期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
Numerical simulation of pulsatile non-Newtonian flow in the carotid artery bifurcation 被引量:3
1
作者 Yubo Fan Wentao Jiang +3 位作者 Yuanwen Zou Jinchuan Li Junkai Chen Xiaoyan Deng 《Acta Mechanica Sinica》 SCIE EI CAS CSCD 2009年第2期249-255,共7页
Both clinical and post mortem studies indicate that, in humans, the carotid sinus of the carotid artery bifurcation is one of the favored sites for the genesis and development of atherosclerotic lesions. Hemodynamic f... Both clinical and post mortem studies indicate that, in humans, the carotid sinus of the carotid artery bifurcation is one of the favored sites for the genesis and development of atherosclerotic lesions. Hemodynamic factors have been suggested to be important in atherogenesis. To understand the correlation between atherogenesis and fluid dynamics in the carotid sinus, the blood flow in artery was simulated numerically. In those studies, the property of blood was treated as an incompressible, Newtonian fluid. In fact, however, the blood is a complicated non-Newtonian fluid with shear thinning and viscoelastic properties, especially when the shear rate is low. A variety of non-Newtonian models have been applied in the numerical studies. Among them, the Casson equation was widely used. However, the Casson equation agrees well only when the shear rate is less than 10 s-1. The flow field of the carotid bifurcation usually covers a wide range of shear rate. We therefore believe that it may not be sufficient to describe the property of blood only using the Casson equation in the whole flow field of the carotid bifurcation. In the present study, three different blood constitutive models, namely, the Newtonian, the Casson and the hybrid fluid constitutive models were used in the flow simulation of the human carotid bifurcation. The results were compared among the three models. The results showed that the Newtonian model and the hybrid model had verysimilar distributions of the axial velocity, secondary flow and wall shear stress, but the Casson model resulted in significant differences in these distributions from the other two models. This study suggests that it is not appropriate to only use the Casson equation to simulate the whole flow field of the carotid bifurcation, and on the other hand, Newtonian fluid is a good approximation to blood for flow simulations in the carotid artery bifurcation. 展开更多
关键词 Casson equation Hybrid fluid Newtonianfluid Carotid artery bifurcation
在线阅读 下载PDF
Retraction of lumbar disc herniation achieved by noninvasive techniques: A case report 被引量:4
2
作者 Ping Wang Cai Chen +3 位作者 Qing-Hao Zhang Guo-Dong Sun Cong-An Wang Wei Li 《World Journal of Clinical Cases》 SCIE 2021年第27期8082-8089,共8页
BACKGROUND Lumbar disc herniation(LDH)has emerged as one of the most common causes of low back pain.The routine treatment approach involves chemonucleolysis therapy,discectomy by percutaneous endoscopy,and percutaneou... BACKGROUND Lumbar disc herniation(LDH)has emerged as one of the most common causes of low back pain.The routine treatment approach involves chemonucleolysis therapy,discectomy by percutaneous endoscopy,and percutaneous laser disc decompression.Unfortunately,all of these methods carry inherent risk of causing harm to the patient and,as such,there is an unmet but urgent need for an effective and safe noninvasive treatment for LDH.The purpose of this report is to describe a non-invasive method for re-absorption of LDH.CASE SUMMARY A 34-year-old woman was admitted with a complaint of waist pain that she reported as having become acutely aggravated over the past 3 d and accompanied by discomfort in the right lower limb.Her self-reported medical history included persistent postpartum low back pain from 7 years prior.Physical exam showed positivity for neck flexion test(Lindner sign)and supine abdomen test;the straight leg-raising test showed right 60(+)and left 80(-).Findings from standard imaging(magnetic resonance)and collective physical examinations indicated a L5/S1 herniated lumbar disc.Treatment consisted of three-dimensional(balanced regulating)spinal manipulation and acupuncture,upon which the LDH resolved by retraction.CONCLUSION Following L5/S1 herniated lumbar disc diagnosis,three-dimensional(balanced regulating)spinal manipulation combined with acupuncture therapy is an effective treatment. 展开更多
关键词 Low back pain Lumbar disc herniation RETRACTION Three-dimensional spinal manipulation Balance regulating MANIPULATION Case report
暂未订购
Reabsorption of intervertebral disc prolapse after conservative treatment with traditional Chinese medicine:A case report 被引量:2
3
作者 Cong-An Wang Hong-Fei Zhao +9 位作者 Jing Ju Li Kong Cheng-Jiao Sun Yue-Kun Zheng Feng Zhang Guang-Jian Hou Chen-Chen Guo Sheng-Nan Cao Dan-Dan Wang Bin Shi 《World Journal of Clinical Cases》 SCIE 2023年第10期2308-2314,共7页
BACKGROUND Conservative treatments have been reported to diminish or resolve clinical symptoms of lumbar intervertebral disc herniation(LIDH)within a few weeks.CASE SUMMARY Computed tomography and magnetic resonance i... BACKGROUND Conservative treatments have been reported to diminish or resolve clinical symptoms of lumbar intervertebral disc herniation(LIDH)within a few weeks.CASE SUMMARY Computed tomography and magnetic resonance imaging(MRI)of the lumbar region of a 25-yearold male diagnosed with LIDH showed prolapse of the L5/S2 disc.The disc extended 1.0 cm beyond the vertebral edge and hung along the posterior vertebral edge.The patient elected a conservative treatment regimen that included traditional Chinese medicine(TCM),acupuncture,and massage.During a follow-up period of more than 12 mo,good improvement in pain was reported without complications.MRI of the lumbar region after 12 mo showed obvious reabsorption of the herniation.CONCLUSION A conservative treatment regimen of TCM,acupuncture,and massage promoted reabsorption of a prolapsed disc. 展开更多
关键词 Intervertebral disc degeneration Traditional Chinese medicine REABSORPTION Acupuncture MASSAGE Case report
暂未订购
Prediction of severe preeclampsia in machine learning
4
作者 Xinyuan Zhang Yu Chen +4 位作者 Stephen Salerno Yi Li Libin Zhou Xiaoxi Zeng Huafeng Li 《Medicine in Novel Technology and Devices》 2022年第3期148-153,共6页
This study aimed to find out the blood data characteristics of patients and explore the correlation between severe preeclampsia and blood index value.Provide assistance for the early attention direction of severe pree... This study aimed to find out the blood data characteristics of patients and explore the correlation between severe preeclampsia and blood index value.Provide assistance for the early attention direction of severe preeclampsia diagnosis and treatment.19,653 pregnant women presenting to the West China Second University Hospital,Sichuan University from January 2017 to April 2019.After screening,a total of 248 patients,124 severe preeclampsia cases,and 124 controls were selected for this study.Forty-three blood examination variables were obtained from routine blood work,hepatic,renal and coagulation function examination.Light gradient boosting machine(light GBM),decision tree and random forest were used for date diving.We randomly divided 35%of the original data as a testing set to conduct internal validation of the performance of the prediction model.The area under receiver operating characteristic curve(AUC)was used as the main score to compare the three methods.Finally,a binary classification light GBM model based on aspartate aminotransferase,direct bilirubin and activated partial thromboplastin time ratio can predict severe preeclampsia with sensitivity of 88.37%,specificity of 77.27%,AUC of 89.74%and positive predictive value of 65.96%.We believe relevant quantifiable indicators can establish an effective prediction model,which can provide guidance for early detection and prevention of severe preeclampsia. 展开更多
关键词 PREECLAMPSIA SCREENING PREDICTION Blood examination Data characteristics
在线阅读 下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部