An advanced direct chip attaching packaged two-dimensional ceramic thermal wind sensor is studied. The thermal wind sensor chip is fabricated by metal lift-off processes on the ceramic substrate. An advanced direct ch...An advanced direct chip attaching packaged two-dimensional ceramic thermal wind sensor is studied. The thermal wind sensor chip is fabricated by metal lift-off processes on the ceramic substrate. An advanced direct chip attaching (DCA) packaging is adopted and this new packaged method simplifies the processes of packaging further. Simulations of the advanced DCA packaged sensor based on computational fluid dynamics (CFD) model show the sensor can detect wind speed and direction effectively. The wind tunnel testing results show the advanced DCA packaged sensor can detect the wind direction from 0° to 360° and wind speed from 0 to 20 m/s with the error less than 0.5 m/s. The nonlinear fitting based least square method in Matlab is used to analyze the performance of the sensor.展开更多
In order to consider the influence of steel pole on the measurement of wind speed sensors and determinate the installation position of wind speed sensors, the flow field around wind speed sensors was investigated. Bas...In order to consider the influence of steel pole on the measurement of wind speed sensors and determinate the installation position of wind speed sensors, the flow field around wind speed sensors was investigated. Based on the three-dimensional steady Reynolds-averaged Navier-Stokes equations and k-ε double equations turbulent model, the field flow around the wind speed sensor and the steel pole along a high-speed railway was simulated on an unstructured grid. The grid-independent validation was conducted and the accuracy of the present numerical simulation method was validated by experiments and simulations carried out by previous researchers. Results show that the steel pole has a significant influence on the measurement results of wind speed sensors. As the distance between two wind speed sensors is varied from 0.3 to 1.0 m, the impact angles are less than ±20°, it is proposed that the distance between two wind speed sensors is 0.8 m at least, and the interval between wind speed sensors and the steel pole is more than 1.0 m with the sensors located on the upstream side.展开更多
In most areas of China, affected by the environment of low temperature and high humidity, the wind speed sensor and wind direction sensor are frozen and cannot output data in autumn, winter or the alternation of winte...In most areas of China, affected by the environment of low temperature and high humidity, the wind speed sensor and wind direction sensor are frozen and cannot output data in autumn, winter or the alternation of winter and spring. In order to solve the freezing situation of the wind sensor, this paper designs a new type of antifreeze wind speed sensor. After meteorology performance testing and field observation tests, the correlation coefficient of the observation data is demonstrated, and the data curve is fitted. The result shows the sensor is stable, and has a good antifreeze effect, the data output is reliable.展开更多
According to the verification regulation of the Wind Direction and Wind Speed Sensor of Automatic Meteorological Station[JJG(meteorological)004-2011],relying on the wind tunnel laboratory of Hebei meteorological measu...According to the verification regulation of the Wind Direction and Wind Speed Sensor of Automatic Meteorological Station[JJG(meteorological)004-2011],relying on the wind tunnel laboratory of Hebei meteorological measurement station,EL15-1 A type of wind speed sensor in the automatic weather station was verified.The experimental data of sensor verification in different laboratory environments were obtained through data comparison.Using standard wind speed measurement formula,the influence of laboratory temperature,humidity and air pressure on verification results was analyzed quantitatively.The results showed that laboratory temperature had the greatest influence on the verification results of this type of sensor,while the humidity and air pressure had less influence.Therefore,it should be noted that the temperature change in the laboratory should not be too large in the process of verification,so as to improve the accuracy of the verification results.展开更多
Wind energy is one of the widely applied renewable energies in the world. Wind turbine as the main wind energy converter at present has very complex technical system containing a huge number of components,actuators an...Wind energy is one of the widely applied renewable energies in the world. Wind turbine as the main wind energy converter at present has very complex technical system containing a huge number of components,actuators and sensors. However, despite of the hardware redundancy, sensor faults have often affected the wind turbine normal operation and thus caused energy generation loss. In this paper, aiming at the wind turbine hydraulic pitch system, data-driven design of process monitoring(PM) and diagnosis has been realized in the wind turbine benchmark. Fault tolerant control(FTC) strategies focused on sensor faults have also been presented here, where with the implementation of soft sensor the sensor fault can be handled and the performance of the system is improved. The performance of this method is demonstrated with the wind turbine benchmark provided by Math Works.展开更多
The measuring system for estimation of power of wind flow generated by the train movement has been created. The advantages of the proposed system are the cheapness and simple design. With its simplicity of design and ...The measuring system for estimation of power of wind flow generated by the train movement has been created. The advantages of the proposed system are the cheapness and simple design. With its simplicity of design and easy build-up of channels, designed measuring system can be used for a wide range of technical problems. This paper describes the design process, validation and conducting the first field test of this measuring system.展开更多
Chemical spills on complex geometry are difficult to model due to the uneven concentration distribution caused by air flow over ground obstacles. Computational fluid dynamics(CFD) is one of the powerful tools to estim...Chemical spills on complex geometry are difficult to model due to the uneven concentration distribution caused by air flow over ground obstacles. Computational fluid dynamics(CFD) is one of the powerful tools to estimate the building-resolving wind flow as well as pollutant dispersion. However, it takes too much time and requires enormous computational power in emergency situations. As a time demanding task, the estimation of the chemical spill consequence for emergency response requires abundant wind field information. In this paper, a comprehensive wind field reconstruction framework is proposed, providing the ability of parameter tuning for best reconstruction accuracy. The core of the framework is a data regression model built on principal component analysis(PCA) and extreme learning machine(ELM). To improve the accuracy, the wind field estimation from the regression model is further revised from local wind observations. The optimal placement of anemometers is provided based on the maximum projection on minimum eigenspace(MPME) algorithm. The fire dynamic simulator(FDS) generates high-resolution data of wind flow over complex geometries for the framework to be implemented. The reconstructed wind field is evaluated against simulation data and an overall reconstruction error of 9% is achieved. When used in real case,the error increases to around 12% since no convergence check is available. With parameter tuning abilities,the proposed framework provides an efficient way of reconstructing the wind flow in congested areas.展开更多
Deformation behavior of non-rigid airships in wind tunnel tests is studied by considering three factors, including internal pressure, flow velocity and angle of attack. Fiber Bragg grating strain sensors are used to m...Deformation behavior of non-rigid airships in wind tunnel tests is studied by considering three factors, including internal pressure, flow velocity and angle of attack. Fiber Bragg grating strain sensors are used to measure the deformation of non-rigid airships. Wind tunnel tests in the case of different flow velocities and angles of attack are conducted. The measurement results reveal that the airship deformation is in proportion to internal pressure. For the tensile region,the airship deformation is in proportion to flow velocity. Effects of angle of attack on structural deformation are more complicated and there is no clear relationship existing between airship deformation and angle of attack.展开更多
基金supported by the National Natural Science Foundation of China(No.61076071)
文摘An advanced direct chip attaching packaged two-dimensional ceramic thermal wind sensor is studied. The thermal wind sensor chip is fabricated by metal lift-off processes on the ceramic substrate. An advanced direct chip attaching (DCA) packaging is adopted and this new packaged method simplifies the processes of packaging further. Simulations of the advanced DCA packaged sensor based on computational fluid dynamics (CFD) model show the sensor can detect wind speed and direction effectively. The wind tunnel testing results show the advanced DCA packaged sensor can detect the wind direction from 0° to 360° and wind speed from 0 to 20 m/s with the error less than 0.5 m/s. The nonlinear fitting based least square method in Matlab is used to analyze the performance of the sensor.
基金Projects(U1334205,51205418)supported by the National Natural Science Foundation of ChinaProject(2014T002-A)supported by the Science and Technology Research Program of China Railway CorporationProject(132014)supported by the Fok Ying Tong Education Foundation of China
文摘In order to consider the influence of steel pole on the measurement of wind speed sensors and determinate the installation position of wind speed sensors, the flow field around wind speed sensors was investigated. Based on the three-dimensional steady Reynolds-averaged Navier-Stokes equations and k-ε double equations turbulent model, the field flow around the wind speed sensor and the steel pole along a high-speed railway was simulated on an unstructured grid. The grid-independent validation was conducted and the accuracy of the present numerical simulation method was validated by experiments and simulations carried out by previous researchers. Results show that the steel pole has a significant influence on the measurement results of wind speed sensors. As the distance between two wind speed sensors is varied from 0.3 to 1.0 m, the impact angles are less than ±20°, it is proposed that the distance between two wind speed sensors is 0.8 m at least, and the interval between wind speed sensors and the steel pole is more than 1.0 m with the sensors located on the upstream side.
文摘In most areas of China, affected by the environment of low temperature and high humidity, the wind speed sensor and wind direction sensor are frozen and cannot output data in autumn, winter or the alternation of winter and spring. In order to solve the freezing situation of the wind sensor, this paper designs a new type of antifreeze wind speed sensor. After meteorology performance testing and field observation tests, the correlation coefficient of the observation data is demonstrated, and the data curve is fitted. The result shows the sensor is stable, and has a good antifreeze effect, the data output is reliable.
文摘According to the verification regulation of the Wind Direction and Wind Speed Sensor of Automatic Meteorological Station[JJG(meteorological)004-2011],relying on the wind tunnel laboratory of Hebei meteorological measurement station,EL15-1 A type of wind speed sensor in the automatic weather station was verified.The experimental data of sensor verification in different laboratory environments were obtained through data comparison.Using standard wind speed measurement formula,the influence of laboratory temperature,humidity and air pressure on verification results was analyzed quantitatively.The results showed that laboratory temperature had the greatest influence on the verification results of this type of sensor,while the humidity and air pressure had less influence.Therefore,it should be noted that the temperature change in the laboratory should not be too large in the process of verification,so as to improve the accuracy of the verification results.
基金the National Natural Science Foundation of China(No.51205018)the Fundamental Research Funds for the Central Universities of China(No.FRF-TP-14-121A2)the Research Project of State Key Laboratory of Mechanical System and Vibration(No.MSV-2014-09)
文摘Wind energy is one of the widely applied renewable energies in the world. Wind turbine as the main wind energy converter at present has very complex technical system containing a huge number of components,actuators and sensors. However, despite of the hardware redundancy, sensor faults have often affected the wind turbine normal operation and thus caused energy generation loss. In this paper, aiming at the wind turbine hydraulic pitch system, data-driven design of process monitoring(PM) and diagnosis has been realized in the wind turbine benchmark. Fault tolerant control(FTC) strategies focused on sensor faults have also been presented here, where with the implementation of soft sensor the sensor fault can be handled and the performance of the system is improved. The performance of this method is demonstrated with the wind turbine benchmark provided by Math Works.
文摘The measuring system for estimation of power of wind flow generated by the train movement has been created. The advantages of the proposed system are the cheapness and simple design. With its simplicity of design and easy build-up of channels, designed measuring system can be used for a wide range of technical problems. This paper describes the design process, validation and conducting the first field test of this measuring system.
基金Supported by the National Natural Science Foundation of China(21706069and 61751305)the Fundamental Research Funds for the Central Universities(222201814039).
文摘Chemical spills on complex geometry are difficult to model due to the uneven concentration distribution caused by air flow over ground obstacles. Computational fluid dynamics(CFD) is one of the powerful tools to estimate the building-resolving wind flow as well as pollutant dispersion. However, it takes too much time and requires enormous computational power in emergency situations. As a time demanding task, the estimation of the chemical spill consequence for emergency response requires abundant wind field information. In this paper, a comprehensive wind field reconstruction framework is proposed, providing the ability of parameter tuning for best reconstruction accuracy. The core of the framework is a data regression model built on principal component analysis(PCA) and extreme learning machine(ELM). To improve the accuracy, the wind field estimation from the regression model is further revised from local wind observations. The optimal placement of anemometers is provided based on the maximum projection on minimum eigenspace(MPME) algorithm. The fire dynamic simulator(FDS) generates high-resolution data of wind flow over complex geometries for the framework to be implemented. The reconstructed wind field is evaluated against simulation data and an overall reconstruction error of 9% is achieved. When used in real case,the error increases to around 12% since no convergence check is available. With parameter tuning abilities,the proposed framework provides an efficient way of reconstructing the wind flow in congested areas.
基金supported by the National Natural Science Foundation of China(Nos.11472276,11332011 and 11502268)
文摘Deformation behavior of non-rigid airships in wind tunnel tests is studied by considering three factors, including internal pressure, flow velocity and angle of attack. Fiber Bragg grating strain sensors are used to measure the deformation of non-rigid airships. Wind tunnel tests in the case of different flow velocities and angles of attack are conducted. The measurement results reveal that the airship deformation is in proportion to internal pressure. For the tensile region,the airship deformation is in proportion to flow velocity. Effects of angle of attack on structural deformation are more complicated and there is no clear relationship existing between airship deformation and angle of attack.