The aim of this study was to determine the unit load of NPS (non-point source) pollutants including organic variables such as BOD (biochemical oxygen demand), COD (chemical oxygen demand) and DOC (dissolved org...The aim of this study was to determine the unit load of NPS (non-point source) pollutants including organic variables such as BOD (biochemical oxygen demand), COD (chemical oxygen demand) and DOC (dissolved organic carbon), nitrogen and phosphorus constituents, and suspended solids (SS) and their event mean concentration (EMC) of runoff flows from a water-shed of mixed forest land use by intensive field experiments. Field monitoring for continuous measurements of rainfall, flow, and water quality was conducted over 12 storm events during 2008-2009 using automated and manual sampling methods. The EMCs of individual runoff event were estimated for each water quality constituent based on the flow rate and concentration data of runoff discharge. The average EMCs of BOD, COD, DOC, SS, TN (total nitrogen), NH4^+-N, NO3^--N, TP (total phosphorus), PO4^3-P from the mixed forest land were 1.794, 3.498, 1.462, 10.269, 0.862, 0.044, 0.634, 0.034, and 0.005 mg/L, respectively. The annual unit loads of BOD, COD, DOC, SS, TN, NH4^+-N, NO3^--N, TP and PO4^3--P were estimated as 66.9, 133.2, 55.5, 429.8, 36.5, 1.6, 26.9, 1.3 and 0.1 kg/(ha·yr), respectively. In addition, affecting parameters on the EMCs were investigated by statistic analysis of the field data. As a result, significant correlations with precipitation, rainfall intensity, and total runoff flows were found in most constituents.展开更多
远程终端单元(remote terminal unit, RTU)是当前电网中最主要的测量终端,但是其量测量没有统一时标,更新频率低,而且存在不确定性的传输时延。而同步相量测量单元(phasor measurement unit, PMU)具有高同步、高精度等特点,成为电力系...远程终端单元(remote terminal unit, RTU)是当前电网中最主要的测量终端,但是其量测量没有统一时标,更新频率低,而且存在不确定性的传输时延。而同步相量测量单元(phasor measurement unit, PMU)具有高同步、高精度等特点,成为电力系统中重要的数据采集装置。为协调利用这两种测量数据,首先归纳出RTU量测非同步的来源,分析了量测数据不同步对状态估计和潮流计算的影响,并给出了相关的验证结果。并提出基于能量交互算子的量测数据相关性分析方法。该方法应用同步数据间相关性最大的原理,利用PMU所产生的精确数据来同步RTU数据,为混合测量系统确定测量基准时刻。通过对IEEE39节点电网和广东83节点实际电网的仿真,结果表明该方法能有效校正量测数据非同步以及改善状态估计和潮流计算精度。展开更多
基金supported by the National Institute of Environmental Research,Korea
文摘The aim of this study was to determine the unit load of NPS (non-point source) pollutants including organic variables such as BOD (biochemical oxygen demand), COD (chemical oxygen demand) and DOC (dissolved organic carbon), nitrogen and phosphorus constituents, and suspended solids (SS) and their event mean concentration (EMC) of runoff flows from a water-shed of mixed forest land use by intensive field experiments. Field monitoring for continuous measurements of rainfall, flow, and water quality was conducted over 12 storm events during 2008-2009 using automated and manual sampling methods. The EMCs of individual runoff event were estimated for each water quality constituent based on the flow rate and concentration data of runoff discharge. The average EMCs of BOD, COD, DOC, SS, TN (total nitrogen), NH4^+-N, NO3^--N, TP (total phosphorus), PO4^3-P from the mixed forest land were 1.794, 3.498, 1.462, 10.269, 0.862, 0.044, 0.634, 0.034, and 0.005 mg/L, respectively. The annual unit loads of BOD, COD, DOC, SS, TN, NH4^+-N, NO3^--N, TP and PO4^3--P were estimated as 66.9, 133.2, 55.5, 429.8, 36.5, 1.6, 26.9, 1.3 and 0.1 kg/(ha·yr), respectively. In addition, affecting parameters on the EMCs were investigated by statistic analysis of the field data. As a result, significant correlations with precipitation, rainfall intensity, and total runoff flows were found in most constituents.
文摘远程终端单元(remote terminal unit, RTU)是当前电网中最主要的测量终端,但是其量测量没有统一时标,更新频率低,而且存在不确定性的传输时延。而同步相量测量单元(phasor measurement unit, PMU)具有高同步、高精度等特点,成为电力系统中重要的数据采集装置。为协调利用这两种测量数据,首先归纳出RTU量测非同步的来源,分析了量测数据不同步对状态估计和潮流计算的影响,并给出了相关的验证结果。并提出基于能量交互算子的量测数据相关性分析方法。该方法应用同步数据间相关性最大的原理,利用PMU所产生的精确数据来同步RTU数据,为混合测量系统确定测量基准时刻。通过对IEEE39节点电网和广东83节点实际电网的仿真,结果表明该方法能有效校正量测数据非同步以及改善状态估计和潮流计算精度。