The coupling of capillary electrophoresis to electrospray Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR-MS) was presented for the on-line separation and detection of mixture of peptides. With th...The coupling of capillary electrophoresis to electrospray Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR-MS) was presented for the on-line separation and detection of mixture of peptides. With the ultra-high resolution and unmatchable mass measurement accuracy FT-ICR-MS provides, the separation and identification of angiotensin III, octreotide and elastin chemotactic were successfully achieved using this fabricated device, which showed its great application potential in detection and structural identification for multicomponent sample.展开更多
This paper describes experience with the se- quencing of synthetic segment peptides of gp41 which are used in trimeric peptides as potential peptide-based vaccines and as inhibitors to mimic the fusion state of gp41 i...This paper describes experience with the se- quencing of synthetic segment peptides of gp41 which are used in trimeric peptides as potential peptide-based vaccines and as inhibitors to mimic the fusion state of gp41 in HIV infection using ESI/CID-FT-ICR MS. All b and y″ series ions are found in the CID spectra and the mass difference between the calculated and observed results is very slight. FT-ICR MS again shows its power in peptide sequencing, successfully helping us obtain the sequence of an unknown peptide.展开更多
基金supported by the National Natural Science Foundation of China (20035010 and 20175033) and Instrumental Innovation Project of Chinese Academy of Sciences.
文摘The coupling of capillary electrophoresis to electrospray Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR-MS) was presented for the on-line separation and detection of mixture of peptides. With the ultra-high resolution and unmatchable mass measurement accuracy FT-ICR-MS provides, the separation and identification of angiotensin III, octreotide and elastin chemotactic were successfully achieved using this fabricated device, which showed its great application potential in detection and structural identification for multicomponent sample.
基金supported by the National Natural Science Foundation of China(Grant No.20075002)
文摘This paper describes experience with the se- quencing of synthetic segment peptides of gp41 which are used in trimeric peptides as potential peptide-based vaccines and as inhibitors to mimic the fusion state of gp41 in HIV infection using ESI/CID-FT-ICR MS. All b and y″ series ions are found in the CID spectra and the mass difference between the calculated and observed results is very slight. FT-ICR MS again shows its power in peptide sequencing, successfully helping us obtain the sequence of an unknown peptide.