期刊文献+
共找到1,730篇文章
< 1 2 87 >
每页显示 20 50 100
Modeling and Experimental Study of an Open Two-Phase Loop Driven by Osmotic Pressure and Capillary Force
1
作者 Hanli Bi Zheng Peng +5 位作者 Chenpeng Liu Zhichao Jia Guoguang Li Yuandong Guo Hongxing Zhang Jianyin Miao 《Frontiers in Heat and Mass Transfer》 2025年第1期55-70,共16页
As space technology advances,thermal control systems must effectively collect and dissipate heat from distributed,multi-source environments.Loop heat pipe is a highly reliable two-phase heat transfer component,but it ... As space technology advances,thermal control systems must effectively collect and dissipate heat from distributed,multi-source environments.Loop heat pipe is a highly reliable two-phase heat transfer component,but it has several limitations when addressing multi-source heat dissipation.Inspired by the transport and heat dissipation system of plants,large trees achieve stable and efficient liquid supply under the influence of two driving forces:capillary force during transpiration in the leaves(pull)and root pressure generated by osmotic pressure in the roots(push).The root pressure provides an effective liquid supply with a driving force exceeding 2 MPa,far greater than the driving force in conventional capillary-pumped two-phase loops.Research has shown that osmotic heat pipes offer a powerful driving force,and combining osmotic pressure with capillary force has significant advantages.Therefore,this paper designs a multi-evaporator,dual-drive two-phase loop,using both osmotic pressure and capillary force to solve the multi-source heat dissipation challenge.First,a transmembrane water flux model for the osmotic pressure-driven device was established to predict the maximum heat transfer capacity of the dual-drive two-phase loop.Then,an experimental setup for a multi-evaporator“osmotic pressure+capillary force”dual-drive two-phase loop was constructed,capable of transferring at least 235 W of power under a reverse gravity condition of 20 m.The study also analyzed the effects of reverse gravity height,heat load distribution among the three evaporators,startup sequence,and varying branch resistances on the performance of the dual-drive two-phase loop. 展开更多
关键词 Multi-heat sources osmotic pressure two-phase loop dual-drive loop heat pipe
在线阅读 下载PDF
Simulation of CO_(2)-water two-phase fluid displacement characteristics based on the phase field method
2
作者 Changnu Zeng Yiyang Zhang +1 位作者 Hu Lu Zhao Lu 《Deep Underground Science and Engineering》 2025年第4期725-738,共14页
The two-phase flow in porous media is affected by multiple factors.In the present study,a two-dimensional numerical model of porous media was developed using the actual pore structure of the core sample.The phase fiel... The two-phase flow in porous media is affected by multiple factors.In the present study,a two-dimensional numerical model of porous media was developed using the actual pore structure of the core sample.The phase field method was utilized to simulate the impact of displacement velocity,the water-gas viscosity ratio,and the density ratio on the flow behavior of two-phase fluids in porous media.The effectiveness of displacement was evaluated by analyzing CO_(2)saturation levels.The results indicate that the saturation of CO_(2)in porous media increased as the displacement velocity increased.When the displacement velocity exceeded 0.01 m/s,there was a corresponding increase in CO_(2)saturation.Conversely,when the displacement velocity was below this threshold,the impact on CO_(2)saturation was minimal.An“inflection point,”M3,was present in the viscosity ratio.When the viscosity of CO_(2)is less than 8.937×10^(-5)Pa·s(viscosity ratio below M3),variations in the viscosity of CO_(2)had little impact on its saturation.Conversely,when the viscosity of CO_(2)exceeded 8.937×10^(-5)Pa·s(viscosity ratio greater than M3),saturation increased with an increase in the viscosity ratio.In terms of the density ratio,the saturation of CO_(2)increased monotonically with an increase in the density ratio.Similarly,increasing density ratios resulted in a monotonic increase in CO_(2)saturation,though this trend was less pronounced in numerical simulations.Analysis results of displacement within dead-end pores using pressure and velocity diagrams reveal eddy currents as contributing factors.Finally,the impact of pore throat structure on the formation of dominant channels was examined. 展开更多
关键词 CO_(2)geological storage displacement efficiency enhancement phase field method real core two-phase flow
原文传递
A control volume based finite element method for simulating incompressible two-phase flow in heterogeneous porous media and its application to reservoir engineering 被引量:4
3
作者 SADRNEJAD S A GHASEMZADEH H +1 位作者 GHOREISHIAN AMIRI S A MONTAZERI G H 《Petroleum Science》 SCIE CAS CSCD 2012年第4期485-497,共13页
Applying the standard Galerkin finite element method for solving flow problems in porous media encounters some difficulties such as numerical oscillation at the shock front and discontinuity of the velocity field on e... Applying the standard Galerkin finite element method for solving flow problems in porous media encounters some difficulties such as numerical oscillation at the shock front and discontinuity of the velocity field on element faces.Discontinuity of velocity field leads this method not to conserve mass locally.Moreover,the accuracy and stability of a solution is highly affected by a non-conservative method.In this paper,a three dimensional control volume finite element method is developed for twophase fluid flow simulation which overcomes the deficiency of the standard finite element method,and attains high-orders of accuracy at a reasonable computational cost.Moreover,this method is capable of handling heterogeneity in a very rational way.A fully implicit scheme is applied to temporal discretization of the governing equations to achieve an unconditionally stable solution.The accuracy and efficiency of the method are verified by simulating some waterflooding experiments.Some representative examples are presented to illustrate the capability of the method to simulate two-phase fluid flow in heterogeneous porous media. 展开更多
关键词 Finite element method control volume two-phase flow HETEROGENEITY porous media WATERFLOODING
原文传递
Application of Two-dimensional Viscous CE/SE Method in Calculation of Two-phase Detonation 被引量:6
4
作者 马丹花 翁春生 《Defence Technology(防务技术)》 SCIE EI CAS 2010年第1期5-9,共5页
The method of two-dimensional viscous space-time conservation element and solution element (CE/SE) can be used to calculate the gas-liquid two-phase interior flow field in pulse detonation engine (PDE). In this paper,... The method of two-dimensional viscous space-time conservation element and solution element (CE/SE) can be used to calculate the gas-liquid two-phase interior flow field in pulse detonation engine (PDE). In this paper, the evolution of the detonation wave and the distribution of its physical parameters were analyzed. The numerical results show that the change of axial velocity of gas is the same as that of detonation pressure. The larger the liquid droplet radius is, the longer the time to get stable detonation wave is. The calculated results coincide with the experimented results better. 展开更多
关键词 explosion mechanics pulse detonation engine interior ballistics CE/SE method two-phase detonation numerical calculation
在线阅读 下载PDF
Extension of the low diffusion particle method for near-continuum two-phase flow simulations 被引量:3
5
作者 Su Wei He Xiaoying Cai Guobiao 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 2013年第1期37-46,共10页
The low diffusion (LD) particle method, proposed by Burt and Boyd, is modified for the near-continuum two-phase flow simulations. The LD method has the advantages of easily coupling with the direct simulation Monte ... The low diffusion (LD) particle method, proposed by Burt and Boyd, is modified for the near-continuum two-phase flow simulations. The LD method has the advantages of easily coupling with the direct simulation Monte Carlo (DSMC) method for multi-scale flow simulations and dramatically reducing the numerical diffusion error and statistical scatter of the equilibrium particle methods. Liquidor solid-phase particles are introduced in the LD method. Their velocity and temperature updating are respectively, calculated from the motion equation and the temperature equation according to the local gas properties. Coupling effects from condensed phase to gas phase are modeled as momentum and energy sources, which are respectively, equal to the negative values of the total momentum and energy increase in liquid or solid phase. The modified method is compared with theoretical results for unsteady flows, and good agreements are obtained to indicate the reliability of the one-way gas-to-particle coupling models. Hybrid LD-DSMC algorithm is implemented and performed for nozzle discharging gas-liquid flow to show the prospect of the LD-DSMC scheme for multi-scale two-phase flow simulations. 展开更多
关键词 DSMC method Hybrid simulation Low diffusion particle method Motion relaxation Temperature relaxation two-phase flow
原文传递
Reconstruction of electrical capacitance tomography images based on fast linearized alternating direction method of multipliers for two-phase flow system 被引量:4
6
作者 Chongkun Xia Chengli Su +1 位作者 Jiangtao Cao Ping Li 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2016年第5期597-605,共9页
Electrical capacitance tomography(ECT)has been applied to two-phase flow measurement in recent years.Image reconstruction algorithms play an important role in the successful applications of ECT.To solve the ill-posed ... Electrical capacitance tomography(ECT)has been applied to two-phase flow measurement in recent years.Image reconstruction algorithms play an important role in the successful applications of ECT.To solve the ill-posed and nonlinear inverse problem of ECT image reconstruction,a new ECT image reconstruction method based on fast linearized alternating direction method of multipliers(FLADMM)is proposed in this paper.On the basis of theoretical analysis of compressed sensing(CS),the data acquisition of ECT is regarded as a linear measurement process of permittivity distribution signal of pipe section.A new measurement matrix is designed and L1 regularization method is used to convert ECT inverse problem to a convex relaxation problem which contains prior knowledge.A new fast alternating direction method of multipliers which contained linearized idea is employed to minimize the objective function.Simulation data and experimental results indicate that compared with other methods,the quality and speed of reconstructed images are markedly improved.Also,the dynamic experimental results indicate that the proposed algorithm can ful fill the real-time requirement of ECT systems in the application. 展开更多
关键词 Electrical capacitance tomography Image reconstruction Compressed sensing Alternating direction method of multipliers two-phase flow
在线阅读 下载PDF
Experimental study on dynamic behavior of mechanically pumped two-phase loop with a novel accumulator in simulated space environment 被引量:3
7
作者 Qingliang MENG Tao ZHANG +3 位作者 Feng YU Yu ZHAO Zhenming ZHAO Zhenhua ZHOU 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 2022年第12期102-116,共15页
Mechanically pumped two-phase loop(MPTL)which is a prominent two-phase heat transfer technology presents a promising prospect in thermal control for space payload.However,transient behavior of MPTL caused by phase-cha... Mechanically pumped two-phase loop(MPTL)which is a prominent two-phase heat transfer technology presents a promising prospect in thermal control for space payload.However,transient behavior of MPTL caused by phase-change and heat sources load-on/off in simulated space environment is rarely reported.In the present study,one MPTL setup was designed and constructed,and experimentally studied.Particularly,a novel two-phase thermally-controlled accumulator integrated with passive cooling measure and three capillary structures was designed as the temperature-control device.Dynamic behavior of the start-up,temperature control,and temperature adjustment were monitored;meanwhile,thermodynamic behavior within the proposed accumulator,the operating behavior as well as the heat and mass transfer behavior between the main loop and the accumulator were revealed.The results show that the fluid management function of the capillary structures for the novel accumulator is verified.The working point of the MPTL system can be adjusted by changing the temperature control point of the accumulator and it is little influenced by external heat flux and heat sources on/off.Pressure-drop oscillations which are manifested as fluctuations of temperature and pressure can be observed after phase changing due to the compressible volume within the accumulator and the negative-slope portion of the internal pressure. 展开更多
关键词 Heat and mass transfer Mechanically pumped twophase loop(MPTL) Pressure drop fluctuation Thermal control two-phase flow
原文传递
Determination of dynamic capillary effect on two-phase flow in porous media: A perspective from various methods 被引量:2
8
作者 Jian-Chao Cai Yin Chen +3 位作者 Jun-Cheng Qiao Liu Yang Jian-Hui Zeng Chen-Hao Sun 《Petroleum Science》 SCIE CAS CSCD 2022年第4期1641-1652,共12页
The relationship between capillary pressure and saturation plays a critical role in the characterization of two-phase flow and transport in aquifers and oil reservoirs. This relationship is usually determined under th... The relationship between capillary pressure and saturation plays a critical role in the characterization of two-phase flow and transport in aquifers and oil reservoirs. This relationship is usually determined under the static condition, where capillary pressure is the only function of saturation. However,considerable experiments have suggested that the dependence of capillary pressure on desaturation rate is under the dynamic condition. Thus, a more general description of capillary pressure that includes dynamic capillary effect has been approved widely. A comprehensive understanding of the dynamic capillary effect is needed for the investigation of the two-phase flow in porous media by various methods. In general, dynamic capillary effect in porous media can be studied through the laboratory experiment, pore-to macro-scale modeling, and artificial neural network. Here, main principle and research procedures of each method are reviewed in detail. Then, research progress, disadvantages and advantages are discussed, respectively. In addition, upscaling study from pore-to macro-scale are introduced, which explains the difference between laboratory experiment and pore-scale modeling. At last, several future perspectives and recommendations for optimal solution of dynamic capillary effect are presented. 展开更多
关键词 Dynamic capillary effect Capillary pressure two-phase flow Modeling method
原文传递
Reconstructing bubble profiles from gas-liquid two-phase flow data using agglomerative hierarchical clustering method 被引量:2
9
作者 WU Dong-ling SONG Yan-po +1 位作者 PENG Xiao-qi GAO Dong-bo 《Journal of Central South University》 SCIE EI CAS CSCD 2019年第8期2056-2067,共12页
The knowledge of bubble profiles in gas-liquid two-phase flows is crucial for analyzing the kinetic processes such as heat and mass transfer, and this knowledge is contained in field data obtained by surface-resolved ... The knowledge of bubble profiles in gas-liquid two-phase flows is crucial for analyzing the kinetic processes such as heat and mass transfer, and this knowledge is contained in field data obtained by surface-resolved computational fluid dynamics (CFD) simulations. To obtain this information, an efficient bubble profile reconstruction method based on an improved agglomerative hierarchical clustering (AHC) algorithm is proposed in this paper. The reconstruction method is featured by the implementations of a binary space division preprocessing, which aims to reduce the computational complexity, an adaptive linkage criterion, which guarantees the applicability of the AHC algorithm when dealing with datasets involving either non-uniform or distorted grids, and a stepwise execution strategy, which enables the separation of attached bubbles. To illustrate and verify this method, it was applied to dealing with 3 datasets, 2 of them with pre-specified spherical bubbles and the other obtained by a surface-resolved CFD simulation. Application results indicate that the proposed method is effective even when the data include some non-uniform and distortion. 展开更多
关键词 bubble profile reconstruction gas-liquid two-phase flow clustering method surface-resolved computational fluid dynamics (CFD) distorted bubble shape
在线阅读 下载PDF
NEW STUDYING OF LATTICE BOLTZMANN METHOD FOR TWO-PHASE DRIVEN IN POROUS MEDIA 被引量:1
10
作者 许友生 刘慈群 俞慧丹 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI 2002年第4期387-393,共7页
By using the interaction of particles, such as the physical principle of the same attract each other and the different repulse each other, a new model of Lattice Boltzmann to simulate the two-phase driven in porous me... By using the interaction of particles, such as the physical principle of the same attract each other and the different repulse each other, a new model of Lattice Boltzmann to simulate the two-phase driven in porous media was discussed. The result shows effectively for the problem of two-phase driven in porous media. Furthermore, the method economizes on computer time, has less fluctuation on boundary surface and takes no average measure. 展开更多
关键词 porous medium two-phase driven method of lattice Boltzmann(LBM)
在线阅读 下载PDF
Modelling of a Two-Phase Thermosyphon Loop for Passive Air-Conditioning of a House in Hot and Dry Climate Countries 被引量:1
11
作者 Abdoulaye 1 Diallo Xavier Chesneau +1 位作者 Idrissa Diaby Djanfar El-Maktoume 《Energy and Power Engineering》 2021年第6期243-260,共18页
The two-phase thermosyphon loop is an efficient solution for space cooling. This paper presents the simulation results of numerical studies on the heat transfer and thermal performance of a two-phase thermosiphon loop... The two-phase thermosyphon loop is an efficient solution for space cooling. This paper presents the simulation results of numerical studies on the heat transfer and thermal performance of a two-phase thermosiphon loop for passive air-conditioning of a house. The fluid considered in this study is methanol, which is compatible with copper and is environmentally friendly. These numerical results show that the temperature at the evaporator wall drops from 23<span style="color:#111111;font-family:Roboto, sans-serif;font-size:16px;white-space:normal;background-color:#FFFFFF;">°</span>C to 13<span style="color:#111111;font-family:Roboto, sans-serif;font-size:16px;white-space:normal;background-color:#FFFFFF;">°</span>C and increases at the condenser. The solar flux density has a strong influence on the condenser temperature. The mass flow rates and masses at the evaporator and condenser increase with temperature. The variation of evaporating and condensing temperature affects the performance of the system. For a constant evaporating and condensing temperature of 2<span style="color:#111111;font-family:Roboto, sans-serif;font-size:16px;white-space:normal;background-color:#FFFFFF;">°</span>C and 29<span style="color:#111111;font-family:Roboto, sans-serif;font-size:16px;white-space:normal;background-color:#FFFFFF;">°</span>C, the COP is 0.77 and 0.84 respectively. With these results, the use of the two-phase thermosyphon loop in air conditioning is possible to obtain a thermal comfort of the occupants acceptable by the standards but with a large exchange surface of the evaporator. 展开更多
关键词 two-phase Thermosiphon loop MODELLING Passive Air Conditioning Thermal Performance
在线阅读 下载PDF
Two-phase Method without Any Artificial Variable 被引量:1
12
作者 梁平 张旭利 张相斌 《Northeastern Mathematical Journal》 CSCD 2008年第5期395-398,共4页
A method is provided to achieve an initial basic feasible solution of a linear programming in this paper. This method dose not need introducing any artificial variable, but needs only solving an auxiliary linear progr... A method is provided to achieve an initial basic feasible solution of a linear programming in this paper. This method dose not need introducing any artificial variable, but needs only solving an auxiliary linear programming. Compared with the traditional two-phase method, it has advantages of saving the memories and reducing the computational efforts. 展开更多
关键词 initial basic feasible solution auxiliary linear programming two-phase method artificial variable
在线阅读 下载PDF
Numerical Simulation of Gas-Water Two-Phase Flow in a Proppant-Filled Layer
13
作者 Jian Yang Xinghao Gou +4 位作者 Jiayi Sun Fei Liu Xiaojin Zhou Xu Liu Tao Zhang 《Fluid Dynamics & Materials Processing》 2025年第8期1935-1954,共20页
Shale gas production involves complex gas-water two-phase flow,with flow patterns in proppant-filled fractures playing a critical role in determining production efficiency.In this study,3D geometric models of 40/70 me... Shale gas production involves complex gas-water two-phase flow,with flow patterns in proppant-filled fractures playing a critical role in determining production efficiency.In this study,3D geometric models of 40/70 mesh ceramic particles and quartz sand proppant clusters were elaborated using computed tomography(CT)scanning.These models were used to develop a numerical simulation framework based on the lattice Boltzmann method(LBM),enabling the investigation of gas-water flow behavior within proppant-filled fractures under varying driving forces and surface tensions.Simulation results at a closure pressure of 15 MPa have revealed that ceramic particles exhibit a simpler and more porous internal structure than quartz sand of the same size.Under identical flow conditions,ceramic proppants demonstrate higher fluid replacement efficiency.Replacement efficiency increases with higher porosity,greater driving force,and lower surface tension.Furthermore,fluid displacement is strongly influenced by pore geometry:flow is faster in straighter and wider channels,with preferential movement through larger pores forming dominant flow paths.The replacement velocity exhibits a characteristic time evolution,initially rapid,then gradually decreasing,correlating positively with the development of these dominant channels. 展开更多
关键词 Proppant fractures gas-water two-phase flow numerical simulation lattice Boltzmann method flow behavior
在线阅读 下载PDF
A new deliverability evaluation method of gas condensate wells in gaseliquid two-phase state 被引量:1
14
作者 Lu Jialiang Zhang Hao +2 位作者 Chang Baohua Cao Wen Sun Hedong 《Natural Gas Industry B》 2018年第6期583-588,共6页
Gas well deliverability evaluation and analysis are challenging due to the frequent abnormalities of deliverability test data of gas condensate wells caused by seepage of oil and gas phases in the reservoirs.To this e... Gas well deliverability evaluation and analysis are challenging due to the frequent abnormalities of deliverability test data of gas condensate wells caused by seepage of oil and gas phases in the reservoirs.To this end,based upon the pseudo-single-phase seepage equation and the oilegas two-phase seepage equation,a new deliverability evaluation method was established which is applicable to the following two cases when the flow of a gas well reaches the quasi-steady stage,i.e.,the pseudo-single-phase stable point deliverability evaluation for the case when the formation pressure is above the dew pressure;the gaseliquid two-phase stable point deliverability evaluation for the case when the formation pressure is below the dew pressure.Using this established deliverability evaluation method,based on the basic parameters of the Yaha gas field,Tarim Basin,the IPR curves were first obtained of gas wells do not get this at the same production gaseoil ratio and at the formation pressure above and below the dew point pressure;then,according to the four condensate gas fields,such as Yaha,Tazhong I,Qianmiqiao and Dina 2,the absolute open flow(AOF)potentials of condensate gas wells under different gaseoil production ratios were calculated.Finally,through statistical analysis of the calculation results from typical wells,the following findings were obtained.This new deliverability evaluation method under the two states of condensate gas wells with quasi-single-phase and gaseliquid two-phase stable points can be used to avoid cases due to the oilegas flow in a condensate gas well which has remained unresolved by the classical deliverability evaluation methods.Also,with the increase of gaseoil ratios in gas condensate wells,a variable discrepancy is gradually reduced in AOF potentials calculated respectively by the quasi-single-phase and gaseliquid two-phase stable point deliverability evaluation equations.For the condensate gas wells with high condensate content and low condensate gas production rates,the AOF potentials calculated by the gaseliquid two-phase stable point deliverability equation is more appropriate and reliable compared with that obtained by classical methods. 展开更多
关键词 Gas condensate reservoir Gas well Gaseliquid two-phase flow Turbulent flow equation Quasi-single-phase Gaseliquid two-phase Stable point Deliverability evaluation method Absolute open flow potential
在线阅读 下载PDF
CHARACTERISTIC DIFFERENCE METHODS FOR TWO-PHASE DISPLACEMENT IN NATURALLY FRACTURED RESERVOIRS
15
作者 芮洪兴 《Numerical Mathematics A Journal of Chinese Universities(English Series)》 SCIE 1995年第2期133-146,共14页
In this paper we shall give the characteristic difference methods for two phase displace meat problem in naturally fractured reservoirs.We shall prove the existence,uniqueness of the ap proximate solution and a priori... In this paper we shall give the characteristic difference methods for two phase displace meat problem in naturally fractured reservoirs.We shall prove the existence,uniqueness of the ap proximate solution and a priori discrete L2-error estimates. 展开更多
关键词 DIFFERENCE method two-phase DISPLACEMENT naturally fructured RESERVOIRS
在线阅读 下载PDF
Three-dimensional multi-relaxation-time lattice Boltzmann front-tracking method for two-phase flow
16
作者 谢海琼 曾忠 张良奇 《Chinese Physics B》 SCIE EI CAS CSCD 2016年第1期663-668,共6页
We developed a three-dimensional multi-relaxation-time lattice Boltzmann method for incompressible and immiscible two-phase flow by coupling with a front-tracking technique. The flow field was simulated by using an Eu... We developed a three-dimensional multi-relaxation-time lattice Boltzmann method for incompressible and immiscible two-phase flow by coupling with a front-tracking technique. The flow field was simulated by using an Eulerian grid, an adaptive unstructured triangular Lagrangian grid was applied to track explicitly the motion of the two-fluid interface, and an indicator function was introduced to update accurately the fluid properties. The surface tension was computed directly on a triangular Lagrangian grid, and then the surface tension was distributed to the background Eulerian grid. Three benchmarks of two-phase flow, including the Laplace law for a stationary drop, the oscillation of a three-dimensional ellipsoidal drop, and the drop deformation in a shear flow, were simulated to validate the present model. 展开更多
关键词 multi-relaxation-time lattice Boltzmann method front-tracking method surface tension two-phase flow
原文传递
Multi-relaxation-time lattice Boltzmann front tracking method for two-phase flow with surface tension
17
作者 谢海琼 曾忠 +3 位作者 张良奇 梁功有 Hiroshi Mizuseki Yoshiyuki Kawazoe 《Chinese Physics B》 SCIE EI CAS CSCD 2012年第12期310-316,共7页
In this paper, an improved incompressible multi-relaxation-time lattice Boltzmann-front tracking approach is proposed to simulate two-phase flow with a sharp interface, where the surface tension is implemented. The la... In this paper, an improved incompressible multi-relaxation-time lattice Boltzmann-front tracking approach is proposed to simulate two-phase flow with a sharp interface, where the surface tension is implemented. The lattice Boltzmann method is used to simulate the incompressible flow with a stationary Eulerian grid, an additional moving Lagrangian grid is adopted to track explicitly the motion of the interface, and an indicator function is introduced to update the fluid properties accurately. The interface is represented by using a four-order Lagrange polynomial through fitting a set of discrete marker points, and then the surface tension is directly computed by using the normal vector and curvature of the interface. Two benchmark problems, including Laplace's law for a stationary bubble and the dispersion relation of the capillary wave between two fluids are conducted for validation. Excellent agreement is obtained between the numerical simulations and the theoretical results in the two cases. 展开更多
关键词 lattice Boltzmann method multi-relaxation-time front tracking method surface ten- sion two-phase flow
原文传递
Gradient-augmented hybrid interface capturing method for incompressible two-phase flow
18
作者 付峥 吴士玉 刘凯欣 《Chinese Physics B》 SCIE EI CAS CSCD 2016年第6期283-289,共7页
Motivated by inconveniences of present hybrid methods,a gradient-augmented hybrid interface capturing method(GAHM) is presented for incompressible two-phase flow.A front tracking method(FTM) is used as the skeleto... Motivated by inconveniences of present hybrid methods,a gradient-augmented hybrid interface capturing method(GAHM) is presented for incompressible two-phase flow.A front tracking method(FTM) is used as the skeleton of the GAHM for low mass loss and resources.Smooth eulerian level set values are calculated from the FTM interface,and are used for a local interface reconstruction.The reconstruction avoids marker particle redistribution and enables an automatic treatment of interfacial topology change.The cubic Hermit interpolation is employed in all steps of the GAHM to capture subgrid structures within a single spacial cell.The performance of the GAHM is carefully evaluated in a benchmark test.Results show significant improvements of mass loss,clear subgrid structures,highly accurate derivatives(normals and curvatures) and low cost.The GAHM is further coupled with an incompressible multiphase flow solver,Super CE/SE,for more complex and practical applications.The updated solver is evaluated through comparison with an early droplet research. 展开更多
关键词 interface capturing hybrid method mass loss incompressible two-phase flow
原文传递
Simulation of gas–liquid two-phase flow in a flow-focusing microchannel with the lattice Boltzmann method
19
作者 冯凯 杨刚 张会臣 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第11期527-536,共10页
A lattice Boltzmann method for gas–liquid two-phase flow involving non-Newtonian fluids is developed. Bubble formation in a flow-focusing microchannel is simulated by the method. The influences of flow rate ratio, su... A lattice Boltzmann method for gas–liquid two-phase flow involving non-Newtonian fluids is developed. Bubble formation in a flow-focusing microchannel is simulated by the method. The influences of flow rate ratio, surface tension,wetting properties, and rheological characteristics of the fluid on the two-phase flow are analyzed. The results indicate that the flow pattern transfers from slug flow to dry-plug flow with a sufficiently small capillary number. Due to the presence of three-phase contact lines, the contact angle has a more significant effect on the dry-plug flow pattern than on the slug flow pattern. The deformation of the front and rear meniscus of a bubble in the shear-thinning fluid can be explained by the variation of the capillary number. The reduced viscosity and increased contact angle are beneficial for the drag reduction in a microchannel. It also demonstrates the effectiveness of the current method to simulate the gas–liquid two-phase flow in a microchannel. 展开更多
关键词 two-phase flow lattice Boltzmann method pressure drop flow-focusing microchannel
原文传递
THE SOLUTION FOR TRANSIENT TWO-PHASE FLOW BY SPLIT FLUX VECTOR METHOD
20
作者 翁荣周 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI 1992年第11期1039-1046,共8页
In this paper the transient two-phase flow equations and their eigenvalues are first introduced. The flux vector is then split into subvectors which just contain a specially signed eigenvalue. Using one-sided spatial ... In this paper the transient two-phase flow equations and their eigenvalues are first introduced. The flux vector is then split into subvectors which just contain a specially signed eigenvalue. Using one-sided spatial difference operators finite difference equations and their solutions are obtained. Finally comparison with experiment shows the predicted results produce good agreement with experimental data. 展开更多
关键词 two-phase flow vector flux split flux vector method
在线阅读 下载PDF
上一页 1 2 87 下一页 到第
使用帮助 返回顶部