In the present paper we consider sequences of rational functions with a bounded number or free poles con- verging uniformly with a maximum geometric rate to a holomorphic function on a regular set,and we examine the l...In the present paper we consider sequences of rational functions with a bounded number or free poles con- verging uniformly with a maximum geometric rate to a holomorphic function on a regular set,and we examine the limiting distribution of the Zeros and its relations with the phenomenon of overconvergence.Our results further extend the well known classical theory of overconvergence and the zeros of sections of Taylor series.展开更多
The N3 power plant of Taipower is located in the southern tip of Taiwan and connected to the power pool by four out-linking 345-kV overhead transmission circuits. There are two 951-MW generators. Each generator occupi...The N3 power plant of Taipower is located in the southern tip of Taiwan and connected to the power pool by four out-linking 345-kV overhead transmission circuits. There are two 951-MW generators. Each generator occupied 11% of the system peak load in 1985 when the generator was in commercial operation. Since Taipower is an isolated system, at the N-2 conditions, those generators were reduced to 75% loading to protect the power system. By the way, to avoid damage of negative sequence current (NSC), the limits of the N3 power plant are stricter than those in the IEEE Standard. However, in 2010, the capacity ratio of each generator in the plant to the system peak load has been reduced to 3% only. To increase the economic benefit of those generators, it is required to reassess the operation limits of NSC. EMTP was used to calculate the levels of NSC from the out-linking transmission circuits. From the results of this study, the effects of NSC could be ignored when the four out-linking circuits are in N-0, N-1, and N-2 conditions. The generators can be operated in full loading under these conditions. The modifications to the NSC limits of the N3 power plant are also suggested.展开更多
In this paper we propose a new class of ternary Zero Correlation Zone (ZCZ) sequence sets based on binary ZCZ sequence sets construction. It is shown that the proposed ternary ZCZ sequence sets can reach the upper bou...In this paper we propose a new class of ternary Zero Correlation Zone (ZCZ) sequence sets based on binary ZCZ sequence sets construction. It is shown that the proposed ternary ZCZ sequence sets can reach the upper bound on the ZCZ sequences. The performance of the proposed sequences set in asynchronous Direct Sequence-Code Division Multiple Access (DS-CDMA) system is evaluated. In the simulation we used two types of channels: Additive White Gaussian Noise (AWGN) and frequency non-selective fading with AWGN noise. The proposed ternary ZCZ sequence sets show better results, in term of Bit Error Rate (BER), than Hayashi’s ternary ZCZ sequence sets.展开更多
To improve the accuracy of the stator winding fault diagnosis in induction motor,a new diagnostic method based on the Hilbert-Huang transform(HHT)was proposed.The ratio of fundamental zero sequence voltage to positive...To improve the accuracy of the stator winding fault diagnosis in induction motor,a new diagnostic method based on the Hilbert-Huang transform(HHT)was proposed.The ratio of fundamental zero sequence voltage to positive sequence voltage after switch-off was selected as the stator fault characteristic,which could effectively avoid the influence of the supply unbalance and the load fluctuation,and directly represent the asymmetry in the stator.Using the empirical mode decomposition(EMD)based on HHT,the zero sequence voltage after switch-off was decomposed and the fundamental component was extracted.Then,the fault characteristic can be acquired.Experimental results on a 4-kW induction motor demonstrate the feasibility and effectiveness of this method.展开更多
This paper proposes a zer o current and zero voltage switching (ZCZVS) PWM Boost full bridge (FB) conve rter. With series inductors, the leading switches can realize zero current swit ching (ZCS) in a wide load ra...This paper proposes a zer o current and zero voltage switching (ZCZVS) PWM Boost full bridge (FB) conve rter. With series inductors, the leading switches can realize zero current swit ching (ZCS) in a wide load range using the energy of the output capacitor. Ma king use of parasitic capacitors of the lagging switches and parallel auxiliary i nductance with the primary winding of the transformer, the lagging switches can realize zero voltage switching (ZVS) under any load. Compared with the ZCS PWM Boost FB converter, the new converter has no current duty cycle loss. Operat ional principle and parameter design are analyzed. Experimental results verify the effectiveness of the proposed converter.展开更多
Voltage sag is one of the most common power quality disturbances in industry,which causes huge inrush currents in stator windings of induction motors,and adversely impacts the motor secure operation.This paper firstly...Voltage sag is one of the most common power quality disturbances in industry,which causes huge inrush currents in stator windings of induction motors,and adversely impacts the motor secure operation.This paper firstly introduces a 2D Time-Stepping multi-slice finite element method(2D T-S multi-slice FEM)which is used for calculating the magnetic field distribution in induction motors under different sag events.Then the paper deduces the transient analytical expression of stator inrush current based on the classical theory of AC motors and presents a separation method for the positive,negative and zero sequence values based on instantaneous currents.With this method,the paper studies the influences of voltage sag amplitude,phase-angle jump and initial phase angle on the stator positive-and negative-sequence peak currents of 5.5 kW and 55 kW induction motors.This paper further proposes a motor protection method under voltage sag condition with the stator negative-sequence peak currents as the protection threshold,so that the protection false trip can be avoided effectively.Finally,the calculation and analysis results are validated by the comparison of calculated and measured stator peak value of the 5.5 kW induction motor.展开更多
In this paper, a multicarrier DS-CDMA system which employs Z-Complementary Se- quences (ZCS) as spreading code is investigated. The new system can not only eliminate multipath interference and Multiple Access Interfer...In this paper, a multicarrier DS-CDMA system which employs Z-Complementary Se- quences (ZCS) as spreading code is investigated. The new system can not only eliminate multipath interference and Multiple Access Interference (MAI), but also support flexible number of users com- pared with system using Orthogonal Complementary (OC) codes. Multicarrier DS-CDMA using OC codes can be regarded as a special case of our proposed system. Zero Correlation Zone (ZCZ) of ZCS can be flexibly adjusted to meet the requirements on the user number and maximum multipath and in- ter-user delay, in this way, more users can be supported without losing interference-free property. The effectiveness of the proposed system is validated through theoretical analysis and simulation results.展开更多
In an Approximately Synchronized Code Division Multiple Access (AS-CDMA) commu-nication system,a family with large number of Zero Correlation Zone (ZCZ) sequences is desired,which can satisfy the rapid increase of use...In an Approximately Synchronized Code Division Multiple Access (AS-CDMA) commu-nication system,a family with large number of Zero Correlation Zone (ZCZ) sequences is desired,which can satisfy the rapid increase of users. This paper presents a method to generate a (2L ,2M ,Zc' z )-ZCZsequence family from an original (L ,M ,Z cz)-ZCZsequence family,where Z c' z =Zcz if Z czis even and Z c' z = Zcz 1if Z czis odd. This method can also recursively act on a ZCZ sequence family to construct a series of ZCZ sequence families with large sequence number and zero correlation zone length identical to or one less than that of original ZCZ sequences.展开更多
由于柔性多状态开关(soft normal open point,SNOP)复杂的控制策略及其弱馈特性,传统配电网故障定位方法难以适用于柔性互联配电网(flexible distribution network,FDN)。因此,文中提出一种利用电流正序分量波形相似性进行FDN故障区段...由于柔性多状态开关(soft normal open point,SNOP)复杂的控制策略及其弱馈特性,传统配电网故障定位方法难以适用于柔性互联配电网(flexible distribution network,FDN)。因此,文中提出一种利用电流正序分量波形相似性进行FDN故障区段定位的方法。首先,针对SNOP的典型控制策略,分析FDN的短路故障特征。其次,计算配电网中不同故障位置电流正序分量的Tanimoto系数,通过对比不同位置的电流正序分量波形相似性,构建FDN短路故障定位判据,并通过Teager能量算子(Teager energy operation,TEO)实现故障时刻的精确定位,利用智能配电终端(smart terminal unit,STU)传递信息。最后,通过建模仿真对所提方法进行分析验证,结果表明该方法能够对故障区段进行准确定位,不受故障位置、故障类型、过渡电阻、采样频率及通信延时等因素的影响,验证了该方法的可行性与有效性。展开更多
零序电流互感器(current transformer,CT)测量精度问题一直是限制配电网故障选线准确率的关键性问题,现有研究方法在理论层面已较为成熟,但在现场使用中受限于零序CT测量精度,耐过渡电阻能力往往不佳。灵活接地系统是一种新型接地方式,...零序电流互感器(current transformer,CT)测量精度问题一直是限制配电网故障选线准确率的关键性问题,现有研究方法在理论层面已较为成熟,但在现场使用中受限于零序CT测量精度,耐过渡电阻能力往往不佳。灵活接地系统是一种新型接地方式,系统感知永久性接地故障后,于中性点投入并联小电阻,使得配电网接地方式发生转变,从而导致同一电气信号量呈现两种完全不同的故障特征,故障信息量增加了一倍,综合利用两阶段故障特征有望突破现有故障选线装置性能极限,摆脱选线装置对零序CT测量精度的依赖。为此,该文首先分析了灵活接地系统不同阶段各电气量的故障特征,之后结合灵活接地系统特点提出了一种基于零序电流幅值比的高阻接地故障选线方法,最后通过合理设计选线算法,剔除误差较大数据,最大程度降低保护对零序CT测量精度的依赖。实时数字仿真系统(real time digital simulation system,RTDS)以及低压实验平台实验结果表明,该方法不受零序CT极性反接与相位测量误差影响,且无需故障信息间的横向比较,具有耐过渡电阻能力强、可靠性高、对零序CT测量精度要求低、易实现等优点。展开更多
文摘In the present paper we consider sequences of rational functions with a bounded number or free poles con- verging uniformly with a maximum geometric rate to a holomorphic function on a regular set,and we examine the limiting distribution of the Zeros and its relations with the phenomenon of overconvergence.Our results further extend the well known classical theory of overconvergence and the zeros of sections of Taylor series.
文摘The N3 power plant of Taipower is located in the southern tip of Taiwan and connected to the power pool by four out-linking 345-kV overhead transmission circuits. There are two 951-MW generators. Each generator occupied 11% of the system peak load in 1985 when the generator was in commercial operation. Since Taipower is an isolated system, at the N-2 conditions, those generators were reduced to 75% loading to protect the power system. By the way, to avoid damage of negative sequence current (NSC), the limits of the N3 power plant are stricter than those in the IEEE Standard. However, in 2010, the capacity ratio of each generator in the plant to the system peak load has been reduced to 3% only. To increase the economic benefit of those generators, it is required to reassess the operation limits of NSC. EMTP was used to calculate the levels of NSC from the out-linking transmission circuits. From the results of this study, the effects of NSC could be ignored when the four out-linking circuits are in N-0, N-1, and N-2 conditions. The generators can be operated in full loading under these conditions. The modifications to the NSC limits of the N3 power plant are also suggested.
文摘In this paper we propose a new class of ternary Zero Correlation Zone (ZCZ) sequence sets based on binary ZCZ sequence sets construction. It is shown that the proposed ternary ZCZ sequence sets can reach the upper bound on the ZCZ sequences. The performance of the proposed sequences set in asynchronous Direct Sequence-Code Division Multiple Access (DS-CDMA) system is evaluated. In the simulation we used two types of channels: Additive White Gaussian Noise (AWGN) and frequency non-selective fading with AWGN noise. The proposed ternary ZCZ sequence sets show better results, in term of Bit Error Rate (BER), than Hayashi’s ternary ZCZ sequence sets.
基金Project (No. 50677060) supported by the National Natural ScienceFoundation of China
文摘To improve the accuracy of the stator winding fault diagnosis in induction motor,a new diagnostic method based on the Hilbert-Huang transform(HHT)was proposed.The ratio of fundamental zero sequence voltage to positive sequence voltage after switch-off was selected as the stator fault characteristic,which could effectively avoid the influence of the supply unbalance and the load fluctuation,and directly represent the asymmetry in the stator.Using the empirical mode decomposition(EMD)based on HHT,the zero sequence voltage after switch-off was decomposed and the fundamental component was extracted.Then,the fault characteristic can be acquired.Experimental results on a 4-kW induction motor demonstrate the feasibility and effectiveness of this method.
文摘This paper proposes a zer o current and zero voltage switching (ZCZVS) PWM Boost full bridge (FB) conve rter. With series inductors, the leading switches can realize zero current swit ching (ZCS) in a wide load range using the energy of the output capacitor. Ma king use of parasitic capacitors of the lagging switches and parallel auxiliary i nductance with the primary winding of the transformer, the lagging switches can realize zero voltage switching (ZVS) under any load. Compared with the ZCS PWM Boost FB converter, the new converter has no current duty cycle loss. Operat ional principle and parameter design are analyzed. Experimental results verify the effectiveness of the proposed converter.
基金This work was supported in part by the National Natural Science Foundation of China under Grant51307050。
文摘Voltage sag is one of the most common power quality disturbances in industry,which causes huge inrush currents in stator windings of induction motors,and adversely impacts the motor secure operation.This paper firstly introduces a 2D Time-Stepping multi-slice finite element method(2D T-S multi-slice FEM)which is used for calculating the magnetic field distribution in induction motors under different sag events.Then the paper deduces the transient analytical expression of stator inrush current based on the classical theory of AC motors and presents a separation method for the positive,negative and zero sequence values based on instantaneous currents.With this method,the paper studies the influences of voltage sag amplitude,phase-angle jump and initial phase angle on the stator positive-and negative-sequence peak currents of 5.5 kW and 55 kW induction motors.This paper further proposes a motor protection method under voltage sag condition with the stator negative-sequence peak currents as the protection threshold,so that the protection false trip can be avoided effectively.Finally,the calculation and analysis results are validated by the comparison of calculated and measured stator peak value of the 5.5 kW induction motor.
基金Supported by the National Natural Science Foundation of China (No.60772087, No.90604035)111 Project (No.111- 2-14)
文摘In this paper, a multicarrier DS-CDMA system which employs Z-Complementary Se- quences (ZCS) as spreading code is investigated. The new system can not only eliminate multipath interference and Multiple Access Interference (MAI), but also support flexible number of users com- pared with system using Orthogonal Complementary (OC) codes. Multicarrier DS-CDMA using OC codes can be regarded as a special case of our proposed system. Zero Correlation Zone (ZCZ) of ZCS can be flexibly adjusted to meet the requirements on the user number and maximum multipath and in- ter-user delay, in this way, more users can be supported without losing interference-free property. The effectiveness of the proposed system is validated through theoretical analysis and simulation results.
基金the National Natural Science Foundation of China (No.60673081)the National "863" Project (No.2006AA01Z417).
文摘In an Approximately Synchronized Code Division Multiple Access (AS-CDMA) commu-nication system,a family with large number of Zero Correlation Zone (ZCZ) sequences is desired,which can satisfy the rapid increase of users. This paper presents a method to generate a (2L ,2M ,Zc' z )-ZCZsequence family from an original (L ,M ,Z cz)-ZCZsequence family,where Z c' z =Zcz if Z czis even and Z c' z = Zcz 1if Z czis odd. This method can also recursively act on a ZCZ sequence family to construct a series of ZCZ sequence families with large sequence number and zero correlation zone length identical to or one less than that of original ZCZ sequences.
文摘由于柔性多状态开关(soft normal open point,SNOP)复杂的控制策略及其弱馈特性,传统配电网故障定位方法难以适用于柔性互联配电网(flexible distribution network,FDN)。因此,文中提出一种利用电流正序分量波形相似性进行FDN故障区段定位的方法。首先,针对SNOP的典型控制策略,分析FDN的短路故障特征。其次,计算配电网中不同故障位置电流正序分量的Tanimoto系数,通过对比不同位置的电流正序分量波形相似性,构建FDN短路故障定位判据,并通过Teager能量算子(Teager energy operation,TEO)实现故障时刻的精确定位,利用智能配电终端(smart terminal unit,STU)传递信息。最后,通过建模仿真对所提方法进行分析验证,结果表明该方法能够对故障区段进行准确定位,不受故障位置、故障类型、过渡电阻、采样频率及通信延时等因素的影响,验证了该方法的可行性与有效性。
文摘零序电流互感器(current transformer,CT)测量精度问题一直是限制配电网故障选线准确率的关键性问题,现有研究方法在理论层面已较为成熟,但在现场使用中受限于零序CT测量精度,耐过渡电阻能力往往不佳。灵活接地系统是一种新型接地方式,系统感知永久性接地故障后,于中性点投入并联小电阻,使得配电网接地方式发生转变,从而导致同一电气信号量呈现两种完全不同的故障特征,故障信息量增加了一倍,综合利用两阶段故障特征有望突破现有故障选线装置性能极限,摆脱选线装置对零序CT测量精度的依赖。为此,该文首先分析了灵活接地系统不同阶段各电气量的故障特征,之后结合灵活接地系统特点提出了一种基于零序电流幅值比的高阻接地故障选线方法,最后通过合理设计选线算法,剔除误差较大数据,最大程度降低保护对零序CT测量精度的依赖。实时数字仿真系统(real time digital simulation system,RTDS)以及低压实验平台实验结果表明,该方法不受零序CT极性反接与相位测量误差影响,且无需故障信息间的横向比较,具有耐过渡电阻能力强、可靠性高、对零序CT测量精度要求低、易实现等优点。