In the present paper we consider sequences of rational functions with a bounded number or free poles con- verging uniformly with a maximum geometric rate to a holomorphic function on a regular set,and we examine the l...In the present paper we consider sequences of rational functions with a bounded number or free poles con- verging uniformly with a maximum geometric rate to a holomorphic function on a regular set,and we examine the limiting distribution of the Zeros and its relations with the phenomenon of overconvergence.Our results further extend the well known classical theory of overconvergence and the zeros of sections of Taylor series.展开更多
In this paper we propose a new class of ternary Zero Correlation Zone (ZCZ) sequence sets based on binary ZCZ sequence sets construction. It is shown that the proposed ternary ZCZ sequence sets can reach the upper bou...In this paper we propose a new class of ternary Zero Correlation Zone (ZCZ) sequence sets based on binary ZCZ sequence sets construction. It is shown that the proposed ternary ZCZ sequence sets can reach the upper bound on the ZCZ sequences. The performance of the proposed sequences set in asynchronous Direct Sequence-Code Division Multiple Access (DS-CDMA) system is evaluated. In the simulation we used two types of channels: Additive White Gaussian Noise (AWGN) and frequency non-selective fading with AWGN noise. The proposed ternary ZCZ sequence sets show better results, in term of Bit Error Rate (BER), than Hayashi’s ternary ZCZ sequence sets.展开更多
To improve the accuracy of the stator winding fault diagnosis in induction motor,a new diagnostic method based on the Hilbert-Huang transform(HHT)was proposed.The ratio of fundamental zero sequence voltage to positive...To improve the accuracy of the stator winding fault diagnosis in induction motor,a new diagnostic method based on the Hilbert-Huang transform(HHT)was proposed.The ratio of fundamental zero sequence voltage to positive sequence voltage after switch-off was selected as the stator fault characteristic,which could effectively avoid the influence of the supply unbalance and the load fluctuation,and directly represent the asymmetry in the stator.Using the empirical mode decomposition(EMD)based on HHT,the zero sequence voltage after switch-off was decomposed and the fundamental component was extracted.Then,the fault characteristic can be acquired.Experimental results on a 4-kW induction motor demonstrate the feasibility and effectiveness of this method.展开更多
In this paper, a multicarrier DS-CDMA system which employs Z-Complementary Se- quences (ZCS) as spreading code is investigated. The new system can not only eliminate multipath interference and Multiple Access Interfer...In this paper, a multicarrier DS-CDMA system which employs Z-Complementary Se- quences (ZCS) as spreading code is investigated. The new system can not only eliminate multipath interference and Multiple Access Interference (MAI), but also support flexible number of users com- pared with system using Orthogonal Complementary (OC) codes. Multicarrier DS-CDMA using OC codes can be regarded as a special case of our proposed system. Zero Correlation Zone (ZCZ) of ZCS can be flexibly adjusted to meet the requirements on the user number and maximum multipath and in- ter-user delay, in this way, more users can be supported without losing interference-free property. The effectiveness of the proposed system is validated through theoretical analysis and simulation results.展开更多
In an Approximately Synchronized Code Division Multiple Access (AS-CDMA) commu-nication system,a family with large number of Zero Correlation Zone (ZCZ) sequences is desired,which can satisfy the rapid increase of use...In an Approximately Synchronized Code Division Multiple Access (AS-CDMA) commu-nication system,a family with large number of Zero Correlation Zone (ZCZ) sequences is desired,which can satisfy the rapid increase of users. This paper presents a method to generate a (2L ,2M ,Zc' z )-ZCZsequence family from an original (L ,M ,Z cz)-ZCZsequence family,where Z c' z =Zcz if Z czis even and Z c' z = Zcz 1if Z czis odd. This method can also recursively act on a ZCZ sequence family to construct a series of ZCZ sequence families with large sequence number and zero correlation zone length identical to or one less than that of original ZCZ sequences.展开更多
各种清洁能源和电动汽车的大量接入给配电线路参数的准确性提出了更高要求,为此提出一种利用馈线补偿电容器投入产生的暂态特征测量线路参数的方法。通过对系统和电容器中性点运行方式影响下电容器同期和非同期投入序网开展时域分析,确...各种清洁能源和电动汽车的大量接入给配电线路参数的准确性提出了更高要求,为此提出一种利用馈线补偿电容器投入产生的暂态特征测量线路参数的方法。通过对系统和电容器中性点运行方式影响下电容器同期和非同期投入序网开展时域分析,确定最后一相电容器投入暂态特征与序网拓扑及参数间的耦合关系,建立基于投入暂态频率和衰减系数的线路参数单点测量模型,给出基于最小二乘-旋转不变技术(total least square-estimating signal parameter via rotational invariance techniques,TLS-ESPRIT)的暂态特性提取方法。仿真和模拟实验结果表明,当有充足数据量支撑暂态特征提取时,该文算法对线路正序参数的测量误差在4%以内,对零序参数的测量误差略高,可用于配电线路参数经常性测量。展开更多
零序电流互感器(current transformer,CT)测量精度问题一直是限制配电网故障选线准确率的关键性问题,现有研究方法在理论层面已较为成熟,但在现场使用中受限于零序CT测量精度,耐过渡电阻能力往往不佳。灵活接地系统是一种新型接地方式,...零序电流互感器(current transformer,CT)测量精度问题一直是限制配电网故障选线准确率的关键性问题,现有研究方法在理论层面已较为成熟,但在现场使用中受限于零序CT测量精度,耐过渡电阻能力往往不佳。灵活接地系统是一种新型接地方式,系统感知永久性接地故障后,于中性点投入并联小电阻,使得配电网接地方式发生转变,从而导致同一电气信号量呈现两种完全不同的故障特征,故障信息量增加了一倍,综合利用两阶段故障特征有望突破现有故障选线装置性能极限,摆脱选线装置对零序CT测量精度的依赖。为此,该文首先分析了灵活接地系统不同阶段各电气量的故障特征,之后结合灵活接地系统特点提出了一种基于零序电流幅值比的高阻接地故障选线方法,最后通过合理设计选线算法,剔除误差较大数据,最大程度降低保护对零序CT测量精度的依赖。实时数字仿真系统(real time digital simulation system,RTDS)以及低压实验平台实验结果表明,该方法不受零序CT极性反接与相位测量误差影响,且无需故障信息间的横向比较,具有耐过渡电阻能力强、可靠性高、对零序CT测量精度要求低、易实现等优点。展开更多
文摘In the present paper we consider sequences of rational functions with a bounded number or free poles con- verging uniformly with a maximum geometric rate to a holomorphic function on a regular set,and we examine the limiting distribution of the Zeros and its relations with the phenomenon of overconvergence.Our results further extend the well known classical theory of overconvergence and the zeros of sections of Taylor series.
文摘In this paper we propose a new class of ternary Zero Correlation Zone (ZCZ) sequence sets based on binary ZCZ sequence sets construction. It is shown that the proposed ternary ZCZ sequence sets can reach the upper bound on the ZCZ sequences. The performance of the proposed sequences set in asynchronous Direct Sequence-Code Division Multiple Access (DS-CDMA) system is evaluated. In the simulation we used two types of channels: Additive White Gaussian Noise (AWGN) and frequency non-selective fading with AWGN noise. The proposed ternary ZCZ sequence sets show better results, in term of Bit Error Rate (BER), than Hayashi’s ternary ZCZ sequence sets.
基金Project (No. 50677060) supported by the National Natural ScienceFoundation of China
文摘To improve the accuracy of the stator winding fault diagnosis in induction motor,a new diagnostic method based on the Hilbert-Huang transform(HHT)was proposed.The ratio of fundamental zero sequence voltage to positive sequence voltage after switch-off was selected as the stator fault characteristic,which could effectively avoid the influence of the supply unbalance and the load fluctuation,and directly represent the asymmetry in the stator.Using the empirical mode decomposition(EMD)based on HHT,the zero sequence voltage after switch-off was decomposed and the fundamental component was extracted.Then,the fault characteristic can be acquired.Experimental results on a 4-kW induction motor demonstrate the feasibility and effectiveness of this method.
基金Supported by the National Natural Science Foundation of China (No.60772087, No.90604035)111 Project (No.111- 2-14)
文摘In this paper, a multicarrier DS-CDMA system which employs Z-Complementary Se- quences (ZCS) as spreading code is investigated. The new system can not only eliminate multipath interference and Multiple Access Interference (MAI), but also support flexible number of users com- pared with system using Orthogonal Complementary (OC) codes. Multicarrier DS-CDMA using OC codes can be regarded as a special case of our proposed system. Zero Correlation Zone (ZCZ) of ZCS can be flexibly adjusted to meet the requirements on the user number and maximum multipath and in- ter-user delay, in this way, more users can be supported without losing interference-free property. The effectiveness of the proposed system is validated through theoretical analysis and simulation results.
基金the National Natural Science Foundation of China (No.60673081)the National "863" Project (No.2006AA01Z417).
文摘In an Approximately Synchronized Code Division Multiple Access (AS-CDMA) commu-nication system,a family with large number of Zero Correlation Zone (ZCZ) sequences is desired,which can satisfy the rapid increase of users. This paper presents a method to generate a (2L ,2M ,Zc' z )-ZCZsequence family from an original (L ,M ,Z cz)-ZCZsequence family,where Z c' z =Zcz if Z czis even and Z c' z = Zcz 1if Z czis odd. This method can also recursively act on a ZCZ sequence family to construct a series of ZCZ sequence families with large sequence number and zero correlation zone length identical to or one less than that of original ZCZ sequences.
文摘各种清洁能源和电动汽车的大量接入给配电线路参数的准确性提出了更高要求,为此提出一种利用馈线补偿电容器投入产生的暂态特征测量线路参数的方法。通过对系统和电容器中性点运行方式影响下电容器同期和非同期投入序网开展时域分析,确定最后一相电容器投入暂态特征与序网拓扑及参数间的耦合关系,建立基于投入暂态频率和衰减系数的线路参数单点测量模型,给出基于最小二乘-旋转不变技术(total least square-estimating signal parameter via rotational invariance techniques,TLS-ESPRIT)的暂态特性提取方法。仿真和模拟实验结果表明,当有充足数据量支撑暂态特征提取时,该文算法对线路正序参数的测量误差在4%以内,对零序参数的测量误差略高,可用于配电线路参数经常性测量。
文摘零序电流互感器(current transformer,CT)测量精度问题一直是限制配电网故障选线准确率的关键性问题,现有研究方法在理论层面已较为成熟,但在现场使用中受限于零序CT测量精度,耐过渡电阻能力往往不佳。灵活接地系统是一种新型接地方式,系统感知永久性接地故障后,于中性点投入并联小电阻,使得配电网接地方式发生转变,从而导致同一电气信号量呈现两种完全不同的故障特征,故障信息量增加了一倍,综合利用两阶段故障特征有望突破现有故障选线装置性能极限,摆脱选线装置对零序CT测量精度的依赖。为此,该文首先分析了灵活接地系统不同阶段各电气量的故障特征,之后结合灵活接地系统特点提出了一种基于零序电流幅值比的高阻接地故障选线方法,最后通过合理设计选线算法,剔除误差较大数据,最大程度降低保护对零序CT测量精度的依赖。实时数字仿真系统(real time digital simulation system,RTDS)以及低压实验平台实验结果表明,该方法不受零序CT极性反接与相位测量误差影响,且无需故障信息间的横向比较,具有耐过渡电阻能力强、可靠性高、对零序CT测量精度要求低、易实现等优点。