Facing the economic challenges of significant frequency regulation wear and tear on thermal power units and short energy storage lifespan in thermal-energy storage combined systems participating in grid primary freque...Facing the economic challenges of significant frequency regulation wear and tear on thermal power units and short energy storage lifespan in thermal-energy storage combined systems participating in grid primary frequency regulation(PFR),this paper proposes a novel hybrid energy storage system(HESS)control strategy based on Newton-Raphson optimization algorithm(NRBO)-VMD and a fuzzy neural network(FNN)for PFR.In the primary power allocation stage,the high inertia and slow response of thermal power units prevent them from promptly responding to the high-frequency components of PFR signals,leading to increased mechanical stress.To address the distinct response characteristics of thermal units and HESS,an NRBO-VMD based decomposition method for PFR signals is proposed,enabling a flexible system response to grid frequency deviations.Within the HESS,an adaptive coordinated control strategy and a State of Charge(SOC)self-recovery strategy are introduced.These strategies autonomously adjust the virtual inertia and droop coefficients based on the depth of frequency regulation and the real-time SOC.Furthermore,a FNN is constructed to perform secondary refinement of the internal power distribution within the HESS.Finally,simulations under various operational conditions demonstrate that the proposed strategy effectively mitigates frequent power adjustments of the thermal unit during PFR,adaptively achieves optimal power decomposition and distribution,maintains the flywheel energy storage’s SOC within an optimal range,and ensures the long-term stable operation of the HESS.展开更多
Large-scale new energy grid connection leads to the weakening of the system frequency regulation capability,and the system frequency stability is facing unprecedented challenges.In order to solve rapid frequency fluct...Large-scale new energy grid connection leads to the weakening of the system frequency regulation capability,and the system frequency stability is facing unprecedented challenges.In order to solve rapid frequency fluctuation caused by new energy units,this paper proposes a new energy power system frequency regulation strategy with multiple units including the doubly-fed pumped storage unit(DFPSU).Firstly,based on the model predictive control(MPC)theory,the state space equations are established by considering the operating characteristics of the units and the dynamic behavior of the system;secondly,the proportional-differential control link is introduced to minimize the frequency deviation to further optimize the frequency modulation(FM)output of the DFPSU and inhibit the rapid fluctuation of the frequency;lastly,it is verified on theMatlab/Simulink simulation platform,and the results show that the model predictive control with proportional-differential control link can further release the FM potential of the DFPSU,increase the depth of its FM,effectively reduce the frequency deviation of the system and its rate of change,realize the optimization of the active output of the DFPSU and that of other units,and improve the frequency response capability of the system.展开更多
The frequency regulation reserve setting of wind-PV-storage power stations is crucial.However,the existing grid codes set up the station reserve in a static manner,where the synchronous generator characteristics and f...The frequency regulation reserve setting of wind-PV-storage power stations is crucial.However,the existing grid codes set up the station reserve in a static manner,where the synchronous generator characteristics and frequency-step disturbance scenario are considered.Thus,the advantages of flexible regulation of renewable generations are wasted,resulting in excessive curtailment of wind and solar resources.In this study,a method for optimizing the frequency regulation reserve of wind PV storage power stations was developed.Moreover,a station frequency regulation model was constructed,considering the field dynamic response and the coupling between the station and system frequency dynamics.Furthermore,a method for the online evaluation of the station frequency regulation was proposed based on the benchmark governor fitting.This method helps in overcoming the capacity-based reserve static setting.Finally,an optimization model was developed,along with the proposal of the linearized solving algorithm.The field data from the JH4#station in China’s MX power grid was considered for validation.The proposed method achieves a 24.77%increase in the station income while ensuring the system frequency stability when compared with the grid code-based method.展开更多
As the development of new power systems progresses,the inherent inertia of power systems continues to diminish.Centralized frequency regulation,which relies on rapid communication and real-time control,can enable inve...As the development of new power systems progresses,the inherent inertia of power systems continues to diminish.Centralized frequency regulation,which relies on rapid communication and real-time control,can enable inverter-based thermostatically controlled load(ITCL)clusters to provide virtual inertia support to the power grid.However,ITCL clusters exhibit significant discrete response characteristics,which precludes the direct integration of load-side inertia support into the synchronous unit side.To address this issue,this paper elaborates on the existing technical framework and analyzes the underlying causes of the problem.It proposes a timestamp allocation mechanism for ITCL cluster control instructions,ensuring that many ITCL terminals can be triggered at staggered times,thereby allowing the load cluster power to adhere to the inertia analog control law at any moment.Building on this foundation,the paper further examines the impact of the inertia response delay of ITCL clusters,which is based on centralized frequency regulation,on the stability of the power system.A design scheme for inertia analog control parameters is proposed,taking into account dual constraints,frequency stability and load cluster regulation capacity.Finally,the feasibility and applicability of the proposed mechanism and parameter design scheme are investigated through simulations conducted via MATLAB/Simulink.展开更多
To enhance the frequency stability and lower the regulation mileage payment of a multiarea integrated energy system(IES)that supports the power Internet of Things(IoT),this paper proposes a data-driven cooperative met...To enhance the frequency stability and lower the regulation mileage payment of a multiarea integrated energy system(IES)that supports the power Internet of Things(IoT),this paper proposes a data-driven cooperative method for automatic generation control(AGC).The method consists of adaptive fractional-order proportional-integral(FOPI)controllers and a novel efficient integration exploration multiagent twin delayed deep deterministic policy gradient(EIE-MATD3)algorithm.The FOPI controllers are designed for each area based on the performancebased frequency regulation market mechanism.The EIE-MATD3 algorithm is used to tune the coefficients of the FOPI controllers in real time using centralized training and decentralized execution.The algorithm incorporates imitation learning and efficient integration exploration to obtain a more robust coordinated control strategy.An experiment on the four-area China Southern Grid(CSG)real-time digital system shows that the proposed method can improve the control performance and reduce the regulation mileage payment of each area in the IES.展开更多
In high-renewable-energy power systems,the demand for fast-responding capabilities is growing.To address the limitations of conventional closed-loop frequency control,where the integral coefficient cannot dynamically ...In high-renewable-energy power systems,the demand for fast-responding capabilities is growing.To address the limitations of conventional closed-loop frequency control,where the integral coefficient cannot dynamically adjust the frequency regulation command based on the state of charge(SoC)of energy storage units,this paper proposes a secondary frequency regulation control strategy based on variable integral coefficients for multiple energy storage units.First,a power-uniform controller is designed to ensure that thermal power units gradually take on more regulation power during the frequency regulation process.Next,a control framework based on variable integral coefficients is proposed within the secondary frequency regulation model,along with an objective function that simultaneously considers both Automatic Generation Control(AGC)command tracking performance and SoC recovery requirements of energy storage units.Finally,a gradient descent optimization method is used to dynamically adjust the gain of the energy storage integral controller,allowingmultiple energy storage units to respond in real-time to AGC instructions and SoC variations.Simulation results confirmthe effectiveness of the proposedmethod.Compared to traditional strategies,the proposed approach takes into account the SoCdiscrepancies amongmultiple energy storage units and the duration of system net power imbalances.It successfully implements secondary frequency regulation while achieving dynamic power allocation among the units.展开更多
Energy storage-equipped photovoltaic(PV-storage)systems can meet frequency regulation requirements under various operating conditions,and their coordinated support for grid frequency has become a future trend.To addre...Energy storage-equipped photovoltaic(PV-storage)systems can meet frequency regulation requirements under various operating conditions,and their coordinated support for grid frequency has become a future trend.To address frequency stability issues caused by low inertia and weak damping,this paper proposes a multi-timescale frequency regulation coordinated control strategy for PV-storage integrated systems.First,a self-synchronizing control strategy for grid-connected inverters is designed based on DC voltage dynamics,enabling active inertia support while transmitting frequency variation information.Next,an energy storage inertia support control strategy is developed to enhance the frequency nadir,and an active frequency support control strategy for PV system considering a frequency regulation deadband is proposed,where the deadband value is determined based on the power regulation margin of synchronous generators,allowing the PV-storage system to adaptively switch between inertia support and primary frequency regulation under different disturbance conditions.This approach ensures system frequency stability while fully leveraging the regulation capabilities of heterogeneous resources.Finally,the real-time digital simulation results of the PV-storage integrated system demonstrate that,compared to existing control methods,the proposed strategy effectively reduces the rate of change of frequency and improves the frequency nadir under various disturbance scenarios,verifying its effectiveness.展开更多
This paper presents an output feedback design approach based on the adaptive control scheme developed for nonlinearly parameterized systems,to achieve global output regulation for a class of nonlinear systems in outpu...This paper presents an output feedback design approach based on the adaptive control scheme developed for nonlinearly parameterized systems,to achieve global output regulation for a class of nonlinear systems in output feedback form.We solve the output regulation problem without the knowledge of the sign and the value of the high frequency gain a priori.It is not necessary to have both the limiting assumptions that the exogenous signal co and the unknown parameter ju belong to a prior known compact set and the high frequency gain has a determinate lower and upper bounds.The effectiveness of the proposed algorithm is shown with the help of an example.展开更多
In recent years, global wind power has developed rapidly to alleviate environmental pollution and energy crisis. Due to the potential of enhancing the stability of power system through the application of wind power pa...In recent years, global wind power has developed rapidly to alleviate environmental pollution and energy crisis. Due to the potential of enhancing the stability of power system through the application of wind power participating in power grid frequency regulation, the large-scale integration of wind power has become a hot issue for academic research in recent years. This paper classifies the frequency control problems of wind power integration and summarizes the research of power system frequency regulation strategy with high wind power permeability. Energy storage system participating in frequency regulation of the power system with high wind permeability is reviewed and analyzed.展开更多
A power saving frequency difference controlling method was introduced by the double inverter and motor experiment system.The characters of the system under differ- ent loads were investigated.The theoretical analysis ...A power saving frequency difference controlling method was introduced by the double inverter and motor experiment system.The characters of the system under differ- ent loads were investigated.The theoretical analysis and experiment results show the frequency difference method is a ideal power saving speed regulation method for the dou- ble inverter and motor system.The experiment system is simply structured,convenient to operate and provides a new way of character testing for frequency conversion speed regulation.展开更多
An alternating current(AC)microgrid is a system that integrates renewable power,power converters,controllers and loads.Hierarchical control can manage the frequency of the microgrid to prevent imbalance and collapse o...An alternating current(AC)microgrid is a system that integrates renewable power,power converters,controllers and loads.Hierarchical control can manage the frequency of the microgrid to prevent imbalance and collapse of the system.The existing frequency control methods use traditional proportion integration(PI)controllers,which cannot adjust PI parameters in real-time to respond to the status changes of the system.Hierarchical control driven by fuzzy logic allows real-time adjustment of the PI parameters and the method used a two-layer control structure.The primary control used droop control to adjust power distribution,and fuzzy logic was used in the voltage loop of the primary control.The secondary control was added to make up for frequency deviation caused by droop control,and fuzzy logic was used in the secondary frequency control to deal with the dynamic change of frequency caused by the disturbances of loads.The proposed method was simulated in Matlab/Simulink.In the primary control,the proposed method reduced the total harmonic distortion(THD)of two cycles of the output voltage from 4.19%to 3.89%;in the secondary control,the proposed method reduced the frequency fluctuation of the system by about 0.03 Hz and 0.04 Hz when the load was increased and decreased,respectively.The results show that the proposed methods have a better effect on frequency maintenance and voltage control of the AC microgrid.展开更多
During electric vehicle(EV)-assisted grid frequency modulation,inconsistent state of charge(SOC)among EVs can result in overcharging and discharging of the batteries,affecting the stability of the electrical system.As...During electric vehicle(EV)-assisted grid frequency modulation,inconsistent state of charge(SOC)among EVs can result in overcharging and discharging of the batteries,affecting the stability of the electrical system.As a solution,this paper proposes a priority-based frequency regulation strategy for EVs.Firstly,models for the primary and secondary frequency regulation of EV-assisted power grids are established.Secondly,a consensus algorithm is used to construct a distributed com-munication system for EVs.Target SOC values are used to obtain a local frequency regulation priori-ty list.The list is used in an optimal control plan allowing individual EVs to participate in frequency regulation.Finally,a simulation of this strategy under several scenarios is conducted.The results indicate that the strategy ensures uniform SOC among the participating group of EVs,thereby avoi-ding overcharging and discharging of their batteries.It also reduces frequency fluctuations in the electrical system,making the system more robust compared with the frequency regulation strategy that is not priority-based.展开更多
Main Exhauster is one of the main equipment of sintering production. It needs to consume a lot of electricity. Therefore, the system' s reconstruction for energy-saving will effectively reduce electricity for the pro...Main Exhauster is one of the main equipment of sintering production. It needs to consume a lot of electricity. Therefore, the system' s reconstruction for energy-saving will effectively reduce electricity for the production. The paper takes an iron and steel enterprise that had successfully transformed the synchronous motors of main exhauster of sintering as an example, which describes the application of high-voltage variable frequency speed regulation system in main exhauster of Sintering, so as to provide a reference for other iron and steel enterprises.展开更多
With the increasing penetration of renewable energy,the coordination of energy storage with thermal power for frequency regulation has become an effective means to enhance grid frequency security.Addressing the challe...With the increasing penetration of renewable energy,the coordination of energy storage with thermal power for frequency regulation has become an effective means to enhance grid frequency security.Addressing the challenge of improving the frequency regulation performance of a thermal-storage primary frequency regulation system while reducing its associated losses,this paper proposes a multi-dimensional cooperative optimization strategy for the control parameters of a combined thermal-storage system,considering regulation losses.First,the frequency regulation losses of various components within the thermal power unit are quantified,and a calculation method for energy storage regulation loss is proposed,based on Depth of Discharge(DOD)and C-rate.Second,a thermal-storage cooperative control method based on series compensation is developed to improve the system’s frequency regulation performance.Third,targeting system regulation loss cost and regulation output,and considering constraints on output overshoot and system parameters,an improved Particle Swarm Optimization(PSO)algorithm is employed to tune the parameters of the low-pass filter and the series compensator,thereby reducing regulation losses while enhancing performance.Finally,simulation results demonstrate that the total loss cost of the proposed control strategy is comparable to that of a system with only thermal power participation.However,the thermal power loss cost is reduced by 42.16%compared to the thermal-only case,while simultaneously improving system frequency stability.Thus,the proposed strategy effectively balances system frequency stability and economic efficiency.展开更多
This paper presents a method of tuning governor control parameters of an isolated hydropower generator considering the primary frequency performance and small-signal stability. First, generators that can be operated i...This paper presents a method of tuning governor control parameters of an isolated hydropower generator considering the primary frequency performance and small-signal stability. First, generators that can be operated in isolated state are identified. Second, different schemes are proposed for generator mode switching from on-grid to off-grid state through comparison and mechanism analysis. Third, the time domain model and frequency domain model of the isolated generator governor are constructed to respectively estimate the primary frequency performance and small signal stability. Parameter sets that satisfy the primary frequency performance and small signal stability are acquired as optimal values of governor control parameters. Finally, the measurement-based parameters of the governor are identified and validated using simulations to demonstrate the feasibility and effectiveness of the method.展开更多
The application of virtual synchronous generator(VSG)control in flywheel energy storage systems(FESS)is an effective solution for addressing the challenges related to reduced inertia and inadequate power supply in mic...The application of virtual synchronous generator(VSG)control in flywheel energy storage systems(FESS)is an effective solution for addressing the challenges related to reduced inertia and inadequate power supply in microgrids.Considering the significant variations among individual units within a flywheel array and the poor frequency regulation performance under conventional control approaches,this paper proposes an adaptive VSG control strategy for a flywheel energy storage array(FESA).First,by leveraging the FESA model,a variable acceleration factor is integrated into the speed-balance control strategy to effectively achieve better state of charge(SOC)equalization across units.Furthermore,energy control with a dead zone is introduced to prevent SOC of the FESA from exceeding the limit.The dead zone parameter is designed based on the SOC warning intervals of the flywheel array to mitigate its impact on regular operation.In addition,VSG technology is applied for the grid-connected control of the FESA,and the damping characteristic of the VSG is decoupled from the primary frequency regulation through power differential feedback.This ensures optimal dynamic performance while reducing the need for frequent involvement in frequency regulation.Subsequently,a parameter design method is developed through a small-signal stability analysis.Consequently,considering the SOC of the FESA,an adaptive control strategy for the inertia damping and the P/ωdroop coefficient of the VSG control is proposed to optimize the grid support services of the FESA.Finally,the effectiveness of the proposed control methods is demonstrated through electromagnetic transient simulations using MATLAB/Simulink.展开更多
In this paper, an attempt has been made to produce a recipient system of wireless charge for a simple hearing aid so that electrical signal would be generated through detecting and receiving radio frequency waves (RF)...In this paper, an attempt has been made to produce a recipient system of wireless charge for a simple hearing aid so that electrical signal would be generated through detecting and receiving radio frequency waves (RF). The purpose of this design is to receive wireless charge for hearing aids and basically for any electronic device which is not required to a high energy for being setup. In this study, it has been demonstrated that as the amount of radio receiving energy increases, distance of receiver from antenna should be decreased;otherwise, either maximum amount of the receiving energy, or signal power density of the transmitter should be increased. Since it is impossible to be performed, it is decided to set up an energy receiving system constructed by rectenna and charge Circuit and to adjust their parameters to provide energy requirements for a device with low-power consumption. In this paper, different components of an energy receiving system from radio frequency band have been mentioned and a diagram block has been suggested. Subsequently, input impedance of designed antenna has been adjusted by provided relations. This impedance should be adjusted with the total impedance of regarded hearing aid Circuit by which the highest amount of received signal power is transferred to the battery of hearing aids. Received signal is converted to a dc voltage by rectifier diode. Finally, by applying a voltage regulator which has been designed using a common-collector amplifier not only the output voltage is kept constant, but the power is also strengthened. The battery of the hearing aids will be charged using the obtained power and voltage.展开更多
A continuous-time Model Predictive Controller was proposed using Kautz function in order to improve the performance of Load Frequency Control(LFC).A dynamic model of an interconnected power system was used for Model P...A continuous-time Model Predictive Controller was proposed using Kautz function in order to improve the performance of Load Frequency Control(LFC).A dynamic model of an interconnected power system was used for Model Predictive Controller(MPC)design.MPC predicts the future trajectory of the dynamic model by calculating the optimal closed loop feedback gain matrix.In this paper,the optimal closed loop feedback gain matrix was calculated using Kautz function.Being an Orthonormal Basis Function(OBF),Kautz function has an advantage of solving complex pole-based nonlinear system.Genetic Algorithm(GA)was applied to optimally tune the Kautz function-based MPC.A constraint based on phase plane analysis was implemented with the cost function in order to improve the robustness of the Kautz function-based MPC.The proposed method was simulated with three area interconnected power system and the efficiency of the proposed method was measured and exhibited by comparing with conventional Proportional and Integral(PI)controller and Linear Quadratic Regulation(LQR).展开更多
In view of the difficulty of automatic adjustment, the recovery lag and the major accident potential of the mine ventilation system, an experimental model of the pipe net was established according to the typical one m...In view of the difficulty of automatic adjustment, the recovery lag and the major accident potential of the mine ventilation system, an experimental model of the pipe net was established according to the typical one mine and one working face ventilation system of Daliuta coal mine. Using the best uniform approximation method of Chebyshev interpolation to fit the fan performance curve, we experimentally determined fan characteristics with different frequencies and establish the data base for the curves. Based on ventilation network monitoring theory, we designed a monitoring system for ventilation network parameter monitoring and fan operating frequency automatic control. Using the absolute methane emission quantity to predict the air quantity requirement of branch and fan frequency, we established a f-ω regulation model based on fan frequency and absolute methane emission quantity. After analysing methane emission and distribution characteristics, using CO_2 to simulate the methane emission characteristics from a working face, we verified the correctness and rationality of the f-ω regulation model. The fan operation frequency is adjusted by the method of air adjustment change with methane emission quantity and the curve searching method after determining air quantity requirements. The results show that the air quantity in a branch strictly changes according to the f-ω regulation model, in the airincreasing dilution by fan frequency regulation, the CO_2 concentration is limited to the set threshold value. The paper verifies the practicability of a frequency regulation system and the feasibility of the frequency adjustment scheme and provides guidance for the construction of automatic frequency conversion control system in coal mine ventilation networks.展开更多
The increasing integration of renewable energy sources poses great challenges to the power system frequency se curity.However,the existing electricity market mechanism lacks integration and incentives for emerging fre...The increasing integration of renewable energy sources poses great challenges to the power system frequency se curity.However,the existing electricity market mechanism lacks integration and incentives for emerging frequency regula tion(FR)resources such as wind power generators(WPGs),which may reduce their motivation to provide frequency sup port and further deteriorate the frequency dynamics.In this pa per,a market scheduling and pricing method for comprehen sive frequency regulation services(FRSs)is proposed.First,a modeling approach for flexible FR capabilities of WPGs is pro posed based on the mechanism of inertia control and power re serve control.Subsequently,considering the differences in in verter control strategies,a novel system frequency response model with grid-following and grid-forming inverters is estab lished.Combined with the automatic generation control,the fre quency security constraints of the whole FR process are de rived,and integrated into the market scheduling model to cooptimize the energy and FRSs.Finally,by distinguishing the contributions of various types of resources in different FR stag es,a differentiated pricing scheme is proposed to incentivize producers with various regulation qualities to provide FRSs.The effectiveness of the proposed method is verified on the mod ified IEEE 6-bus system and the IEEE RTS-79 system.展开更多
基金supported by the Lanzhou Science and Technology Plan Project(XM1753694781389).
文摘Facing the economic challenges of significant frequency regulation wear and tear on thermal power units and short energy storage lifespan in thermal-energy storage combined systems participating in grid primary frequency regulation(PFR),this paper proposes a novel hybrid energy storage system(HESS)control strategy based on Newton-Raphson optimization algorithm(NRBO)-VMD and a fuzzy neural network(FNN)for PFR.In the primary power allocation stage,the high inertia and slow response of thermal power units prevent them from promptly responding to the high-frequency components of PFR signals,leading to increased mechanical stress.To address the distinct response characteristics of thermal units and HESS,an NRBO-VMD based decomposition method for PFR signals is proposed,enabling a flexible system response to grid frequency deviations.Within the HESS,an adaptive coordinated control strategy and a State of Charge(SOC)self-recovery strategy are introduced.These strategies autonomously adjust the virtual inertia and droop coefficients based on the depth of frequency regulation and the real-time SOC.Furthermore,a FNN is constructed to perform secondary refinement of the internal power distribution within the HESS.Finally,simulations under various operational conditions demonstrate that the proposed strategy effectively mitigates frequent power adjustments of the thermal unit during PFR,adaptively achieves optimal power decomposition and distribution,maintains the flywheel energy storage’s SOC within an optimal range,and ensures the long-term stable operation of the HESS.
基金supported by the National Natural Science Foundation of China(Project No.52377082)the Scientific Research Program of Jilin Provincial Department of Education(Project No.JJKH20230123KJ).
文摘Large-scale new energy grid connection leads to the weakening of the system frequency regulation capability,and the system frequency stability is facing unprecedented challenges.In order to solve rapid frequency fluctuation caused by new energy units,this paper proposes a new energy power system frequency regulation strategy with multiple units including the doubly-fed pumped storage unit(DFPSU).Firstly,based on the model predictive control(MPC)theory,the state space equations are established by considering the operating characteristics of the units and the dynamic behavior of the system;secondly,the proportional-differential control link is introduced to minimize the frequency deviation to further optimize the frequency modulation(FM)output of the DFPSU and inhibit the rapid fluctuation of the frequency;lastly,it is verified on theMatlab/Simulink simulation platform,and the results show that the model predictive control with proportional-differential control link can further release the FM potential of the DFPSU,increase the depth of its FM,effectively reduce the frequency deviation of the system and its rate of change,realize the optimization of the active output of the DFPSU and that of other units,and improve the frequency response capability of the system.
基金supported by the Scientific Research Project of China Three Gorges Group Co.LTD(Contract Number:202103368).
文摘The frequency regulation reserve setting of wind-PV-storage power stations is crucial.However,the existing grid codes set up the station reserve in a static manner,where the synchronous generator characteristics and frequency-step disturbance scenario are considered.Thus,the advantages of flexible regulation of renewable generations are wasted,resulting in excessive curtailment of wind and solar resources.In this study,a method for optimizing the frequency regulation reserve of wind PV storage power stations was developed.Moreover,a station frequency regulation model was constructed,considering the field dynamic response and the coupling between the station and system frequency dynamics.Furthermore,a method for the online evaluation of the station frequency regulation was proposed based on the benchmark governor fitting.This method helps in overcoming the capacity-based reserve static setting.Finally,an optimization model was developed,along with the proposal of the linearized solving algorithm.The field data from the JH4#station in China’s MX power grid was considered for validation.The proposed method achieves a 24.77%increase in the station income while ensuring the system frequency stability when compared with the grid code-based method.
基金supported by the Key Scientific and Technological Projects(2024KJGG27)of Tianfu Yongxing Laboratorythe Experimental Platform Open Innovation Funding(209042025003)of Sichuan Energy Internet Research Institute,Tsinghua University.
文摘As the development of new power systems progresses,the inherent inertia of power systems continues to diminish.Centralized frequency regulation,which relies on rapid communication and real-time control,can enable inverter-based thermostatically controlled load(ITCL)clusters to provide virtual inertia support to the power grid.However,ITCL clusters exhibit significant discrete response characteristics,which precludes the direct integration of load-side inertia support into the synchronous unit side.To address this issue,this paper elaborates on the existing technical framework and analyzes the underlying causes of the problem.It proposes a timestamp allocation mechanism for ITCL cluster control instructions,ensuring that many ITCL terminals can be triggered at staggered times,thereby allowing the load cluster power to adhere to the inertia analog control law at any moment.Building on this foundation,the paper further examines the impact of the inertia response delay of ITCL clusters,which is based on centralized frequency regulation,on the stability of the power system.A design scheme for inertia analog control parameters is proposed,taking into account dual constraints,frequency stability and load cluster regulation capacity.Finally,the feasibility and applicability of the proposed mechanism and parameter design scheme are investigated through simulations conducted via MATLAB/Simulink.
基金upported by National Natural Science Foundation of China(52307118).
文摘To enhance the frequency stability and lower the regulation mileage payment of a multiarea integrated energy system(IES)that supports the power Internet of Things(IoT),this paper proposes a data-driven cooperative method for automatic generation control(AGC).The method consists of adaptive fractional-order proportional-integral(FOPI)controllers and a novel efficient integration exploration multiagent twin delayed deep deterministic policy gradient(EIE-MATD3)algorithm.The FOPI controllers are designed for each area based on the performancebased frequency regulation market mechanism.The EIE-MATD3 algorithm is used to tune the coefficients of the FOPI controllers in real time using centralized training and decentralized execution.The algorithm incorporates imitation learning and efficient integration exploration to obtain a more robust coordinated control strategy.An experiment on the four-area China Southern Grid(CSG)real-time digital system shows that the proposed method can improve the control performance and reduce the regulation mileage payment of each area in the IES.
文摘In high-renewable-energy power systems,the demand for fast-responding capabilities is growing.To address the limitations of conventional closed-loop frequency control,where the integral coefficient cannot dynamically adjust the frequency regulation command based on the state of charge(SoC)of energy storage units,this paper proposes a secondary frequency regulation control strategy based on variable integral coefficients for multiple energy storage units.First,a power-uniform controller is designed to ensure that thermal power units gradually take on more regulation power during the frequency regulation process.Next,a control framework based on variable integral coefficients is proposed within the secondary frequency regulation model,along with an objective function that simultaneously considers both Automatic Generation Control(AGC)command tracking performance and SoC recovery requirements of energy storage units.Finally,a gradient descent optimization method is used to dynamically adjust the gain of the energy storage integral controller,allowingmultiple energy storage units to respond in real-time to AGC instructions and SoC variations.Simulation results confirmthe effectiveness of the proposedmethod.Compared to traditional strategies,the proposed approach takes into account the SoCdiscrepancies amongmultiple energy storage units and the duration of system net power imbalances.It successfully implements secondary frequency regulation while achieving dynamic power allocation among the units.
基金supported by the State Grid Corporation of China under Grant for Science and Technology Projects(No.SGNXJYOOZWJS2500029).
文摘Energy storage-equipped photovoltaic(PV-storage)systems can meet frequency regulation requirements under various operating conditions,and their coordinated support for grid frequency has become a future trend.To address frequency stability issues caused by low inertia and weak damping,this paper proposes a multi-timescale frequency regulation coordinated control strategy for PV-storage integrated systems.First,a self-synchronizing control strategy for grid-connected inverters is designed based on DC voltage dynamics,enabling active inertia support while transmitting frequency variation information.Next,an energy storage inertia support control strategy is developed to enhance the frequency nadir,and an active frequency support control strategy for PV system considering a frequency regulation deadband is proposed,where the deadband value is determined based on the power regulation margin of synchronous generators,allowing the PV-storage system to adaptively switch between inertia support and primary frequency regulation under different disturbance conditions.This approach ensures system frequency stability while fully leveraging the regulation capabilities of heterogeneous resources.Finally,the real-time digital simulation results of the PV-storage integrated system demonstrate that,compared to existing control methods,the proposed strategy effectively reduces the rate of change of frequency and improves the frequency nadir under various disturbance scenarios,verifying its effectiveness.
基金supported by the National Natural Science Foundation of China(61663030,61663032)the Natural Science Foundation of Jiangxi Province(20142BAB207021)+4 种基金the Foundation of Jiangxi Educational Committee(GJJ150753)the Open Fund of Key Laboratory of Image Processing and Pattern Recognition of Jiangxi Province(Nanchang Hangkong University)(TX201404003)the Key Laboratory of Nondestructive Testing(Nanchang Hangkong University)Ministry of Education(ZD29529005)the Reform Project of Degree and Postgraduate Education in Jiangxi(JXYJG-2017-131)
文摘This paper presents an output feedback design approach based on the adaptive control scheme developed for nonlinearly parameterized systems,to achieve global output regulation for a class of nonlinear systems in output feedback form.We solve the output regulation problem without the knowledge of the sign and the value of the high frequency gain a priori.It is not necessary to have both the limiting assumptions that the exogenous signal co and the unknown parameter ju belong to a prior known compact set and the high frequency gain has a determinate lower and upper bounds.The effectiveness of the proposed algorithm is shown with the help of an example.
文摘In recent years, global wind power has developed rapidly to alleviate environmental pollution and energy crisis. Due to the potential of enhancing the stability of power system through the application of wind power participating in power grid frequency regulation, the large-scale integration of wind power has become a hot issue for academic research in recent years. This paper classifies the frequency control problems of wind power integration and summarizes the research of power system frequency regulation strategy with high wind power permeability. Energy storage system participating in frequency regulation of the power system with high wind permeability is reviewed and analyzed.
文摘A power saving frequency difference controlling method was introduced by the double inverter and motor experiment system.The characters of the system under differ- ent loads were investigated.The theoretical analysis and experiment results show the frequency difference method is a ideal power saving speed regulation method for the dou- ble inverter and motor system.The experiment system is simply structured,convenient to operate and provides a new way of character testing for frequency conversion speed regulation.
基金National Natural Science Foundation of China(No.62303107)Fundamental Research Funds for the Central Universities,China(Nos.2232022G-09 and 2232021D-38)Shanghai Sailing Program,China(No.21YF1400100)。
文摘An alternating current(AC)microgrid is a system that integrates renewable power,power converters,controllers and loads.Hierarchical control can manage the frequency of the microgrid to prevent imbalance and collapse of the system.The existing frequency control methods use traditional proportion integration(PI)controllers,which cannot adjust PI parameters in real-time to respond to the status changes of the system.Hierarchical control driven by fuzzy logic allows real-time adjustment of the PI parameters and the method used a two-layer control structure.The primary control used droop control to adjust power distribution,and fuzzy logic was used in the voltage loop of the primary control.The secondary control was added to make up for frequency deviation caused by droop control,and fuzzy logic was used in the secondary frequency control to deal with the dynamic change of frequency caused by the disturbances of loads.The proposed method was simulated in Matlab/Simulink.In the primary control,the proposed method reduced the total harmonic distortion(THD)of two cycles of the output voltage from 4.19%to 3.89%;in the secondary control,the proposed method reduced the frequency fluctuation of the system by about 0.03 Hz and 0.04 Hz when the load was increased and decreased,respectively.The results show that the proposed methods have a better effect on frequency maintenance and voltage control of the AC microgrid.
基金Supported by the China Postdoctoral Science Foundation(No.2022M710039).
文摘During electric vehicle(EV)-assisted grid frequency modulation,inconsistent state of charge(SOC)among EVs can result in overcharging and discharging of the batteries,affecting the stability of the electrical system.As a solution,this paper proposes a priority-based frequency regulation strategy for EVs.Firstly,models for the primary and secondary frequency regulation of EV-assisted power grids are established.Secondly,a consensus algorithm is used to construct a distributed com-munication system for EVs.Target SOC values are used to obtain a local frequency regulation priori-ty list.The list is used in an optimal control plan allowing individual EVs to participate in frequency regulation.Finally,a simulation of this strategy under several scenarios is conducted.The results indicate that the strategy ensures uniform SOC among the participating group of EVs,thereby avoi-ding overcharging and discharging of their batteries.It also reduces frequency fluctuations in the electrical system,making the system more robust compared with the frequency regulation strategy that is not priority-based.
文摘Main Exhauster is one of the main equipment of sintering production. It needs to consume a lot of electricity. Therefore, the system' s reconstruction for energy-saving will effectively reduce electricity for the production. The paper takes an iron and steel enterprise that had successfully transformed the synchronous motors of main exhauster of sintering as an example, which describes the application of high-voltage variable frequency speed regulation system in main exhauster of Sintering, so as to provide a reference for other iron and steel enterprises.
基金supported by the Science and Technology Development Project of Jilin Province(Project No.YDZJ202301ZYTS284).
文摘With the increasing penetration of renewable energy,the coordination of energy storage with thermal power for frequency regulation has become an effective means to enhance grid frequency security.Addressing the challenge of improving the frequency regulation performance of a thermal-storage primary frequency regulation system while reducing its associated losses,this paper proposes a multi-dimensional cooperative optimization strategy for the control parameters of a combined thermal-storage system,considering regulation losses.First,the frequency regulation losses of various components within the thermal power unit are quantified,and a calculation method for energy storage regulation loss is proposed,based on Depth of Discharge(DOD)and C-rate.Second,a thermal-storage cooperative control method based on series compensation is developed to improve the system’s frequency regulation performance.Third,targeting system regulation loss cost and regulation output,and considering constraints on output overshoot and system parameters,an improved Particle Swarm Optimization(PSO)algorithm is employed to tune the parameters of the low-pass filter and the series compensator,thereby reducing regulation losses while enhancing performance.Finally,simulation results demonstrate that the total loss cost of the proposed control strategy is comparable to that of a system with only thermal power participation.However,the thermal power loss cost is reduced by 42.16%compared to the thermal-only case,while simultaneously improving system frequency stability.Thus,the proposed strategy effectively balances system frequency stability and economic efficiency.
基金supported by the Fujian Provincial Government Project (Title: Research on whole process evaluation of dynamic stability and control strategy in condition of grid connection of ultra-high voltage and large scale penetration of nuclear power.No.2015H0023)the State Grid Science & Technology Project (Title: Research on the improvement on stability of primary frequency of generator in account of the tolerance of equipment.No.52130417002P)the Key project of State Grid Fujian Electric Power Company,Ltd (research on key technologies of primary frequency power oscillation mechanism analysis and inhibition measures in large-scale unit in Fujian power grid.No.52130417000J)
文摘This paper presents a method of tuning governor control parameters of an isolated hydropower generator considering the primary frequency performance and small-signal stability. First, generators that can be operated in isolated state are identified. Second, different schemes are proposed for generator mode switching from on-grid to off-grid state through comparison and mechanism analysis. Third, the time domain model and frequency domain model of the isolated generator governor are constructed to respectively estimate the primary frequency performance and small signal stability. Parameter sets that satisfy the primary frequency performance and small signal stability are acquired as optimal values of governor control parameters. Finally, the measurement-based parameters of the governor are identified and validated using simulations to demonstrate the feasibility and effectiveness of the method.
基金National Natural Science Foundation of China(51977160)“Voltage Self balancing Control Method for Modular Multilevel Converter Based on Switching State Matrix”.
文摘The application of virtual synchronous generator(VSG)control in flywheel energy storage systems(FESS)is an effective solution for addressing the challenges related to reduced inertia and inadequate power supply in microgrids.Considering the significant variations among individual units within a flywheel array and the poor frequency regulation performance under conventional control approaches,this paper proposes an adaptive VSG control strategy for a flywheel energy storage array(FESA).First,by leveraging the FESA model,a variable acceleration factor is integrated into the speed-balance control strategy to effectively achieve better state of charge(SOC)equalization across units.Furthermore,energy control with a dead zone is introduced to prevent SOC of the FESA from exceeding the limit.The dead zone parameter is designed based on the SOC warning intervals of the flywheel array to mitigate its impact on regular operation.In addition,VSG technology is applied for the grid-connected control of the FESA,and the damping characteristic of the VSG is decoupled from the primary frequency regulation through power differential feedback.This ensures optimal dynamic performance while reducing the need for frequent involvement in frequency regulation.Subsequently,a parameter design method is developed through a small-signal stability analysis.Consequently,considering the SOC of the FESA,an adaptive control strategy for the inertia damping and the P/ωdroop coefficient of the VSG control is proposed to optimize the grid support services of the FESA.Finally,the effectiveness of the proposed control methods is demonstrated through electromagnetic transient simulations using MATLAB/Simulink.
文摘In this paper, an attempt has been made to produce a recipient system of wireless charge for a simple hearing aid so that electrical signal would be generated through detecting and receiving radio frequency waves (RF). The purpose of this design is to receive wireless charge for hearing aids and basically for any electronic device which is not required to a high energy for being setup. In this study, it has been demonstrated that as the amount of radio receiving energy increases, distance of receiver from antenna should be decreased;otherwise, either maximum amount of the receiving energy, or signal power density of the transmitter should be increased. Since it is impossible to be performed, it is decided to set up an energy receiving system constructed by rectenna and charge Circuit and to adjust their parameters to provide energy requirements for a device with low-power consumption. In this paper, different components of an energy receiving system from radio frequency band have been mentioned and a diagram block has been suggested. Subsequently, input impedance of designed antenna has been adjusted by provided relations. This impedance should be adjusted with the total impedance of regarded hearing aid Circuit by which the highest amount of received signal power is transferred to the battery of hearing aids. Received signal is converted to a dc voltage by rectifier diode. Finally, by applying a voltage regulator which has been designed using a common-collector amplifier not only the output voltage is kept constant, but the power is also strengthened. The battery of the hearing aids will be charged using the obtained power and voltage.
文摘A continuous-time Model Predictive Controller was proposed using Kautz function in order to improve the performance of Load Frequency Control(LFC).A dynamic model of an interconnected power system was used for Model Predictive Controller(MPC)design.MPC predicts the future trajectory of the dynamic model by calculating the optimal closed loop feedback gain matrix.In this paper,the optimal closed loop feedback gain matrix was calculated using Kautz function.Being an Orthonormal Basis Function(OBF),Kautz function has an advantage of solving complex pole-based nonlinear system.Genetic Algorithm(GA)was applied to optimally tune the Kautz function-based MPC.A constraint based on phase plane analysis was implemented with the cost function in order to improve the robustness of the Kautz function-based MPC.The proposed method was simulated with three area interconnected power system and the efficiency of the proposed method was measured and exhibited by comparing with conventional Proportional and Integral(PI)controller and Linear Quadratic Regulation(LQR).
基金support from the National Key Research and Development Plan (No.2016YFC0801800)the National Natural Science Foundation of China (No.51404263)+2 种基金the National Natural Science Foundation of Jiangsu (No.BK20130203)the Project Funded by the Priority Academic Program Development (PAPD) of Jiangsu Higher Education Institutionsthe Fundamental Research Funds for the Central Universities (Nos.2014XT02 and 2014ZDPY03)
文摘In view of the difficulty of automatic adjustment, the recovery lag and the major accident potential of the mine ventilation system, an experimental model of the pipe net was established according to the typical one mine and one working face ventilation system of Daliuta coal mine. Using the best uniform approximation method of Chebyshev interpolation to fit the fan performance curve, we experimentally determined fan characteristics with different frequencies and establish the data base for the curves. Based on ventilation network monitoring theory, we designed a monitoring system for ventilation network parameter monitoring and fan operating frequency automatic control. Using the absolute methane emission quantity to predict the air quantity requirement of branch and fan frequency, we established a f-ω regulation model based on fan frequency and absolute methane emission quantity. After analysing methane emission and distribution characteristics, using CO_2 to simulate the methane emission characteristics from a working face, we verified the correctness and rationality of the f-ω regulation model. The fan operation frequency is adjusted by the method of air adjustment change with methane emission quantity and the curve searching method after determining air quantity requirements. The results show that the air quantity in a branch strictly changes according to the f-ω regulation model, in the airincreasing dilution by fan frequency regulation, the CO_2 concentration is limited to the set threshold value. The paper verifies the practicability of a frequency regulation system and the feasibility of the frequency adjustment scheme and provides guidance for the construction of automatic frequency conversion control system in coal mine ventilation networks.
基金supported by the National Key Research and Development Program of China(No.2023YFB2406800).
文摘The increasing integration of renewable energy sources poses great challenges to the power system frequency se curity.However,the existing electricity market mechanism lacks integration and incentives for emerging frequency regula tion(FR)resources such as wind power generators(WPGs),which may reduce their motivation to provide frequency sup port and further deteriorate the frequency dynamics.In this pa per,a market scheduling and pricing method for comprehen sive frequency regulation services(FRSs)is proposed.First,a modeling approach for flexible FR capabilities of WPGs is pro posed based on the mechanism of inertia control and power re serve control.Subsequently,considering the differences in in verter control strategies,a novel system frequency response model with grid-following and grid-forming inverters is estab lished.Combined with the automatic generation control,the fre quency security constraints of the whole FR process are de rived,and integrated into the market scheduling model to cooptimize the energy and FRSs.Finally,by distinguishing the contributions of various types of resources in different FR stag es,a differentiated pricing scheme is proposed to incentivize producers with various regulation qualities to provide FRSs.The effectiveness of the proposed method is verified on the mod ified IEEE 6-bus system and the IEEE RTS-79 system.