Performance Assessment of a Real PV System Connected to a Low-Voltage Grid 被引量:1
1
作者 Gaber Magdy Mostafa Metwally +1 位作者 Adel A.Elbaset Esam Zaki 《Energy Engineering》 EI 2024年第1期13-26,共14页
The generation of photovoltaic(PV)solar energy is increasing continuously because it is renewable,unlimited,and clean energy.In the past,generation systems depended on non-renewable sources such as oil,coal,and gas.Th... The generation of photovoltaic(PV)solar energy is increasing continuously because it is renewable,unlimited,and clean energy.In the past,generation systems depended on non-renewable sources such as oil,coal,and gas.Therefore,this paper assesses the performance of a 51 kW PV solar power plant connected to a low-voltage grid to feed an administrative building in the 6th of October City,Egypt.The performance analysis of the considered grid-connected PV system is carried out using power system simulator for Engineering(PSS/E)software.Where the PSS/E program,monitors and uses the power analyzer that displays the parameters and measures some parameters such as current,voltage,total power,power factor,frequency,and current and voltage harmonics,the used inverter from the type of grid inverter for the considered system.The results conclude that when the maximum solar radiation is reached,the maximum current can be obtained from the solar panels,thus obtaining the maximum power and power factor.Decreasing total voltage harmonic distortion,a current harmonic distortion within permissible limits using active harmonic distortion because this type is fast in processing up to 300 microseconds.The connection between solar stations and the national grid makes the system more efficient. 展开更多
关键词 Low-voltage grid photovoltaic(PV)system total harmonic distortion grid-connected PV system
在线阅读 下载PDF
Numerical Investigation of an Idealized Total Cavopulmonary Connection Physiology Assisted by the Axial Blood Pump With and Without Diffuser
2
作者 Zhenxin Zhao Tong Chen +2 位作者 Xudong Liu Shengzhang Wang Haiyan Lu 《Computer Modeling in Engineering & Sciences》 SCIE EI 2020年第12期1173-1184,共12页
In order to improve the surgical treatment of the congenital heart disease patient with single ventricle defect,two axial flow blood pumps,one with diffuser and the other without diffuser,were designed and virtually i... In order to improve the surgical treatment of the congenital heart disease patient with single ventricle defect,two axial flow blood pumps,one with diffuser and the other without diffuser,were designed and virtually implanted into an idealized total cavopulmonary connection(TCPC)model to form two types of Pump-TCPC physiological structure.Computational fluid dynamics(CFD)simulationswere performed to analyze the variations of the hemodynamic characteristics,such as flow field,wall shear stress(WSS),oscillatory shear index(OSI),relative residence time(RRT),between the two Pump-TCPC models.Numerical results indicate that the Pump-TCPC with diffuser has better flow field stability,less damage on endothelial cell of vessel wall,and lower risk of vascular injury and thrombosis formation than that without diffuser. 展开更多