Spectral measurement of tungsten(W)impurity is essential to study impurity transport.Therefore,an X-ray crystal spectrometer(XCS)on EAST was used to measure the line spectra from highly ionized W ions.On EAST,both pol...Spectral measurement of tungsten(W)impurity is essential to study impurity transport.Therefore,an X-ray crystal spectrometer(XCS)on EAST was used to measure the line spectra from highly ionized W ions.On EAST,both poloidal XCS and tangential XCS have been developed to measure the plasma temperature as well as the rotation velocity.Recently,He-like and H-like argon spectra have also been obtained using a two-crystal setup.W lines are identified in this study.Through a careful analysis,the W lines of 3.9336,3.9321,and 3.664(A)are found to be diffracted by He-like or H-like crystals.The lines are confirmed with the NIST database.We also calculated the ion temperature with Doppler broadening of these lines.The ion temperature from the W lines is entirely consistent with that from Ar line spectra.The measurement of these W line spectra could be used to study W impurity transport in future work.展开更多
To simultaneously measure the He-like and H-like argon spectra, a two-crystal assembly has been deployed to replace the previous single crystal on the tangential x-ray crystal spectrometer.By selecting appropriate cry...To simultaneously measure the He-like and H-like argon spectra, a two-crystal assembly has been deployed to replace the previous single crystal on the tangential x-ray crystal spectrometer.By selecting appropriate crystals with similar Bragg angles, plasma temperature in the range of 0.5 keV≤Te≤10 keV and rotation can be diagnosed based on the He-like and H-like argon spectra. However, due to the added complexity in the two-crystal assembly in which the spectra might be diffracted by two crystals, some additional impurity lines were identified. For example,tungsten(W) lines in different ionization states were diffracted by the He-like and H-like crystal.Additional molybdenum(Mo) lines in the wavelength range of He-like and H-like argon spectra lines were also summarized. The existence of these additional lines caused the fitted temperature to be different from the true values. This paper presents the identified lines through a comparison with available database, which should be included in the fitting procedure.展开更多
基金the National Magnetic Confinement Fusion Science Program of China(Nos.2017YFE0301300 and 2018YFE0301100)the Key Program of Research and Development of the Hefei Science Center(No.2017HSC-KPRD002)+7 种基金National Natural Science Foundation of China(Nos.11805231 and 11705151)the ASIPP Science and Research Grant(No.DSJJ-17-03)the Anhui Provincial Natural Science Foundation(Nos.1808085QA14 and 1908085J01)the Instrument Developing Project of the Chi-nese Academy of Sciences(No.YJKYYQ20180013)the Collaborative Innovation Program of Hefei Science Center,CAS(No.2019HSC-CIP005)the Nature Science Foundation of Hunan Province(2017JJ3268)the Hunan Nuclear Fusion International Science and Technology Innovation Coopera-tion Base(No.2018WK4009)the Key Laboratory of Magnetic Confinement Nuclear Fusion Research in Hengyang(No.2018KJ108).
文摘Spectral measurement of tungsten(W)impurity is essential to study impurity transport.Therefore,an X-ray crystal spectrometer(XCS)on EAST was used to measure the line spectra from highly ionized W ions.On EAST,both poloidal XCS and tangential XCS have been developed to measure the plasma temperature as well as the rotation velocity.Recently,He-like and H-like argon spectra have also been obtained using a two-crystal setup.W lines are identified in this study.Through a careful analysis,the W lines of 3.9336,3.9321,and 3.664(A)are found to be diffracted by He-like or H-like crystals.The lines are confirmed with the NIST database.We also calculated the ion temperature with Doppler broadening of these lines.The ion temperature from the W lines is entirely consistent with that from Ar line spectra.The measurement of these W line spectra could be used to study W impurity transport in future work.
基金partially supported by the National Magnetic Confinement Fusion Science Program of China(No.2015GB103002)Key Program of Research and Development of Hefei Science Center(No.2017HSC-KPRD002)+1 种基金the Major Program of Development Foundation of Hefei Center for Physical Science and Technology(No.2016FXZY008)the CASHIPS Director’s Funds Grant(No.YZJJ201612)
文摘To simultaneously measure the He-like and H-like argon spectra, a two-crystal assembly has been deployed to replace the previous single crystal on the tangential x-ray crystal spectrometer.By selecting appropriate crystals with similar Bragg angles, plasma temperature in the range of 0.5 keV≤Te≤10 keV and rotation can be diagnosed based on the He-like and H-like argon spectra. However, due to the added complexity in the two-crystal assembly in which the spectra might be diffracted by two crystals, some additional impurity lines were identified. For example,tungsten(W) lines in different ionization states were diffracted by the He-like and H-like crystal.Additional molybdenum(Mo) lines in the wavelength range of He-like and H-like argon spectra lines were also summarized. The existence of these additional lines caused the fitted temperature to be different from the true values. This paper presents the identified lines through a comparison with available database, which should be included in the fitting procedure.