Electricity being a basic national infrastructure for a country, its security, reliability and quality are the most important parameters for the network managers. Several methods are generally used to improve the volt...Electricity being a basic national infrastructure for a country, its security, reliability and quality are the most important parameters for the network managers. Several methods are generally used to improve the voltage quality more and more. However, most of the means implemented depend on external factors independent of the network managers or require huge regular financial resources. The method used in this paper is the loopback, applied to the Southern Interconnected Grid (SIG) of Cameroon, which is the largest net</span><span style="font-family:Verdana;">work in the country. The procedure used takes into account nodes experiencing huge voltage drops and network constraints. The chosen loopback</span><span style="font-family:Verdana;"> scenario results in a clear improvement of the voltage plan in this network, and also a discharge of the transformers, a considerable decongestion of the lines, a reduction of the power losses and a significant reduction of the thermal placement used for improvement of the voltage profile.展开更多
Low voltage start-up was realized in HT-7 discharges under the assistance of lower hybrid (LH) waves. The use of a strong LH wavet which can Change its N// spectrum in a large range of several milliseconds, made the l...Low voltage start-up was realized in HT-7 discharges under the assistance of lower hybrid (LH) waves. The use of a strong LH wavet which can Change its N// spectrum in a large range of several milliseconds, made the loop voltage for start-up reduce from around 20 V to less than 5 V. It means that the electric field for HT-7 start-up decreases from 2.5-3 V/m to 0.6 V/m. Some physical phenomena such as the consumption of magnetic flux in start-up phase and the radiation from the initial plasma were observed in this kind of low voltage start-up discharges.展开更多
When a new user accesses the CDMA system, the load will change drastically, and therefore, the advanced outer loop power control (OLPC) technology has to be adopted to enrich the target signal interference ratio (S...When a new user accesses the CDMA system, the load will change drastically, and therefore, the advanced outer loop power control (OLPC) technology has to be adopted to enrich the target signal interference ratio (Silt) and improve the system performance. The existing problems about DS-CDMA outer loop power control for multi-service are introduced and the power control theoretical model is analyzed. System simulation is adopted on how to obtain the theoretical performance and parameter optimization of the power control algorithm. The OLPC algorithm is improved and the performance comparisons between the old algorithm and the improved algorithm are given. The results show good performance of the improved OLPC algorithm and prove the validity of the improved method for multi-service.展开更多
为提高单相动态电压恢复器(dynamic voltage restorer,DVR)的补偿性能,提出一种基于等效基波及奇次谐波谐振器组的数字控制方法。采用可等效为一组谐振器的延时模块,能够有效抑制电网基波和谐波扰动。给出一种包含两个控制参数和一组...为提高单相动态电压恢复器(dynamic voltage restorer,DVR)的补偿性能,提出一种基于等效基波及奇次谐波谐振器组的数字控制方法。采用可等效为一组谐振器的延时模块,能够有效抑制电网基波和谐波扰动。给出一种包含两个控制参数和一组零相移陷波滤波器的结构及其设计方法,使系统在保证稳定性的同时,获得较大的谐振增益。其中,延时环节衰减系数可增加谐振器组鲁棒性;控制器比例增益可解决零相移陷波器中使用延时带来的问题;零相移陷波器组既能对消LC谐振峰,也能解决等效谐振器组高增益在高频处的稳定性问题。同时,引入电源电压和负载电流双前馈来保证响应速度,增加了对扰动的抑制能力。所提控制策略结构简单,谐波补偿能力强,动态响应快,易于实现。在2kW单相DVR实验装置上的实验结果验证了该控制方法的正确性。展开更多
An outer loop power control algorithm based on triangle norm(t-norm) information fusion technology is proposed in this paper.According to the difference between block error rate and bit error rate with target values,t...An outer loop power control algorithm based on triangle norm(t-norm) information fusion technology is proposed in this paper.According to the difference between block error rate and bit error rate with target values,the membership function calculation and level dividing of the two differences are dealt with.And then t-norm operator is used to fuse the two membership function values to determine the adjustment step-size.The algorithm can acquire the optimal adjustment step-size in the light of the channel status and avoid the overshoot phenomenon of the existing outer power control methods.As a result,the block error rate can converge to the target value quickly.Experiment results verify the excellent property of the algorithm.展开更多
合环转供电是提高供电可靠性的关键手段,但直接合环可能产生较大冲击电流影响电网运行安全性。采用旋转潮流控制器(rotary power flow controller,RPFC)的方式能够实现台区的零感知合环,但电压调节轨迹不当将会带来RPFC接入点的电压越...合环转供电是提高供电可靠性的关键手段,但直接合环可能产生较大冲击电流影响电网运行安全性。采用旋转潮流控制器(rotary power flow controller,RPFC)的方式能够实现台区的零感知合环,但电压调节轨迹不当将会带来RPFC接入点的电压越限问题。对此,提出一种基于两阶段最优路径的RPFC配电网柔性合环方法。首先,对输出电压运行轨迹进行合理规划,将其分为两阶段:第1阶段要求合环点两端电压相位一致并约束电压幅值相等,实现端电压的平稳过渡;第2阶段在相位一致的基础上,控制RPFC输出电压至目标值,使合环点两端电压幅值一致。然后,采用分相量夹角计算和旋转角协调控制,选择就近的旋转角设定值作为目标值,从而实现合环点两端电压无差调节;最后,仿真和实验对比分析所提方法将电压越限至少降低至30%,展示RPFC在实现配电网柔性合环中的重要应用价值。展开更多
文摘Electricity being a basic national infrastructure for a country, its security, reliability and quality are the most important parameters for the network managers. Several methods are generally used to improve the voltage quality more and more. However, most of the means implemented depend on external factors independent of the network managers or require huge regular financial resources. The method used in this paper is the loopback, applied to the Southern Interconnected Grid (SIG) of Cameroon, which is the largest net</span><span style="font-family:Verdana;">work in the country. The procedure used takes into account nodes experiencing huge voltage drops and network constraints. The chosen loopback</span><span style="font-family:Verdana;"> scenario results in a clear improvement of the voltage plan in this network, and also a discharge of the transformers, a considerable decongestion of the lines, a reduction of the power losses and a significant reduction of the thermal placement used for improvement of the voltage profile.
基金This work is supported by Chinese National Nature Science Foundation, contract No.19975048.
文摘Low voltage start-up was realized in HT-7 discharges under the assistance of lower hybrid (LH) waves. The use of a strong LH wavet which can Change its N// spectrum in a large range of several milliseconds, made the loop voltage for start-up reduce from around 20 V to less than 5 V. It means that the electric field for HT-7 start-up decreases from 2.5-3 V/m to 0.6 V/m. Some physical phenomena such as the consumption of magnetic flux in start-up phase and the radiation from the initial plasma were observed in this kind of low voltage start-up discharges.
基金the National Natural Science Foundation of China (60532030).
文摘When a new user accesses the CDMA system, the load will change drastically, and therefore, the advanced outer loop power control (OLPC) technology has to be adopted to enrich the target signal interference ratio (Silt) and improve the system performance. The existing problems about DS-CDMA outer loop power control for multi-service are introduced and the power control theoretical model is analyzed. System simulation is adopted on how to obtain the theoretical performance and parameter optimization of the power control algorithm. The OLPC algorithm is improved and the performance comparisons between the old algorithm and the improved algorithm are given. The results show good performance of the improved OLPC algorithm and prove the validity of the improved method for multi-service.
文摘为提高单相动态电压恢复器(dynamic voltage restorer,DVR)的补偿性能,提出一种基于等效基波及奇次谐波谐振器组的数字控制方法。采用可等效为一组谐振器的延时模块,能够有效抑制电网基波和谐波扰动。给出一种包含两个控制参数和一组零相移陷波滤波器的结构及其设计方法,使系统在保证稳定性的同时,获得较大的谐振增益。其中,延时环节衰减系数可增加谐振器组鲁棒性;控制器比例增益可解决零相移陷波器中使用延时带来的问题;零相移陷波器组既能对消LC谐振峰,也能解决等效谐振器组高增益在高频处的稳定性问题。同时,引入电源电压和负载电流双前馈来保证响应速度,增加了对扰动的抑制能力。所提控制策略结构简单,谐波补偿能力强,动态响应快,易于实现。在2kW单相DVR实验装置上的实验结果验证了该控制方法的正确性。
文摘An outer loop power control algorithm based on triangle norm(t-norm) information fusion technology is proposed in this paper.According to the difference between block error rate and bit error rate with target values,the membership function calculation and level dividing of the two differences are dealt with.And then t-norm operator is used to fuse the two membership function values to determine the adjustment step-size.The algorithm can acquire the optimal adjustment step-size in the light of the channel status and avoid the overshoot phenomenon of the existing outer power control methods.As a result,the block error rate can converge to the target value quickly.Experiment results verify the excellent property of the algorithm.
文摘合环转供电是提高供电可靠性的关键手段,但直接合环可能产生较大冲击电流影响电网运行安全性。采用旋转潮流控制器(rotary power flow controller,RPFC)的方式能够实现台区的零感知合环,但电压调节轨迹不当将会带来RPFC接入点的电压越限问题。对此,提出一种基于两阶段最优路径的RPFC配电网柔性合环方法。首先,对输出电压运行轨迹进行合理规划,将其分为两阶段:第1阶段要求合环点两端电压相位一致并约束电压幅值相等,实现端电压的平稳过渡;第2阶段在相位一致的基础上,控制RPFC输出电压至目标值,使合环点两端电压幅值一致。然后,采用分相量夹角计算和旋转角协调控制,选择就近的旋转角设定值作为目标值,从而实现合环点两端电压无差调节;最后,仿真和实验对比分析所提方法将电压越限至少降低至30%,展示RPFC在实现配电网柔性合环中的重要应用价值。