To study the seismic behavior of high strength concrete fi lled double-tube(CFDT) columns,each consisting of an external square steel tube and an internal circular steel tube,quasi-static tests on eight CFDT column sp...To study the seismic behavior of high strength concrete fi lled double-tube(CFDT) columns,each consisting of an external square steel tube and an internal circular steel tube,quasi-static tests on eight CFDT column specimens were conducted.The test variables included the width-to-thickness ratio(β1) and the area ratio(β2) of the square steel tube,the wall thickness of the circular steel tube,and the axial force(or the axial force ratio) applied to the CFDT columns.The test results indicate that for CFDT columns with a square steel tube with β1 of 50.1 and 24.5,local buckling of the specimen was found at a drift ratio of 1/150 and 1/50,respectively.The lateral force-displacement hysteretic loops of all specimens were plump and stable.Reducing the width-to-thickness ratio of the square steel tube,increasing its area ratio,or increasing the wall thickness of the internal circular steel tube,led to an increased fl exural strength and deformation capacity of the specimens.Increasing the design value of the axial force ratio from 0.8 to 1.0 may increase the fl exural strength of the specimens,while it may also decrease the ultimate deformation capacity of the specimen with β1 of 50.1.展开更多
The behavior of square-tubed reinforced concrete (STRC) short columns subjected to axial compression was studied in detail with an accurate nonlinear finite element model (FEM) . Different width to thickness ratios (D...The behavior of square-tubed reinforced concrete (STRC) short columns subjected to axial compression was studied in detail with an accurate nonlinear finite element model (FEM) . Different width to thickness ratios (D/t = 50 150) of the steel tube and the compressive strength of concrete (C80 and C50) were adopted in this research. The axial load strength,steel tube strain and load-shortening response were determined from FEM and the analysis results from FEM were compared with those from experiment. The analysis and test results indicate that the concrete strength little affectes the confinement of the steel tube on the concrete. The transverse stress of the tube at the axial load point increases with the increment in the width to thickness ratio. Based on the results from FEM and experiment,a formula for the prediction of the axial load strength was proposed in this paper.展开更多
基金the National Natural Science Foundation of China under Grants Nos.51261120377 and 51008173
文摘To study the seismic behavior of high strength concrete fi lled double-tube(CFDT) columns,each consisting of an external square steel tube and an internal circular steel tube,quasi-static tests on eight CFDT column specimens were conducted.The test variables included the width-to-thickness ratio(β1) and the area ratio(β2) of the square steel tube,the wall thickness of the circular steel tube,and the axial force(or the axial force ratio) applied to the CFDT columns.The test results indicate that for CFDT columns with a square steel tube with β1 of 50.1 and 24.5,local buckling of the specimen was found at a drift ratio of 1/150 and 1/50,respectively.The lateral force-displacement hysteretic loops of all specimens were plump and stable.Reducing the width-to-thickness ratio of the square steel tube,increasing its area ratio,or increasing the wall thickness of the internal circular steel tube,led to an increased fl exural strength and deformation capacity of the specimens.Increasing the design value of the axial force ratio from 0.8 to 1.0 may increase the fl exural strength of the specimens,while it may also decrease the ultimate deformation capacity of the specimen with β1 of 50.1.
基金Sponsored by the National Natural Science Foundation of China (Grant No. 50708027)the National Key Technology Research and Development Program of China (Grant No.2006BAJ01B02)
文摘The behavior of square-tubed reinforced concrete (STRC) short columns subjected to axial compression was studied in detail with an accurate nonlinear finite element model (FEM) . Different width to thickness ratios (D/t = 50 150) of the steel tube and the compressive strength of concrete (C80 and C50) were adopted in this research. The axial load strength,steel tube strain and load-shortening response were determined from FEM and the analysis results from FEM were compared with those from experiment. The analysis and test results indicate that the concrete strength little affectes the confinement of the steel tube on the concrete. The transverse stress of the tube at the axial load point increases with the increment in the width to thickness ratio. Based on the results from FEM and experiment,a formula for the prediction of the axial load strength was proposed in this paper.