Analyzing from the perspective of physics mechanics,the pole vault is a project which transforms kinetic energy into elastic potential energy.The magnitude of kinetic energy depends on the vaulter’s approaching speed...Analyzing from the perspective of physics mechanics,the pole vault is a project which transforms kinetic energy into elastic potential energy.The magnitude of kinetic energy depends on the vaulter’s approaching speed,while the magnitude of elastic potential energy depends on height.Therefore,the run-up speed determines the vaulter’s performance in pole vault to a certain extent.the horizontal speed of the pole-holding approach phase transitioning into vertical upward speed plays a crucial role in executing pole vault techniques,and the model of approaching speed establishes a theoretical foundation for vaulters to break through the pole limitation.In terms of specialized technical assistance in speed training,short-distance speed exercises are used in the approaching phase;in the swinging phase,gymnastic rings,single bar and suspension rope exercises are employed for suspension;in the stretch phase,trampoline exercises play a important role in rotation phase,etc.展开更多
AIM:To predict the post-operative vault and the suitable size of the implantable collamer lens(ICL)by comparing the performance of multiple artificial intelligence(AI)algorithms.METHODS:A retrospective analysis of 83 ...AIM:To predict the post-operative vault and the suitable size of the implantable collamer lens(ICL)by comparing the performance of multiple artificial intelligence(AI)algorithms.METHODS:A retrospective analysis of 83 patients with 132 eyes was conducted from 2020 to 2023.All patients underwent implantation of EVO-V4C ICLs.ICLs were selected based on STAAR’s recommended formula.Postoperative vault values were measured using anterior segment optical coherence tomography(ASOCT).First,feature selection was performed on patients’preoperative examination parameters to identify those most closely related to postoperative vault and incorporate them into the machine learning model.Subsequently,four regression models,namely MLP,XGBoost,RFR,and KNN,were employed to predict the vault,and their predictive performances were compared.The ICL size was set as the prediction target,with the vault and other input features serving as new inputs for predicting the ICL size.RESULTS:Among all preoperative parameters,16 parameters were most closely related to postoperative vault and were included in the prediction model.In vault prediction,XGBoost performed the best in the regression model(R^(2)=0.9999),followed by MLP(R^(2)=0.9987)and RFR(R^(2)=0.8982),while the KNN model had the lowest predictive performance(R^(2)=0.3852).XGBoost achieved a prediction accuracy of 99.8%,MLP had a prediction accuracy of 98.9%,while RFR and KNN had accuracies of 87.1%and 57.4%,respectively.CONCLUSION:AI effectively predicts postoperative vault and determines ICL size.XGBoost outperforms other machine-learning algorithms tested.Its accurate predictions help ophthalmologists choose the right ICL size,ensuring proper vaulting.展开更多
Phakic intraocular lens implantation has become one of the important means of correcting refractive errors today.Among them,the implantable collamer lens(ICL)is favored for its wide range of correction,excellent optic...Phakic intraocular lens implantation has become one of the important means of correcting refractive errors today.Among them,the implantable collamer lens(ICL)is favored for its wide range of correction,excellent optical quality,and high safety,but the risks of postoperative complications such as glaucoma and anterior subcapsular opacification still exist.Vault is an important indicator for evaluating the safety after ICL implantation,and its ideal state is crucial for preventing complications.Studies have shown that iris morphology has a significant impact on vault.In order to further optimize surgical outcomes and improve surgical safety,this review comprehensively reviews the research progress of iris-related parameters in ICL implantation and discusses the importance of various parameters in preoperative evaluation and postoperative follow-up.展开更多
AIM:To compare the agreement of anterior chamber depth(ACD)and central vault measurements obtained by anterior segment optical coherence tomography(AS-OCT)and ultrasound biomicroscopy(UBM)of post surgical high ...AIM:To compare the agreement of anterior chamber depth(ACD)and central vault measurements obtained by anterior segment optical coherence tomography(AS-OCT)and ultrasound biomicroscopy(UBM)of post surgical high myopic eyes with posterior chamber phakic intraocular lens(Visian ICL;STAAR Surgical)implantation.·METHODS:Fifty-two phakic eyes of 28 high myopic patients who underwent implantable Collamer lens(ICL)surgery for the correction of high myopia were studied.The postoperative ACD,the distance between the corneal endothelium and the anterior surface of ICL(cornea-ICL)and the central vault were measured with the AS-OCT system and the UBM system.Intraclass correlation coefficient(ICC)and the Bland-Altman plot were used to evaluate the repeatability and agreement of two devices.·R ESULTS:The mean ACD,cornea-ICL and central vault in the 52 phakic eyes after ICL surgery was 3.19±0.28 mm,2.47±0.28 mm,0.50±0.19 mm by AS-OCT and3.13±0.25 mm,2.49±0.25 mm,0.44±0.19 mm by UBM,respectively.Pairwise comparison of ACD and central vault measurements showed significant differences between AS-OCT and UBM(〈0.05).However,no statistically significant difference was found between these imaging techniques in cornea-ICL(〉0.05).The Pearson correlation coefficient()between AS-OCT and UBM measurements for ACD,cornea-ICL and vault was0.88,0.80 and 0.89,respectively(〈0.001).The ICC was0.89-0.94 for the measurements of AS-OCT and UBM.Bland-Altman analysis showed the 95%limits of agreement of ACD,cornea-ICL,central vault measurements between these two devices were-0.20 to 0.32 mm,-0.36to 0.32 mm and-0.12 to 0.24 mm,respectively.58·CONCLUSION:Central ACD and vault measurements using AS-OCT demonstrated a slight significantly higher value than using UBM in phakic eyes after ICL surgery.These two devices should not be used interchangeably for measurements of central ACD and vault in patients after phakic intraocular lens implantation.展开更多
Based on a typical multi-arch tunnel in a freeway, the fast Lagrangian analysis of continua in 3 dimensions(FLAC3D) was used to calculate the surrounding rock deformation of the tunnel under which the effect of underg...Based on a typical multi-arch tunnel in a freeway, the fast Lagrangian analysis of continua in 3 dimensions(FLAC3D) was used to calculate the surrounding rock deformation of the tunnel under which the effect of underground water seepage flow was taken into account or not. The distribution of displacement field around the multi-arch tunnel, which is influenced by the seepage field, was gained. The result indicates that the settlement values of the vault derived from coupling analysis are bigger when considering the seepage flow effect than that not considering. Through the contrast of arch subsidence quantities calculated by two kinds of computation situations, and the comparison between the calculated and measured value of tunnel vault settlement, it is found that the calculated value(5.7-6.0 mm) derived from considering the seepage effect is more close to the measured value(5.8-6.8 mm). Therefore, it is quite necessary to consider the seepage flow effect of the underground water in aquiferous stratum for multi-arch tunnel design.展开更多
soil-cement is a mixture produced by grouting or mixing cement with soils. This paper reviews and discusses the general classifications of grouting techniques and the suitability of their applications.The mechanical p...soil-cement is a mixture produced by grouting or mixing cement with soils. This paper reviews and discusses the general classifications of grouting techniques and the suitability of their applications.The mechanical properties of soil-cement mixture and the influence of sodium silicate added are discussed. Design considerations for deep soil mixed wall(DSMW) for excavation support and vault arch for tunnelling stabilisation are presented. Parameters for the numerical analysis of soil-cement mixture are evaluated and recommended.展开更多
This letter proposes fingerprint-based key binding/recovering with fuzzy vault. Fingerprint minutiae data and the cryptographic key are merged together by a multivariable linear function. First, the minutiae data are ...This letter proposes fingerprint-based key binding/recovering with fuzzy vault. Fingerprint minutiae data and the cryptographic key are merged together by a multivariable linear function. First, the minutiae data are bound by a set of random data through the linear function. The number of the function’s variables is determined by the required number of matched minutiae. Then, a new key de- rived from the random data is used to encrypt the cryptographic key. Lastly, the binding data are protected using fuzzy vault scheme. The proposed scheme provides the system with the flexibility to use changeable number of minutiae to bind/recover the protected key and a unified method regardless of the length of the key.展开更多
文摘Analyzing from the perspective of physics mechanics,the pole vault is a project which transforms kinetic energy into elastic potential energy.The magnitude of kinetic energy depends on the vaulter’s approaching speed,while the magnitude of elastic potential energy depends on height.Therefore,the run-up speed determines the vaulter’s performance in pole vault to a certain extent.the horizontal speed of the pole-holding approach phase transitioning into vertical upward speed plays a crucial role in executing pole vault techniques,and the model of approaching speed establishes a theoretical foundation for vaulters to break through the pole limitation.In terms of specialized technical assistance in speed training,short-distance speed exercises are used in the approaching phase;in the swinging phase,gymnastic rings,single bar and suspension rope exercises are employed for suspension;in the stretch phase,trampoline exercises play a important role in rotation phase,etc.
基金Supported by the National Natural Science Foundation of China(No.82271100)the Jiangsu Science and Technology Support Program(No.BE2022805)the Clinical Skills Enhancement Program of Jiangsu Province Hospital(No.JSPH-MC-2022-24).
文摘AIM:To predict the post-operative vault and the suitable size of the implantable collamer lens(ICL)by comparing the performance of multiple artificial intelligence(AI)algorithms.METHODS:A retrospective analysis of 83 patients with 132 eyes was conducted from 2020 to 2023.All patients underwent implantation of EVO-V4C ICLs.ICLs were selected based on STAAR’s recommended formula.Postoperative vault values were measured using anterior segment optical coherence tomography(ASOCT).First,feature selection was performed on patients’preoperative examination parameters to identify those most closely related to postoperative vault and incorporate them into the machine learning model.Subsequently,four regression models,namely MLP,XGBoost,RFR,and KNN,were employed to predict the vault,and their predictive performances were compared.The ICL size was set as the prediction target,with the vault and other input features serving as new inputs for predicting the ICL size.RESULTS:Among all preoperative parameters,16 parameters were most closely related to postoperative vault and were included in the prediction model.In vault prediction,XGBoost performed the best in the regression model(R^(2)=0.9999),followed by MLP(R^(2)=0.9987)and RFR(R^(2)=0.8982),while the KNN model had the lowest predictive performance(R^(2)=0.3852).XGBoost achieved a prediction accuracy of 99.8%,MLP had a prediction accuracy of 98.9%,while RFR and KNN had accuracies of 87.1%and 57.4%,respectively.CONCLUSION:AI effectively predicts postoperative vault and determines ICL size.XGBoost outperforms other machine-learning algorithms tested.Its accurate predictions help ophthalmologists choose the right ICL size,ensuring proper vaulting.
基金Key Research and Development Projects of Zhejiang Science and Technology Plan(No.2021C03103)Research and Development Plan of Zhejiang Science and Technology Department(No.2023C03089)Scientific Research Project of Zhejiang Provincial Department of Education(No.Y202456401)。
文摘Phakic intraocular lens implantation has become one of the important means of correcting refractive errors today.Among them,the implantable collamer lens(ICL)is favored for its wide range of correction,excellent optical quality,and high safety,but the risks of postoperative complications such as glaucoma and anterior subcapsular opacification still exist.Vault is an important indicator for evaluating the safety after ICL implantation,and its ideal state is crucial for preventing complications.Studies have shown that iris morphology has a significant impact on vault.In order to further optimize surgical outcomes and improve surgical safety,this review comprehensively reviews the research progress of iris-related parameters in ICL implantation and discusses the importance of various parameters in preoperative evaluation and postoperative follow-up.
文摘AIM:To compare the agreement of anterior chamber depth(ACD)and central vault measurements obtained by anterior segment optical coherence tomography(AS-OCT)and ultrasound biomicroscopy(UBM)of post surgical high myopic eyes with posterior chamber phakic intraocular lens(Visian ICL;STAAR Surgical)implantation.·METHODS:Fifty-two phakic eyes of 28 high myopic patients who underwent implantable Collamer lens(ICL)surgery for the correction of high myopia were studied.The postoperative ACD,the distance between the corneal endothelium and the anterior surface of ICL(cornea-ICL)and the central vault were measured with the AS-OCT system and the UBM system.Intraclass correlation coefficient(ICC)and the Bland-Altman plot were used to evaluate the repeatability and agreement of two devices.·R ESULTS:The mean ACD,cornea-ICL and central vault in the 52 phakic eyes after ICL surgery was 3.19±0.28 mm,2.47±0.28 mm,0.50±0.19 mm by AS-OCT and3.13±0.25 mm,2.49±0.25 mm,0.44±0.19 mm by UBM,respectively.Pairwise comparison of ACD and central vault measurements showed significant differences between AS-OCT and UBM(〈0.05).However,no statistically significant difference was found between these imaging techniques in cornea-ICL(〉0.05).The Pearson correlation coefficient()between AS-OCT and UBM measurements for ACD,cornea-ICL and vault was0.88,0.80 and 0.89,respectively(〈0.001).The ICC was0.89-0.94 for the measurements of AS-OCT and UBM.Bland-Altman analysis showed the 95%limits of agreement of ACD,cornea-ICL,central vault measurements between these two devices were-0.20 to 0.32 mm,-0.36to 0.32 mm and-0.12 to 0.24 mm,respectively.58·CONCLUSION:Central ACD and vault measurements using AS-OCT demonstrated a slight significantly higher value than using UBM in phakic eyes after ICL surgery.These two devices should not be used interchangeably for measurements of central ACD and vault in patients after phakic intraocular lens implantation.
基金Project(50490274) supported by the National Natural Science Foundation of ChinaProject(200516) supported by Hunan Transportation Science and Technology
文摘Based on a typical multi-arch tunnel in a freeway, the fast Lagrangian analysis of continua in 3 dimensions(FLAC3D) was used to calculate the surrounding rock deformation of the tunnel under which the effect of underground water seepage flow was taken into account or not. The distribution of displacement field around the multi-arch tunnel, which is influenced by the seepage field, was gained. The result indicates that the settlement values of the vault derived from coupling analysis are bigger when considering the seepage flow effect than that not considering. Through the contrast of arch subsidence quantities calculated by two kinds of computation situations, and the comparison between the calculated and measured value of tunnel vault settlement, it is found that the calculated value(5.7-6.0 mm) derived from considering the seepage effect is more close to the measured value(5.8-6.8 mm). Therefore, it is quite necessary to consider the seepage flow effect of the underground water in aquiferous stratum for multi-arch tunnel design.
基金financially supported by Tianjin Key Technology Development Plan(#15PTYJGX00030,KYWX-201701)
文摘soil-cement is a mixture produced by grouting or mixing cement with soils. This paper reviews and discusses the general classifications of grouting techniques and the suitability of their applications.The mechanical properties of soil-cement mixture and the influence of sodium silicate added are discussed. Design considerations for deep soil mixed wall(DSMW) for excavation support and vault arch for tunnelling stabilisation are presented. Parameters for the numerical analysis of soil-cement mixture are evaluated and recommended.
基金Supported by the National Natural Science Foundation of China (No.60472069)
文摘This letter proposes fingerprint-based key binding/recovering with fuzzy vault. Fingerprint minutiae data and the cryptographic key are merged together by a multivariable linear function. First, the minutiae data are bound by a set of random data through the linear function. The number of the function’s variables is determined by the required number of matched minutiae. Then, a new key de- rived from the random data is used to encrypt the cryptographic key. Lastly, the binding data are protected using fuzzy vault scheme. The proposed scheme provides the system with the flexibility to use changeable number of minutiae to bind/recover the protected key and a unified method regardless of the length of the key.