期刊文献+
共找到507篇文章
< 1 2 26 >
每页显示 20 50 100
A remote sensing system of vehicle emissions based on tunable diode laser technology 被引量:3
1
作者 ZENG Jun GUO Hua-fang HU Yue-ming 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2006年第1期154-157,共4页
As being an effective real-time method of monitoring vehicle emissions on-road, a remote sensing system based on the tunable diode laser (TDL) technology was presented, and the key technologies were discussed. A fie... As being an effective real-time method of monitoring vehicle emissions on-road, a remote sensing system based on the tunable diode laser (TDL) technology was presented, and the key technologies were discussed. A field test in Guangzhou(Guangdong, China) was performed and was found that the factors, such as slope, instantaneous speed and acceleration, had significant influence on the detectable rate of the system. Based on the results, the proposal choice of testing site was presented. 展开更多
关键词 remote sensing tunable diode laser vehicle emission detectable rate
在线阅读 下载PDF
Measurements of argon metastable density using the tunable diode laser absorption spectroscopy in Ar and Ar/O2 被引量:1
2
作者 Dao-Man Han Yong-Xin Liu +3 位作者 Fei Gao Wen-Yao Liu Jun Xu You-Nian Wang 《Chinese Physics B》 SCIE EI CAS CSCD 2018年第6期298-306,共9页
Densities of Ar metastable states 1s5 and 1s3 are measured by using the tunable diode laser absorption spectroscopy(TDLAS) in Ar and Ar/O2 mixture dual-frequency capacitively coupled plasma(DF-CCP). We investigate... Densities of Ar metastable states 1s5 and 1s3 are measured by using the tunable diode laser absorption spectroscopy(TDLAS) in Ar and Ar/O2 mixture dual-frequency capacitively coupled plasma(DF-CCP). We investigate the effects of high-frequency(HF, 60 MHz) power, low-frequency(LF, 2 MHz) power, and working pressure on the density of Ar metastable states for three different gas components(0%, 5%, and 10% oxygen mixed in argon). The dependence of Ar metastable state density on the oxygen content is also studied at different working pressures. It is found that densities of Ar metastable states in discharges with different gas components exhibit different behaviors as HF power increases. With the increase of HF power, the metastable density increases rapidly at the initial stage, and then tends to be saturated at a higher HF power. With a small fraction(5% or 10%) of oxygen added in argon plasma, a similar change of the Ar metastable density with HF power can be observed, but the metastable density is saturated at a higher HF power than in the pure argon discharge. In the DF-CCP, the metastable density is found to be higher than in a single frequency discharge, and has weak dependence on LF power. As working pressure increases, the metastable state density first increases and then decreases,and the pressure value, at which the density maximum occurs, decreases with oxygen content increasing. Besides, adding a small fraction of oxygen into argon plasma will significantly dwindle the metastable state density as a result of quenching loss by oxygen molecules. 展开更多
关键词 argon metastable states tunable diode laser absorption spectroscopy capacitively coupled plasmas
原文传递
Development of 2D Temperature and Concentration Measurement Method Using Tunable Diode Laser Absorption Spectroscopy 被引量:7
3
作者 Yoshihiro Deguchi Daisuke Yasui Akira Adachi 《Journal of Mechanics Engineering and Automation》 2012年第9期543-549,共7页
Exhaust gas temperature is an important factor in NOx, THC and PM emissions of engines. Especially 2D temperature and concentration distribution plays an important role for the engine efficiency. A thermocouple is int... Exhaust gas temperature is an important factor in NOx, THC and PM emissions of engines. Especially 2D temperature and concentration distribution plays an important role for the engine efficiency. A thermocouple is intrinsically a point temperature measurement method and noncontact 2D temperature distribution cannot be attained by thermocouples. Recently, as a measurement technique with high sensitivity and high response, laser diagnostics has been developed and applied to the actual engine combustions. With these engineering developments, transient phenomena such as start-ups and load changes in engines have been gradually elucidated in various conditions. In this study, the theoretical and experimental research has been conducted in order to develop the noncontact and fast response 2D temperature and concentration distribution measurement method. The method is based on a Computed Tomography (CT) method using absorption spectra of water vapor at 1388 nm. It has been demonstrated that the method has been successfully applied to engine exhausts to measure 2D temperature distributions. 展开更多
关键词 2D temperature measurement tunable diode laser absorption spectroscopy CT (computed tomography) engine exhausts.
在线阅读 下载PDF
Tunable Single-Passband Microwave Photonic Filter Based on Sagnac Loop and Fabry-Perot Laser Diode 被引量:1
4
作者 徐恩明 张祖兴 李培丽 《Chinese Physics Letters》 SCIE CAS CSCD 2017年第1期52-55,共4页
A tunable single-passband microwave photonic filter is proposed and demonstrated, based on a laser diode (LD) array with multiple optical carriers and a Fabry-Perot (F-P) laser diode. Multiple optical carriers in conj... A tunable single-passband microwave photonic filter is proposed and demonstrated, based on a laser diode (LD) array with multiple optical carriers and a Fabry-Perot (F-P) laser diode. Multiple optical carriers in conjunction with the F-P LD will realize a filter with multiple passbands. By adjusting the wavelengths of the multiple optical carriers, multiple passbands are merged into a single passband with a broadened bandwidth. By varying the number of the optical carrier, the bandwidth can be adjusted. The central frequency can be tuned by adjusting the wavelength of the multiple optical carriers simultaneously. A single-passband filter implemented by two optical carriers is experimentally demonstrated. 展开更多
关键词 LD tunable Single-Passband Microwave Photonic Filter Based on Sagnac Loop and Fabry-Perot laser diode
原文传递
A 1550-nm linearly tunable continuous wave single-mode external cavity diode laser based on a single-cavity all-dielectric thin-film Fabry Pérot filter
5
作者 肖啸 鲁远甫 +1 位作者 于峰崎 金雷 《Chinese Physics B》 SCIE EI CAS CSCD 2013年第7期533-541,共9页
A 1550-nm linearly tunable continuous wave (CW) single-mode external cavity diode laser (ECDL) based on a singlecavity all-dielectric thin-film Fabry-Pérot filter (s-AFPF) is proposed and realized in this p... A 1550-nm linearly tunable continuous wave (CW) single-mode external cavity diode laser (ECDL) based on a singlecavity all-dielectric thin-film Fabry-Pérot filter (s-AFPF) is proposed and realized in this paper. Its internal optical components as well as their operation mechanisms are introduced first, and then its longitudinal mode output characteristic is theoretically analyzed. Afterwards, we set up the experimental platform for the output characteristic measurement of this tunable ECDL; under different experimental conditions, we execute accurate and real-time measurements for the output central wavelength, output optical power, output longitudinal mode distribution, and the line-width of the tunable ECDL in its tuning process. By summing up the optimal experimental condition from the measured data, we obtain the optimal tunable ECDL relevant parameters: the tunable ECDL has a linear mode-hop-free wavelength tuning region of 1547.203 nm-1552.426 nm, a stable output optical power in the range of 40 μW-50 μW, and a stable output longitudinal mode distribution of a single longitudinal mode with a line-width in the range of 100 MHz-150 MHz. This tunable ECDL can be used in environmental gas monitoring, atomic and molecular laser spectroscopy research, precise measurements, and so on. 展开更多
关键词 thin-film optical properties tunable external cavity diode laser laser spectroscopy
原文传递
Generation of Tunable Amplitude-Squeezed Light by Injection Locking of a Laser Diode
6
作者 WANG Jun-Min HE Ling-Xiang +2 位作者 ZHANG Tian-Cai XIE Chang-De PENG Kun-Chi 《Chinese Physics Letters》 SCIE CAS CSCD 2000年第6期422-424,共3页
Tunable amplitude squeezing around the D_(2)line of cesium has been experimentally accomplished at room temperature in a quantum-well laser diode with light injection from a single-mode distributed Bragg-Reflector las... Tunable amplitude squeezing around the D_(2)line of cesium has been experimentally accomplished at room temperature in a quantum-well laser diode with light injection from a single-mode distributed Bragg-Reflector laser diode.While the master laser frequency is tuned,amplitude squeezing of the output light from the slave laser can be maintained at about 0.9dB throughout a tunabIe range of~l.7 GHz around the cesium D_(2)line. 展开更多
关键词 tunable laser diode
原文传递
Application of Tunable Diode Laser Absorption Spectroscopy with Optical Hollow Fiber to Engine Exhaust Gas Measurement
7
作者 Akira Adachi Yoshihiro Deguchi Shinichirou Konishi 《Journal of Mechanics Engineering and Automation》 2012年第11期656-662,共7页
In recent years, tighter regulation has been already enforced on harmful substances such as NOx, CO, and particles. Considering the above situation, it is important to monitor controlling factors of engine systems in ... In recent years, tighter regulation has been already enforced on harmful substances such as NOx, CO, and particles. Considering the above situation, it is important to monitor controlling factors of engine systems in order to improve efficiencies of their operations. As to car engines, an increasing concern in environmental issues such as air pollution, global warming and petroleum depletion has helped drive researches into various ways. Laser diagnostics has been applied to measure species concentration in the actual industrial fields. However there are several challenges to proceed in applying laser diagnostics to practical application. Especially stability of the measurement system is one of the most difficult issues. The purpose of this research is the development of a prompt measurement technique which can be applicable to various engine conditions. The Tunable Diode Laser Absorption Spectroscopy (TDLAS) using the hollow fiber has been developed to satisfy above requirements. By using a hollow fiber, misalignment of an optical axis and vulnerability of measurement environment such as vibration can be greatly reduced with sensitive and fast response features. It was demonstrated that this method can be applicable to measure gas compositions in engine exhaust with a range of millisecond response time. A sensitive method using tunable UV diode laser absorption spectroscopy was also discussed to detect NOx in exhausts. 展开更多
关键词 tunable diode laser absorption spectroscopy optical hollow fiber exhaust gas concentration measurement.
在线阅读 下载PDF
Dynamic thermal modeling and parameter identification for a monolithic laser diode module
8
作者 李金义 杜振辉 +1 位作者 马艺闻 徐可欣 《Chinese Physics B》 SCIE EI CAS CSCD 2013年第3期317-322,共6页
We improved the thermal equivalent-circuit model of the laser diode module(LDM) to evaluate its thermal dynamic properties and calculate the junction temperature of the laser diode with a high accuracy.The thermal p... We improved the thermal equivalent-circuit model of the laser diode module(LDM) to evaluate its thermal dynamic properties and calculate the junction temperature of the laser diode with a high accuracy.The thermal parameters and the transient junction temperature of the LDM are modeled and obtained according to the temperature of the thermistor integrated in the module.Our improved thermal model is verified indirectly by monitoring the emission wavelength of the laser diode against gas absorption lines,and several thermal parameters are obtained with the temperature uncertainty of 0.01 K in the thermal dynamic process. 展开更多
关键词 laser diode module dynamic thermal modeling thermal time constant tunable diode laser absorption spectroscopy(TDLAS)
原文传递
Diode-pumped Kerr-lens mode-locked Ti: sapphire laser with broad wavelength tunability
9
作者 Han Liu Geyang Wang +6 位作者 Ke Yang Renzhu Kang Wenlong Tian Dacheng Zhang Jiangfeng Zhu Hainian Han Zhiyi Wei 《Chinese Physics B》 SCIE EI CAS CSCD 2019年第9期232-236,共5页
We report a direct blue-diode-pumped wavelength tunable Kerr-lens mode-locked Ti: sapphire laser.Central wavelength tunability as broad as 89 nm(736-825 nm) is achieved by adjusting the insertion of the prism.Pulses a... We report a direct blue-diode-pumped wavelength tunable Kerr-lens mode-locked Ti: sapphire laser.Central wavelength tunability as broad as 89 nm(736-825 nm) is achieved by adjusting the insertion of the prism.Pulses as short as 17 fs are generated at a central wavelength of 736 nm with an average output power of 31 mW.The maximum output power is 46.8 mW at a central wavelength of 797 nm with a pulse duration of 46 fs. 展开更多
关键词 blue-diode pump Ti: sapphire WAVELENGTH tunable Kerr-lens MODE-LOCKED laser
原文传递
CW DFB-QCL-based system for H_(2)O_(2)detection using multi-pass tunable diode laser absorption spectroscopy
10
作者 Chao Liu Mengmeng Xu +6 位作者 Miao Hu Sunqiang Pan Haiyang Qi Sumei Liu Haozhen Li Chong Liu Yaokun Shang 《Chinese Optics Letters》 2025年第8期143-149,共7页
A hydrogen peroxide[H_(2)O_(2)]detection system is demonstrated with multi-pass tunable diode laser absorption spectroscopy using a 75 m Herriott absorption cell.The system utilizes an~8μm continuous wave distributed... A hydrogen peroxide[H_(2)O_(2)]detection system is demonstrated with multi-pass tunable diode laser absorption spectroscopy using a 75 m Herriott absorption cell.The system utilizes an~8μm continuous wave distributed feedback quantum cascade laser[CW DFB-QCL]targeting a prominent H_(2)O_(2)line at 1253.1 cm^(-1)within the fundamental absorption band.A wavelength modulation spectroscopy with the first harmonic normalized second harmonic[WMS-2f/1f]detection method is employed to eliminate laser light intensity fluctuations.Calibration of the system is conducted by means of chemical titration to establish the correlation between the peak value of the 2f/1f signal and H_(2)O_(2)concentration.An Allan-Werle deviation analysis shows that a minimum detection limit[MDL]of 2.9 ppb[1 ppb=10^(-9)]for H_(2)O_(2)is achieved with an average time of 147 s.To the best of our knowledge,this is the lowest detection limit for H_(2)O_(2)at the wavenumber of 1253.1 cm^(-1).The system exhibits robust resistance to interference from other gases,especially water vapor[H_(2)O],making it suitable for measuring the residual concentration of H_(2)O_(2)post-sterilization and the concentration of H_(2)O_(2)in the atmosphere. 展开更多
关键词 mid-infrared range multi-pass tunable diode laser absorption spectroscopy quantum cascade laser wavelength modulation spectroscopy
原文传递
A high sensitivity spectrometer with tunable diode laser for ambient methane monitoring 被引量:11
11
作者 阚瑞峰 刘文清 +5 位作者 张玉钧 刘建国 王敏 陈东 陈玖英 崔益本 《Chinese Optics Letters》 SCIE EI CAS CSCD 2007年第1期54-57,共4页
Tunable diode laser absorption spectroscopy (TDLAS) has been widely employed in atmospheric trace gases detection. In the measurement of these trace gases, harmonic detection combined with a multi-pass white cell co... Tunable diode laser absorption spectroscopy (TDLAS) has been widely employed in atmospheric trace gases detection. In the measurement of these trace gases, harmonic detection combined with a multi-pass white cell could remarkably enhance the detection sensitivity. In this paper, a portable TDLAS system built specifically for long time monitoring methane in the atmosphere is introduced. The detection limit is below 100 ppb that is enough for the monitoring of ambient methane, and the long time monitoring results obtained in Beijing are given, which is well coincident with that of the Fourier transform infrared (FTIR) spectroscopy. 展开更多
关键词 THAN TDLAS A high sensitivity spectrometer with tunable diode laser for ambient methane monitoring HIGH
原文传递
Fast Tunable Wavelength Sources Based on the Laser Diode Array
12
作者 Sung-Chan Cho Hyun Ha Hong Byoung-Whi Kim 《光学学报》 EI CAS CSCD 北大核心 2003年第S1期483-484,共2页
We report a demonstration of a fast wavelength tunable source (TWS) based on the laser diode array coupled to the arrayed waveguide grating (AWG) multiplexer. The switching and optical characteristics of TWS make it a... We report a demonstration of a fast wavelength tunable source (TWS) based on the laser diode array coupled to the arrayed waveguide grating (AWG) multiplexer. The switching and optical characteristics of TWS make it a candidate for implementing the wavelength-division space switch fabric for an optical packet/burst switching. 展开更多
关键词 AWG as for Fast tunable Wavelength Sources Based on the laser diode Array on THAN be mode LD MWL of
原文传递
A Tunable Dual-Wavelength Fiber Ring Laser with a Fabry-Perot Laser Diode in an External Injection Seeding Scheme
13
作者 Hong-Yih Tseng Sien Chi 《光学学报》 EI CAS CSCD 北大核心 2003年第S1期477-478,共2页
A tunable dual-wavelength fiber ring laser with a Fabry-Perot laser diode is proposed and demonstrated. The dual-wavelength outputs have the optical side-mode-suppression-ratio (SMSR) over 31 dB. The wavelength tuning... A tunable dual-wavelength fiber ring laser with a Fabry-Perot laser diode is proposed and demonstrated. The dual-wavelength outputs have the optical side-mode-suppression-ratio (SMSR) over 31 dB. The wavelength tuning range can be up to 9 run. 展开更多
关键词 LD of as in FP EDF A tunable Dual-Wavelength Fiber Ring laser with a Fabry-Perot laser diode in an External Injection Seeding Scheme with
原文传递
基于中红外激光吸收光谱技术的低浓度SO_(3)检测系统
14
作者 尤晨昱 俞峰苹 邓丽萍 《自动化技术与应用》 2026年第1期79-82,90,共5页
三氧化硫(SO_(3))作为常见的烟气排放污染物,对生态环境和人类健康产生了严重的影响。SO_(3)化学性质活泼,在排放烟气中浓度相对较低,实现SO_(3)的在线监测一直是个挑战。基于量子级联激光器的可调谐二极管激光吸收光谱技术(QCL-TDLAS)... 三氧化硫(SO_(3))作为常见的烟气排放污染物,对生态环境和人类健康产生了严重的影响。SO_(3)化学性质活泼,在排放烟气中浓度相对较低,实现SO_(3)的在线监测一直是个挑战。基于量子级联激光器的可调谐二极管激光吸收光谱技术(QCL-TDLAS),研制了适用于燃煤电厂等工业烟气的低浓度SO_(3)检测系统。本系统在压力30 kPa、测量池温度553 K的实验工况下对SO_(2)催化氧化制取的SO_(3)进行连续测量,SO_(3)气体浓度与吸收信号的二次谐波峰值线性拟合相关度达到0.993,SO_(3)的检测下限可达到0.175×10^(-6)。 展开更多
关键词 检测 三氧化硫 量子级联激光器 可调谐二极管 激光吸收光谱技术 波长调制法
在线阅读 下载PDF
An Innovative Gas Sensor with On-Chip Reference Using Monolithic Twin Laser 被引量:6
15
作者 张永刚 田招兵 +5 位作者 张晓钧 顾溢 李爱珍 祝向荣 郑燕兰 刘盛 《Chinese Physics Letters》 SCIE CAS CSCD 2007年第10期2839-2841,共3页
An innovative gas sensor with on-chip reference using a monolithic twin laser is proposed. In this sensor a monolithic twin laser generates two closer laser beams with slight different wavelengths alternatively, one p... An innovative gas sensor with on-chip reference using a monolithic twin laser is proposed. In this sensor a monolithic twin laser generates two closer laser beams with slight different wavelengths alternatively, one photodiode is used to catch both absorption and reference signals by time division multiplexing. The detection of nitrous oxide adopting this scheme using a 2.1 I^m antimonide laser and an InGaAs photodiode has been demonstrated experimentally with detection limit below i ppm. Using this on chip reference scheme the fluctuations from the optical path and devices can be compensated effectively; the sensor system is simplified distinctly. 展开更多
关键词 QUANTUM CASCADE laserS 2.1 MU-M diode-laserS SEMICONDUCTOR-laserS MQWlaserS ANTIMONIDE TUNABILITY
原文传递
Laser absorption spectroscopy for high temperature H_2O time-history measurement at 2.55 μm during oxidation of hydrogen
16
作者 Yu-Dan Gou De-Xiang Zhang +3 位作者 Yi-Jun Wang Chang-Hua Zhang Ping Li Xiang-Yuan Li 《Chinese Physics B》 SCIE EI CAS CSCD 2018年第7期376-381,共6页
Concentration time-histories of H20 were measured behind reflected shock waves during hydrogen combustion. Experiments were conducted at temperatures of 1117-1282 K, the equivalence ratios of 0.5 and 0.25, and a press... Concentration time-histories of H20 were measured behind reflected shock waves during hydrogen combustion. Experiments were conducted at temperatures of 1117-1282 K, the equivalence ratios of 0.5 and 0.25, and a pressure at 2 atm using a mixture of H2/O2 highly diluted with argon. H2O was monitored using tunable mid-infrared diode laser absorption at 2.55 μm (3920.09 cm-1). These time-histories provide kinetic targets to test and refine reaction mechanisms for hydrogen. Comparisons were made with the predictions of four detailed kinetic mechanisms published in the last four years. Such comparisons of H2O concentration profiles indicate that the AramcoMech 2.0 mechanism yields the best agreement with the experimental data, while CRECK, San Diego, and HP-Mech mechanisms show significantly poor predictions. Reaction pathway analysis for hydrogen oxidation indicates that the reaction H + OH + M = H20 + M is the key reaction for controlling the H2O formation by hydrogen oxidation. It is inferred that the discrepancy of the conversion percentage from H to H20 among these four mechanisms induces the difference of performance on H2O time-history predictions. This work demonstrates the potential of time-history measurement for validation of large reaction mechanisms. 展开更多
关键词 tunable diode laser absorption spectroscopy H20 time-history profile combustion process reac- tion mechanism
原文传递
基于一维空洞卷积的甲烷浓度实时检测装置设计
17
作者 阚玲玲 叶炀 +1 位作者 苗凯 梁洪卫 《实验技术与管理》 北大核心 2025年第1期191-197,共7页
可调谐激光吸收光谱(TDLAS)技术需要人工筛选二次谐波后拟合数据,且人为因素会影响拟合曲线的预测结果,因此该文设计了一种基于空洞卷积的甲烷浓度检测装置。首先,利用一维空洞卷积提取二次谐波信号特征;其次,利用反残差模块提高模型收... 可调谐激光吸收光谱(TDLAS)技术需要人工筛选二次谐波后拟合数据,且人为因素会影响拟合曲线的预测结果,因此该文设计了一种基于空洞卷积的甲烷浓度检测装置。首先,利用一维空洞卷积提取二次谐波信号特征;其次,利用反残差模块提高模型收敛速度,减少训练时间;再次,加入宽卷积核感受野模块,在保证检测准确率的前提下扩大感受野,减少模型参数;最后,将模型部署在Jetson Nano上实时检测甲烷浓度。实验结果表明,该方法检测准确率为99.89%,模型参数为12768个。与其他模型相比,该模型检测精度高、参数量少、实时性强,适用于实验室甲烷浓度实时检测。 展开更多
关键词 可调谐激光吸收光谱 JetsonNano 深度学习 轻量化 实验装置
在线阅读 下载PDF
吸收光谱线二次谐波的频率分解和SG滤波复合降噪
18
作者 涂兴华 栾小晨 王战 《光谱学与光谱分析》 北大核心 2025年第5期1209-1216,共8页
针对微弱气体吸收光谱线的二次谐波信号检测过程中存在的噪声干扰问题,提出利用频率分解(FD)和Savitzky-Golay滤波(SG滤波)相结合方法(简记为FD-SG滤波)对含噪信号进行降噪。频率分解是一种用于分解复杂信号的数学方法,其优点是能够自... 针对微弱气体吸收光谱线的二次谐波信号检测过程中存在的噪声干扰问题,提出利用频率分解(FD)和Savitzky-Golay滤波(SG滤波)相结合方法(简记为FD-SG滤波)对含噪信号进行降噪。频率分解是一种用于分解复杂信号的数学方法,其优点是能够自主选择分解个数或者采用非递归方式求解。SG滤波能够对成组的数据进行处理,在维持信号变化趋势和宽度的同时提高数据的精准度。首先对含噪信号进行频率分解,再进行SG滤波二次降噪处理,最后将滤波后的有效层分量进行重构,得到降噪后的二次谐波信号。讨论分析了频率分解后各层分量的分布情况,验证有效信号主要分布在第一层分量内,并且仍会含有残余噪声;通过构建调节因子P选取最优的SG滤波框长,使得有效层残留噪声得到有效去除。针对空气中的CO_(2),采用1578.222 nm的吸收光谱线进行实验,结果显示二次谐波信号中存在大量噪声,尤其在扫描周期交界处出现大尖峰噪声。通过拟合曲线扣除处理和频率分解,发现大尖峰噪声未明显减弱。随后结合SG滤波处理并比较了二次谐波与大尖峰峰值的关系,结果表明SG滤波能够有效减弱大尖峰噪声,选择合适滤波框长即可得到较为理想的降噪效果。在对人体呼出CO_(2)的二次谐波信号进行检测时,发现吹气引起的湍流导致信号幅值增大并抖动,通过FD-SG滤波处理成功抑制了噪声,恢复出较为平滑的二次谐波信号。验证了该算法对实际微弱气体检测的二次谐波信号降噪的性能,在实现噪声抑制及大尖峰结构噪声的减弱方面表现出较突出的优势。这对微弱气体检测方面提高信号质量和系统精度有积极意义。 展开更多
关键词 可调谐二极管激光吸收光谱 二次谐波 波形恢复 调节因子
在线阅读 下载PDF
瓦斯隧道抽采钻孔瓦斯体积分数实时计量模型设计及优化研究
19
作者 刘勇 余大炀 +2 位作者 张慧栋 陈长江 何岸 《隧道建设(中英文)》 北大核心 2025年第6期1102-1111,共10页
钻孔孔口瓦斯体积分数的实时精准测量是实现瓦斯隧道智能化治理的关键。目前常用的可调谐半导体激光吸收光谱技术(TDLAS)在瓦斯隧道复杂环境中存在低体积分数检测精度不足等问题。为解决上述问题,构建一种集成波长调制光谱(WMS)与重心... 钻孔孔口瓦斯体积分数的实时精准测量是实现瓦斯隧道智能化治理的关键。目前常用的可调谐半导体激光吸收光谱技术(TDLAS)在瓦斯隧道复杂环境中存在低体积分数检测精度不足等问题。为解决上述问题,构建一种集成波长调制光谱(WMS)与重心拉格朗日插值补偿算法的TDLAS测量系统,并结合钻孔气体组分、环境压力与温度变化对测量误差进行建模修正,提升系统在动态钻孔环境下的测量精度与稳定性。通过标准气体试验对系统性能进行验证,主要研究结论如下:1)基于Beer-Lambert定律和HITRAN数据库参数,建立瓦斯体积分数TDLAS反演模型,明确吸收谱线型函数与线强度是影响测量精度的关键因素,分析表明钻孔环境下采用Lorentz函数描述谱线展宽更为合理。2)针对温度与压力变化引起的谱线偏移问题,提出基于重心加权的拉格朗日插值补偿算法,实现了非稳态条件下的体积分数高精度修正,具备良好的数值稳定性与适应性。3)通过0.5%和4.5%体积分数标准瓦斯气体在0~40℃内的温度扰动试验,验证了所提补偿方法可将系统最大测量误差控制在0.5%以内,显著优于未补偿状态。4)提出的测量系统实现了钻孔单孔瓦斯体积分数的高精度、动态监测,具备良好的环境适应性和工程应用潜力。 展开更多
关键词 抽采钻孔 瓦斯隧道 瓦斯体积分数 TDLAS技术 补偿算法
在线阅读 下载PDF
激光吸收光谱痕量乙炔检测方法研究 被引量:2
20
作者 李橙橙 曹旺 +1 位作者 万元 温和 《中国测试》 北大核心 2025年第3期75-80,86,共7页
针对现有的正交型锁相放大器在可调谐激光二极管吸收光谱吸收信号中存在检测下限差、稳定性差等问题,该文提出基于插值离散傅里叶变换的相位测量与数字锁相放大器的光谱吸收信号检测方法,可实现低浓度气体的高精度检测。为验证该方法的... 针对现有的正交型锁相放大器在可调谐激光二极管吸收光谱吸收信号中存在检测下限差、稳定性差等问题,该文提出基于插值离散傅里叶变换的相位测量与数字锁相放大器的光谱吸收信号检测方法,可实现低浓度气体的高精度检测。为验证该方法的有效性,该文选择1532.8 nm作为检测中心波长,设计适用于变压器绝缘油中溶解乙炔气体检测的可调谐激光二极管吸收光谱系统。结果表明,当测量2μL/L乙炔气体时,该方法比传统正交型锁相放大器测量准确性提高26.76%。该测量结果也比传统方法更稳定,且计算量更小。此外,该文设计系统实现变压器绝缘油中溶解乙炔检测时,0.22μL/L以上乙炔浓度的测量误差小于30%,0.12μL/L乙炔浓度的测量偏差小于±0.5μL/L,满足电力变压器油中溶解乙炔的检测需求。 展开更多
关键词 可调谐激光二极管吸收光谱 谐波检测 数字锁相放大器 插值离散傅里叶变换
在线阅读 下载PDF
上一页 1 2 26 下一页 到第
使用帮助 返回顶部