Wind tunnel experiment and CFD(computational fluid dynamics)simulation with LES(large eddy simulation)have been conducted to investigate the characteristics of peak wind force coefficients of porous panels mounted on ...Wind tunnel experiment and CFD(computational fluid dynamics)simulation with LES(large eddy simulation)have been conducted to investigate the characteristics of peak wind force coefficients of porous panels mounted on the roofs of high-rise buildings.First,aerodynamic modelling of porous panels was discussed.The relation between pressure loss coefficient and porosity was obtained.Then,a wind tunnel experiment was conducted to measure the wind forces(net wind pressures)acting on solid and porous panels mounted on the roof of a high-rise building.Because it was difficult to measure the pressures on both sides of thin,porous panel at the same location simultaneously,we proposed to use the roof edge pressures near the panel for the panel’s inside-surface pressures.This experimental method was validated by a CFD simulation reproducing the wind tunnel experiment.The characteristics of peak wind force coefficients of porous panels mounted on the roofs of high-rise buildings were made clear.Finally,positive and negative peak wind force coefficients for designing the rooftop porous panels were proposed.展开更多
The present paper investigates the methods for estimating the maximum(positive)and the minimum(negative)peak wind force coefficients on domed free roofs based on the quasi-steady theory and the peak factor method,in w...The present paper investigates the methods for estimating the maximum(positive)and the minimum(negative)peak wind force coefficients on domed free roofs based on the quasi-steady theory and the peak factor method,in which the experimental results obtained from our previous studies(2019,2025)are used.Focus is on the distributions of the peak wind force coefficients along the centerline parallel to the wind direction considering that domed free roof is an axisymmetric body.Empirical formulas are provided to the distributions of mean wind force coefficient,RMS(root mean square)fluctuating wind force coefficient and peak factors as a function of the rise/span ratio of the roof and the turbulence intensity of the approach flow in the along-wind direction at the mean roof height.The proposed methods are validated by the experimental results for the peak wind force coefficients.The methods would provide useful information to structural engineers when estimating the design wind loads on cladding/components of domed free roofs.展开更多
Wind force coefficients for designing porous canopy roofs have been investigated based on a series of wind tunnel experiments. Gable, troughed and mono-sloped roofs were tested. The roof models were made of 0.5 mm thi...Wind force coefficients for designing porous canopy roofs have been investigated based on a series of wind tunnel experiments. Gable, troughed and mono-sloped roofs were tested. The roof models were made of 0.5 mm thick perforated duralumin plates, the porosity of which was changed from 0 to about 0.4. Overall aerodynamic forces and moments acting on the roof model were measured in a turbulent boundary layer with a six-component force balance for various wind directions. The results indicate that the wind loads on canopy roofs generally decrease with an increase in porosity of the roof. Assuming that the roof is rigid and supported by the four corner columns with no walls, the axial forces induced in the columns are regarded as the most important load effect for discussing the design wind loads. Two loading patterns causing the maximum tension and compression in the columns are considered. Based on a combination of the lift and moment coefficients, the design wind force coefficients on the windward and leeward halves of the roof are presented for the two loading patterns as a function of the roof pitch and porosity. The effect of porosity is taken into account as a reduction factor of the wind loads.展开更多
A discussion is made of the wind force coefficients for designing the main wind force resisting systems of H.P. (Hyperbolic-Paraboid)-shaped porous canopy roofs on the basis of a wind tunnel experiment. Roof models ...A discussion is made of the wind force coefficients for designing the main wind force resisting systems of H.P. (Hyperbolic-Paraboid)-shaped porous canopy roofs on the basis of a wind tunnel experiment. Roof models with a number of small circular holes were made of nylon resin using laser lithography. The porosity was changed from 0 (solid) to 0.4. Besides the porosity, the geometric parameters of the models were the rise to span ratio and slope of the roof. The overall aerodynamic forces and moments acting on a model were measured by a six-component force balance in a turbulent boundary layer. The results indicate that the porosity significantly reduces the wind loads. The design wind force coefficients for porous canopy roofs can be provided by those for solid roofs with the same configuration multiplied by a reduction factor. The proposed wind force coefficients are verified by a comparison of the load effect predicted by the proposed wind force coefficients with the maximum load effect obtained from dynamic analyses using the time history of wind force and moment coefficients. The axial forces induced in the columns supporting the roof are regarded as the load effect for discussing the design wind loads.展开更多
Wind loading on an H.P. (hyperbolic paraboloid) free roof has been investigated on the basis of a wind tunnel experiment. The roof models of 1 mm thickness were made of nylon resin using laser lithography. The param...Wind loading on an H.P. (hyperbolic paraboloid) free roof has been investigated on the basis of a wind tunnel experiment. The roof models of 1 mm thickness were made of nylon resin using laser lithography. The parameters under consideration are the rise to span ratio and slope of the roof. The overall aerodynamic forces and moments were measured by a six-component force balance in a turbulent boundary layer. Based on a combination of the lift and moment coefficients, the design wind force coefficients, CNW^* and CNL^*, on the windward and leeward halves of the roof are proposed. Focus is on the column axial forces induced by wind loading as the load effect for discussing the design wind loads, assuming that the roof is rigid and supported by four comer columns. Indeed, two pairs of CNW^* and CNL^*, generating the maximum tension and compression in the columns, are provided for each of the two or three wind directions parallel to the roof's diagonal lines. The proposed values of the wind force coefficients are compared with the specified values in the Australia/New-Zealand Standard for a limited range of rise to span ratio.展开更多
文摘Wind tunnel experiment and CFD(computational fluid dynamics)simulation with LES(large eddy simulation)have been conducted to investigate the characteristics of peak wind force coefficients of porous panels mounted on the roofs of high-rise buildings.First,aerodynamic modelling of porous panels was discussed.The relation between pressure loss coefficient and porosity was obtained.Then,a wind tunnel experiment was conducted to measure the wind forces(net wind pressures)acting on solid and porous panels mounted on the roof of a high-rise building.Because it was difficult to measure the pressures on both sides of thin,porous panel at the same location simultaneously,we proposed to use the roof edge pressures near the panel for the panel’s inside-surface pressures.This experimental method was validated by a CFD simulation reproducing the wind tunnel experiment.The characteristics of peak wind force coefficients of porous panels mounted on the roofs of high-rise buildings were made clear.Finally,positive and negative peak wind force coefficients for designing the rooftop porous panels were proposed.
文摘The present paper investigates the methods for estimating the maximum(positive)and the minimum(negative)peak wind force coefficients on domed free roofs based on the quasi-steady theory and the peak factor method,in which the experimental results obtained from our previous studies(2019,2025)are used.Focus is on the distributions of the peak wind force coefficients along the centerline parallel to the wind direction considering that domed free roof is an axisymmetric body.Empirical formulas are provided to the distributions of mean wind force coefficient,RMS(root mean square)fluctuating wind force coefficient and peak factors as a function of the rise/span ratio of the roof and the turbulence intensity of the approach flow in the along-wind direction at the mean roof height.The proposed methods are validated by the experimental results for the peak wind force coefficients.The methods would provide useful information to structural engineers when estimating the design wind loads on cladding/components of domed free roofs.
文摘Wind force coefficients for designing porous canopy roofs have been investigated based on a series of wind tunnel experiments. Gable, troughed and mono-sloped roofs were tested. The roof models were made of 0.5 mm thick perforated duralumin plates, the porosity of which was changed from 0 to about 0.4. Overall aerodynamic forces and moments acting on the roof model were measured in a turbulent boundary layer with a six-component force balance for various wind directions. The results indicate that the wind loads on canopy roofs generally decrease with an increase in porosity of the roof. Assuming that the roof is rigid and supported by the four corner columns with no walls, the axial forces induced in the columns are regarded as the most important load effect for discussing the design wind loads. Two loading patterns causing the maximum tension and compression in the columns are considered. Based on a combination of the lift and moment coefficients, the design wind force coefficients on the windward and leeward halves of the roof are presented for the two loading patterns as a function of the roof pitch and porosity. The effect of porosity is taken into account as a reduction factor of the wind loads.
文摘A discussion is made of the wind force coefficients for designing the main wind force resisting systems of H.P. (Hyperbolic-Paraboid)-shaped porous canopy roofs on the basis of a wind tunnel experiment. Roof models with a number of small circular holes were made of nylon resin using laser lithography. The porosity was changed from 0 (solid) to 0.4. Besides the porosity, the geometric parameters of the models were the rise to span ratio and slope of the roof. The overall aerodynamic forces and moments acting on a model were measured by a six-component force balance in a turbulent boundary layer. The results indicate that the porosity significantly reduces the wind loads. The design wind force coefficients for porous canopy roofs can be provided by those for solid roofs with the same configuration multiplied by a reduction factor. The proposed wind force coefficients are verified by a comparison of the load effect predicted by the proposed wind force coefficients with the maximum load effect obtained from dynamic analyses using the time history of wind force and moment coefficients. The axial forces induced in the columns supporting the roof are regarded as the load effect for discussing the design wind loads.
文摘Wind loading on an H.P. (hyperbolic paraboloid) free roof has been investigated on the basis of a wind tunnel experiment. The roof models of 1 mm thickness were made of nylon resin using laser lithography. The parameters under consideration are the rise to span ratio and slope of the roof. The overall aerodynamic forces and moments were measured by a six-component force balance in a turbulent boundary layer. Based on a combination of the lift and moment coefficients, the design wind force coefficients, CNW^* and CNL^*, on the windward and leeward halves of the roof are proposed. Focus is on the column axial forces induced by wind loading as the load effect for discussing the design wind loads, assuming that the roof is rigid and supported by four comer columns. Indeed, two pairs of CNW^* and CNL^*, generating the maximum tension and compression in the columns, are provided for each of the two or three wind directions parallel to the roof's diagonal lines. The proposed values of the wind force coefficients are compared with the specified values in the Australia/New-Zealand Standard for a limited range of rise to span ratio.