As the penetration rate of distributed energy increases,the transient power angle stability problem of the virtual synchronous generator(VSG)has gradually become prominent.In view of the situation that the grid impeda...As the penetration rate of distributed energy increases,the transient power angle stability problem of the virtual synchronous generator(VSG)has gradually become prominent.In view of the situation that the grid impedance ratio(R/X)is high and affects the transient power angle stability of VSG,this paper proposes a VSG transient power angle stability control strategy based on the combination of frequency difference feedback and virtual impedance.To improve the transient power angle stability of the VSG,a virtual impedance is adopted in the voltage loop to adjust the impedance ratio R/X;and the PI control feedback of the VSG frequency difference is introduced in the reactive powervoltage link of theVSGto enhance the damping effect.Thesecond-orderVSGdynamic nonlinearmodel considering the reactive power-voltage loop is established and the influence of different proportional integral(PI)control parameters on the system balance stability is analyzed.Moreover,the impact of the impedance ratio R/X on the transient power angle stability is presented using the equal area criterion.In the simulations,during the voltage dips with the reduction of R/X from 1.6 to 0.8,Δδ_(1)is reduced from 0.194 rad to 0.072 rad,Δf_(1)is reduced from 0.170 to 0.093 Hz,which shows better transient power angle stability.Simulation results verify that compared with traditional VSG,the proposedmethod can effectively improve the transient power angle stability of the system.展开更多
Virtual synchronous control has been widely studied for the advantages of emulating inertia for voltage source converters (VSCs). A constant dc-link voltage is usually assumed in existing literature to estimate transi...Virtual synchronous control has been widely studied for the advantages of emulating inertia for voltage source converters (VSCs). A constant dc-link voltage is usually assumed in existing literature to estimate transient stability of virtual synchronous generators (VSGs). However, actual power supply in the dc-side of VSGs is limited and different dc-link voltage controllers are needed to achieve power balance between DC side and AC side. Addition of dc-link voltage controller has great influence on transient behavior of VSGs, which has not been investigated by previous research. To fill this gap, this paper gives insights into the effect of dc-link voltage dynamics on transient stability of VSGs. First, two typical kinds of VSGs with dc-link voltage controllers are introduced. Then, mathematical models considering dc-link dynamics are established and the effect of dc-link voltage controllers on transient synchronization stability of VSGs is revealed through equal area criterion (EAC). It is found that dc-link voltage controller would reduce stability margin of VSGs and design-oriented transient stability analysis is carried out quantitively using critical clearing time (CCT). Finally, simulation results are given to validate correctness of theoretical analysis.展开更多
基金supported by theMajor Science and Technology Projects of China Southern Power Grid(Grant number CGYKJXM20210328).
文摘As the penetration rate of distributed energy increases,the transient power angle stability problem of the virtual synchronous generator(VSG)has gradually become prominent.In view of the situation that the grid impedance ratio(R/X)is high and affects the transient power angle stability of VSG,this paper proposes a VSG transient power angle stability control strategy based on the combination of frequency difference feedback and virtual impedance.To improve the transient power angle stability of the VSG,a virtual impedance is adopted in the voltage loop to adjust the impedance ratio R/X;and the PI control feedback of the VSG frequency difference is introduced in the reactive powervoltage link of theVSGto enhance the damping effect.Thesecond-orderVSGdynamic nonlinearmodel considering the reactive power-voltage loop is established and the influence of different proportional integral(PI)control parameters on the system balance stability is analyzed.Moreover,the impact of the impedance ratio R/X on the transient power angle stability is presented using the equal area criterion.In the simulations,during the voltage dips with the reduction of R/X from 1.6 to 0.8,Δδ_(1)is reduced from 0.194 rad to 0.072 rad,Δf_(1)is reduced from 0.170 to 0.093 Hz,which shows better transient power angle stability.Simulation results verify that compared with traditional VSG,the proposedmethod can effectively improve the transient power angle stability of the system.
基金supported in part by National Natural Science Foundation of China(grant No.52207190)Funds for International Cooperation and Exchange of the National Natural Science Foundation of China(No.52061635104)。
文摘Virtual synchronous control has been widely studied for the advantages of emulating inertia for voltage source converters (VSCs). A constant dc-link voltage is usually assumed in existing literature to estimate transient stability of virtual synchronous generators (VSGs). However, actual power supply in the dc-side of VSGs is limited and different dc-link voltage controllers are needed to achieve power balance between DC side and AC side. Addition of dc-link voltage controller has great influence on transient behavior of VSGs, which has not been investigated by previous research. To fill this gap, this paper gives insights into the effect of dc-link voltage dynamics on transient stability of VSGs. First, two typical kinds of VSGs with dc-link voltage controllers are introduced. Then, mathematical models considering dc-link dynamics are established and the effect of dc-link voltage controllers on transient synchronization stability of VSGs is revealed through equal area criterion (EAC). It is found that dc-link voltage controller would reduce stability margin of VSGs and design-oriented transient stability analysis is carried out quantitively using critical clearing time (CCT). Finally, simulation results are given to validate correctness of theoretical analysis.