The cascaded H-bridge(CHB)multilevel inverter has become one of the most widely used PV inverter topologies due to its high voltage processing capability and high quality output power.Grid-connected PV system due to e...The cascaded H-bridge(CHB)multilevel inverter has become one of the most widely used PV inverter topologies due to its high voltage processing capability and high quality output power.Grid-connected PV system due to external conditions such as PV panel shading,PV component damage,can lead to PV output power imbalance,triggering the system over-modulation phenomenon,which in turn leads to grid-connected current waveform distortion.To this end,an improved power balance control strategy is proposed in this paper.Firstly,according to the different modulation ratios of each H-bridge module,a suitable harmonic injection method is used to keep the peak value of the modulating waveform always at 1;then an inverse triangular trapezoidal waveform is injected to optimize the modulating waveform,which further improves the output voltage waveform,reduces the THD value of the grid-connected currents,and maintains the stability of power inside the CHB system.Purpose.Simulation verifies the effectiveness and feasibility of this power balance control strategy.展开更多
Internal and external meshes are two of primary excitation sources which induce vibration while double-helical planetary gear sets are in transmission. Based on the analysis of tooth movement principle,three cases of ...Internal and external meshes are two of primary excitation sources which induce vibration while double-helical planetary gear sets are in transmission. Based on the analysis of tooth movement principle,three cases of mesh stiffness are derived via investigating the length of action lines,and catalogued in terms of β < β0,β = β0and β > β_0. The simulation demonstrates mesh stiffness between gear pairs performs as a trapezoid waveform( TW) and changes along with the line of action simultaneously,total mesh stiffness comes from the superposition of each engaged gear. While governing equations of motion contained 16 DOFs( degree of freedom) are constructed and effectively solved through the combination of numerical approaches. Comparing with sinusoidal waveform mesh stiffness( SW),the results show that dynamical factors and perturbation under the excitation of TW( β < β_0) are greater and remarkable than that from SW,with respect to the mean dynamic factors about 1. 51 and 1. 28,respectively. The fluctuation response between ring- planet( R- P) is stronger than sun-planet( S-P) which is also validated by both approach studies,frequency spectra analyses identifies larger distinct rotational resonance and more frequencies under TW excitation.展开更多
基金supported by the National Natural Science Foundation of China,Regional Science Foundation Project,52367009,Study on Bow Net Dynamics Modeling and Coupling Smoothness of High speed AC Rigid Network in the Long Tunnel Section of Sichuan Tibet Railway.
文摘The cascaded H-bridge(CHB)multilevel inverter has become one of the most widely used PV inverter topologies due to its high voltage processing capability and high quality output power.Grid-connected PV system due to external conditions such as PV panel shading,PV component damage,can lead to PV output power imbalance,triggering the system over-modulation phenomenon,which in turn leads to grid-connected current waveform distortion.To this end,an improved power balance control strategy is proposed in this paper.Firstly,according to the different modulation ratios of each H-bridge module,a suitable harmonic injection method is used to keep the peak value of the modulating waveform always at 1;then an inverse triangular trapezoidal waveform is injected to optimize the modulating waveform,which further improves the output voltage waveform,reduces the THD value of the grid-connected currents,and maintains the stability of power inside the CHB system.Purpose.Simulation verifies the effectiveness and feasibility of this power balance control strategy.
基金Sponsored by the National High-tech R&D Program of China(Grant No.2009AA04Z404)
文摘Internal and external meshes are two of primary excitation sources which induce vibration while double-helical planetary gear sets are in transmission. Based on the analysis of tooth movement principle,three cases of mesh stiffness are derived via investigating the length of action lines,and catalogued in terms of β < β0,β = β0and β > β_0. The simulation demonstrates mesh stiffness between gear pairs performs as a trapezoid waveform( TW) and changes along with the line of action simultaneously,total mesh stiffness comes from the superposition of each engaged gear. While governing equations of motion contained 16 DOFs( degree of freedom) are constructed and effectively solved through the combination of numerical approaches. Comparing with sinusoidal waveform mesh stiffness( SW),the results show that dynamical factors and perturbation under the excitation of TW( β < β_0) are greater and remarkable than that from SW,with respect to the mean dynamic factors about 1. 51 and 1. 28,respectively. The fluctuation response between ring- planet( R- P) is stronger than sun-planet( S-P) which is also validated by both approach studies,frequency spectra analyses identifies larger distinct rotational resonance and more frequencies under TW excitation.