Graph Attention Network Based Deep Reinforcement Learning for Voltage/var Control of Topologically Variable Power System
1
作者 Xiaofei Liu Pei Zhang +3 位作者 Hua Xie Xuegang Lu Xiangyu Wu Zhao Liu 《Journal of Modern Power Systems and Clean Energy》 2025年第1期215-227,共13页
The high proportion of renewable energy integration and the dynamic changes in grid topology necessitate the enhancement of voltage/var control(VVC)to manage voltage fluctuations more rapidly.Traditional model-based c... The high proportion of renewable energy integration and the dynamic changes in grid topology necessitate the enhancement of voltage/var control(VVC)to manage voltage fluctuations more rapidly.Traditional model-based control algorithms are becoming increasingly incompetent for VVC due to their high model dependence and slow online computation speed.To alleviate these issues,this paper introduces a graph attention network(GAT)based deep reinforcement learning for VVC of topologically variable power system.Firstly,combining the physical information of the actual power grid,a physics-informed GAT is proposed and embedded into the proximal policy optimization(PPO)algorithm.The GAT-PPO algorithm can capture topological and spatial correlations among the node features to tackle topology changes.To address the slow training,the Relief F-S algorithm identifies critical state variables,significantly reducing the dimensionality of state space.Then,the training samples retained in the experience buffer are designed to mitigate the sparse reward issue.Finally,the validation on the modified IEEE 39-bus system and an actual power grid demonstrates superior performance of the proposed algorithm compared with state-of-the-art algorithms,including PPO algorithm and twin delayed deep deterministic policy gradient(TD3)algorithm.The proposed algorithm exhibits enhanced convergence during training,faster solution speed,and improved VVC performance,even in scenarios involving grid topology changes and increased renewable energy integration.Meanwhile,in the adopted cases,the network loss is reduced by 6.9%,10.8%,and 7.7%,respectively,demonstrating favorable economic outcomes. 展开更多
关键词 voltage/var control grid topology renewable energy graph attention network deep reinforcement learning
原文传递
Excellent ultrahigh voltage performance of a layered cathode supported by a sacrificial layer arising from deep selenium modification
2
作者 Yan Zhu Jian Fu +7 位作者 Jingwei Hu Xinxiong Zeng Zhengjie Huang Bing Zhang Xiaocheng Li Wei Nie Ning Wang Xihao Chen 《Journal of Energy Chemistry》 2026年第1期852-860,I0019,共10页
The implementation of multifunctional application scenarios for mobile terminal devices has increased the energy density requirements of batteries.Increasing the charging voltage can rapidly increase the specific capa... The implementation of multifunctional application scenarios for mobile terminal devices has increased the energy density requirements of batteries.Increasing the charging voltage can rapidly increase the specific capacity of layered transition metal oxides;however,it also exacerbates the release of lattice oxygen and the contraction of the unit cell.Ternary materials are designed in a secondary particle state to meet the requirements of power battery applications.Therefore,to create ternary materials that can operate under ultrahigh voltages,attention should be given to both surface modification and particle integrity maintenance.By utilizing elemental selenium(Se)with a low melting point,easy sublimation,and multiple variable valence states,deep grain boundary modification was implemented inside the particles.The performance of the cathode material was evaluated through pouch cells,and the improvement mechanism was explored through molecular dynamics simulation calculations.Under the protection of a three-dimensional Se-rich modified layer,LiNi_(1/3)Co_(1/3)Mn_(1/3)O_(2)achieved stable operation at ultrahigh voltages(4.6 V vs.Li/Li^(+));a sacrificial protection mechanism based on the chronic decomposition of the Se-rich layer was proposed to explain the efficacy of Se modification in stabilizing ternary materials.This deep grain boundary modification based on elemental Se provides a new solution for the ultrahigh-voltage operation of transition metal oxides and provides a scientific basis and technical support for solving the interface contact problem of all-solid-state batteries. 展开更多
关键词 Ternary cathode materials Ultrahigh voltage SELENIUM Deep modification
在线阅读 下载PDF
Characterization of the susceptibility of ore particles to breakdown in high voltage pulse breakage and the influencing factors
3
作者 Rui Sun Yang Hong +5 位作者 Daqian Wang Liang Si Jianguo Yang Wei Huang Liefeng Huang Weiran Zuo 《International Journal of Mining Science and Technology》 2026年第1期113-124,共12页
The susceptibility of ore particles to electrical breakdown plays a critical role for high voltage pulse(HVP)breakage,yet its quantitative characterization still lacks deep understanding.Two indicators,namely breakdow... The susceptibility of ore particles to electrical breakdown plays a critical role for high voltage pulse(HVP)breakage,yet its quantitative characterization still lacks deep understanding.Two indicators,namely breakdown delay time(T_(d))and breakdown strength(E_(b))were compared,based on analysis on the two breakdown modes namely wavefront mode and post-wave mode.It was found that T_(d) is more suitable to characterize the susceptibility of ore particles to electrical breakdown in HVP breakage than E_(b).A probabilistic model based on the Weibull distribution is developed to describe the relation of breakdown probability to T_(d).Regression analyses were conducted to investigate how operating parameters and particle properties influence Td and size reduction degree of ore particles in HVP breakage.The regressed models demonstrate potential capability to predict metallic minerals content and HVP breakage degree based on operating parameters and particle properties. 展开更多
关键词 Electrical breakdown High voltage pulse breakage SUSCEPTIBILITY Breakdown delay time
在线阅读 下载PDF
Fault Identification in Renewable Energy Transmission Lines Using Wavelet Packet Decomposition and Voltage Waveform Analysis
4
作者 Huajie Zhang Xiaopeng Li +2 位作者 Hanlin Xiao Lifeng Xing Wenyue Zhou 《Energy Engineering》 2026年第3期434-458,共25页
The integration of a high proportion of renewable energy introduces significant challenges for the adaptability of traditional fault nature identification methods.To address these challenges,this paper presents a nove... The integration of a high proportion of renewable energy introduces significant challenges for the adaptability of traditional fault nature identification methods.To address these challenges,this paper presents a novel fault nature identification method for renewable energy grid-connected interconnection lines,leveraging wavelet packet decomposition and voltage waveform time-frequency morphology comparison algorithms.First,the paper investigates the harmonic injection mechanism during non-full-phase operation following fault isolation in photovoltaic renewable energy systems,and examines the voltage characteristics of faulted phases in renewable energy scenarios.The analysis reveals that substantial differences exist in both the time and frequency domains of phase voltages before and after the extinction of transient faults,whereas permanent faults do not exhibit such variations.Building on this observation,the paper proposes a voltage time-frequency feature extraction method based on wavelet packet decomposition,wherein low-frequency waveform components are selected to characterize fault features.Subsequently,a fault nature identification method is introduced,based on a voltage waveform time-frequency morphology comparison.By employing a windowing technique to quantify waveform differences before and after arc extinction,this method effectively distinguishes between permanent and transient faults and accurately determines the arc extinction time.Finally,a 220 kV renewable energy grid connection line model is developed using PSCAD for verification.The results demonstrate that the proposed method is highly adaptable across various fault locations,transition resistances,and renewable energy control strategies,and can reliably identify fault nature in renewable energy grid connection scenarios. 展开更多
关键词 New energy fault nature identification arc extinguishing time shunt reactors variation mode decomposition port voltage
在线阅读 下载PDF
Battery SOH enhanced solution:Voltage reconstruction and image recognition response to loss of data scenarios
5
作者 Xinghua Liu Linxiang Zhou +4 位作者 Jiaqiang Tian Longxing Wu Zhongbao Wei Hany M.Hasanien Peng Wang 《Journal of Energy Chemistry》 2026年第1期155-169,I0005,共16页
Accurate estimation of battery health status plays a crucial role in battery management systems.However,the lack of operational data still affects the accuracy of battery state of health(SOH)estimation.For this reason... Accurate estimation of battery health status plays a crucial role in battery management systems.However,the lack of operational data still affects the accuracy of battery state of health(SOH)estimation.For this reason,a SOH estimation method is proposed based on charging data reconstruction combined with image processing.The charging voltage data is used to train the least squares generative adversarial network(LSGAN),which is validated under different levels of missing data.From a visual perspective,the Gram angle field method is applied to convert one-dimensional time series data into image data.This method fully preserves the time series characteristics and nonlinear evolution patterns,which avoids the difficulties and limited expressive power associated with manual feature extraction.At the same time,the Swin Transformer model is introduced to extract global structures and local details from images,enabling better capture of sequence change trends.Combined with the long short-term memory network(LSTM),this enables accurate estimation of battery SOH.Two different types of batteries are used to validate the test.The experimental results show that the proposed method has good estimation accuracy under different training proportions. 展开更多
关键词 State of health voltage data reconstruction Least squares generative adversarial NETWORK Gramicci angle field Swin Transformer-LSTM network
在线阅读 下载PDF
Asymmetric Voltage Vector-based Initial Rotor Position Detection in Four-switch Inverter Fed BLDC Motors
6
作者 Xinmin Li Kun Liu +2 位作者 Lu Zhou Tingna Shi Wei Chen 《CES Transactions on Electrical Machines and Systems》 2026年第1期77-86,共10页
In position-sensorless brushless direct current(DC)motors(BLDCMs)fed by a four-switch three-phase(FSTP)inverter,only two phases are fully controlled,while the remaining phase is tied to the midpoint of the split DC-li... In position-sensorless brushless direct current(DC)motors(BLDCMs)fed by a four-switch three-phase(FSTP)inverter,only two phases are fully controlled,while the remaining phase is tied to the midpoint of the split DC-link capacitors.The voltage pulses required by inductance-based initial position detection can cause unequal discharge of the series capacitors,shifting the neutral-point voltage away from half of DC-link voltage(U_(dc)/2).This neutral-point drift breaks the spatial symmetry of the inverter voltage vectors,so the 360°electrical period can no longer be evenly partitioned into six sectors during initial rotor position detection.To address this issue,this paper proposes a detection-pulse injection sequence that explicitly accounts for the asymmetric voltage vectors of the FSTP inverter.With the proposed sequence,the initial rotor position can be identified within a 30°electrical sector.The method requires no additional voltage or current sensors,and experimental results confirm its feasibility. 展开更多
关键词 Brushless direct current(DC)motor(BLDCM) Four-switch three-phase(FSTP)inverter Asymmetric voltage vector Initial position detection
在线阅读 下载PDF
A Low Common-Mode Voltage Virtual Space Vector Modulation of Three-Level Converters for Doubly-Fed Variable-Speed Pumped Storage Systems
7
作者 Ziqiang Man Lei Zhao +6 位作者 Zheng Tao Shiming Cheng Wei Yan Gaoyue Zhong Yu Lu Wenming Zhang Li Zhang 《Energy Engineering》 2025年第9期3555-3572,共18页
With the rapid integration of renewable energy sources,modern power systems are increasingly challenged by heightened volatility and uncertainty.Doubly-fed variable-speed pumped storage units(DFVS-PSUs)have emerged as... With the rapid integration of renewable energy sources,modern power systems are increasingly challenged by heightened volatility and uncertainty.Doubly-fed variable-speed pumped storage units(DFVS-PSUs)have emerged as promising technologies for mitigating grid oscillations and enhancing system flexibility.However,the excitation converters in DFVS-PSUs are prone to significant issues such as elevated common-mode voltage(CMV)and neutral-point voltage(NPV)fluctuations,which can lead to electromagnetic interference and degrade transient performance.To address these challenges,an optimized virtual space vector pulse width modulation(OVSVPWM)strategy is proposed,aiming to suppress CMV and NPV simultaneously through coordinated multi-objective control.Specifically,a dynamic feedback mechanism is introduced to adjust the balancing factor of basic vectors in the synthesized virtual small vector in real-time,achieving autonomous balancing of the NPV.To address the excessive switching actions introduced by the OVSVPWM strategy,a phase duty ratio-based sequence reconstruction method is adopted,which reduces the total number of switching actions to half of the original.A zero-level buffering scheme is employed to reconstruct the single-phase voltage-level output sequence,achieving peak CMV suppression down to udc/6.Simulation results demonstrate that the proposed strategy significantly improves electromagnetic compatibility and operational stability while maintaining high power quality. 展开更多
关键词 Doubly-fed variable-speed pumped storage units three-level excitation converter common-mode voltage neutral-point voltage virtual space voltage vector
在线阅读 下载PDF
A Multi-Timescale Characteristics Analysis of the Network Power Response Excited by Voltage with Time-Varying Amplitude and Frequency
8
作者 Jiabing Hu Weizhong Wen +2 位作者 Yingbiao Li Xing Liu Jianbo Guo 《Engineering》 2025年第8期49-61,共13页
The dynamics of network power response play a crucial role in system stability.However,the integration of power electronic equipment leads to amplitude and angular frequency(abbreviated as"frequency")time-va... The dynamics of network power response play a crucial role in system stability.However,the integration of power electronic equipment leads to amplitude and angular frequency(abbreviated as"frequency")time-varying characteristics of the node voltage during dynamic processes.As a result,traditional calcu-lation methods for and characteristics of the power response of the network based on phasor and impe-dance lose their validity.Therefore,this paper undertakes mathematical calculations to reveal the power response of a network under excitation by voltage with time-varying amplitude and frequency(TVAF),relying on the original mathematical relationships and superimposed step response.Then,the multi-timescale characteristics of both the active and reactive power of the network are explored physically.Additionally,this paper reveals a new phenomenon of storing and releasing the active and reactive power of the network.To meet practical engineering requirements,a simplified power expression is presented.Finally,the theoretical analysis is validated through time-domain simulations. 展开更多
关键词 Power response of network voltage with time-varying amplitude and frequency Multi-timescale characteristics Power electronic equipment
在线阅读 下载PDF
绿色金融与能源市场的波动联动研究——基于多尺度TVP-VAR分析
9
作者 刘剑锋 蒋瑞波 《中国证券期货》 2026年第1期16-25,共10页
本文基于WTI原油与中国绿色债券市场的收益率数据,结合GARCH模型、离散小波变换与TVP-VAR频域溢出模型,分析两者在多尺度下的波动联动关系。结果表明,原油市场波动显著高于绿色债券,二者在中期时间尺度内存在一定的联动性,可能反映市场... 本文基于WTI原油与中国绿色债券市场的收益率数据,结合GARCH模型、离散小波变换与TVP-VAR频域溢出模型,分析两者在多尺度下的波动联动关系。结果表明,原油市场波动显著高于绿色债券,二者在中期时间尺度内存在一定的联动性,可能反映市场资金配置或宏观预期调整下的同步反应;而长期因果关系整体不显著,符合原油市场由供需和基本面主导的特征。频域分析显示,中期溢出效应较为活跃,但主要体现为结构性和间接联动。研究揭示了绿色金融市场在特定宏观阶段可能通过非直接渠道对能源市场形成扰动,为理解跨市场联动提供了有益参考。 展开更多
关键词 WTI原油 绿色债券 GARCH模型 TVP-var频域波动溢出模型
在线阅读 下载PDF
Effects of variations of voltage and pH value on the shear strength of soil and durability of different electrodes and piles during electrokinetic phenomenon 被引量:4
10
作者 Fatemeh Sadeghian Soheil Jahandari +2 位作者 Abdolhosein Haddad Haleh Rasekh Jie Li 《Journal of Rock Mechanics and Geotechnical Engineering》 SCIE CSCD 2022年第2期625-636,共12页
Electrokinetic(EK)treatment is an effective method in accelerating the consolidation and improving the geotechnical properties of fine-grained soils.This method stabilizes the soil and increases the bearing capacity o... Electrokinetic(EK)treatment is an effective method in accelerating the consolidation and improving the geotechnical properties of fine-grained soils.This method stabilizes the soil and increases the bearing capacity of piles by improving the soil shear strength.Changing the soil p H,due to the occurrence of chemical reactions of electrolysis in the soil,can increase its shear strength.However,the electrodes used in this method corrode due to the change in the soil p H,which in turn reduces the electrical potential.Electrode corrosion and loss of electrical potential can significantly reduce the efficiency of the EK method.In addition,when using the EK method to increase the bearing capacity of piles,changing the p H can cause corrosion and damage to the piles.One of the most important factors influencing the change in the p H of soil is the voltage applied during the EK process.It was reported that increasing the voltage affects the intensity of chemical reactions and electroosmotic flow and thus increases the efficiency of EK.However,very limited research has been conducted on the effect of voltage on the performance of EK method.In the present study,the effects of three voltages on soil p H and corrosion resistance of four types of electrodes including iron(Ir),stainless steel(St),copper(Co),and aluminium(Al)were studied.In addition,the effects of p H variations on the corrosion rate of three types of piles including steel pile(SP),reinforced cement concrete pile(RCCP),and reinforced lime-cement concrete pile(RLCCP)were investigated.It was observed that increasing the voltage from a specific limit had no effect on the intensity of electrolysis reactions and the soil p H adjacent to the electrodes did not change more than a specific limit.Moreover,increasing the voltage to higher than 35 V(i.e.45 V)did not increase the volume of drained water from the soil,but caused more electric current than the allowable current for Ir,St,and Al electrodes,and the corrosion intensity of these electrodes increased significantly.RCCP reduced the soil p H to 2.4 within 7 d of curing due to severe corrosion(13%corrosion rate).The soil p H values adjacent to RCCP and RLCCP within 28 d of curing reduced to 3.7 and 3.8,respectively,but the two piles were not damaged.In general,the results of this research showed that selecting an optimized voltage had a significant effect on the efficiency of EK,and increasing the voltage did not always lead to increase in the efficiency of EK process. 展开更多
关键词 Electrokinetic(EK) PILE pH variation voltage Electrode Corrosion resistance
在线阅读 下载PDF
Effects of Additive Nd_2O_3 on Varistor Voltage and Microstructure of ZnO Varistor 被引量:1
11
作者 严群 陈家钊 涂铭旌 《Journal of Rare Earths》 SCIE EI CAS CSCD 2003年第S1期142-145,共4页
The influence of additive Nd_2O_3 on varistor voltage and microstructure of ZnO varistor was studied,and its mechanism was proposed from theoretical analysis. The results show that the varistor voltage of ZnO varistor... The influence of additive Nd_2O_3 on varistor voltage and microstructure of ZnO varistor was studied,and its mechanism was proposed from theoretical analysis. The results show that the varistor voltage of ZnO varistor increases with the content of Nd_2O_3 in the range of 0~0.04 (%,mol fraction). However when the content of Nd_2O_3 is more than 0.04 (%,mol fraction),the varistor voltage of ZnO varistor decreases with the content increase. The microstructure analysis indicates that a small amount of new compound with Nd exists at ZnO grain boundary and hinders the movement of grain boundary,which decreases the size of ZnO grain and makes the grain size and distribution homogeneous,as a result,additive (Nd_2O_3) raises the varistor voltage of the varistor greatly. 展开更多
关键词 ZnO varistor Nd_2O_3 varistor voltage MICROSTRUCTURE rare earths
在线阅读 下载PDF
Breakdown voltage model and structure realization of a thin silicon layer with linear variable doping on a silicon on insulator high voltage device with multiple step field plates 被引量:2
12
作者 乔明 庄翔 +4 位作者 吴丽娟 章文通 温恒娟 张波 李肇基 《Chinese Physics B》 SCIE EI CAS CSCD 2012年第10期504-511,共8页
Based on the theoretical and experimental investigation of a thin silicon layer(TSL) with linear variable doping(LVD) and further research on the TSL LVD with a multiple step field plate(MSFP),a breakdown voltag... Based on the theoretical and experimental investigation of a thin silicon layer(TSL) with linear variable doping(LVD) and further research on the TSL LVD with a multiple step field plate(MSFP),a breakdown voltage(BV) model is proposed and experimentally verified in this paper.With the two-dimensional Poisson equation of the silicon on insulator(SOI) device,the lateral electric field in drift region of the thin silicon layer is assumed to be constant.For the SOI device with LVD in the thin silicon layer,the dependence of the BV on impurity concentration under the drain is investigated by an enhanced dielectric layer field(ENDIF),from which the reduced surface field(RESURF) condition is deduced.The drain in the centre of the device has a good self-isolation effect,but the problem of the high voltage interconnection(HVI) line will become serious.The two step field plates including the source field plate and gate field plate can be adopted to shield the HVI adverse effect on the device.Based on this model,the TSL LVD SOI n-channel lateral double-diffused MOSFET(nLDMOS) with MSFP is realized.The experimental breakdown voltage(BV) and specific on-resistance(R on,sp) of the TSL LVD SOI device are 694 V and 21.3 ·mm 2 with a drift region length of 60 μm,buried oxide layer of 3 μm,and silicon layer of 0.15 μm,respectively. 展开更多
关键词 breakdown voltage model enhanced dielectric layer field thin silicon layer linear variable doping multiple step field plates
原文传递
High-voltage MIM-type aluminum electrolytic capacitors 被引量:1
13
作者 Yuan Guo Shixin Wang +5 位作者 Xianfeng Du Xinkuan Zang Zhongshuai Liang Jun Xiong Ruizhi Wang Zhuo Li 《Journal of Energy Chemistry》 2025年第5期79-90,共12页
Metal-insulator-metal aluminium electrolytic capacitors(MIM-AECs)combine high capacity-density and high breakdown field strength of solid AECs with high-frequency responsibility,wide workingtemperature window and wate... Metal-insulator-metal aluminium electrolytic capacitors(MIM-AECs)combine high capacity-density and high breakdown field strength of solid AECs with high-frequency responsibility,wide workingtemperature window and waterproof properties of MIM nanocapacitors.However,interfacial atomic diffusion poses a major obstacle,preventing the high-voltage MIM-AECs exploitation and thereby hampering their potential and advantages in high-power and high-energy-density applications.Here,an innovative high-voltage MIM-AECs were fabricated.The AlPO_(4)buffer layer is formed on AlO(OH)/AAO/Al surface by using H_(3)PO_(4)treatment,then a stable van der Waals(vdW)SnO_(2)/AlPO_(4)/AAO/Al multilayer was constructed via atomic layer deposition(ALD)technology.Due to higher diffusion barrier and lower carrier migration of SnO_(2)/AlPO_(4)/AAO interfaces,Sn atom diffusion is inhibited and carrier acceleration by electric field is weakened,guaranteeing high breakdown field strength of dielectric AAO and avoiding local breakdown risks.Through partial etching to hydrated AlO(OH)by H_(3)PO_(4)treatment,the tunnel was further opened up to facilitate subsequent ALD-SnO_(2)entry,thus obtaining a high SnO_(2)coverage.The SnO_(2)/AlPO_(4)/AAO/Al capacitors show a comprehensive performance in high-voltage(260 V),hightemperature(335℃),high-humidity(100%RH)and high-frequency response(100 k Hz),outperforming commercial solid-state AECs,and high-energy density(8.6μWh/cm^(2)),markedly exceeding previously reported MIM capacitors.The work lays the foundation for next-generation capacitors with highvoltage,high-frequency,high-temperature and high-humidity resistance. 展开更多
关键词 MIM nanocapacitor Electrolytic capacitor Buffer layer Atomic layer deposition High voltage
在线阅读 下载PDF
Attenuating reductive decomposition of fiuorinated electrolytes for high-voltage lithium metal batteries 被引量:1
14
作者 Zhen-Zhen Dong Jin-Hao Zhang +4 位作者 Lin Zhu Xiao-Zhong Fan Zhen-Guo Liu Yi-Bo Yan Long Kong 《Chinese Chemical Letters》 2025年第4期416-419,共4页
Fluoride-based electrolyte exhibits extraordinarily high oxidative stability in high-voltage lithium metal batteries(h-LMBs) due to the inherent low highest occupied molecular orbital(HOMO) of fiuorinated solvents. Ho... Fluoride-based electrolyte exhibits extraordinarily high oxidative stability in high-voltage lithium metal batteries(h-LMBs) due to the inherent low highest occupied molecular orbital(HOMO) of fiuorinated solvents. However, such fascinating properties do not bring long-term cyclability of h-LMBs. One of critical challenges is the interface instability in contacting with the Li metal anode, as fiuorinated solvents are highly susceptible to exceptionally reductive metallic Li attributed to its low lowest unoccupied molecular orbital(LUMO), which leads to significant consumption of the fiuorinated components upon cycling.Herein, attenuating reductive decomposition of fiuorinated electrolytes is proposed to circumvent rapid electrolyte consumption. Specifically, the vinylene carbonate(VC) is selected to tame the reduction decomposition by preferentially forming protective layer on the Li anode. This work, experimentally and computationally, demonstrates the importance of pre-passivation of Li metal anodes at high voltage to attenuate the decomposition of fiuoroethylene carbonate(FEC). It is expected to enrich the understanding of how VC attenuate the reactivity of FEC, thereby extending the cycle life of fiuorinated electrolytes in high-voltage Li-metal batteries. 展开更多
关键词 Li metal batteries Solid electrolyte interphase High voltage Fluorinated electrolyte Electrolyte decomposition
原文传递
Deciphering and overcoming the high-voltage limitations of halide and sulfide-based all-solid-state lithium batteries 被引量:1
15
作者 Xiang Qi Gang Wu +5 位作者 Meng Wu Dabing Li Chao Wang Lei Gao Shichao Zhang Li-Zhen Fan 《Journal of Energy Chemistry》 2025年第4期926-935,共10页
Adopting high-voltage Ni-rich cathodes in halide and sulfide-based all-solid-state lithium batteries(ASSLBs)holds great promise for breaking through the 400 Wh kg^(-1)bottleneck.However,both cell configurations are co... Adopting high-voltage Ni-rich cathodes in halide and sulfide-based all-solid-state lithium batteries(ASSLBs)holds great promise for breaking through the 400 Wh kg^(-1)bottleneck.However,both cell configurations are confronted with intricate interfacial challenges in high-voltage regines(>4.5 V),resulting in inadequate cathode utilization and premature cell degradation.Moreover,contrary to previous studies,coupled with LiNi_(0.85)Co_(0.1)Mn_(0.05)O_(2)cathodes,typical halide(Li_(2)ZrCl_(6))-based cells at 4.5 V feature unlimited interfacial degradation and poor long cycle stability,while typical sulfide(Li_(6)PS_(5)Cl)-based cells feature self-limited interfacial degradation and poor initial cycle stability.Herein,this work addresses the high-voltage limitations of Li_(2)ZrCl_(6)and Li_(6)PS_(5)Cl catholyte-based cells by manipulating electrode mass fraction and tailoring interfacial composition,thereby effectively improving interfacial charge-transfer kinetics and(electro)chemical stability within cathodes.After appropriate interface design,both optimized cells at 4.5 V demonstrate remarkably increased initial discharge capacities(>195 mA h g^(-1)at0.1 C),improved cycle stabilities(>80%after 600 cycles at 0.5 C),and enhanced rate performances(>115 mA h g^(-1)at 1.0 C).This work deepens our understanding of high-voltage applications for halide/sulfide electrolytes and provides generalized interfacial design strategies for advancing high-voltage ASSLBs. 展开更多
关键词 All-solid-state lithium batteries Halide solid electrolytes Sulfide solid electrolytes High voltage Interface design
在线阅读 下载PDF
Smooth switching mechanism-based adaptive integral terminal SMC for PMSM servo system with stator voltage saturation and unknown disturbances 被引量:1
16
作者 Xiangxiang Meng Haisheng Yu +1 位作者 Jie Zhang Qing Yang 《Control Theory and Technology》 2025年第2期294-309,共16页
This article investigates the anti-disturbance and stabilization problems for the nonlinear uncertain permanent magnet synchronous motor(PMSM)with stator voltage saturation and unknown load.A smooth switching mechanis... This article investigates the anti-disturbance and stabilization problems for the nonlinear uncertain permanent magnet synchronous motor(PMSM)with stator voltage saturation and unknown load.A smooth switching mechanism is presented to structure the adaptive integral terminal sliding mode control(SMC)strategy.The control design consists of compensation control and nominal control,which improves the rapidity and accuracy of trajectory tracking.The smooth saturation model based on the error function is applied to approximate the voltage saturation phenomenon.Additionally,to deal with the adverse effects of various unknown disturbances,including model parameter uncertainties and unknown external load disturbances,an improved disturbance observer(DO)is proposed.This observer effectively suppresses the fluctuations caused by fixed gain during the starting period of the system.Finally,the experimental results under different conditions show that the proposed strategy has good tracking and disturbance suppression performances. 展开更多
关键词 Smooth switching mechanism Integral terminal SMC PMSM servo system Disturbance suppression Stator voltage saturation
原文传递
Sulfolane‑Based Flame‑Retardant Electrolyte for High‑Voltage Sodium‑Ion Batteries
17
作者 Xuanlong He Jie Peng +15 位作者 Qingyun Lin Meng Li Weibin Chen Pei Liu Tao Huang Zhencheng Huang Yuying Liu Jiaojiao Deng Shenghua Ye Xuming Yang Xiangzhong Ren Xiaoping Ouyang Jianhong Liu Biwei Xiao Jiangtao Hu Qianling Zhang 《Nano-Micro Letters》 SCIE EI CAS 2025年第2期498-516,共19页
Sodium-ion batteries hold great promise as next-generation energy storage systems.However,the high instability of the electrode/electrolyte interphase during cycling has seriously hindered the development of SIBs.In p... Sodium-ion batteries hold great promise as next-generation energy storage systems.However,the high instability of the electrode/electrolyte interphase during cycling has seriously hindered the development of SIBs.In particular,an unstable cathode–electrolyte interphase(CEI)leads to successive electrolyte side reactions,transition metal leaching and rapid capacity decay,which tends to be exacerbated under high-voltage conditions.Therefore,constructing dense and stable CEIs are crucial for high-performance SIBs.This work reports localized high-concentration electrolyte by incorporating a highly oxidation-resistant sulfolane solvent with non-solvent diluent 1H,1H,5H-octafluoropentyl-1,1,2,2-tetrafluoroethyl ether,which exhibited excellent oxidative stability and was able to form thin,dense and homogeneous CEI.The excellent CEI enabled the O3-type layered oxide cathode NaNi_(1/3)Mn_(1/3)Fe_(1/3)O_(2)(NaNMF)to achieve stable cycling,with a capacity retention of 79.48%after 300 cycles at 1 C and 81.15%after 400 cycles at 2 C with a high charging voltage of 4.2 V.In addition,its nonflammable nature enhances the safety of SIBs.This work provides a viable pathway for the application of sulfolane-based electrolytes on SIBs and the design of next-generation high-voltage electrolytes. 展开更多
关键词 Sodium-ion batteries Sulfolane-based electrolyte High voltage Layered oxide cathode Flame retardant
在线阅读 下载PDF
Modeling and control of automatic voltage regulation for a hydropower plant using advanced model predictive control 被引量:1
18
作者 Ebunle Akupan Rene Willy Stephen Tounsi Fokui 《Global Energy Interconnection》 2025年第2期269-285,共17页
Fluctuating voltage levels in power grids necessitate automatic voltage regulators(AVRs)to ensure stability.This study examined the modeling and control of AVR in hydroelectric power plants using model predictive cont... Fluctuating voltage levels in power grids necessitate automatic voltage regulators(AVRs)to ensure stability.This study examined the modeling and control of AVR in hydroelectric power plants using model predictive control(MPC),which utilizes an extensive mathe-matical model of the voltage regulation system to optimize the control actions over a defined prediction horizon.This predictive feature enables MPC to minimize voltage deviations while accounting for operational constraints,thereby improving stability and performance under dynamic conditions.Thefindings were compared with those derived from an optimal proportional integral derivative(PID)con-troller designed using the artificial bee colony(ABC)algorithm.Although the ABC-PID method adjusts the PID parameters based on historical data,it may be difficult to adapt to real-time changes in system dynamics under constraints.Comprehensive simulations assessed both frameworks,emphasizing performance metrics such as disturbance rejection,response to load changes,and resilience to uncertainties.The results show that both MPC and ABC-PID methods effectively achieved accurate voltage regulation;however,MPC excelled in controlling overshoot and settling time—recording 0.0%and 0.25 s,respectively.This demonstrates greater robustness compared to conventional control methods that optimize PID parameters based on performance criteria derived from actual system behavior,which exhibited settling times and overshoots exceeding 0.41 s and 5.0%,respectively.The controllers were implemented using MATLAB/Simulink software,indicating a significant advancement for power plant engineers pursuing state-of-the-art automatic voltage regulations. 展开更多
关键词 Automatic voltage regulation Artificial bee colony Evolutionary techniques Model predictive control PID controller HYDROPOWER
在线阅读 下载PDF
混合模型中VAR关于权重的连续性分析
19
作者 王霞 覃建柏 马晓雯 《高等数学研究》 2026年第1期53-54,共2页
在金融风险领域,我们经常需要考虑混合模型的风险度量.本文证明了VAR关于每个模型分配的权重组成的权重向量是连续函数.
关键词 风险度量 var 权重 连续函数
在线阅读 下载PDF