期刊文献+
共找到571篇文章
< 1 2 29 >
每页显示 20 50 100
Load Balancing Control Strategy for Multi-Substation Flexible Interconnection Distribution Networks Considering Unbalanced Power Compensation
1
作者 Qiji Dai Jikai Li +3 位作者 Bohui Ning Yutao Xu Chang Liu Xuan Zhang 《Energy Engineering》 2025年第10期4061-4080,共20页
Aiming at the challenge of complex load balancing coordination for a three-phase four-leg(3P4L)based multi-ended low voltage flexible DC distribution system(M-LVDC)considering unbalanced power compensation,this paper ... Aiming at the challenge of complex load balancing coordination for a three-phase four-leg(3P4L)based multi-ended low voltage flexible DC distribution system(M-LVDC)considering unbalanced power compensation,this paper proposes a phase-split power decoupling unbalanced compensation strategy based load balancing strategy for 3P4L based M-LVDC.Firstly,the topology and operation principle of the 3P4L-based M-LVDC system is introduced,and quasi-proportional resonant(QPR)based phase-split power current control for the 3P4L converter is proposed.Secondly,a load-balancing control strategy considering unbalanced compensation for 3P4L-based MLVDC is presented,in which the control diagrams for each 3P4L-based converter are detailed.The core idea of the proposed strategy is to comprehensively consider the imbalance compensation and load rate balancing between the two areas to calculate the split-phase power and current reference values of each 3P4L converter and achieve the static error-free tracking of the reference values through the QPR current inner-loop control.These reference values are then tracked with zero steady-state error using QPR current inner-loop control.Finally,the effectiveness of the proposed control strategy is verified through a 3P4L M-LVDC case study conducted on the PSCAD/EMTDC software.Theresults indicate that the proposed method not only can reduce the three-phase imbalance degrees from>20% to<0.5%,but also achieve excellent balanced load rates,with the load-rate difference smaller than 1.5%. 展开更多
关键词 three-phase four-bridge-arm Quasi-PR direct current control unbalanced power compensation
在线阅读 下载PDF
A novel control strategy for load converter of DC isolated distribution system under unbalanced loading conditions 被引量:1
2
作者 R.NOROOZIAN M.ABEDI +1 位作者 G.B.GHAREHPETIAN S.H.HOSSEINI 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2009年第6期890-899,共10页
A novel control strategy for the load converter supplying the unbalanced AC load in a DC isolated distribution system is presented. The control algorithm results in balanced and sinusoidal load voltages under unbalanc... A novel control strategy for the load converter supplying the unbalanced AC load in a DC isolated distribution system is presented. The control algorithm results in balanced and sinusoidal load voltages under unbalanced AC loading. The unbalanced load is characterized in the d-q-0 rotating coordinate based on symmetrical sequence components. Also, the mathematical model of the load converter in both a-b-c and d-q-0 coordinates is derived by using the average large signal model. Then, two control strategies for the load converter are presented. The first one uses the conventional d-q-0 controller to ensure the voltage and current regulation. The second one is a newly proposed control strategy based on the decomposition of the voltage and current into in-stantaneous positive, negative, and zero sequences. These three sequences are controlled independently in their own reference frames as DC signals. The performance of the load converter using these two control strategies is compared. Simulation results show the validity and capability of the newly proposed control strategy. 展开更多
关键词 unbalanced load Power quality Symmetrical components Control strategy
原文传递
Energy-balanced clustering protocol for data gathering in wireless sensor networks with unbalanced traffic load 被引量:1
3
作者 奎晓燕 王建新 张士庚 《Journal of Central South University》 SCIE EI CAS 2012年第11期3180-3187,共8页
Energy-efficient data gathering in multi-hop wireless sensor networks was studied,considering that different node produces different amounts of data in realistic environments.A novel dominating set based clustering pr... Energy-efficient data gathering in multi-hop wireless sensor networks was studied,considering that different node produces different amounts of data in realistic environments.A novel dominating set based clustering protocol (DSCP) was proposed to solve the data gathering problem in this scenario.In DSCP,a node evaluates the potential lifetime of the network (from its local point of view) assuming that it acts as the cluster head,and claims to be a tentative cluster head if it maximizes the potential lifetime.When evaluating the potential lifetime of the network,a node considers not only its remaining energy,but also other factors including its traffic load,the number of its neighbors,and the traffic loads of its neighbors.A tentative cluster head becomes a final cluster head with a probability inversely proportional to the number of tentative cluster heads that cover its neighbors.The protocol can terminate in O(n/lg n) steps,and its total message complexity is O(n2/lg n).Simulation results show that DSCP can effectively prolong the lifetime of the network in multi-hop networks with unbalanced traffic load.Compared with EECT,the network lifetime is prolonged by 56.6% in average. 展开更多
关键词 ENERGY-BALANCE CLUSTERING data gathering wireless sensor networks unbalanced traffic load
在线阅读 下载PDF
Three-Phase Unbalance Prediction of Electric Power Based on Hierarchical Temporal Memory 被引量:1
4
作者 Hui Li Cailin Shi +2 位作者 Xin Liu Aziguli Wulamu Alan Yang 《Computers, Materials & Continua》 SCIE EI 2020年第8期987-1004,共18页
The difference in electricity and power usage time leads to an unbalanced current among the three phases in the power grid.The three-phase unbalanced is closely related to power planning and load distribution.When the... The difference in electricity and power usage time leads to an unbalanced current among the three phases in the power grid.The three-phase unbalanced is closely related to power planning and load distribution.When the unbalance occurs,the safe operation of the electrical equipment will be seriously jeopardized.This paper proposes a Hierarchical Temporal Memory(HTM)-based three-phase unbalance prediction model consisted by the encoder for binary coding,the spatial pooler for frequency pattern learning,the temporal pooler for pattern sequence learning,and the sparse distributed representations classifier for unbalance prediction.Following the feasibility of spatial-temporal streaming data analysis,we adopted this brain-liked neural network to a real-time prediction for power load.We applied the model in five cities(Tangshan,Langfang,Qinhuangdao,Chengde,Zhangjiakou)of north China.We experimented with the proposed model and Long Short-term Memory(LSTM)model and analyzed the predict results and real currents.The results show that the predictions conform to the reality;compared to LSTM,the HTM-based prediction model shows enhanced accuracy and stability.The prediction model could serve for the overload warning and the load planning to provide high-quality power grid operation. 展开更多
关键词 three-phase unbalance power load prediction model hierarchical temporal memory
在线阅读 下载PDF
Optimal Control for Vienna Rectifier in Unbalanced Conditions
5
作者 LIU Chengzi HUANG Xiaoqi +1 位作者 MA Yaopeng BEN Guicin 《Transactions of Nanjing University of Aeronautics and Astronautics》 2025年第3期385-394,共10页
The Vienna rectifier is a widely adopted solution for high-power rectification due to its efficiency and straightforward design.However,its performance can degrade under unbalanced three phase voltage conditions,leadi... The Vienna rectifier is a widely adopted solution for high-power rectification due to its efficiency and straightforward design.However,its performance can degrade under unbalanced three phase voltage conditions,leading to current zero-crossing distortion and compromised dynamic response.This paper investigates the causes of these distortions,identifying a phase shift between the input current and the grid voltage as a primary factor,and proposes an effective distortion phase identification strategy.Furthermore,the dynamic performance is enhanced through improved current reference calculations and a refined power feedforward strategy.This approach optimizes the system's response to load changes and maintains output voltage stability under unbalanced conditions.Simulation results validate the effectiveness of the proposed methods in reducing current distortion and improving overall performance. 展开更多
关键词 zero-crossing distortion three-phase voltage unbalanced RECTIFIER power feedforward
在线阅读 下载PDF
Research on a New Control Strategy of Three Phase Inverter for Unbalanced Loads
6
作者 Wenhua HU Weiming Ma Chunxi LIU 《Journal of Electromagnetic Analysis and Applications》 2010年第1期39-44,共6页
One of the very important functions of three-phase inverter is to maintain the symmetric three-phase output voltage when the three-phase loads are unbalanced. Although the traditional symmetrical component decomposing... One of the very important functions of three-phase inverter is to maintain the symmetric three-phase output voltage when the three-phase loads are unbalanced. Although the traditional symmetrical component decomposing and superimpose theory can keep the voltage balance through compensating the positive-, negative- and zero-sequence components of the output voltage of inverter, however, this method is time-consuming and not suitable for control. Aiming at high power medium frequency inverter source, a P+Resonant (Proportion and Resonant) controller which ensured a balanced three phase output voltage under unbalanced load is proposed in this paper. The regulator was proved to be applicable to both three-phase three-wire system and three-phase four-wire system and developed two methods of realization. The simulation results verified that this method can suppressed effectively the output voltage distorted caused by the unbalanced load and attained a high quality voltage waveforms. 展开更多
关键词 three-phase INVERTER unbalanced load the three-phase OUTPUT Voltage SYMMETRIC MEDIUM Frequency P+Resonant Controller
暂未订购
Unbalanced Load Simulation of Electronic Power Transformer in Distribution System
7
作者 Wang Dan Mao Chengxiong +3 位作者 Lu Jiming Fan Shu Cao Jiewei Wang Ben(Translated) 《Electricity》 2006年第1期38-43,共6页
A control scheme of electronic power transformer (EPT) in a three-phase four-wire distribution system, which included an input section, an isolating section and an output section, was researched under unbalanced loads... A control scheme of electronic power transformer (EPT) in a three-phase four-wire distribution system, which included an input section, an isolating section and an output section, was researched under unbalanced loads. The simple and appropriate control scheme was developed through analyzing the system requirements of the primary side and the load requirements of the secondary side. In the input section, a dual-loop control in synchronous rotating d-q coordinates was introduced, and in the output section, a dual-loop control based on instantaneous output voltage was used. Load characteristics of EPT were investigated by using Matlab/Simulink software. Simulation results showed that, with the proposed control scheme, the EPT has good performances and the sinusoidal input current and constant output voltage can be realized under both balanced and unbalanced loads. 展开更多
关键词 electronic power transformer distribution system unbalanced load
在线阅读 下载PDF
Electromagnetic Performance Prediction for the Symmetrical Dual Three-phase Surface-mounted PMSM under Open-phase Faults Based on Accurate Subdomain Model 被引量:1
8
作者 Zhe Liang Deliang Liang +1 位作者 Peng Kou Shaofeng Jia 《CES Transactions on Electrical Machines and Systems》 CSCD 2022年第4期422-437,共16页
The paper presents an accurate analytical subdomain model for predicting the electromagnetic performance in the symmetrical dual three-phase surface-mounted permanent magnet synchronous machine(PMSM)under open-phase f... The paper presents an accurate analytical subdomain model for predicting the electromagnetic performance in the symmetrical dual three-phase surface-mounted permanent magnet synchronous machine(PMSM)under open-phase faulty conditions.The model derivations are extended from previous accurate subdomain models accounting for slotting effects.Compared with most conventional subdomain models for traditional three-phase machines with nonoverlapping winding arrangement,the subdomain model proposed in this paper applied for the 24-slot/4-pole dual three-phase machine with symmetrical overlapping winding arrangement.In order to investigate the postfault electromagnetic performance,the reconfigured phase currents and then current density distribution in stator slots under different open-circuit conditions are discussed.According to the developed model and postfault current density distribution,the steady-state electromagnetic performance,such as the electromagnetic torque and unbalanced magnetic force,under open-circuit faulty conditions are obtained.For validation purposes,finite element analysis(FEA)is employed to validate the analytical results.The result indicate that the postfault electromagnet performance can be accurately predicted by the proposed subdomain model,which is in good agreement with FEA results. 展开更多
关键词 Dual three-phase Permanent magnet synchronous machine Subdomain model Electromagnetic torque unbalanced magnetic force Open-phase fault
在线阅读 下载PDF
The Control Technology Research of the Z-source Three-phase Four-bridge Arm Inverter
9
作者 Xiangli Li Zhaoyang Yan +2 位作者 Keke Pan Chenghao Ma Hanhong Qi 《Energy and Power Engineering》 2013年第4期733-739,共7页
Z-source inverter can boost the voltage of the DC-side, allow the two switches of the same bridge arm conducting at the same time and it has some other advantages. The zero-sequence current flows through the fourth le... Z-source inverter can boost the voltage of the DC-side, allow the two switches of the same bridge arm conducting at the same time and it has some other advantages. The zero-sequence current flows through the fourth leg of the three-phase four-leg inverter so the three-phase four-leg inverter can work with unbalanced load. This paper presents a Z-source three-phase four-leg inverter which combines a Z-source network with three-phase four-leg inverter. The circuit uses simple SPWM modulation technique and the fourth bridge arm uses fully compensated control method. The inverter can maintain a symmetrical output voltage when the proposed scheme under the unbalanced load. 展开更多
关键词 Z-SOURCE INVERTER three-phase FOUR-LEG INVERTER unbalanced load Imbalanced VOLTAGE
在线阅读 下载PDF
不平衡载荷下洗煤厂胶带机滚动轴承异常振动特性分析
10
作者 杨小权 李博 乔少利 《机械设计与制造工程》 2026年第1期107-111,共5页
在变频驱动方式下,洗煤厂胶带机滚动轴承异常振动特性会发生较为复杂的变化,为此提出一种适用于不平衡载荷条件下的洗煤厂胶带机滚动轴承异常振动特性分析方法。基于变频器在胶带机中的运行原理,分析变频驱动方式及不平衡载荷对胶带机... 在变频驱动方式下,洗煤厂胶带机滚动轴承异常振动特性会发生较为复杂的变化,为此提出一种适用于不平衡载荷条件下的洗煤厂胶带机滚动轴承异常振动特性分析方法。基于变频器在胶带机中的运行原理,分析变频驱动方式及不平衡载荷对胶带机滚动轴承振动的影响;通过压电式加速度传感器,获取振动信息;结合计算阶次跟踪方法和总体经验模式分解方法,分析变频驱动方式及不平衡载荷下滚动轴承异常振动特性。测试结果表明,该分析方法可以准确地评估滚动轴承在变频驱动方式及不平衡载荷下的振动特性,为洗煤厂胶带机的故障检测和预警提供了良好的数据支持。 展开更多
关键词 不平衡载荷 胶带机滚动轴承 异常振动特性 变频驱动方式
在线阅读 下载PDF
Modeling method of sequence admittance for three-phase voltage source converter under unbalanced grid condition 被引量:1
11
作者 Yang CEN Meng HUANG Xiaoming ZHA 《Journal of Modern Power Systems and Clean Energy》 SCIE EI 2018年第3期595-606,共12页
The admittance is a strong tool for stability analysis and assessment of the three-phase voltage source converters(VSCs) especially in grid-connected mode.However, the sequence admittance is hard to calculate when the... The admittance is a strong tool for stability analysis and assessment of the three-phase voltage source converters(VSCs) especially in grid-connected mode.However, the sequence admittance is hard to calculate when the VSC is operating under unbalanced grid voltage conditions. In this paper, a simple and direct modeling method is proposed for a three-phase VSC taking the unbalanced grid voltage as a new variable for the system.Then coupling in the three-phase system can be calculated by applying the harmonic linearization method. The calculated admittance of three-phase VSCs is verified by detailed circuit simulations. 展开更多
关键词 unbalanced GRID VOLTAGE three-phase VOLTAGE source converter Harmonic linearization Positive and negative SEQUENCE ADMITTANCE Stability
原文传递
板柱节点考虑弯剪相关性的受冲切承载力计算方法
12
作者 郑文忠 吕盛先 +1 位作者 郑博文 王英 《哈尔滨工业大学学报》 EI CAS 北大核心 2025年第1期65-76,共12页
对于同时受到竖向荷载和不平衡弯矩作用的板柱节点,目前已有方法大多将不平衡弯矩等效为竖向荷载,从而给出其受冲切承载力计算方法。但该方法所涉及的不平衡弯矩比例系数的计算还存在较大争议,且没有考虑竖向荷载与不平衡弯矩耦合的影... 对于同时受到竖向荷载和不平衡弯矩作用的板柱节点,目前已有方法大多将不平衡弯矩等效为竖向荷载,从而给出其受冲切承载力计算方法。但该方法所涉及的不平衡弯矩比例系数的计算还存在较大争议,且没有考虑竖向荷载与不平衡弯矩耦合的影响。因此,本文首先通过推导给出仅有竖向荷载作用的板柱节点受冲切承载力计算公式和仅有不平衡弯矩作用的板柱节点受弯承载力计算公式,并与试验结果进行对比,验证了所提公式的合理性。然后基于板柱节点在竖向荷载和不平衡弯矩共同作用下的试验结果,拟合得到板柱节点考虑弯剪相关性的受冲切承载力计算公式。最后对所提计算方法与不同规范计算方法进行对比,结果表明本文计算方法能够更加准确地预测板柱节点受冲切承载力。 展开更多
关键词 板柱节点 竖向荷载 不平衡弯矩 受冲切承载力 计算方法
在线阅读 下载PDF
网侧电压不对称下负载不平衡电流计算方法
13
作者 王清亮 陈轩 +2 位作者 张浩楠 李瑞琪 王伟峰 《电网与清洁能源》 北大核心 2025年第10期103-111,共9页
针对现有方法无法有效分离并准确计算网侧电压不对称下负载不平衡电流的不足,提出了一种适用于配电网公共连接点处的负载不平衡电流计算方法。依据德国DIN40110-2标准对完美负载定义及负载电流分解的基本思想,通过计算负载不平衡等效电... 针对现有方法无法有效分离并准确计算网侧电压不对称下负载不平衡电流的不足,提出了一种适用于配电网公共连接点处的负载不平衡电流计算方法。依据德国DIN40110-2标准对完美负载定义及负载电流分解的基本思想,通过计算负载不平衡等效电导和集总参数,利用分数阶结构算法优越的负序频率选频特性,从正交电流中提取出负载无功不平衡电流,实现在电压不对称条件下对负载不平衡电流的分离与计算。实验分析表明,所提方法可在时域内直接对网侧电压不对称下负载不平衡电流进行准确计算。 展开更多
关键词 负载不平衡 完美负载 集总参数 分数阶结构
在线阅读 下载PDF
基于时域迭代法的三相不平衡微电网潮流计算方法研究
14
作者 朱一昕 吴浩宇 +3 位作者 陈宇杰 许德智 卢闻州 徐伊洁 《电气工程学报》 北大核心 2025年第6期301-311,共11页
潮流计算是分析系统运行状态的基础,传统三相不平衡系统潮流算法实质多为求解非线性潮流方程,计算复杂,且若初值设置不当,可能会出现收敛问题。针对以上问题,基于时域迭代理念,引入对称分量分析,提出一种适用于下垂控制分布式发电(Distr... 潮流计算是分析系统运行状态的基础,传统三相不平衡系统潮流算法实质多为求解非线性潮流方程,计算复杂,且若初值设置不当,可能会出现收敛问题。针对以上问题,基于时域迭代理念,引入对称分量分析,提出一种适用于下垂控制分布式发电(Distributed generation,DG)单元的三相不平衡微电网潮流计算方法。首先,建立下垂控制DG单元离散运行模型,使用时域推导而非方程计算DG单元输出功率,避免收敛问题;其次,将三相不平衡的三相三线制系统基于对称分量法分解为相互独立的正负序网络,并根据网络连接情况与网络参数建立正负序网络馈线与负载模型;然后,推导正负序完整网络模型并行迭代计算,迭代过程中不需更新网络矩阵,降低计算规模;最后,基于IEEE-8节点系统算例进行仿真,并建立相应Simulink模型验证该算法的有效性。 展开更多
关键词 下垂控制 三相不平衡 对称分量法 时域迭代法 潮流计算
在线阅读 下载PDF
A Second-Order Sliding Mode Controller of Quad-Rotor UAV Based on PID Sliding Mode Surface with Unbalanced Load 被引量:7
15
作者 KANG Bing MIAO Yan +3 位作者 LIU Fu DUAN Jilu WANG Ke JIANG Shoukun 《Journal of Systems Science & Complexity》 SCIE EI CSCD 2021年第2期520-536,共17页
Quad-rotor unmanned aerial vehicle(UAV)is a typical multiple-input-multiple-output underactuated system with couplings and nonlinearity.Usually,the flying environment is very complex,so that it is impossible for the U... Quad-rotor unmanned aerial vehicle(UAV)is a typical multiple-input-multiple-output underactuated system with couplings and nonlinearity.Usually,the flying environment is very complex,so that it is impossible for the UAV to avoid effects derived from disturbances and uncertainties.In order to improve the reliability of flight control,we established the dynamic model of quad-rotor UAV by Newton-Euler equation in unbalanced load conditions.Considering external disturbances in the attitude,a second-order sliding mode controller was designed with PID sliding mode surface and Extended State Observer(ESO).The simulation experiments have got good control performance,illustrating the effectiveness of our controller.Meanwhile,the controller was implemented in a quadrotor UAV,which carried a pan-tilt camera for aerial photography.The actual flight experiments proved that this paper dealt with the high stabilization flight control problem for the quad-rotor UAV,which laid a good foundation for autonomous flight of the UAV. 展开更多
关键词 Quad-rotor UAV sliding mode controller unbalanced load
原文传递
风力发电机偏航齿轮箱太阳轮断齿失效分析 被引量:1
16
作者 厉旭旺 黄成彦 +3 位作者 李贵方 范焕 王瀚 魏煜锋 《机械传动》 北大核心 2025年第2期118-124,共7页
【目的】偏航系统的疲劳载荷是风力发电机产生故障的主要原因,偏航驱动等齿轮箱断齿、断轴现象仍为高频故障。失效分析结果表明,原材料的生产工艺、组织调控结果、宏观力学性能调配、部件装配间隙、啮合关系、振动影响是主要的失效原因... 【目的】偏航系统的疲劳载荷是风力发电机产生故障的主要原因,偏航驱动等齿轮箱断齿、断轴现象仍为高频故障。失效分析结果表明,原材料的生产工艺、组织调控结果、宏观力学性能调配、部件装配间隙、啮合关系、振动影响是主要的失效原因。研究分析这些规律,可以查明陆上风机偏航驱动齿轮箱太阳轮输出齿的断齿故障原因,为后续风机的偏航系统研究设计提供技术支撑。【方法】通过对失效输出齿的理化性能测试、SEM断口分析,排查了齿轮结构设计、机组运行状态,确定了断齿原因。【结果】结果表明,输出齿的表层马氏体组织异常分解,导致表面硬度不足58 HRC、硬化层深度偏浅10%,降低了轮齿的表面接触强度;断面残留多个约5μm非金属夹杂物,齿根表面机加工刀痕粗糙,降低了轮齿齿根弯曲强度;运行过程中齿条间有效啮合区仅50%,存在严重偏载,导致轮齿工作应力超出许用应力,诱发齿面疲劳磨损及早期开裂,后期载荷超出承载极限时产生断齿。该偏载断齿现象经机加工艺及齿形优化后有一定改善。 展开更多
关键词 太阳轮 失效 非金属夹杂物 组织异常 偏载
在线阅读 下载PDF
Balance control of grid currents for UPQC under unbalanced loads based on matching-ratio compensation algorithm 被引量:2
17
作者 Xiaojun ZHAO Chunjiang ZHANG +3 位作者 Xiuhui CHAI Jinlong ZHANG Fanqi LIU Zhe ZHANG 《Journal of Modern Power Systems and Clean Energy》 SCIE EI 2018年第6期1319-1331,共13页
In three-phase four-wire systems, unbalanced loads can cause grid currents to be unbalanced, and this may cause the neutral point potential on the grid side to shift. The neutral point potential shift will worsen the ... In three-phase four-wire systems, unbalanced loads can cause grid currents to be unbalanced, and this may cause the neutral point potential on the grid side to shift. The neutral point potential shift will worsen the control precision as well as the performance of the threephase four-wire unified power quality conditioner(UPQC),and it also leads to unbalanced three-phase output voltage,even causing damage to electric equipment. To deal with unbalanced loads, this paper proposes a matching-ratio compensation algorithm(MCA) for the fundamental active component of load currents, and by employing this MCA,balanced three-phase grid currents can be realized under 100% unbalanced loads. The steady-state fluctuation and the transient drop of the DC bus voltage can also be restrained. This paper establishes the mathematical model of the UPQC, analyzes the mechanism of the DC bus voltage fluctuations, and elaborates the interaction between unbalanced grid currents and DC bus voltage fluctuations;two control strategies of UPQC under three-phase stationary coordinate based on the MCA are given, and finally, the feasibility and effectiveness of the proposed control strategy are verified by experiment results. 展开更多
关键词 Unified power quality conditioner(UPQC) unbalanced loads Matching-ratio compensation BALANCE control DC bus voltage FLUCTUATIONS
原文传递
基于WSA-ICN算法优化的风电机组独立变桨控制策略 被引量:1
18
作者 魏成新 王海云 +3 位作者 郝伟栋 丁国栋 苏洪军 连昊 《科学技术与工程》 北大核心 2025年第23期9851-9858,共8页
为了解决大型风电机组在高风速运行时存在的不平衡载荷及功率波动问题,同时有效降低噪声,提出了一种基于鲸鱼群算法(whale swarm algorithm,WSA)优化的比例、积分、微分(proportional,integral,derivative,PID)独立变桨控制策略。首先,... 为了解决大型风电机组在高风速运行时存在的不平衡载荷及功率波动问题,同时有效降低噪声,提出了一种基于鲸鱼群算法(whale swarm algorithm,WSA)优化的比例、积分、微分(proportional,integral,derivative,PID)独立变桨控制策略。首先,利用叶素动量理论建立了风机气动载荷模型,并对气动载荷问题的来源及气动噪声的产生机理进行分析。其次,为有效抑制不平衡载荷及功率波动,将WSA-ICN(iterative counter and neighborhood)算法与PID控制方法相结合,搭建了基于WSA-ICN优化的风电机组独立变桨控制模型。最后,通过FAST-Simulink联合仿真平台,深入分析了不同控制策略下的载荷和噪声特性。结果表明:所提控制策略在抑制不平衡载荷及功率波动方面表现优于传统控制方法,且一定程度上降低了风电机组电气噪声,验证了该优化控制模型的有效性。 展开更多
关键词 功率波动 不平衡载荷 鲸鱼群算法 降噪 独立变桨 PID控制
在线阅读 下载PDF
航空无人机高速长轴转子系统动力学分析
19
作者 郑传威 宋朝省 +1 位作者 吴安阳 王耀禄 《重庆大学学报》 北大核心 2025年第1期1-9,共9页
针对某型航空高速长轴转子系统振动问题,考虑不同轴承支撑形式和轴承阻尼,建立了高速长轴转子系统计算模型,基于Ansys Workbench研究了轴承支撑形式与轴承阻尼对临界转速的影响规律。系统在刚性支撑时的临界转速远高于柔性支撑时的临界... 针对某型航空高速长轴转子系统振动问题,考虑不同轴承支撑形式和轴承阻尼,建立了高速长轴转子系统计算模型,基于Ansys Workbench研究了轴承支撑形式与轴承阻尼对临界转速的影响规律。系统在刚性支撑时的临界转速远高于柔性支撑时的临界转速;系统在同为刚性支撑下,考虑轴承阻尼时,临界转速随着阻尼的增大而减小,而随着阶次越高,轴承阻尼对临界转速的影响也逐渐减小。此外,系统在不同位置处的谐响应情况基本一致;系统响应幅值随着不平衡量增大而增大;系统响应幅值随着阻尼增大均呈现增大的趋势。 展开更多
关键词 高速长轴转子系统 轴承支撑形式 轴承阻尼 临界转速 不平衡量 谐响应
在线阅读 下载PDF
铁路货运发站超偏载源头防治的研究与实践 被引量:2
20
作者 张善东 《铁路物流》 2025年第2期52-57,共6页
为更好地发挥铁路绿色低碳优势,服务国家发展战略,切实提升铁路货物运输安全管理水平,对铁路货运超偏载安全管理现状及发站超偏载源头防治存在的问题进行分析,从加强新型超偏载检测设备的研发和应用、货运装载质量监控管理信息化研究、... 为更好地发挥铁路绿色低碳优势,服务国家发展战略,切实提升铁路货物运输安全管理水平,对铁路货运超偏载安全管理现状及发站超偏载源头防治存在的问题进行分析,从加强新型超偏载检测设备的研发和应用、货运装载质量监控管理信息化研究、加强发站源头超偏载管理等方面入手,做好货运发站超偏载的源头防治工作。经实践证明从加强技防手段、夯实安全管理2方面入手,不仅能够实现从发站源头上控制货车的超偏载问题,而且能够减少超偏载核实车对铁路运输安全和效率带来的影响,为打造铁路物流新品牌,服务铁路现代物流体系建设提供有力支撑。 展开更多
关键词 铁路 货运安全 超偏载 现代物流 信息化
在线阅读 下载PDF