期刊文献+
共找到235篇文章
< 1 2 12 >
每页显示 20 50 100
Diagnosis of Hydrogen Plasma in a Miniature Penning Ion Source by Double Probes 被引量:2
1
作者 金大志 杨中海 +1 位作者 肖坤祥 戴晶怡 《Plasma Science and Technology》 SCIE EI CAS CSCD 2009年第1期48-51,共4页
Parameters of hydrogen plasma in a miniature Penning discharge ion source, including the electron temperature and the electron density, were measured by using double probes. The results indicate that the electron dens... Parameters of hydrogen plasma in a miniature Penning discharge ion source, including the electron temperature and the electron density, were measured by using double probes. The results indicate that the electron density increases and the electron temperature decreases with the increase in gas pressure and the discharge current. The electron temperature is about 5 - 9 eV and the electron density is 6.0× 10^13 ~ 1.2 × 10^14 m^-3 while the discharge current is in a range of 50 - 120 μA. 展开更多
关键词 Penning discharge ion source hydrogen plasma DIAGNOSIS double probes
在线阅读 下载PDF
Local Measurement of Gas-Liquid Bubbly Flow with a Double-Sensor Probe 被引量:2
2
作者 孙科霞 张鸣远 陈学俊 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2000年第1期33-40,共8页
A double-sensor probe was used to measure local interfacial parameters of a gas-liquid bubbly flow in a horizontal tube. The parameters included void fraction, interfacial concentration, bubble size distribution, bubb... A double-sensor probe was used to measure local interfacial parameters of a gas-liquid bubbly flow in a horizontal tube. The parameters included void fraction, interfacial concentration, bubble size distribution, bubble frequency and bubble interface velocity. The authors paid special attention to the probe design and construction for minimizing measurement errors. Measures were also taken in the design of sensor ends for preventing corrosions in the flow. This is an effort to improve the current double-sensor probe technique to meet the ever-increasing needs to local parameter measurements in gas-liquid two-phase flows. 展开更多
关键词 two-phase bubbly flow double sensor probe signal processing local interfacial parameters
在线阅读 下载PDF
Improved Double-Probe Technique for Spatially Resolved Diagnosis of Dual-Frequency Capacitive Plasmas 被引量:1
3
作者 陆文琪 蒋相站 +6 位作者 刘永新 杨烁 张权治 李小松 徐勇 朱爱民 王友年 《Plasma Science and Technology》 SCIE EI CAS CSCD 2013年第6期511-515,共5页
The conventional double-probe technique was improved with a combination of selfpowering and radio-frequency(RF) choking.RF perturbations in dual-frequency capacitively coupled discharge were effectively eliminated,a... The conventional double-probe technique was improved with a combination of selfpowering and radio-frequency(RF) choking.RF perturbations in dual-frequency capacitively coupled discharge were effectively eliminated,as judged by the disappearance of self-bias on the probes.The improved technique was tested by spatially resolved measurements of the electron temperature and ion density in both the axial and radial directions of a dual-frequency capacitive plasma.The measured data in the axial direction were compared with simulation results,and they were excellently consistent with each other.The measured radial distributions of the ion density and electron temperature were influenced significantly by the lower frequency(LF) power.It was shown that superposition of the lower frequency to the higher frequency(HF) power shifted the maximum ion density from the radial center to the edge region,while the trend for the electron temperature profile was the opposite.The changing feature of the ion density distribution is qualitatively consistent with that of the optical emission intensity reported. 展开更多
关键词 dual-frequency capacitive plasma double probe plasma diagnosis
在线阅读 下载PDF
A double toroidal analyzer for scanning probe electron energy spectrometer 被引量:1
4
作者 徐春凯 张盼科 +1 位作者 郦盟 陈向军 《Chinese Physics B》 SCIE EI CAS CSCD 2014年第7期183-187,共5页
An ultra-high vacuum (UHV) compatible electron spectrometer employing a double toroidal analyzer has been de- veloped. It is designed to be combined with a custom-made scanning tunneling microscope (STM) to study ... An ultra-high vacuum (UHV) compatible electron spectrometer employing a double toroidal analyzer has been de- veloped. It is designed to be combined with a custom-made scanning tunneling microscope (STM) to study the spatially localized electron energy spectrum on a surface. A tip-sample system composed of a piezo-driven field-emission tungsten tip and a sample of highly ordered pyrolytic graphite (HOPG) is employed to test the performance of the spectrometer. Two-dimensional images of the energy-resolved and angle-dispersed electrons backscattered from the surface of HOPG are obtained, the performance is optimized and the spectrometer is calibrated. A complete electron energy loss spectrum covering the elastic peak to the secondary electron peaks for the HOPG surface, acquired at a tip voltage of -140 V and a sample current of 0.5 pA, is presented, demonstrating the viability of the spectrometer. 展开更多
关键词 double toroidal analyzer scanning probe electron energy spectroscopy electron energy loss spec-troscopy secondary electron emission spectroscopy
原文传递
Phase-dependent double optomechanically induced transparency in a hybrid optomechanical cavity system with coherently mechanical driving
5
作者 Shi-Chao Wu Li-Guo Qin +1 位作者 Jian Lu Zhong-Yang Wang 《Chinese Physics B》 SCIE EI CAS CSCD 2019年第7期233-242,共10页
We propose a scheme that can generate tunable double optomechanically induced transparency in a hybrid optomechanical cavity system.In this system, the mechanical resonator of the optomechanical cavity is coupled with... We propose a scheme that can generate tunable double optomechanically induced transparency in a hybrid optomechanical cavity system.In this system, the mechanical resonator of the optomechanical cavity is coupled with an additional mechanical resonator and the additional mechanical resonator can be driven by a weak external coherently mechanical driving field.We show that both the intensity and the phase of the external mechanical driving field can control the propagation of the probe field, including changing the transmission spectrum from double windows to a single-window.Our study also provides an effective way to generate intensity-controllable, narrow-bandwidth transmission spectra, with the probe field modulated from excessive opacity to remarkable amplification. 展开更多
关键词 double optomechanically induced TRANSPARENCY HYBRID optomechanical CAVITY SYSTEM pump– probe spectroscopy MECHANICAL driving
原文传递
Comparison of double layer in argon helicon plasma and magnetized DC discharge plasma
6
作者 Yueqing WANG Ruilin CUI +4 位作者 Ruoyu HAN Feng HE Tianliang ZHANG Jinsong MIAO Jiting OUYANG 《Plasma Science and Technology》 SCIE EI CAS CSCD 2022年第3期114-122,共9页
We present in this paper the comparison of an electric double layer(DL)in argon helicon plasma and magnetized direct current(DC)discharge plasma.DL in high-density argon helicon plasma of 13.56 MHz RF discharge was in... We present in this paper the comparison of an electric double layer(DL)in argon helicon plasma and magnetized direct current(DC)discharge plasma.DL in high-density argon helicon plasma of 13.56 MHz RF discharge was investigated experimentally by a floating electrostatic probe and local optical emission spectroscopy(LOES).The DL characteristics at different operating parameters,including RF power(300-1500 W),tube diameter(8-60 mm),and external magnetic field(0-300 G),were measured.For comparison,DL in magnetized plasma channel of a DC discharge under different conditions was also measured experimentally.The results show that in both cases,DL appears in a divergent magnetic field where the magnetic field gradient is the largest and when the plasma density is sufficiently high.DL strength(or potential drop of DL)increases with the magnetic field in two different structures.It is suggested that the electric DL should be a common phenomenon in dense plasma under a gradient external magnetic field.DL in magnetized plasmas can be controlled properly by magnetic field structure and discharge mode(hence the plasma density). 展开更多
关键词 helicon plasma magnetized plasma double layer diverging magnetic field electrostatic probe OES
在线阅读 下载PDF
Transient infiltration tests in pyroclastic soils with double porosity
7
作者 Ciro SEPE Domenico CALCATERRA +6 位作者 Emilia DAMIANO Diego DI MARTIRE Roberto GRECO Lucia PAPPALARDO Massimo RAMONDINI Enza VITALE Giacomo RUSSO 《Journal of Mountain Science》 SCIE CSCD 2023年第11期3327-3342,共16页
Fallout volcanic deposits of SommaVesuvius(Campania,southern Italy),characterized by the presence of layers with contrasting textural and hydraulic properties,are frequently affected by shallow landslides during rainw... Fallout volcanic deposits of SommaVesuvius(Campania,southern Italy),characterized by the presence of layers with contrasting textural and hydraulic properties,are frequently affected by shallow landslides during rainwater infiltration.The soils of the stratigraphic sequence present intraparticle pores,originated by the gases escaped during magma decompression in the volcanic conduit,thus are characterized by double porosity(i.e.,intraparticle and interparticle pores),which is expected to affect their hydraulic behaviour,and to play a key role in rainwater infiltration through layered deposits.To understand the effect of double porosity on the hydraulic behaviour of the involved soils,controlled experiments have been carried out in an infiltration column.The experimental apparatus is provided with newly designed non-invasive Time Domain Reflectometry(TDR)probes,not buried in the investigated soil layers so as to minimize disturbance to the flow,allowing water content measurement during vertical flow processes.Specifically,transient flow experiments are carried out through reconstituted specimens of black scoriae and grey pumices,both loose pyroclastic granular soils from fallout deposits of Somma-Vesuvius,featuring double porosity with different pore size distributions,that were estimated by X-ray tomography and Mercury Intrusion Porosimetry.The experimental results highlight the effects of the double porosity and clearly indicate the different behaviour of the two soils during wetting and drying processes,mainly related to the different dimensions of intraparticle pores. 展开更多
关键词 double porosity soil Non-invasive TDR probes Vesiculated soil particles Pyroclastic soils X-ray tomography Mercury intrusion porosimetry
原文传递
双链DNA-铜纳米簇荧光适体探针用于微囊藻毒素-LR传感检测研究 被引量:1
8
作者 罗焰 张慧莲 +5 位作者 罗平馨 张艳丽 高连训 王红斌 杨文荣 庞鹏飞 《云南大学学报(自然科学版)》 北大核心 2025年第3期565-572,共8页
采用DNA模板法合成双链DNA-铜纳米簇(dsDNA-CuNCs)荧光适体探针,用于微囊藻毒素-LR(MC-LR)高灵敏传感检测.微囊藻毒素-LR适体链(aptamer)与其互补链c DNA通过杂交反应形成dsDNA,以dsDNA为模板,利用抗坏血酸还原铜离子(Cu^(2+)),制备得... 采用DNA模板法合成双链DNA-铜纳米簇(dsDNA-CuNCs)荧光适体探针,用于微囊藻毒素-LR(MC-LR)高灵敏传感检测.微囊藻毒素-LR适体链(aptamer)与其互补链c DNA通过杂交反应形成dsDNA,以dsDNA为模板,利用抗坏血酸还原铜离子(Cu^(2+)),制备得到具有粉红色荧光的dsDNA-CuNCs适体探针.存在目标物MC-LR时,由于MC-LR与dsDNA-CuNCs中aptamer之间高特异性结合,导致dsDNA解体,CuNCs释放至溶液,dsDNA-CuNCs探针荧光淬灭.此外,c DNA采用花菁类荧光染料标记(Cy5-cDNA),其可与释放的CuNCs相互作用,导致Cy5-cDNA荧光同时淬灭.基于此构建了一种双重荧光淬灭体系,二者对MC-LR检测线性范围为10 ng/L~500μg/L,检出限为3.3 ng/L (S/N=3).该适体探针具有制备简单、双重荧光检测特点,可用于实际水样中MC-LR的检测分析. 展开更多
关键词 微囊藻毒素-LR 双链DNA-铜纳米簇 DNA模板法 荧光适体探针
在线阅读 下载PDF
黄土含水率DPHP-FBG传感器研究
9
作者 祝越 吴静红 +2 位作者 郭君仪 孙梦雅 贾立翔 《计量学报》 北大核心 2025年第3期442-449,共8页
基于光纤布拉格光栅(fiber Bragg grating,FBG)的双探针热脉冲方法(double probe heat pulse,DPHP),研发了DPHP-FBG传感器,用于延安黄土含水率的测定,并分析不同加热时间和不同加热功率对含水率测量结果的影响。研究表明:DPHP-FBG方法... 基于光纤布拉格光栅(fiber Bragg grating,FBG)的双探针热脉冲方法(double probe heat pulse,DPHP),研发了DPHP-FBG传感器,用于延安黄土含水率的测定,并分析不同加热时间和不同加热功率对含水率测量结果的影响。研究表明:DPHP-FBG方法可实现非饱和黄土含水率的精确测量,尤其适用于低含水率土体监测。恒定加热功率下,加热时间控制在16 s内时,测量误差随着加热时间的增加而减小。足够加热时间下,加热功率的影响较小,无需采用过高的加热功率,在加热时间为20 s时,30.15 W/m的加热功率即可实现高精度含水率的测量。DPHPFBG法能够实现土壤含水率的远程、实时、精细化监测,为原位土体水分场、土壤水分蒸发和冻融的研究提供了一种新的监测手段。 展开更多
关键词 体积含水率 水分传感器 双探针热脉冲 光纤布拉格光栅法 延安黄土 误差分析
在线阅读 下载PDF
国产智能火检的自诊断与可靠性提升策略
10
作者 刘星明 《电力系统装备》 2025年第10期151-153,共3页
1000 MW双切圆锅炉作为1000 MW级火力发电机组的核心设备,具有结构复杂的特点,其燃烧稳定性和机组安全运行密切关联。文章以1000 MW双切圆锅炉为研究对象,聚焦国产智能火检的自诊断与可靠性提升问题,分析1000 MW双切圆锅炉的设备特征,... 1000 MW双切圆锅炉作为1000 MW级火力发电机组的核心设备,具有结构复杂的特点,其燃烧稳定性和机组安全运行密切关联。文章以1000 MW双切圆锅炉为研究对象,聚焦国产智能火检的自诊断与可靠性提升问题,分析1000 MW双切圆锅炉的设备特征,探讨国产智能火检在该锅炉应用中的诊断要点,提出具体的自诊断与可靠性提升策略,为国产智能火检在大型火力发电锅炉中的稳定应用提供参考,保障电力系统的安全高效运行。 展开更多
关键词 国产智能火检 双切圆锅炉 自诊断 处理仪 防爆型探头放大器
在线阅读 下载PDF
承压设备裙座角焊缝超声波检测工艺探索——双横波斜探头串列式扫查工艺
11
作者 刘智 《石油化工建设》 2025年第9期99-101,共3页
超声检测具有穿透能力强、检测过程对人体和环境无害、能够对缺陷进行定位等优点,被广泛应用于设备制造过程中的检测。但其对形状复杂或不规则的工件检测有一定的困难,例如承压设备裙座角焊缝由于其特殊焊接接头形式(搭接接头),及其可... 超声检测具有穿透能力强、检测过程对人体和环境无害、能够对缺陷进行定位等优点,被广泛应用于设备制造过程中的检测。但其对形状复杂或不规则的工件检测有一定的困难,例如承压设备裙座角焊缝由于其特殊焊接接头形式(搭接接头),及其可能的缺陷形状、取向、位置,使常规超声检测工艺难以有效实施。新的检测工艺增加了双横波斜探头串列式扫查方式,即一个发射声波,一个接收声波,声波通过被检工件底面发射后,在经过缺陷面的反射被接收探头接收,从而达到判断工件是否存在缺陷的目的。同时,采用厚度区域上的分层检测以提升检测效率。经实际操作验证,能够有效地检测设备裙座角焊缝的各类缺陷检测。 展开更多
关键词 超声检测工艺 承压设备裙座角焊缝 双横波斜探头串列式扫查 超声分层扫查
在线阅读 下载PDF
Monopole Antenna Probe for Density Measurements in Cold Plasmas
12
作者 王慧慧 李弘 +5 位作者 王雨后 李斌 尤玮 陈志鹏 谢锦林 刘万东 《Plasma Science and Technology》 SCIE EI CAS CSCD 2011年第2期197-200,共4页
A simple diagnostic tool for density measurements in plasma with a certain spatial resolution is proposed in this paper. It uses the emission characteristics of monopole antenna to determine the dielectic property of ... A simple diagnostic tool for density measurements in plasma with a certain spatial resolution is proposed in this paper. It uses the emission characteristics of monopole antenna to determine the dielectic property of plasma c = 1 - fp^2/f^2, with the fp electron plasma frequency related to plasma density. We immersed a inonopole antenna probe into plasma and introduced a microwave signal via a network analyzer. When the emitted power is maximized, the reflected power is minimized and there occurs a resonance. Since can be derived from the resonant frequency, this is actually a method to measure the absolute electron density. Validated by a comparison with the amended Langmuir double-probe method, the monopole antenna probe is valuable. In addition, it is free from the difficulties, such as fluctuation in plasma potential. 展开更多
关键词 electron density monopole antenna probe Langmuir double probe relativepermittivity resonance frequency
在线阅读 下载PDF
Measurement of Ion Parameters by Ion Sensitive Probe in ECR Plasma
13
作者 谭必松 马志斌 +3 位作者 沈武林 吴振辉 曹宏 汪建华 《Plasma Science and Technology》 SCIE EI CAS CSCD 2011年第1期68-72,共5页
Ion parameters in electron cyclotron resonance (ECR) microwave plasma were measured by ion sensitive probe and were compared with the electron parameters obtained by double Langmuir probe. The effects of gas pressur... Ion parameters in electron cyclotron resonance (ECR) microwave plasma were measured by ion sensitive probe and were compared with the electron parameters obtained by double Langmuir probe. The effects of gas pressure and microwave power on the ion temperature and density were analyzed. The spatial distribution of the ion parameters was also investigated by the ion sensitive probes with a tunable radial depth installed on different probe windows along the chamber axis. Results showed that the ion density measured by the ion sensitive probe was in good agreement with the electron density measured by the double Langmuir probe. The influ- ence of gas pressure on the ion parameters was stronger than that of microwave power. With the increase in working pressure, the ion temperature decreased monotonously with a decreasing rate larger than that at higher pressure. The ion density first increased to a peak (42.3~ 101~ cm-3) at 1 Pa and then decreased. The ion temperature and density increased little with the increase in the microwave power from 400 W to 800 W, The plasma far away from the resonant point is found to be radially uniform. 展开更多
关键词 ion sensitive probe double Langmuir probe ECR plasma ion parameter vspatial distribution
在线阅读 下载PDF
Interaction of host-vip complexes of cucurbit[n]urils with double probe vips 被引量:4
14
作者 MA Peihua1, DONG Jun1, XIANG Shuangchun1, XUE Saifeng1, ZHU Qianjiang1, TAO Zhu1, ZHANG Jianxin2 & ZHOU Xin2 1. Institute of Applied Chemistry, Guizhou University, Guiyang, 550025, China 2. The Key Laboratory of Chemistry for Natural Products of Guizhou Province, Guiyang 550002, China 《Science China Chemistry》 SCIE EI CAS 2004年第4期301-310,共10页
Three vips with two moiety probes for different Cucurbit[n = 6—8]urils have been synthesized. They are N-(2-methylenethiophen)-adamataneamine, N-(2-methylene pyrrole)- adamataneamine and N-(2-methylenefurfuran)-ada... Three vips with two moiety probes for different Cucurbit[n = 6—8]urils have been synthesized. They are N-(2-methylenethiophen)-adamataneamine, N-(2-methylene pyrrole)- adamataneamine and N-(2-methylenefurfuran)-adamataneamine. The probes are methyle-nepyridyl typically for Q[6] and adamataneamine typically for Q[7]. The host-vip complexes of Cucurbit[n = 6—8]urils with these vips have been investigated by using NMR techniques and ESMS method. Also, thermoanalysis has been used for exploring relationship of enthalpy and stability of the host-vip complexes. 展开更多
关键词 CUCURBITURILS double probe vips 1H NMR technique ESMS method THERMOANALYSIS host-vip interaction
原文传递
基于磁导率无损检测的双U型探头仿真优化研究
15
作者 邓文洁 任尚坤 《焊管》 2024年第3期41-46,57,共7页
基于磁导率无损检测原理,设计了一种双U型检测探头。以20钢试件为研究对象,通过模拟仿真分析了双U型探头在检测过程中的关键影响参数与检测灵敏度的关系,对关键影响参数进行了优化选取,又通过试验研究了拉应力对检测灵敏度的影响。结果... 基于磁导率无损检测原理,设计了一种双U型检测探头。以20钢试件为研究对象,通过模拟仿真分析了双U型探头在检测过程中的关键影响参数与检测灵敏度的关系,对关键影响参数进行了优化选取,又通过试验研究了拉应力对检测灵敏度的影响。结果表明,检测灵敏度随着激励电压幅值的升高而增大,随着激励频率的提高先增大后趋于稳定,随着激励线圈匝数的增加而下降,随着拉应力的增大而减小,双U型探头相比于传统U型探头具有更广泛的分析检测能力。该仿真研究为后续探头的选取制作提供了设计理念和理论依据。 展开更多
关键词 磁导率无损检测 双U型探头 检测灵敏度 应力集中
在线阅读 下载PDF
双发射荧光碳点的简易合成及其在pH检测中的应用 被引量:1
16
作者 杨丹 刘德鸿 +2 位作者 丁雪晴 张星 郝艳玲 《价值工程》 2024年第31期111-114,共4页
以绿茶茶叶渣为碳源,通过简单易操作的微波法制备了水溶液中呈现双发射的茶叶基碳点(T-CDs),两发光峰分别位于520nm和678nm附近,绿光520nm左右的发射峰随激发波长的增大而红移,红光发射峰随激发波长的改变不移动。研究发现,双峰对pH值... 以绿茶茶叶渣为碳源,通过简单易操作的微波法制备了水溶液中呈现双发射的茶叶基碳点(T-CDs),两发光峰分别位于520nm和678nm附近,绿光520nm左右的发射峰随激发波长的增大而红移,红光发射峰随激发波长的改变不移动。研究发现,双峰对pH值的敏感程度不同,随着缓冲溶液pH值的增大,该碳点的绿色荧光逐渐增强,而红色荧光相对减弱。因此,利用T-CDs的双发射峰的强度比作为pH的测定信号构建了比率型pH荧光探针,结果表明,该荧光探针不仅亲水性好、响应快、检测范围宽(pH值4-10),而且可以实现裸眼可见的比色检测,在pH值检测领域具有广阔的应用前景。 展开更多
关键词 茶叶基碳点 双发射 比率型荧光探针
在线阅读 下载PDF
大跨距轴探管挠度补偿技术研究
17
作者 庞钦 范长海 +1 位作者 周洪 李增军 《机械设计》 CSCD 北大核心 2024年第10期108-114,共7页
轴探管是气动设备流场校测的重要装置,针对其自重引起的挠曲变形问题,采用“内骨架预变形挠度补偿+微调节机构补偿”方法,对长度17.3 m的一段轴探管进行挠度补偿技术研究。通过双楔形垫片实现内骨架预变形挠度补偿,对轴探管进行仿真分析... 轴探管是气动设备流场校测的重要装置,针对其自重引起的挠曲变形问题,采用“内骨架预变形挠度补偿+微调节机构补偿”方法,对长度17.3 m的一段轴探管进行挠度补偿技术研究。通过双楔形垫片实现内骨架预变形挠度补偿,对轴探管进行仿真分析,计算每组楔形垫片的调节角度,根据计算的调节角度得出垫片的旋转角度,用于指导内骨架的预变形挠度补偿和装配,采用激光跟踪仪测得轴探管直线度为1.81 mm/m,达到直线度优于2 mm/m的指标要求。测试结果表明:该挠度补偿方法是可行性的,其研究成果对于大跨距轴探管设计提供理论指导。 展开更多
关键词 轴探管 挠度补偿 双楔形垫片 内骨架
原文传递
利用超快光谱与可见/红外双激发荧光对长寿命振动热基态的直接观察
18
作者 喻琪锐 李鑫茂 +3 位作者 沈成桢 于志浩 关键鑫 郑俊荣 《Chinese Journal of Chemical Physics》 SCIE EI CAS CSCD 2024年第2期411-419,I0070-I0087,I0105,共28页
在超快红外光谱测量中观察到的纳秒级弛豫诱导漂白信号被广泛认为是由于红外激发热化产生的局部热效应。本文结合超快红外泵浦/探测、二维红外光谱、可见泵浦/红外探测和超快可见/红外双共振荧光实验,发现甲醇溶液中荧光素二价阴离子的... 在超快红外光谱测量中观察到的纳秒级弛豫诱导漂白信号被广泛认为是由于红外激发热化产生的局部热效应。本文结合超快红外泵浦/探测、二维红外光谱、可见泵浦/红外探测和超快可见/红外双共振荧光实验,发现甲醇溶液中荧光素二价阴离子的振动热基态寿命出人意料的长,能达到纳秒级.结果表明,在非线性红外实验中观察到的长寿命漂白信号在最初的几纳秒内一定存在这些热基态的重要贡献.类似的机制很可能也适用于其他分子系统,热基态的存在时间能比以往的预期长得多,有可能被应用于调控化学反应. 展开更多
关键词 超快光谱 荧光 可见红外双激发 长寿命热基态 二维红 外光谱 泵浦-探测
在线阅读 下载PDF
Ka频段160 W固态功率放大器的研制
19
作者 黄薛龙 《舰船电子工程》 2024年第4期194-198,共5页
针对Ka频段固态功率放大器合成芯片数量多及产品体积大等问题,介绍了一种八路合成的Ka频段160 W固态功率放大器。功放采用波导-微带双探针和基于微带-魔T的波导功率分配/合成器,将8个GaN功放芯片加以合成,最终实现在27.0 GHz~31.0 GHz... 针对Ka频段固态功率放大器合成芯片数量多及产品体积大等问题,介绍了一种八路合成的Ka频段160 W固态功率放大器。功放采用波导-微带双探针和基于微带-魔T的波导功率分配/合成器,将8个GaN功放芯片加以合成,最终实现在27.0 GHz~31.0 GHz工作频带内,连续波输出160 W以上的功率信号,利用模拟预失真器使整机三阶互调指标优于-31 dBc,指标优良。功放输出波导采用标准WR-28接口,具有完善的监控和保护措施,可靠性高,适用于卫星通信等发射系统。 展开更多
关键词 KA频段 波导-微带双探针 微带-魔T合成 模拟预失真 可靠性高
在线阅读 下载PDF
PCR方法检测食品中的转基因成分35S和NOS的研究 被引量:14
20
作者 刘光明 苏文金 +2 位作者 栾国彦 宋思扬 梁基选 《食品科学》 EI CAS CSCD 北大核心 2002年第5期94-99,共6页
根据转基因农作物中最常用的花椰菜叶病毒启动子(CaMV35S)和根癌农杆菌终止子(NOS)的序列,设计并合成了两对不同的引物和相对应的两种荧光双链探针(FDCP),分别建立了常规PCR、应用FDCP的新型实时荧光PCR检测转基因成分35S启动子和NOS终... 根据转基因农作物中最常用的花椰菜叶病毒启动子(CaMV35S)和根癌农杆菌终止子(NOS)的序列,设计并合成了两对不同的引物和相对应的两种荧光双链探针(FDCP),分别建立了常规PCR、应用FDCP的新型实时荧光PCR检测转基因成分35S启动子和NOS终止子的方法。利用该套方法对冷冻马铃薯条、大豆、冷冻玉米棒、甜椒、番茄等实物样品进行了检测,发现11份样品中有5份检出35S启动子、NOS终止子,6份样品结果为阴性。结果表明我们建立的两种PCR方法均能有效检测出35S和NOS片段,其中常规PCR方法具有灵敏度高、特异性好的特点;应用FDCP的新型实时荧光PCR方法则更为简便、快速、准确,有很好的应用前景和研究价值。 展开更多
关键词 PCR方法 检测 食品 转基因成分 35S NOS 荧光双链探针
在线阅读 下载PDF
上一页 1 2 12 下一页 到第
使用帮助 返回顶部