency response,lateral deformation,inter-storey drifts,and rocking of the foundation.The analysis reveals that the natural frequency of the coupled system on isolated footings diminishes by 27.52%–58.21%relative to fixed-base conditions,highlighting the significance of accounting for soil-foundation-structure interaction effects.Moreover,a notable increase of 52.97%in the natural frequency of the coupled system is observed as the embedment depth of the footing increases from 0.75 to 6.Additionally,the study demonstrates that the inter-storey drift of the 5-storey building remains well within acceptable limits under dense soil conditions.Consequently,within the parameter range explored in this research,the study concludes that soil-foundation-structure interaction effects are insignificant for low-rise buildings(H≤15 m)supported on isolated footings during seismic events. 展开更多
关键词 Shake table test Isolated footing Soil-foundation-structure interaction Laminar shear box EARTHQUAKE
在线阅读 下载PDF
The Sub-structure Cost Estimation Method:A Technique for Evaluating the Cost of F4-Type Buildings in Developing Countries
7
作者 Alain Symphorien Ndongo Destin Gemetone Etou +1 位作者 Westinevy Benarez Ndzessou Christian Armand Anicet Tathy 《Journal of Environmental Science and Engineering(A)》 2025年第5期245-255,共11页
In an environment where demand for housing is growing and the supply from public authorities is virtually non-existent,several mechanisms for housing production are emerging in the formal,semi-informal and informal co... In an environment where demand for housing is growing and the supply from public authorities is virtually non-existent,several mechanisms for housing production are emerging in the formal,semi-informal and informal construction sectors.The project owner wonders how much it costs to construct a building to an acceptable standard.Cost forecasting in general faces a number of difficulties,including a lack of available information during the preliminary phase of the project.As such,estimation becomes a crucial task involving great responsibility,which can lead to either more convincing results or chaotic situations.This study proposes a quick and effective method for estimating the cost of a single-storey F4 residential building.The modelling is done using multiple linear regression based on a statistical approach applied to twenty(20)projects that have already been completed.The project data are collected from design offices in the city of Brazzaville.The method expresses the cost of an F4 construction by certain project tasks,representing five(5)variables,three(3)of which are related to structural work and two(2)to finishing work,which are easy to determine.This approach,known as MECSO(Cost Estimation Model by Sub-structure),gives good results in all statistical tests carried out with reasonable confidence intervals.This method is very practical for engineering professionals working on the evaluation and control of construction costs. 展开更多
关键词 Model evaluation estimation COST CONSTRUCTION F4
在线阅读 下载PDF
Impact of mechanical ventilation control strategies based on non-steady-state and steady-state Wells-Riley models on airborne transmission and building energy consumption 被引量:2
8
作者 SHA Hao-han ZHANG Xin QI Da-hai 《Journal of Central South University》 SCIE EI CAS CSCD 2022年第7期2415-2430,共16页
Ventilation is an effective solution for improving indoor air quality and reducing airborne transmission.Buildings need sufficient ventilation to maintain a low infection risk but also need to avoid an excessive venti... Ventilation is an effective solution for improving indoor air quality and reducing airborne transmission.Buildings need sufficient ventilation to maintain a low infection risk but also need to avoid an excessive ventilation rate,which may lead to high energy consumption.The Wells-Riley(WR)model is widely used to predict infection risk and control the ventilation rate.However,few studies compared the non-steady-state(NSS)and steady-state(SS)WR models that are used for ventilation control.To fill in this research gap,this study investigates the effects of the mechanical ventilation control strategies based on NSS/SS WR models on the required ventilation rates to prevent airborne transmission and related energy consumption.The modified NSS/SS WR models were proposed by considering many parameters that were ignored before,such as the initial quantum concentration.Based on the NSS/SS WR models,two new ventilation control strategies were proposed.A real building in Canada is used as the case study.The results indicate that under a high initial quantum concentration(e.g.,0.3 q/m^(3))and no protective measures,SS WR control underestimates the required ventilation rate.The ventilation energy consumption of NSS control is up to 2.5 times as high as that of the SS control. 展开更多
关键词 building ventilation Wells-Riley model building energy consumption airborne transmission
在线阅读 下载PDF
Country-level meteorological parameters for building energy efficiency in China 被引量:4
9
作者 LIU Yan WANG Shang-yu +2 位作者 CAO Qi-meng LU Mei YANG Liu 《Journal of Central South University》 SCIE EI CAS CSCD 2022年第7期2301-2316,共16页
Accurate basic data are necessary to support performance-based design for achieving carbon peak and carbon neutral targets in the building sector.Meteorological parameters are the prerequisites of building thermal eng... Accurate basic data are necessary to support performance-based design for achieving carbon peak and carbon neutral targets in the building sector.Meteorological parameters are the prerequisites of building thermal engineering design,heating ventilation and air conditioning design,and energy consumption simulations.Focusing on the key issues such as low spatial coverage and the lack of daily or higher time resolution data,daily and hourly models of the surface meteorological data and solar radiation were established and evaluated.Surface meteorological data and solar radiation data were generated for 1019 cities and towns in China from 1988 to 2017.The data were carefully compared,and the accuracy was proved to be high.All the meteorological parameters can be assessed in the building sector via a sharing platform.Then,country-level meteorological parameters were developed for energy-efficient building assessment in China,based on actual meteorological data in the present study.This set of meteorological parameters may facilitate engineering applications as well as allowing the updating and expansion of relevant building energy efficiency standards.The study was supported by the National Science and Technology Major Project of China during the 13th Five-Year Plan Period,named Fundamental parameters on building energy efficiency in China,comprising of 15 top-ranking universities and institutions in China. 展开更多
关键词 building energy efficiency building thermal engineering heating ventilation and air conditioning meteorological parameters solar radiation
在线阅读 下载PDF
Research on Two Types of Buffer Zone Impact on Surrounding Office Space Environment in Winter in Cold Climate Zone—a Fieldwork in Architectural Design Institute Building of Tsinghua University,Beijing 被引量:1
10
作者 Ye-Hao Song Jun-Jie Li +2 位作者 Ning Zhu Jia-Liang Wang Shi-Meng Hao 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2014年第5期33-39,共7页
Building buffer zone space is not only one of essential approaches for better mental quality of interior building space, but also an important factor that may influence interior thermal comfort and energy consumption.... Building buffer zone space is not only one of essential approaches for better mental quality of interior building space, but also an important factor that may influence interior thermal comfort and energy consumption. This study aims to analyze regulative advantages of buffer zone to the surrounding functional spaces. Based on a fieldwork test in a typical office building in cold climate zone in Beijing,China,the monitor data show interior physical performance in the Winter. The research selects two types of different buffer zones in the same building. One is a south-faced greenhouse which has large dimension with plenty of vegetation,and the other is a simple atrium in the middle of five floor building with mount of skylights. The factors and their influence to surrounding functional spaces and the whole building are found out from the comparisons of collected data by floor to floor monitor test on both buffer zones at the same time. The comparisons of two types of buffer zones conclude that the greenhouse is more effective to air quality regulation but not so clearly wellperformed to thermal buffering as expected due to the dominate active central heating in the Winter. This fieldwork test results for building performance can be helpful for both architects and engineers in the early phase of sustainable design. 展开更多
关键词 public building buffer zone building performance fieldwork test space effect
在线阅读 下载PDF
Building dynamic thermal simulation of low-order multi-dimensional heat transfer 被引量:1
11
作者 高岩 范蕊 +1 位作者 张群力 J.J.ROUX 《Journal of Central South University》 SCIE EI CAS 2014年第1期293-302,共10页
Multi-dimensional heat transfers modeling is crucial for building simulations of insulated buildings,which are widely used and have multi-dimensional heat transfers characteristics.For this work,state-model-reduction ... Multi-dimensional heat transfers modeling is crucial for building simulations of insulated buildings,which are widely used and have multi-dimensional heat transfers characteristics.For this work,state-model-reduction techniques were used to develop a reduced low-order model of multi-dimensional heat transfers.With hot box experiment of hollow block wall,heat flow relative errors between experiment and low-order model predication were less than 8% and the largest errors were less than 3%.Also,frequency responses of five typical walls,each with different thermal masses or insulation modes,the low-order model and the complete model showed that the low-order model results agree very well in the lower excitation frequency band with deviations appearing only at high frequency.Furthermore,low-order model was used on intersection thermal bridge of a floor slab and exterior wall.Results show that errors between the two models are very small.This low-order model could be coupled with most existing simulation software for different thermal mass envelope analyses to make up for differences between the multi-dimensional and one-dimensional models,simultaneously simplifying simulation calculations. 展开更多
关键词 building envelope thermal mass thermal bridge model reduction buildings simulation
在线阅读 下载PDF
Defects in Concrete Elements: A Study of Residential Buildings of 30 Years and above in Onitsha Metropolis, Anambra State, Nigeria 被引量:1
12
作者 Chiamaka Ogochukwu Obiora Fidelis Okechukwu Ezeokoli +1 位作者 Chritopher Chidi Belonwu Francisca Nkachukwu Okeke 《Journal of Building Construction and Planning Research》 2022年第3期102-123,共22页
Building defect is an issue in existing buildings that needs urgent tackling to prevent further problems. This study assessed the defects in concrete elements in residential buildings of 30 years and above in the Onit... Building defect is an issue in existing buildings that needs urgent tackling to prevent further problems. This study assessed the defects in concrete elements in residential buildings of 30 years and above in the Onitsha metropolis of Anambra State, Nigeria. Data collection instruments in the study include structured questionnaire, interviews, visual inspection/observations, archival records, recordings, photographs;and non-destructive testing of the concrete elements in an existing building in the study area. The population of this study constituted of the construction registered professionals and the existing buildings in study area. The sample for the study was based on the calculated sample size using Taro Yamani Formula. A total of 158 registered professionals were sampled from the population of 260. The questionnaires were purposively distributed to the registered professionals up to the required sample sizes of 158 and 129 questionnaires were properly filled and returned. The study used the SPSS and Microsoft Excel to analyze the data. The results were analyzed in percentages and figures using descriptive statistics and presented in the form of pie charts and tables. The finding of the study revealed that the causes and effects of structural defects on the concrete elements in existing buildings in the study area according to the rating are;exposed/corrosion of the embedded metals, faulty workmanship, overload and impacts, chemical attack, freeze-thaw deterioration, fire/heat, restraint to volume change. The visual observation revealed that the structural elements are characterized by heavy defects such as deep vertical, horizontal and diagonal cracks, exposed/ corrosion of the embedded metals, spalling of the concrete slabs. The existence of defects in the concrete members led to the low compressive strength of the concrete elements and the structural instability of the existing buildings as revealed by the non-destructive test. The non-destructive test result revealed that most of the tested concrete elements have low compressive strength value and such were remarked poor as they did not satisfy the assumed value. Essentially, the study concluded by recommending that regular monitoring, inspections and non-destructive testing of concrete elements should be conducted on existing aged and defected buildings to detect the structural stability of the buildings;and it is imperative to evacuate occupants from heavy structurally deteriorated and defected buildings since most of them have lost their residual design life span and ability to sustain imposed loads. 展开更多
关键词 Construction Industry Building Professionals Concrete Elements DEFECTS Residential Buildings Structural Stability Non-Destructive Test Compressive Strength
在线阅读 下载PDF
Assessing the adequacy and sustainability performance of multi-family residential buildings in Anambra State,Nigeria 被引量:1
13
作者 Peter Uchenna Okoye Chukwuemeka Ngwu 《Regional Sustainability》 2021年第1期23-35,共13页
The proliferation of multi-family residential building in Anambra State of Nigeria due to increasing demand without recourse to performance has broughtconcerns about the adequacy and sustainability of this housing typ... The proliferation of multi-family residential building in Anambra State of Nigeria due to increasing demand without recourse to performance has broughtconcerns about the adequacy and sustainability of this housing type.This study therefore,assessed the adequacy and sustainability performance of multi-family residential buildings in urban areas of Anambra State.The study sampled the opinions of 384 households living in multi-family residential buildings through a questionnaire survey.We conducted data analysis based on 214 responses that were useful for analysis.The study found that internal and building component variables and supporting neigh-borhood variables were adequate,but the surrounding environment variables were inadequate based on Mean Score Index.However,based on Sustainability Performance Index,the occupant sperceived social sustainability performance of the buildings as satisfactory,while environmental and economic sustainability performance were perceived as fairly satisfactory.The Pearson correlation coefficient result further established that adequacy of internal and building component variables was significantly and positively related to the residents'perceived social sustainability performance.Adequacy of the surrounding environmental variables was also found to be positively and significantly related to the residents'perceived environmental sustainability performance,whereas adequacy of supporting neighborhood facilities was found to be negatively and significantly related to the residents’perceived economic sustainability performance.This sug-gested that investors and owners of multi-family residential buildings should direct more efforts towards improving the surrounding environment to supplements other facilities and increase the economic benefit of the renters or occupiers with increasing economic sustainability performance in terms of value for money. 展开更多
关键词 Adequacy level Economic sustainability Environmental sustainability Social sustainability Multi-family residential building Residential building
在线阅读 下载PDF
The Impacts of Building Regulations on the Thermal Performance and Energy Consumption of Residential Buildings in Riyadh City-Saudi Arabia 被引量:1
14
作者 Saleh Baharetha Elsayed Amer Mohammad Kotbi 《Open Journal of Energy Efficiency》 2021年第1期1-21,共21页
Riyadh city is the fastest growing city in Saudi Arabia. The rapid urban growth that happened recently in Riyadh was not based on the traditional urban planning principles, which have been established and applied for ... Riyadh city is the fastest growing city in Saudi Arabia. The rapid urban growth that happened recently in Riyadh was not based on the traditional urban planning principles, which have been established and applied for the city development process. The imported building regulations have created a new urban structures and street patterns. The contemporary urban form in Riyadh city is based mainly on traffic and economic consideration with the neglect of environmental dimensions. This research aims to examine the impacts of building regulations on the thermal performance of residential buildings in Riyadh city, with the ultimate goal of establishing planning guidelines that consider the environmental conditions of the city. The methodology adopted for achieving the aim of this study consists of two phases. First, the literature related to building regulations development in Riyadh, as of 2018, was reviewed. Second, buildings energy simulation was conducted to examine the thermal performance of the typical current status of residential building blocks in Riyadh city, and then several changes to building regulations were made to investigate their impacts on the thermal performance of buildings. The results showed that the impacts of Riyadh building regulations on the thermal performance of residential buildings differ across the evaluated cases. The ratio of building height to street width, urban block street orientation, and building orientation are the main factors affecting thermal performance of buildings within urban block. The study also concludes that adjusting the ratio of building height to the distance between buildings could have a significant impact in reducing cooling loads. This study will help policy makers, planners and designers to investigate the shortcoming in the current building regulations. 展开更多
关键词 Building Regulations Energy Consumption Thermal Performance Residential Buildings
在线阅读 下载PDF
What decarbonized the residential building operation worldwide since the 2000s
15
作者 Min-Da Ma Min-Xia Chen +1 位作者 Wei Feng Jing-Wen Huo 《Petroleum Science》 SCIE CAS CSCD 2022年第6期3194-3208,共15页
Decarbonization in operational residential buildings worldwide has become critical in achieving the carbon neutral target due to the growing household energy demand.To accelerate the pace of global carbon neutrality,t... Decarbonization in operational residential buildings worldwide has become critical in achieving the carbon neutral target due to the growing household energy demand.To accelerate the pace of global carbon neutrality,this study explores the operational carbon change in global residential buildings through the generalized Divisia index method and decoupling analysis,considering the decarbonization levels of residential buildings at different scales.The results show that(1)most of the samples showed a decrease in the total emissions from 2000 to 2019.Except for China and the United States(US),the carbon emissions in global residential building operations decreased by 7.95 million tons of carbon dioxide(MtCO_(2))per year over the study period.Emissions per gross domestic product(GDP)was the most positive driver causing the decarbonization of residential buildings,while GDP was the most negative driver.(2)Carbon intensity was essential to achieving a strong decoupling of economic development and carbon emissions.The US almost consistently presented strong decoupling,while China showed weak decoupling over the last two decades.(3)The pace of decarbonization in global residential building operations is gradually slowing down.From 2000 to 2019,decarbonization from residential buildings across 30 countries was 2094.3 MtCO_(2),with a decarbonization efficiency of 3.4%.Overall,this study addresses gaps in evaluating global decarbonization from operational residential buildings and provides a reference for evaluating building decarbonization by other emitters. 展开更多
关键词 Global residential building Operational decarbonization Generalized divisia index method Decoupling elasticity Building decarbonization strategies
原文传递
Developing a Building Environmental Assessment System for Slovakia
16
作者 Silvia Vilcekova Eva Kridlova Burdova 《Journal of Civil Engineering and Architecture》 2010年第10期31-42,共12页
In the previous time the requirements of environmental safety, suitability and responsibility of buildings have increased. The criteria of sustainability are included in building environmental assessment systems and t... In the previous time the requirements of environmental safety, suitability and responsibility of buildings have increased. The criteria of sustainability are included in building environmental assessment systems and tools used in different countries. The aim of building environmental assessment is a sustainable building design, which demands the cooperation among civil engineers, architects, environmentalists and other experts from different areas of building environmental assessment. The existing systems and tools were the basis of the new system development available in Slovak conditions. The purpose of this paper is to introduce the building environmental assessment system (BEAS) which was developed in Slovakia. Significant models used world wide in relation to environmental assessment of buildings, were compared on the basis of their covered. The summary of sustainable building assessment systems will be presented in this paper. Developing a building environmental assessment system for Slovakia is also introduced in the paper. 展开更多
关键词 SUSTAINABILITY BUILDING building performance environmental assessment SYSTEM Slovakia.
在线阅读 下载PDF
Economic Model Predictive Control for Hot Water Based Heating Systems in Smart Buildings
17
作者 M. A. Ahmed Awadelrahman Yi Zong +1 位作者 Hongwei Li Carsten Agert 《Energy and Power Engineering》 2017年第4期112-119,共8页
This paper presents a study to optimize the heating energy costs in a residential building with varying electricity price signals based on an Economic Model Predictive Controller (EMPC). The investigated heating syste... This paper presents a study to optimize the heating energy costs in a residential building with varying electricity price signals based on an Economic Model Predictive Controller (EMPC). The investigated heating system consists of an air source heat pump (ASHP) incorporated with a hot water tank as active Thermal Energy Storage (TES), where two optimization problems are integrated together to optimize both the ASHP electricity consumption and the building heating consumption utilizing a heat dynamic model of the building. The results show that the proposed EMPC can save the energy cost by load shifting compared with some reference cases. 展开更多
关键词 Building ENERGY Management System DEMAND Response ECONOMIC Model PREDICTIVE Control Heat PUMPS Smart Buildings Thermal ENERGY Storage
在线阅读 下载PDF
Performance Assessment of the Overall Building Envelope Thermal Performance-Building Envelope Performance(BEP)Metric
18
作者 Simon Pallin Carl-Eric Hagentoft +2 位作者 Antonio J.Aldykiewicz,Jr. Jason W.DeGraw Mahabir Bhandari 《Journal of Civil Engineering and Architecture》 2021年第6期300-317,共18页
Today,to describe the thermal performance of the building envelope and its components we use a variation of metrics;such as,R-value,ACH(air exchange rate per hour),SHGC(solar heat gain coefficient)of windows,U-factor ... Today,to describe the thermal performance of the building envelope and its components we use a variation of metrics;such as,R-value,ACH(air exchange rate per hour),SHGC(solar heat gain coefficient)of windows,U-factor etc.None of these performance indicators is meant to represent the overall thermal performance.In this paper,such a metric is introduced,the BEP(building envelope performance)value.Unlike the thermal resistance,typically expressed as an R-value,the BEP-value considers additional elements of heat transfer that affect the energy demand of the building because of exterior and interior(solar)thermal loads:conductive and radiant heat transfer,and air infiltration.To demonstrate BEP’s utility,validation studies were carried out by comparing the BEP-value to theoretical results using whole building energy simulation tools such as EnergyPlus and WUFI Plus.Results show that BEP calculations are comparable to calculations made using these simulation tools and that unlike other similar metrics,the BEP-value accounts for all heat transfer mechanisms that are relevant for the overall energy performance of the building envelope.The BEP-value thus allows comparing envelopes of buildings with different use types in a fair and realistic manner. 展开更多
关键词 Building enclosure energy R-VALUE EUI(energy use intensity) AIRTIGHTNESS building envelope campaign.
在线阅读 下载PDF
Application of Key Technologies in Green School Buildings: Taking Sino-German Future City Primary School as an Example
19
作者 Yang Liu Dong Huang +2 位作者 Chunhua Yang Jian Zhou Yunda Tang 《Journal of World Architecture》 2024年第3期36-42,共7页
Green building is a manifestation of the response to the national“dual carbon”strategy.With the large-scale promotion of green buildings,the country has successively issued multiple evaluation standards for green bu... Green building is a manifestation of the response to the national“dual carbon”strategy.With the large-scale promotion of green buildings,the country has successively issued multiple evaluation standards for green buildings.Schools are places for preaching,teaching,and solving doubts,and the campus environment plays an important role in improving students’learning efficiency and promoting their physical and mental health.This article is based on the“Green Building Evaluation Standards”GB/T 50378-2019,analyzing and exploring the integration and application of key technologies in green schools,providing reference for green building designers. 展开更多
关键词 Green buildings Energy conservation and environmental protection Key technologies High-quality buildings
在线阅读 下载PDF
Building Information Modeling for Environmental Impact Assessment in Early Design Phases: A Literature Review
20
作者 Marie-France Stendahl Marie-Claude Dubois +1 位作者 Daniel Forgues Eilif Hjelseth 《Open Journal of Applied Sciences》 2022年第1期59-81,共23页
The building sector is the largest consumer of energy in industrial countries. Saving energy in new buildings or building renovations can thus lead to significant global environmental impacts. In this endeavor, buildi... The building sector is the largest consumer of energy in industrial countries. Saving energy in new buildings or building renovations can thus lead to significant global environmental impacts. In this endeavor, building information <span>modeling (BIM) and building energy modeling (BEM) are two important to</span>ols to make the transition to net-zero energy buildings (NZEB). So far, little attention has been devoted, in the literature, to discuss the connection between BIM, BEM, and Life-cycle assessment (LCA), which is the main topic of this article. A literature review of 157 journal articles and conference proceedings published between 1990 and 2020 is presented. This review outlines knowledge gaps concerning BIM, BEM, and environmental impact assessment. It suggests that defining the process with the right technology (at the right time) would result in a more integrated design process (IDP) and bridge current gaps. The most efficient way to improve process and technology is related to the competences of the architects, engineers and constructors (AEC). The review also indicates that the IDP in the early design phases (EDP) is in need of improvement for architects and engineers, where a better connection between design phases, specific levels of development (LOD) and BIM tools is needed. <span>Competences, process and technology are the three main themes addressed in the review. Their relation to design phases and LOD is discussed. The aim </span>is to propose possible solutions to the current hinders in BIM-to-BEM (BIM2BEM) and BIM-for-LCA (BIM4LCA) integration. 展开更多
关键词 Building Information Modeling (BIM) Building Energy Modeling (BEM) Life Cycle Assessment (LCA) Simulations Energy CARBON Design Process Design Phases Level of Development
在线阅读 下载PDF
上一页 1 2 231 下一页 到第
使用帮助 返回顶部