期刊文献+
共找到1,283篇文章
< 1 2 65 >
每页显示 20 50 100
Zero-sequence Circulating Current Reduction for Three-phase Three-level Modular Photovoltaic Grid-connected Systems 被引量:16
1
作者 ZHANG Xing SHAO Zhangping WANG Fusheng LIU Ping REN Kangle 《中国电机工程学报》 EI CSCD 北大核心 2013年第9期I0003-I0003,共1页
针对共享正、负母线和交流母线的三相三电平模块化光伏并网系统的零序环流问题,建立三电平模块化系统零序环流的等效模型,并根据激励源的不同将零序环流分成3类,提出一种共享正、负母线和中线的并联方案来抑制I类零序环流,及一种基于改... 针对共享正、负母线和交流母线的三相三电平模块化光伏并网系统的零序环流问题,建立三电平模块化系统零序环流的等效模型,并根据激励源的不同将零序环流分成3类,提出一种共享正、负母线和中线的并联方案来抑制I类零序环流,及一种基于改进型LCL滤波器的并联方案来抑制II、III类零序环流的高频分量,和采用零序环流控制器来抑制II、III类零序环流的低频分量。最后,通过10 kW的三相三电平模块化光伏并网系统的仿真和实验,证明了零序环流模型分析和抑制方法的正确性。 展开更多
关键词 光伏系统 光伏并网 循环电流 模块化 三相 零序 逆变器并联 闭合回路
原文传递
Integrated paralleling of NPC inverters with suppressed circulating current for high-power renewable energy conversion
2
作者 Weiwei Li Guoxiang Hua +1 位作者 Xing Huang Xueguang Zhang 《Global Energy Interconnection》 2025年第1期134-142,共9页
The development of renewable energy power generation for carbon neutrality and energy transition has been increasing worldwide,leading to an increasing demand for high-power conversion.Compared with traditional interl... The development of renewable energy power generation for carbon neutrality and energy transition has been increasing worldwide,leading to an increasing demand for high-power conversion.Compared with traditional interleaved paralleling,the integrated paralleling of three-level inverters can further reduce the output harmonics.Moreover,a well-designed switching sequence ensures that the average circulating current is zero,which provides a superior and feasible solution to satisfy the demands of high-power operations.However,a large instantaneous loop current exists between shunt converters,which leads to disadvantages such as higher switching device stress and loss.In this study,by utilizing the state-distribution redundancy provided by the integrated modulation process,a new design for switch-ing sequences is suggested for the integrated modulation of shunt three-level converters.This design aims to reduce the circulating current while better preserving the same output current harmonics than traditional parallel methods.The proposal includes an in-depth analysis and explanation of the implementation process.Finally,the proposed method is validated through simulations and prototype experi-ments.The results indicate that compared with traditional methods,the adoption of the improved switching sequence presented in this study leads to an average reduction of 3.2%in the total harmonic distortion of the inverter’s output and an average decrease of 32%in the amplitude of the circulating current.Both the output harmonics and circulating currents are significantly suppressed across various modulation indices. 展开更多
关键词 circulating current Neutral point clamped Parallel operating inverters Space vector modulation
在线阅读 下载PDF
Single-phase-to-ground fault protection based on zero-sequence current ratio coefficient for low-resistance grounding distribution network 被引量:4
3
作者 Jianrui Li Yongli Li +1 位作者 Yonghuan Wang Jinzhao Song 《Global Energy Interconnection》 EI CAS CSCD 2021年第6期564-575,共12页
Definite-time zero-sequence over-current protection is presently used in systems whose neutral point is grounded by a low resistance(low-resistance grounding systems).These systems frequently malfunction owing to thei... Definite-time zero-sequence over-current protection is presently used in systems whose neutral point is grounded by a low resistance(low-resistance grounding systems).These systems frequently malfunction owing to their high settings of the action value when a high-impedance grounding fault occurs.In this study,the relationship between the zero-sequence currents of each feeder and the neutral branch was analyzed.Then,a grounding protection method was proposed on the basis of the zero-sequence current ratio coefficient.It is defined as the ratio of the zero-sequence current of the feeder to that of the neutral branch.Nonetheless,both zero-sequence voltage and zero-sequence current are affected by the transition resistance,The influence of transition resistance can be eliminated by calculating this coefficient.Therefore,a method based on the zero-sequence current ratio coefficient was proposed considering the significant difference between the faulty feeder and healthy feeder.Furthermore,unbalanced current can be prevented by setting the starting current.PSCAD simulation results reveal that the proposed method shows high reliability and sensitivity when a high-resistance grounding fault occurs. 展开更多
关键词 Low-resistance grounding system High-impedance grounding fault Grounding protection zero-sequence current ratio coefficient
在线阅读 下载PDF
Inhibition characteristics of circulating current in parallel inverter driving system of mine hoist 被引量:3
4
作者 Kuanfang He Yong Wang Dongming Xiao 《International Journal of Coal Science & Technology》 EI 2016年第1期68-76,共9页
This research investigated the outputting circulation current inhibition characteristic which are controlled by the instantaneous feedback voltage in inverter parallel driving of the mine hoist. We established a trans... This research investigated the outputting circulation current inhibition characteristic which are controlled by the instantaneous feedback voltage in inverter parallel driving of the mine hoist. We established a transfer function of the parallel inverters controlled by the close-loop adjustment of instantaneous voltage feedback. The influence of the parameters of the close-loop feedback circuit to the inhibition effects to the outputting circulation current is observed. After analyzing the circulating current inhibition characteristics, the proportion integration (PI) controller is introduced into the close-loop adjustment by instantaneous voltage feedback. The characteristics equation is gained to determine the PI parameters by drawing the Bode plots. The inhibition effects of the proposed controller are examined by the established simulation model of parallel inverter system. The harmonic distortion rate at the outputting voltage frequency value of 4, 10, 20, 41 and 50 Hz, are all lower than 2.32 % by the instantaneous outputting voltage feedback. 展开更多
关键词 Mine hoist Parallel inverters circulating current Inhibition characteristic - Close-loop adjustment
在线阅读 下载PDF
Hybrid Predictive Control with Simple Linear Control Based Circulating Current Suppression for Modular Multilevel Converters 被引量:5
5
作者 Yuanxiang Sun Zhen Li Zhenbin Zhang 《CES Transactions on Electrical Machines and Systems》 CSCD 2019年第4期335-341,共7页
The modular multilevel converter(MMC)has become a promising topology for widespread power converter applications.However,an evident circulating current flowing between the phases will increase system losses and compli... The modular multilevel converter(MMC)has become a promising topology for widespread power converter applications.However,an evident circulating current flowing between the phases will increase system losses and complicate the heatsink design.This paper proposes a novel hybrid model predictive control method for MMCs.This method utilizes an indirect structure MPC and a sorting algorithm to implement current tracking and capacitor voltages balancing,considerably resulting in reduced calculation burden.In addition,different from the conventional MPC solutions,we add a simple proportional-integral(PI)controller to suppress circulating current through modifying the submodule(SM)inserted number,which is parallel to the MPC loop.This hybrid control solution combines both advantages of MPC and linear control,evidently resulting in improved performance of circulating current.Finally,the MATLAB/Simulink results of an 11-level MMC system verify the effectiveness of the proposed solution. 展开更多
关键词 circulating current suppression hybrid predictive control linear control modular multilevel converters.
在线阅读 下载PDF
Zero-sequence Current Suppressing Strategy for Dual Three-phase Permanent Magnet Synchronous Machines Connected with Single Neutral Point 被引量:3
6
作者 Zongwang Li Yuxuan Du +2 位作者 Jinghua Ji Tao Tao Wenxiang Zhao 《CES Transactions on Electrical Machines and Systems》 CSCD 2022年第4期465-472,共8页
Dual three-phase permanent-magnet synchronous machines(DTP-PMSM)connected with a single neutral point provide a loop for zero-sequence current(ZSC).This paper proposes a novel space vector pulse width modulation(SVPWM... Dual three-phase permanent-magnet synchronous machines(DTP-PMSM)connected with a single neutral point provide a loop for zero-sequence current(ZSC).This paper proposes a novel space vector pulse width modulation(SVPWM)strategy to suppress the ZSC.Five vectors are selected as basic voltage vectors in one switching period.The fundamental and harmonic planes and the zero-sequence plane are taken into consideration to synthesis the reference voltage vector.To suppress the ZSC,a non-zero zero-sequence voltage(ZSV)is generated to compensate the third harmonic back-EMF.Rather than triangular carrier modulation,the sawtooth carrier modulation strategy is used to generate asymmetric PWM signals.The modulation range is investigated to explore the variation of modulation range caused by considering the zero-sequence plane.With the proposed method,the ZSC can be considerably reduced.The simulated and experimental results are presented to validate the effectiveness of the proposed modulation strategy. 展开更多
关键词 zero-sequence current a single neutral point dual three-phase permanent-magnet synchronous machine third harmonic back-EMF
在线阅读 下载PDF
GENERATOR VIBRATION FAULT DIAGNOSIS METHOD BASED ON ROTOR VIBRATION AND STATOR WINDING PARALLEL BRANCHES CIRCULATING CURRENT CHARACTERISTICS 被引量:2
7
作者 Wan Shuting Li Heming +1 位作者 Li Yonggang Tang Guiji 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2005年第4期592-596,共5页
Rotor vibration characteristics are first analyzed, which are that the rotor vibration of fundamental frequency will increase due to rotor winding inter-turn short circuit fault, air-gap dynamic eccentricity fault, or... Rotor vibration characteristics are first analyzed, which are that the rotor vibration of fundamental frequency will increase due to rotor winding inter-turn short circuit fault, air-gap dynamic eccentricity fault, or imbalance fault, and the vibration of the second frequency will increase when the air-gap static eccentricity fault occurs. Next, the characteristics of the stator winding parallel branches circulating current are analyzed, which are that the second harmonics circulating current will increase when the rotor winding inter-turn short circuit fault occurs, and the fundamental circulating current will increase when the air-gap eccentricity fault occurs, neither being strongly affected by the imbalance fault. Considering the differences of the rotor vibration and circulating current characteristics caused by different rotor faults, a method of generator vibration fault diagnosis, based on rotor vibration and circulating current characteristics, is developed. Finally, the rotor vibration and circulating current of a type SDF-9 generator is measured in the laboratory to verify the theoretical analysis presented above. 展开更多
关键词 Generator Fault diagnosis Rotor vibration characteristic Stator winding parallel branches circulating current
在线阅读 下载PDF
The Circulating Current Analysis and Parameter Design of Interphase-Reactor of HT-7U Toroidal Power Supply
8
作者 许留伟 刘小宁 《Plasma Science and Technology》 SCIE EI CAS CSCD 2003年第2期1703-1708,共6页
This paper analyzes the circulating current which is produced by HT-7Usuperconducting toroidal power supply-two sets of two-reverse-star converter with aninterphase-reactor in parallel running on the basis of the outp... This paper analyzes the circulating current which is produced by HT-7Usuperconducting toroidal power supply-two sets of two-reverse-star converter with aninterphase-reactor in parallel running on the basis of the output voltage mathematical equation ofthree-phase semi-wave converter circuit. A new idea of omitting interphase-reactor between twoconverters is proposed, and the parameter design of interphase-reactor of HT-7 toroidal power supplyis presented. Simulated results demonstrate the validity of this new project. 展开更多
关键词 circulating current interphase-reactor two-reverse-star converter
在线阅读 下载PDF
Improved Ladder Wave Modulation of Circulating Current Suppressing Control Strategy of MMC
9
作者 Pinggang Song Yunfeng Li Lina Wang 《Energy and Power Engineering》 2013年第4期1176-1181,共6页
This paper partitions the arm current of MMC into uncontrollable current and controllable current. The former is determined by the load that can’t be controlled by taking any control strategy. The later caused by the... This paper partitions the arm current of MMC into uncontrollable current and controllable current. The former is determined by the load that can’t be controlled by taking any control strategy. The later caused by the unbalanced total inserted voltage of three arms can be controlled by some improved algorithms. The conclusion based on the researching the essence of circulating current is reached that change the number of the inserted sub-modules in each phase can suppress the circulating current. Combined with the improved ladder wave modulation, a novel circulating current suppression strategy particularly for the inverter station is developed. The improved strategy can adapt to load changes and reduce the circulating current and output voltage THD of MMC ac terminals greatly without increasing any peripheral circuits. Finally, the simulation model of 100 submodules in each phase is constructed in MATLAB and the simulation results verify the correctness and effectiveness of the modified control algorithm. 展开更多
关键词 Modular MULTILEVEL Converter High Voltage Direct current Transmission circulating current Module CHANGING Selection Algorithm Double Frequency NEGATIVE Component
暂未订购
Zero-Sequence Current Suppression Strategy for Open-End Winding Permanent Magnet Synchronous Motor Based on Model Predictive Control
10
作者 LIU Huashan LI Jie YAO Fei 《Journal of Donghua University(English Edition)》 EI CAS 2020年第4期286-292,共7页
Compared with the traditional three-phase star connection winding,the open-end winding permanent magnet synchronous motor(OW-PMSM)system with a common direct current(DC)bus has a zero-sequence circuit,which makes the ... Compared with the traditional three-phase star connection winding,the open-end winding permanent magnet synchronous motor(OW-PMSM)system with a common direct current(DC)bus has a zero-sequence circuit,which makes the common-mode voltage and the back electromotive force(EMF)harmonic generated by the inverters produce the zero-sequence current in the zero-sequence circuit,and the zero-sequence current has great influence on the operation efficiency and stability of the motor control system.A zero-sequence current suppression strategy is presented based on model predictive current control for OW-PMSM.Through the mathematical model of OW-PMSM to establish the predictive model and the zero-sequence circuit model,the common-mode voltage under different voltage vector combinations is fully considered during vector selection and action time calculation.Then zero-sequence loop constraints are established,so as to suppress the zero-sequence current.In the end,the control strategy proposed in this paper is verified by simulation experiments. 展开更多
关键词 open-end winding permanent magnet synchronous motor(OW-PMSM) zero-sequence current HARMONIC model predictive current control common-mode voltage
在线阅读 下载PDF
Circulating current suppression for ground tied variable frequency to constant frequency converter system in aircraft
11
作者 Wei WEI Ming HUANG +2 位作者 Wenli YAO Weilin LI Xiaobin ZHANG 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 2023年第11期386-397,共12页
This paper presents a solution to the circulating current fault of aircraft power supply.The DC-link type Variable Frequency to Constant Frequency(VFCF)converter system is the preferred scheme to feed the constant 400... This paper presents a solution to the circulating current fault of aircraft power supply.The DC-link type Variable Frequency to Constant Frequency(VFCF)converter system is the preferred scheme to feed the constant 400 Hz load in an aircraft with a variable frequency power supply.Due to the requirement of aircraft standards,both grounds of the rectification and inversion stage are tied to the metal frame of the aircraft.With such a tied ground,the DC bus voltage rises greatly,and a large circulating current appears in the casing as the ground,which leads to equipment failure and potential safety hazards.According to the existing methods of circulating current fault suppression,this paper analyzes the causes of the above faults and the harmonic components of circulating current and points out the limitations of the existing methods.Therefore,a Common-Mode(CM)choke-based method is proposed to provide a high impedance in the path of the CM circulating current.By doing so,the circulating current can be suppressed without the additional burden of the hardware and control algorithm,which is quite friendly for quality control of mass-production aircraft.Moreover,a simplified mathematic model of the VFCF converter system is derived to calculate the minimum inductance value reference of the CM choke,which saves the weight of passive devices to the greatest extent.Finally,simulation and experimental results are studied to verify the effectiveness of the proposed method. 展开更多
关键词 Aircraft power supply circulating current Common mode choke Power supply circuits Variable Speed Constant Frequency
原文传递
Adaptive Droop Control for Circulating Current Suppression in Microgrid Based on Fuzzy Logic
12
作者 WANG Ziping SHAN Yinghao 《Journal of Donghua University(English Edition)》 CAS 2024年第6期677-688,共12页
Circulating currents in a microgrid increase the power loss of the microgrid, reduce the operational efficiency, as well as affect the power quality of the microgrid. The existing literature is seldom concerned with m... Circulating currents in a microgrid increase the power loss of the microgrid, reduce the operational efficiency, as well as affect the power quality of the microgrid. The existing literature is seldom concerned with methods to suppress the loop currents using fuzzy logic control. In this paper, a method based on fuzzy control of droop coefficients is proposed to suppress the circulating currents inside the microgrid.The method combines fuzzy control with droop control and can achieve the effect of suppressing the circulating currents by adaptively adjusting the droop coefficients to make the power distribution between each subgrid more balanced. To verify the proposed method, simulation is carried out in Matlab/Simulink environment, and the simulation results show that the proposed method is significantly better than the traditional proportional-integral control method. The circulating currents reduce from about 10 A to several nanoamperes, the bus voltage and frequency drops are significantly improved, and the total harmonic distortion rate of the output voltage reduces from 4.66% to 1.06%. In addition, the method used in this paper can be extended to be applied in multiple inverters connected in parallel, and the simulation results show that the method has a good effect on the suppression of circulating currents among multiple inverters. 展开更多
关键词 circulating current suppression MICROGRID fuzzy logic droop control
在线阅读 下载PDF
Distributed On-line Monitoring System for Sheath Circulating Current of Cross-linked Power Cables
13
作者 MENG Yong-peng PENG Fa-dong +3 位作者 YAN Li CHEN Xiao-lin CHENG Yong-hong LIU Jing 《高电压技术》 EI CAS CSCD 北大核心 2009年第3期533-538,共6页
关键词 供电系统 电缆 信号采集 在线监测系统
原文传递
On the Huanghai (Yellow) Sea circulation:a review by current measurements 被引量:15
14
作者 Heung-Jae Lie(Physical Oceanography Dvision, Korea Ocean Research and Development Institute, P.O. Box 29, Ansan, 425 - 600Seoul, Korea) 《Acta Oceanologica Sinica》 SCIE CAS CSCD 1999年第3期355-373,共19页
The Huanghai (Yellow) Sea circulations suggested in the past were constructed mostly based on hydrographic data or simple numerical models, and were not rigorously compered with direct current measurements. Ourpresent... The Huanghai (Yellow) Sea circulations suggested in the past were constructed mostly based on hydrographic data or simple numerical models, and were not rigorously compered with direct current measurements. Ourpresent understanding of the Huanghai Sea circulation is still very poor and superficial. To evaluate our present knowledge about the circulation and to sketch a more realistic circulation pattern, the previous studies on the circulation arebriefly reviewed and directly measured current data collected in the past are revisited. The Huanghai Sea Warm Current and the northeastward extension in summer of the Changjiang diluted water are paid more attention to, which arethe major currents of the basic circulation, and then attempted to sketch the Huanghai Sea circulation by synthesizinghydrography and current data. The Huanghai Sea circulation is not considered to be persistent since the thin water column, less than 100 m, responds quickly and sensitively to external driving forces. Directly measured current data showthat saline water originating from the Kuroshio water turns clockwise around Cheju-do throughout the year and eventually joins the Tsushima Warm Current at the western channel of the Korea Strait. This clockwise current is called theCheju Warm Current. The current data do not support the persistent existence of the Huanghai Sea Warm Current,which has ho believed to supply heat and salt to the Huanghai Sea throughout the year. However, a northward flowis generated intermittently during the weakening phase of cold air outbreaks in winter. The northeast extension of theChangjiang diluted water in summer is evidenced by satellite-tracked surface drifters. 展开更多
关键词 Huanghai Sea circulATION Cheju Warm current
在线阅读 下载PDF
Numerical Study of the Secondary Circulations in Rip Current Systems 被引量:1
15
作者 LI Rui GUAN Changlong 《Journal of Ocean University of China》 SCIE CAS 2015年第1期9-16,共8页
To investigate the mechanism of secondary circulations in rip current systems, and to explore the relationship between wave conditions and secondary circulation intensity, a series of numerical experiments is performe... To investigate the mechanism of secondary circulations in rip current systems, and to explore the relationship between wave conditions and secondary circulation intensity, a series of numerical experiments is performed using coupled nearshore wave model and circulation model. In these experiments, the rip currents and secondary circulations generated above barred beaches with rip channels are simulated. A comparison experiment is conducted to investigate the formation and hydrodynamics of the secondary circulations. Model results indicate that the secondary circulations consist of alongshore flows driven by wave set-up near the shoreline, part of the feeder currents driven by the wave set-up over the bars, and onshore flows at the end of the rip channel driven by wave breaking and convection. The existence of the secondary circulation barely affects the rip current, but narrows and intensifies the feeder currents. Three groups of experiments of varying incident wave conditions are performed to investigate the relationship between wave conditions and secondary circulation intensity. The velocity of the alongshore flow of the secondary circulation is sensitive to the variation of the incident wave height and water depth. It is also found that the alongshore flow intensity is in direct proportion to the alongshore variation of the wave height gradient between the bars and the shoreline. 展开更多
关键词 secondary circulation rip current WAVES radiation stress
在线阅读 下载PDF
Optimal design of auxiliary-teeth to solve circulation current reduction of permanent magnet linear synchronous motor 被引量:1
16
作者 JANG Ki-bong KIM Jee-hyun +1 位作者 AN Ho-jin KIM Gyu-tak 《Journal of Central South University》 SCIE EI CAS 2011年第3期690-696,共7页
A discontinuity of magnetic circuits according to the end effect is generated in the permanent magnet linear synchronous motor (PMLSM). Due to the unbalanced back electro-motive force (EMF) and impedance produced,... A discontinuity of magnetic circuits according to the end effect is generated in the permanent magnet linear synchronous motor (PMLSM). Due to the unbalanced back electro-motive force (EMF) and impedance produced, unbalanced current is generated. The cireulatin8 current, which is caused by a decrease in the thrust, is generated by the unbalanced current. The optimal design of auxiliary-teeth at the end of the mover was carried out to solve the unbalance of phase by using design of experiment (DOE), and compared with the basic model through finite element analysis (FEA). As a result, the auxiliary-teeth model compensates for the decrease of thrust caused by the unbalanced phase. Also, this model is proven to reduce the detent force by the vibration and noise of the PMLSM and copper loss caused by the circulating current. 展开更多
关键词 permanent magnet linear synchronous motor auxiliary-teeth circulation current end effect thrust reduction
在线阅读 下载PDF
Current Circulation and Water Renewal Time in the Enclosed Marine Area of Pagasitikos Basin, Greece
17
作者 George Bousbouras Panagiotis Angelidis 《Computational Water, Energy, and Environmental Engineering》 2024年第3期113-132,共20页
Greece boasts an impressive closed coastline stretching across 13,676 km, making it the largest in the Mediterranean basin and one of the largest in the world. Given the significant human activities that take place in... Greece boasts an impressive closed coastline stretching across 13,676 km, making it the largest in the Mediterranean basin and one of the largest in the world. Given the significant human activities that take place in coastal areas, understanding the behavior of the sea environment becomes crucial. In this study, we delve into the generation and movement of marine currents as well as the retention time and water age within the waters of Pagasitikos Sea inlet, Greece, through numerical simulation of hydrodynamic characteristics. The main examined points of the understudy region are the area of the port of Volos, the Trikeri channel where the ingress and egress of water from the Gulf takes place and the exchange of seawater through circulation of the Pagasitikos Gulf with the North Evian Gulf. In order to evaluate the results, they were compared with real field measurements and with simulation on a laboratory dummy of the same area. The computational simulation was performed with the ELCOM 2.2 numerical modeling tool and the AEM3D latest version and the main factors simulated are the tide, the consequence that Coriolis force, boundary conditions, the topography and bottom geometry of the bay and the actual meteorological conditions of a whole year. 展开更多
关键词 Fluid Dynamics Simulation current circulation Pagasitikos Basin ELCOM
在线阅读 下载PDF
Current-event Play and Circulation of Information in late Ming China
18
作者 Nie Lina 《学术界》 CSSCI 北大核心 2018年第4期238-246,共9页
This essay examines current-event plays( shishiju 时事剧) and their social functions in late Ming China. Drawing on awide range or primary sources and built on secondary scholarship on information history,the essay of... This essay examines current-event plays( shishiju 时事剧) and their social functions in late Ming China. Drawing on awide range or primary sources and built on secondary scholarship on information history,the essay offered a complete picture of the booming,features,social functions and the decline of the current-event plays. The essay argues that many current-event plays addressed on credibility,timeliness and easy accessibility,which enabled current-event plays to play an important role in information circulation. This essay further exposes the current-event plays not only opened a forum for public discussion but also influenced public opinions greatly from literate elites to the masses in Ming China. Through analyzing current-event plays in the context of Ming society,this essay expands the realm of studying information history. 展开更多
关键词 学习信息 事件 中国 循环 社会功能 散文 奖学金 接近性
在线阅读 下载PDF
一种综合性能优化的两电平并联类交错一体化空间矢量调制策略
19
作者 杜燕 梁晶 +2 位作者 蔡志成 杨向真 苏建徽 《电工技术学报》 北大核心 2026年第2期622-634,共13页
交错并联逆变器可抵消输出纹波,改善并网电流总谐波畸变率(THD),但可能导致共模和零序环流增大。针对此问题,该文提出一种双机并联逆变器的类交错一体化空间矢量调制(SISVM)策略,旨在实现系统的共模电压、零序环流、输出电流纹波以及开... 交错并联逆变器可抵消输出纹波,改善并网电流总谐波畸变率(THD),但可能导致共模和零序环流增大。针对此问题,该文提出一种双机并联逆变器的类交错一体化空间矢量调制(SISVM)策略,旨在实现系统的共模电压、零序环流、输出电流纹波以及开关损耗的综合优化。该文建立两电平并联逆变器的等效三电平模型,并以共模、环流、开关次数为约束条件筛选等效三电平矢量,并通过两电平载波移相实现类三电平调制。对比分析SISVM的输出电流纹波和环流特性,说明了与三电平空间矢量调制(TLSVM)相比,该调制策略可进一步减小零序环流和开关损耗。最后,通过DSP+Starsim实验平台验证了该策略在零序环流和开关损耗方面的有效性。 展开更多
关键词 交错并联逆变器 共模电压 零序环流 输出电流纹波 开关损耗 类交错 一体化调制
在线阅读 下载PDF
基于环流的同步调相机不同位置定子匝间短路故障诊断
20
作者 李俊卿 黄涛 +3 位作者 韩小平 张承志 苑浩 何玉灵 《电力工程技术》 北大核心 2026年第1期125-133,共9页
同步调相机作为特高压直流输电系统中提供无功补偿和电压支撑的重要设备,其运行安全性与可靠性对直流输电工程意义重大。针对轻微定子匝间短路难以诊断以及故障槽难以定位的问题,文中提出一种基于定子支路环流的故障诊断方法。首先,从... 同步调相机作为特高压直流输电系统中提供无功补偿和电压支撑的重要设备,其运行安全性与可靠性对直流输电工程意义重大。针对轻微定子匝间短路难以诊断以及故障槽难以定位的问题,文中提出一种基于定子支路环流的故障诊断方法。首先,从定子支路单个线圈磁动势出发,分析定子匝间短路故障位置对电枢磁动势以及定子支路环流的影响。其次,搭建同步调相机定子匝间短路的场-路耦合模型,对不同位置下定子匝间短路的故障特征进行仿真。最后,总结不同匝间短路故障位置下定子支路环流的变化规律。仿真和实验结果表明,在同步调相机发生相同匝数的定子匝间短路时,短路位置越靠近支路绕组轴线位置,定子支路环流幅值越大;短路位置越远离绕组轴线位置,定子支路环流幅值越小。 展开更多
关键词 同步调相机 定子匝间短路 定子支路环流 故障定位 故障诊断 特高压直流输电系统
在线阅读 下载PDF
上一页 1 2 65 下一页 到第
使用帮助 返回顶部