As the penetration rate of distributed energy increases,the transient power angle stability problem of the virtual synchronous generator(VSG)has gradually become prominent.In view of the situation that the grid impeda...As the penetration rate of distributed energy increases,the transient power angle stability problem of the virtual synchronous generator(VSG)has gradually become prominent.In view of the situation that the grid impedance ratio(R/X)is high and affects the transient power angle stability of VSG,this paper proposes a VSG transient power angle stability control strategy based on the combination of frequency difference feedback and virtual impedance.To improve the transient power angle stability of the VSG,a virtual impedance is adopted in the voltage loop to adjust the impedance ratio R/X;and the PI control feedback of the VSG frequency difference is introduced in the reactive powervoltage link of theVSGto enhance the damping effect.Thesecond-orderVSGdynamic nonlinearmodel considering the reactive power-voltage loop is established and the influence of different proportional integral(PI)control parameters on the system balance stability is analyzed.Moreover,the impact of the impedance ratio R/X on the transient power angle stability is presented using the equal area criterion.In the simulations,during the voltage dips with the reduction of R/X from 1.6 to 0.8,Δδ_(1)is reduced from 0.194 rad to 0.072 rad,Δf_(1)is reduced from 0.170 to 0.093 Hz,which shows better transient power angle stability.Simulation results verify that compared with traditional VSG,the proposedmethod can effectively improve the transient power angle stability of the system.展开更多
The traditional transient stability assessment(TSA)model for power systems has three disadvantages:capturing critical information during faults is difficult,aperiodic and oscillatory unstable conditions are not distin...The traditional transient stability assessment(TSA)model for power systems has three disadvantages:capturing critical information during faults is difficult,aperiodic and oscillatory unstable conditions are not distinguished,and poor generalizability is exhibited by systems with high renewable energy penetration.To address these issues,a novel ResGRU architecture for TSA is proposed in this study.First,a residual neural network(ResNet)is used for deep feature extraction of transient information.Second,a bidirectional gated recurrent unit combined with a multi-attention mechanism(BiGRU-Attention)is used to establish temporal feature dependencies.Their combination constitutes a TSA framework based on the ResGRU architecture.This method predicts three transient conditions:oscillatory instability,aperiodic instability,and stability.The model was trained offline using stochastic gradient descent with a thermal restart(SGDR)optimization algorithm in the offline training phase.This significantly improves the generalizability of the model.Finally,simulation tests on IEEE 145-bus and 39-bus systems confirmed that the proposed method has higher adaptability,accuracy,scalability,and rapidity than the conventional TSA approach.The proposed model also has superior robustness for PMU incomplete configurations,PMU noisy data,and packet loss.展开更多
Transient stability assessment(TSA)based on artificial intelligence typically has two distinct model management approaches:a unified management approach for all faulted lines and a separate management approach for eac...Transient stability assessment(TSA)based on artificial intelligence typically has two distinct model management approaches:a unified management approach for all faulted lines and a separate management approach for each faulted line.To address the shortcomings of the aforementioned approaches,namely accuracy,training time,and model management complexity,a multi-model management approach for power system TSA based on multi-moment feature clustering has been proposed.First,the steady-state and transient features present under fault conditions were obtained through a transient simulation of line faults.The input sample set was then constructed using the aforementioned multi-moment electrical features and the embedded faulty line numbers.Subsequently,K-means clustering was conducted on each line based on the similarity of their electrical features,employing t-SNE dimensionality reduction.The PSO-CNN model was trained separately for each cluster to generate several independent TSA models.Finally,a model effectiveness evaluation system consisting of five metrics was established,and the effect of the sample imbalance ratio on the model effectiveness was investigated.The model effectiveness was evaluated using the IEEE 39-bus system algorithm.The results showed that the multi-model management strategy based on multi-moment feature clustering can effectively combine the two advantages of superior evaluation performance and streamlined model management by fully extracting system features.Moreover,this approach allows for more flexible adjustments to line topology changes.展开更多
With the continuous expansion and increasing complexity of power system scales,the binary classifica-tion for transient stability assessment in power systems can no longer meet the safety requirements of power system ...With the continuous expansion and increasing complexity of power system scales,the binary classifica-tion for transient stability assessment in power systems can no longer meet the safety requirements of power system control and regulation.Therefore,this paper proposes a multi-class transient stability assessment model based on an improved Transformer.The model is designed with a dual-tower encoder structure:one encoder focuses on the time dependency of data,while the other focuses on the dynamic correlations between variables.Feature extraction is conducted from both time and variable perspectives to ensure the completeness of the feature extraction process,thereby enhancing the accuracy of multi-class evaluation in power systems.Additionally,this paper introduces a hybrid sampling strategy based on sample boundaries,which addresses the issue of sample imbalance by increasing the number of boundary samples in the minority class and reducing the number of non-boundary samples in the majority class.Considering the frequent changes in power grid topology or operation modes,this paper proposes a two-stage updating scheme based on self-supervised learning:In the first stage,self-supervised learning is employed to mine the structural information from unlabeled data in the target domain,enhancing the model’s generalization capability in new scenarios.In the second stage,a sample screening mechanism is used to select key samples,which are labeled through long-term simulation techniques for fine-tuning the model parameters.This allows for rapid model updates without relying on many labeled samples.This paper’s proposed model and update scheme have been simulated and verified on two node systems,the IEEE New England 10-machine 39-bus system and the IEEE 47-machine 140-bus system,demonstrating their effectiveness and reliability.展开更多
This paper proposes a novel framework that enables the simultaneous coordination of the controllers of doubly fed induction generators(DFIGs) and synchronous generators(SGs).The proposed coordination approach is based...This paper proposes a novel framework that enables the simultaneous coordination of the controllers of doubly fed induction generators(DFIGs) and synchronous generators(SGs).The proposed coordination approach is based on the zero dynamics method aims at enhancing the transient stability of multi-machine power systems under a wide range of operating conditions. The proposed approach was implemented to the IEEE39-bus power systems. Transient stability margin measured in terms of critical clearing time along with eigenvalue analysis and time domain simulations were considered in the performance assessment. The obtained results were also compared to those achieved using a conventional power system stabilizer/power oscillation(PSS/POD) technique and the interconnection and damping assignment passivity-based controller(IDA-PBC). The performance analysis confirmed the ability of the proposed approach to enhance damping and improve system’s transient stability margin under a wide range of operating conditions.展开更多
As"the third pole",the Tibetan Plateau(TP)is sensitive to climate forcing and has experienced rapid warming in recent decades.This study analyzes annual and seasonal near-surface air temperature changes on t...As"the third pole",the Tibetan Plateau(TP)is sensitive to climate forcing and has experienced rapid warming in recent decades.This study analyzes annual and seasonal near-surface air temperature changes on the TP in response to transient and stabilized 2.0℃/1.5℃global warming targets based on simulations of the Community Earth System Model(CESM).Elevation-dependent warming(EDW)with faster warming at higher elevations is predicted.A surface energy budget analysis is adopted to uncover the mechanisms responsible for the temperature changes.Our results indicate a clear amplified warming on the TP with positive EDW in 2.0℃/1.5℃warmer futures,especially in the cold season.Mean TP warming relative to the reference period(1961–90)is dominated by an enhanced downward longwave radiation flux,while the variations in surface albedo shape the detailed pattern of EDW.For the same global warming level,the temperature changes under transient scenarios are~0.2℃higher than those under stabilized scenarios,and the characteristics of EDW are broadly similar for both scenarios.These differences can be primarily attributed to the combined effects of differential downward longwave radiation,cloud radiative forcing,and surface sensible and latent heat fluxes.These findings contribute to a more detailed understanding of regional climate on the TP in response to the long-term climate goals of the Paris Agreement and highlight the differences between transient and stabilized warming scenarios.展开更多
Based on the complementary advantages of Line Commutated Converter(LCC)and Modular Multilevel Converter(MMC)in power grid applications,there are two types of hybrid DC system topologies:one is the parallel connection ...Based on the complementary advantages of Line Commutated Converter(LCC)and Modular Multilevel Converter(MMC)in power grid applications,there are two types of hybrid DC system topologies:one is the parallel connection of LCC converter stations and MMC converter stations,and the other is the series connection of LCC and MMC converter stations within a single station.The hybrid DC transmission system faces broad application prospects and development potential in large-scale clean energy integration across regions and the construction of a new power system dominated by new energy sources in China.This paper first analyzes the system forms and topological characteristics of hybrid DC transmission,introducing the forms and topological characteristics of converter-level hybrid DC transmission systems and system-level hybrid DC transmission systems.Next,it analyzes the operating characteristics of LCC and MMC inverter-level hybrid DC transmission systems,provides insights into the transient stability of hybrid DC transmission systems,and typical fault ride-through control strategies.Finally,it summarizes the networking characteristics of the LCC-MMC series within the converter station hybrid DC transmission system,studies the transient characteristics and fault ridethrough control strategies under different fault types for the LCC-MMC series in the receiving-end converter station,and investigates the transient characteristics and fault ride-through control strategies under different fault types for the LCC-MMC series in the sending-end converter station.展开更多
The use of an electrical network as close as possible to its limits can lead to its instability in the event of a high amplitude disturbance. The damping of system oscillations can be achieved by conventional means of...The use of an electrical network as close as possible to its limits can lead to its instability in the event of a high amplitude disturbance. The damping of system oscillations can be achieved by conventional means of voltage and speed regulation but also by FACTS (Flexible AC Transmission Systems) devices, which are increasingly used in power networks. In this work, optimal control coordination between a hybrid power flow controller and a three-level inverter was used to improve the transient stability of a transmission line. The UPFC is a combination of a serial compensator (SSSC) and a parallel compensator (STATCOM) both connected to a DC-LINK DC bus. The SSSC acts as a voltage source for the network and injects a voltage that can be adjusted in phase and amplitude in addition to the network voltage;the STATCOM acts as a current source. The approach used is tested in the Matlab Simulink environment on a single machine network. Optimal controller tuning gives a better transient stability improvement by reducing the transport angle oscillations from 248.17% to 9.85%.展开更多
As photovoltaic (PV) capacity in power system increases, the capacity of synchronous generator needs to be reduced relatively. This leads to the lower system inertia and the higher generator reactance, and hence the...As photovoltaic (PV) capacity in power system increases, the capacity of synchronous generator needs to be reduced relatively. This leads to the lower system inertia and the higher generator reactance, and hence the generator transient stability may negatively be affected. In particular, the impact on the transient stability may become more serious when the considerable amounts of PV systems are disconnected simultaneously during voltage sag. In this work, the generator transient stability in the power system with significant PV penetration is assessed by a numerical simulation. In order to assess the impact from various angles, simulation parameters such as levels of PV penetration, variety of power sources (inverter or rotational machine), and existence of LVRT capability are considered. The simulation is performed by using PSCAD/EMTDC software.展开更多
Rainfall, as one of the most significant factors triggering the residual soil slope failure, leads to not only the reduction of soil shear strength, but also the increase of soil weight and the decrease of matric suct...Rainfall, as one of the most significant factors triggering the residual soil slope failure, leads to not only the reduction of soil shear strength, but also the increase of soil weight and the decrease of matric suction as well. All these modifications in soil properties have important influence on the slope stability. The water infiltration and redistribution inside the slope are the preconditions of the slope stability under rainfall conditions. Based on the numerical simulation via finite element method, the water infiltration process under rainfall conditions was studied in the present work. The emphases are the formation, distribution and dissipation of transient saturated zone. As for the calculation parameters, the SWCC and the saturated permeability have been determined by pressure plate test and variable head test respectively. The entire process(formation, development, dissipation) of the transient saturated zone was studied in detail. The variations of volumetric water content, matric suction and hydraulic gradient inside the slope, and the eventually raise of groundwater table were characterized and discussed, too. The results show that the major cause of the formation of transient saturated zone is ascribed to the fact that the exudation velocity of rainwater on the wetting front is less than the infiltration velocity of rainfall; as a result, the water content of the soil increases. On the other hand, the formation and extension of transient saturated zone have a close relationship with rainfall intensity and duration. The results can help the geotechnical engineers for the deeper understanding of the failure of residual slope under rainfall condition. It is also suggested that the proper drainage system in the slope may be the cost-effective slope failure mitigation method.展开更多
With the increasing development of wind power,the scale of wind farms and unit capacity of wind turbines are getting larger and larger,and the impact of wind integration on power systems cannot be ignored.However,in m...With the increasing development of wind power,the scale of wind farms and unit capacity of wind turbines are getting larger and larger,and the impact of wind integration on power systems cannot be ignored.However,in most cases,the areas with a plenty of wind resources do not have strong grid structures.Furthermore,the characteristics of wind power dictate that wind turbines need to absorb reactive power during operation.Because of the strong correlation between voltage stability and systems' reactive power,the impacts of wind integration on voltage stability has become an important issue.Based on the power system simulation software DIgSILENT and combined analysis of actual practice,this paper investigates the impacts of two types of wind farms on voltage stability:namely a type of wind farms which are constituted by constant speed wind turbines based on common induction generators(IG) and another type of wind farms which are constituted by VSCF wind turbines based on doubly-fed induction generators(DFIG).Through investigation the critical fault clearing time is presented for different outputs of wind farms.Moreover,the impacts of static var compensator(SVC) and static synchronous compensator(STATCOM) on transient voltage stability in IG-based wind farms are studied to improve the security and stability of the Jiangsu power grid after the integration of large scale wind power.展开更多
The impact of large-scale grid-connected PV (photovoltaics) on power system transient stability is discussed in this paper. In response to an increase of PV capacity, the capacity of conventional synchronous generat...The impact of large-scale grid-connected PV (photovoltaics) on power system transient stability is discussed in this paper. In response to an increase of PV capacity, the capacity of conventional synchronous generator needs to be reduced relatively. This leads to the lower system inertia and the higher generator reactance, and hence, the power system transient stability may negatively be affected. In particular, the impact on the transient stability may become more serious when the considerable amounts of PV systems are disconnected simultaneously during voltage sag. In this work, the potential impact of significant PV penetration on the transient stability is assessed by a numerical simulation using PSCAD/EMTDC.展开更多
With the integration of a voltage source converter(VSC),having variable internal voltages and source impedance,in a microgrid with high resistance to reactance ratio of short lines,angle-based transient stability tech...With the integration of a voltage source converter(VSC),having variable internal voltages and source impedance,in a microgrid with high resistance to reactance ratio of short lines,angle-based transient stability techniques may find limitations.Under such a situation,the Lyapunov function can be a viable option for transient stability assessment(TSA)of such a VSC-interfaced microgrid.However,the determination of the Lyapunov function with the classical method is very challenging for a microgrid with converter controller dynamics.To overcome such challenges,this paper develops a physics-informed,Lyapunov function-based TSA framework for VSC-interfaced microgrids.The method uses the physics involved and the initial and boundary conditions of the system in learning the Lyapunov functions.This method is tested and validated under faults,droop-coefficient changes,generator outages,and load shedding on a small grid-connected microgrid and the CIGRE microgrid.展开更多
The novel quantitative assessment method using transmission line measurement was developed. A new style of stability criterion was suggested which is based on the line measurement. The stability indices for lines, cut...The novel quantitative assessment method using transmission line measurement was developed. A new style of stability criterion was suggested which is based on the line measurement. The stability indices for lines, cutsets and power system according to features of transient energy in the lines were given, which not only provide a reliable and accurate assessment of the transient stability of power system, but also can be used to assess the effect of lines and cutsets on the transient stability and identify the weak transmission segment. Examples were presented by simulation on the IEEE-39 buses test system.展开更多
The effect of energy on the natural environment has become increasingly severe as human consumption of fossil energy has increased.The capacity of the synchronous generators to keep working without losing synchronizat...The effect of energy on the natural environment has become increasingly severe as human consumption of fossil energy has increased.The capacity of the synchronous generators to keep working without losing synchronization when the system is exposed to severe faults such as short circuits is referred to as the power system’s transient stability.As the power system’s safe and stable operation and mechanism of action become more complicated,higher demands for accurate and rapid power system transient stability analysis are made.Current methods for analyzing transient stability are less accurate because they do not account formisclassification of unstable samples.As a result,this paper proposes a novel approach for analyzing transient stability.The key concept is to use deep forest(DF)and a neighborhood rough reduction approach together.Using the neighborhood rough sets,the original feature space is obtained by creating many optimal feature subsets at various granularity levels.Then,by deploying the DF cascade structure,the mapping connection between the transient stability state and the features is reinforced.The weighted voting technique is used in the learning process to increase the classification accuracy of unstable samples.When contrasted to current methods,simulation results indicate that the proposed approach outperforms them.展开更多
The length of the trajectory is proposed as a function for the employment of the sensitivity analysis method in power system transient stability analysis. Its sensitivity to the faultclearing time is about 10 times hi...The length of the trajectory is proposed as a function for the employment of the sensitivity analysis method in power system transient stability analysis. Its sensitivity to the faultclearing time is about 10 times higher than that of the energy function or the distance function. The integrating time is reduced to less than 3 s while the accuracy is maintained. It can also be used to provide parameter limits. Simulations on the WSCC 4 machine system and the New England system verify the effectiveness of sensitivity of trajectory length in transient stability analysis.展开更多
With the daily expansion of global energy consumption,developing the power grids is of uttermost importance.However,building a new trans-mission line is costly and time-consuming,so utilizing the same lines with possi...With the daily expansion of global energy consumption,developing the power grids is of uttermost importance.However,building a new trans-mission line is costly and time-consuming,so utilizing the same lines with possible higher transmission capacity is very cost-effective.In this regard,to increase the capacity of the transmission lines,the flexible alternating current transmission system(FACTS)has been widely used in power grids in recent years by industrialized countries.One of the essential topics in electrical power systems is the reactive power compensation,and the FACTS plays a significant role in controlling the reactive power current in the power grid and the system voltage oscillations and stability.When a static synchronous compensator(STATCOM)is embedded in a power system to increase the bus voltage,a supplementary damping controller can be designed to enhance the system oscillation damping.Given the expansion of the grids in the power system,the complexity of their optimization and the extraordinary ability of the imperialist competitive algorithm(ICA)for solving such problems,in this paper,the ICA has been used to determine the optimal position and size of the FACTS devices.展开更多
The data-driven transient stability assessment(TSA)of power systems can predict online real-time prediction by learning the temporal features before and after faults.However,the accuracy of the assessment is limited b...The data-driven transient stability assessment(TSA)of power systems can predict online real-time prediction by learning the temporal features before and after faults.However,the accuracy of the assessment is limited by the quality of the data and has weak transferability.Based on this,this paper proposes a method for TSA of power systems based on an improved extreme gradient boosting(XGBoost)model.Firstly,the gradient detection method is employed to remove noise interference while maintaining the original time series trend.On this basis,a focal loss function is introduced to guide the training of theXGBoostmodel,enhancing the deep exploration of minority class samples to improve the accuracy of the model evaluation.Furthermore,to improve the generalization ability of the evaluation model,a transfer learning method based on model parameters and sample augmentation is proposed.The simulation analysis on the IEEE 39-bus system demonstrates that the proposed method,compared to the traditional machine learning-based transient stability assessment approach,achieves an average improvement of 2.16%in evaluation accuracy.Specifically,under scenarios involving changes in topology structure and operating conditions,the accuracy is enhanced by 3.65%and 3.11%,respectively.Moreover,the model updating efficiency is enhanced by 14–15 times,indicating the model’s transferable and adaptive capabilities across multiple scenarios.展开更多
The impact of large-scale grid-connected renewable power sources, such as wind generators and solar photovoitaic systems, on transient stability of synchronous generators is discussed in this paper. The permanent magn...The impact of large-scale grid-connected renewable power sources, such as wind generators and solar photovoitaic systems, on transient stability of synchronous generators is discussed in this paper. The permanent magnet synchronous generator with variable speed wind turbine is used in the simulation analysis as a wind generator model. The transient stability analysis is performed for IEEE 9-bus system model with high-penetration renewable power sources. The effect of FRT (fault ride-through) capability implemented for each power source on the transient stability is investigated.展开更多
In the previous paper [1], the transient stability of synchronous generator in power system with high-penetration PV (photovoltaic) was assessed by simulation analysis of a single-machine infinite-bus system model. ...In the previous paper [1], the transient stability of synchronous generator in power system with high-penetration PV (photovoltaic) was assessed by simulation analysis of a single-machine infinite-bus system model. Through the simulation analysis, we have obtained some conclusions in terms of the impact of high-penetration PV on the stability. However, for more accurate assessment of the transient stability, it is necessary to analyze various simulation models considering many other power system conditions. This paper presents the results of the analysis for the transient stability simulation performed for IEEE 9-bus system model, in which the effects of various conditions, such as variety of power sources (inverter or rotational machine), load characteristics, existence of LVRT (low-voltage ride-through) capability and fault locations, on the transient stability are investigated.展开更多
基金supported by theMajor Science and Technology Projects of China Southern Power Grid(Grant number CGYKJXM20210328).
文摘As the penetration rate of distributed energy increases,the transient power angle stability problem of the virtual synchronous generator(VSG)has gradually become prominent.In view of the situation that the grid impedance ratio(R/X)is high and affects the transient power angle stability of VSG,this paper proposes a VSG transient power angle stability control strategy based on the combination of frequency difference feedback and virtual impedance.To improve the transient power angle stability of the VSG,a virtual impedance is adopted in the voltage loop to adjust the impedance ratio R/X;and the PI control feedback of the VSG frequency difference is introduced in the reactive powervoltage link of theVSGto enhance the damping effect.Thesecond-orderVSGdynamic nonlinearmodel considering the reactive power-voltage loop is established and the influence of different proportional integral(PI)control parameters on the system balance stability is analyzed.Moreover,the impact of the impedance ratio R/X on the transient power angle stability is presented using the equal area criterion.In the simulations,during the voltage dips with the reduction of R/X from 1.6 to 0.8,Δδ_(1)is reduced from 0.194 rad to 0.072 rad,Δf_(1)is reduced from 0.170 to 0.093 Hz,which shows better transient power angle stability.Simulation results verify that compared with traditional VSG,the proposedmethod can effectively improve the transient power angle stability of the system.
基金financially supported by State Key Laboratory of HVDC No.SKLHVDC-2023-KF-03.
文摘The traditional transient stability assessment(TSA)model for power systems has three disadvantages:capturing critical information during faults is difficult,aperiodic and oscillatory unstable conditions are not distinguished,and poor generalizability is exhibited by systems with high renewable energy penetration.To address these issues,a novel ResGRU architecture for TSA is proposed in this study.First,a residual neural network(ResNet)is used for deep feature extraction of transient information.Second,a bidirectional gated recurrent unit combined with a multi-attention mechanism(BiGRU-Attention)is used to establish temporal feature dependencies.Their combination constitutes a TSA framework based on the ResGRU architecture.This method predicts three transient conditions:oscillatory instability,aperiodic instability,and stability.The model was trained offline using stochastic gradient descent with a thermal restart(SGDR)optimization algorithm in the offline training phase.This significantly improves the generalizability of the model.Finally,simulation tests on IEEE 145-bus and 39-bus systems confirmed that the proposed method has higher adaptability,accuracy,scalability,and rapidity than the conventional TSA approach.The proposed model also has superior robustness for PMU incomplete configurations,PMU noisy data,and packet loss.
基金supported by the Science and Technology Project of SGCC(5100-202199558A-0-5-ZN).
文摘Transient stability assessment(TSA)based on artificial intelligence typically has two distinct model management approaches:a unified management approach for all faulted lines and a separate management approach for each faulted line.To address the shortcomings of the aforementioned approaches,namely accuracy,training time,and model management complexity,a multi-model management approach for power system TSA based on multi-moment feature clustering has been proposed.First,the steady-state and transient features present under fault conditions were obtained through a transient simulation of line faults.The input sample set was then constructed using the aforementioned multi-moment electrical features and the embedded faulty line numbers.Subsequently,K-means clustering was conducted on each line based on the similarity of their electrical features,employing t-SNE dimensionality reduction.The PSO-CNN model was trained separately for each cluster to generate several independent TSA models.Finally,a model effectiveness evaluation system consisting of five metrics was established,and the effect of the sample imbalance ratio on the model effectiveness was investigated.The model effectiveness was evaluated using the IEEE 39-bus system algorithm.The results showed that the multi-model management strategy based on multi-moment feature clustering can effectively combine the two advantages of superior evaluation performance and streamlined model management by fully extracting system features.Moreover,this approach allows for more flexible adjustments to line topology changes.
基金the National Natural Science Foundation of China(5227-7084).
文摘With the continuous expansion and increasing complexity of power system scales,the binary classifica-tion for transient stability assessment in power systems can no longer meet the safety requirements of power system control and regulation.Therefore,this paper proposes a multi-class transient stability assessment model based on an improved Transformer.The model is designed with a dual-tower encoder structure:one encoder focuses on the time dependency of data,while the other focuses on the dynamic correlations between variables.Feature extraction is conducted from both time and variable perspectives to ensure the completeness of the feature extraction process,thereby enhancing the accuracy of multi-class evaluation in power systems.Additionally,this paper introduces a hybrid sampling strategy based on sample boundaries,which addresses the issue of sample imbalance by increasing the number of boundary samples in the minority class and reducing the number of non-boundary samples in the majority class.Considering the frequent changes in power grid topology or operation modes,this paper proposes a two-stage updating scheme based on self-supervised learning:In the first stage,self-supervised learning is employed to mine the structural information from unlabeled data in the target domain,enhancing the model’s generalization capability in new scenarios.In the second stage,a sample screening mechanism is used to select key samples,which are labeled through long-term simulation techniques for fine-tuning the model parameters.This allows for rapid model updates without relying on many labeled samples.This paper’s proposed model and update scheme have been simulated and verified on two node systems,the IEEE New England 10-machine 39-bus system and the IEEE 47-machine 140-bus system,demonstrating their effectiveness and reliability.
文摘This paper proposes a novel framework that enables the simultaneous coordination of the controllers of doubly fed induction generators(DFIGs) and synchronous generators(SGs).The proposed coordination approach is based on the zero dynamics method aims at enhancing the transient stability of multi-machine power systems under a wide range of operating conditions. The proposed approach was implemented to the IEEE39-bus power systems. Transient stability margin measured in terms of critical clearing time along with eigenvalue analysis and time domain simulations were considered in the performance assessment. The obtained results were also compared to those achieved using a conventional power system stabilizer/power oscillation(PSS/POD) technique and the interconnection and damping assignment passivity-based controller(IDA-PBC). The performance analysis confirmed the ability of the proposed approach to enhance damping and improve system’s transient stability margin under a wide range of operating conditions.
基金the National Natural Science Foundation of China(Grant Nos.41971072,41771069).
文摘As"the third pole",the Tibetan Plateau(TP)is sensitive to climate forcing and has experienced rapid warming in recent decades.This study analyzes annual and seasonal near-surface air temperature changes on the TP in response to transient and stabilized 2.0℃/1.5℃global warming targets based on simulations of the Community Earth System Model(CESM).Elevation-dependent warming(EDW)with faster warming at higher elevations is predicted.A surface energy budget analysis is adopted to uncover the mechanisms responsible for the temperature changes.Our results indicate a clear amplified warming on the TP with positive EDW in 2.0℃/1.5℃warmer futures,especially in the cold season.Mean TP warming relative to the reference period(1961–90)is dominated by an enhanced downward longwave radiation flux,while the variations in surface albedo shape the detailed pattern of EDW.For the same global warming level,the temperature changes under transient scenarios are~0.2℃higher than those under stabilized scenarios,and the characteristics of EDW are broadly similar for both scenarios.These differences can be primarily attributed to the combined effects of differential downward longwave radiation,cloud radiative forcing,and surface sensible and latent heat fluxes.These findings contribute to a more detailed understanding of regional climate on the TP in response to the long-term climate goals of the Paris Agreement and highlight the differences between transient and stabilized warming scenarios.
基金supported by the Joint Research Fund in Smart Grid(U23B20120)under cooperative agreement between the National Natural Science Foundation of China and State Grid Corporation of China。
文摘Based on the complementary advantages of Line Commutated Converter(LCC)and Modular Multilevel Converter(MMC)in power grid applications,there are two types of hybrid DC system topologies:one is the parallel connection of LCC converter stations and MMC converter stations,and the other is the series connection of LCC and MMC converter stations within a single station.The hybrid DC transmission system faces broad application prospects and development potential in large-scale clean energy integration across regions and the construction of a new power system dominated by new energy sources in China.This paper first analyzes the system forms and topological characteristics of hybrid DC transmission,introducing the forms and topological characteristics of converter-level hybrid DC transmission systems and system-level hybrid DC transmission systems.Next,it analyzes the operating characteristics of LCC and MMC inverter-level hybrid DC transmission systems,provides insights into the transient stability of hybrid DC transmission systems,and typical fault ride-through control strategies.Finally,it summarizes the networking characteristics of the LCC-MMC series within the converter station hybrid DC transmission system,studies the transient characteristics and fault ridethrough control strategies under different fault types for the LCC-MMC series in the receiving-end converter station,and investigates the transient characteristics and fault ride-through control strategies under different fault types for the LCC-MMC series in the sending-end converter station.
文摘The use of an electrical network as close as possible to its limits can lead to its instability in the event of a high amplitude disturbance. The damping of system oscillations can be achieved by conventional means of voltage and speed regulation but also by FACTS (Flexible AC Transmission Systems) devices, which are increasingly used in power networks. In this work, optimal control coordination between a hybrid power flow controller and a three-level inverter was used to improve the transient stability of a transmission line. The UPFC is a combination of a serial compensator (SSSC) and a parallel compensator (STATCOM) both connected to a DC-LINK DC bus. The SSSC acts as a voltage source for the network and injects a voltage that can be adjusted in phase and amplitude in addition to the network voltage;the STATCOM acts as a current source. The approach used is tested in the Matlab Simulink environment on a single machine network. Optimal controller tuning gives a better transient stability improvement by reducing the transport angle oscillations from 248.17% to 9.85%.
文摘As photovoltaic (PV) capacity in power system increases, the capacity of synchronous generator needs to be reduced relatively. This leads to the lower system inertia and the higher generator reactance, and hence the generator transient stability may negatively be affected. In particular, the impact on the transient stability may become more serious when the considerable amounts of PV systems are disconnected simultaneously during voltage sag. In this work, the generator transient stability in the power system with significant PV penetration is assessed by a numerical simulation. In order to assess the impact from various angles, simulation parameters such as levels of PV penetration, variety of power sources (inverter or rotational machine), and existence of LVRT capability are considered. The simulation is performed by using PSCAD/EMTDC software.
基金Projects(51508040,51578079,51678074,51678073)supported by the National Natural Science Foundation of ChinaProject(KFJ160601)supported by the Open Fund of Engineering Laboratory of Spatial Information Technology of Highway Geological Disaster Early Warning in Hunan Province(Changsha University of Science and Technology),China
文摘Rainfall, as one of the most significant factors triggering the residual soil slope failure, leads to not only the reduction of soil shear strength, but also the increase of soil weight and the decrease of matric suction as well. All these modifications in soil properties have important influence on the slope stability. The water infiltration and redistribution inside the slope are the preconditions of the slope stability under rainfall conditions. Based on the numerical simulation via finite element method, the water infiltration process under rainfall conditions was studied in the present work. The emphases are the formation, distribution and dissipation of transient saturated zone. As for the calculation parameters, the SWCC and the saturated permeability have been determined by pressure plate test and variable head test respectively. The entire process(formation, development, dissipation) of the transient saturated zone was studied in detail. The variations of volumetric water content, matric suction and hydraulic gradient inside the slope, and the eventually raise of groundwater table were characterized and discussed, too. The results show that the major cause of the formation of transient saturated zone is ascribed to the fact that the exudation velocity of rainwater on the wetting front is less than the infiltration velocity of rainfall; as a result, the water content of the soil increases. On the other hand, the formation and extension of transient saturated zone have a close relationship with rainfall intensity and duration. The results can help the geotechnical engineers for the deeper understanding of the failure of residual slope under rainfall condition. It is also suggested that the proper drainage system in the slope may be the cost-effective slope failure mitigation method.
文摘With the increasing development of wind power,the scale of wind farms and unit capacity of wind turbines are getting larger and larger,and the impact of wind integration on power systems cannot be ignored.However,in most cases,the areas with a plenty of wind resources do not have strong grid structures.Furthermore,the characteristics of wind power dictate that wind turbines need to absorb reactive power during operation.Because of the strong correlation between voltage stability and systems' reactive power,the impacts of wind integration on voltage stability has become an important issue.Based on the power system simulation software DIgSILENT and combined analysis of actual practice,this paper investigates the impacts of two types of wind farms on voltage stability:namely a type of wind farms which are constituted by constant speed wind turbines based on common induction generators(IG) and another type of wind farms which are constituted by VSCF wind turbines based on doubly-fed induction generators(DFIG).Through investigation the critical fault clearing time is presented for different outputs of wind farms.Moreover,the impacts of static var compensator(SVC) and static synchronous compensator(STATCOM) on transient voltage stability in IG-based wind farms are studied to improve the security and stability of the Jiangsu power grid after the integration of large scale wind power.
文摘The impact of large-scale grid-connected PV (photovoltaics) on power system transient stability is discussed in this paper. In response to an increase of PV capacity, the capacity of conventional synchronous generator needs to be reduced relatively. This leads to the lower system inertia and the higher generator reactance, and hence, the power system transient stability may negatively be affected. In particular, the impact on the transient stability may become more serious when the considerable amounts of PV systems are disconnected simultaneously during voltage sag. In this work, the potential impact of significant PV penetration on the transient stability is assessed by a numerical simulation using PSCAD/EMTDC.
基金supported by the National Science Foundation under Grant No.ITE-2134840This work relates to the Department of Navy award N00014-23-1-2124 issued by the Office of Naval Research.The United States Government has a royalty-free license worldwide for all copyrightable material contained herein。
文摘With the integration of a voltage source converter(VSC),having variable internal voltages and source impedance,in a microgrid with high resistance to reactance ratio of short lines,angle-based transient stability techniques may find limitations.Under such a situation,the Lyapunov function can be a viable option for transient stability assessment(TSA)of such a VSC-interfaced microgrid.However,the determination of the Lyapunov function with the classical method is very challenging for a microgrid with converter controller dynamics.To overcome such challenges,this paper develops a physics-informed,Lyapunov function-based TSA framework for VSC-interfaced microgrids.The method uses the physics involved and the initial and boundary conditions of the system in learning the Lyapunov functions.This method is tested and validated under faults,droop-coefficient changes,generator outages,and load shedding on a small grid-connected microgrid and the CIGRE microgrid.
基金National Natural Science Foundation ofChina( No.5 99770 0 1)
文摘The novel quantitative assessment method using transmission line measurement was developed. A new style of stability criterion was suggested which is based on the line measurement. The stability indices for lines, cutsets and power system according to features of transient energy in the lines were given, which not only provide a reliable and accurate assessment of the transient stability of power system, but also can be used to assess the effect of lines and cutsets on the transient stability and identify the weak transmission segment. Examples were presented by simulation on the IEEE-39 buses test system.
基金The authors extend their appreciation to the Deanship of Scientific Research at Jouf University for funding this work through research Grant No.(DSR-2021-02-0113).
文摘The effect of energy on the natural environment has become increasingly severe as human consumption of fossil energy has increased.The capacity of the synchronous generators to keep working without losing synchronization when the system is exposed to severe faults such as short circuits is referred to as the power system’s transient stability.As the power system’s safe and stable operation and mechanism of action become more complicated,higher demands for accurate and rapid power system transient stability analysis are made.Current methods for analyzing transient stability are less accurate because they do not account formisclassification of unstable samples.As a result,this paper proposes a novel approach for analyzing transient stability.The key concept is to use deep forest(DF)and a neighborhood rough reduction approach together.Using the neighborhood rough sets,the original feature space is obtained by creating many optimal feature subsets at various granularity levels.Then,by deploying the DF cascade structure,the mapping connection between the transient stability state and the features is reinforced.The weighted voting technique is used in the learning process to increase the classification accuracy of unstable samples.When contrasted to current methods,simulation results indicate that the proposed approach outperforms them.
基金Supported by the National Natural Science Foundation of China (60474018)
文摘The length of the trajectory is proposed as a function for the employment of the sensitivity analysis method in power system transient stability analysis. Its sensitivity to the faultclearing time is about 10 times higher than that of the energy function or the distance function. The integrating time is reduced to less than 3 s while the accuracy is maintained. It can also be used to provide parameter limits. Simulations on the WSCC 4 machine system and the New England system verify the effectiveness of sensitivity of trajectory length in transient stability analysis.
基金This work was supported in part by an International Research Partnership“Electrical Engineering-Thai French Research Center(EE-TFRC)”under the project framework of the Lorraine Universited’Excellence(LUE)in cooperation between Universitede Lorraine and King Mongkut’s University of Technology North Bangkok and in part by the National Research Council of Thailand(NRCT)under Senior Research Scholar Program under Grant No.N42A640328.
文摘With the daily expansion of global energy consumption,developing the power grids is of uttermost importance.However,building a new trans-mission line is costly and time-consuming,so utilizing the same lines with possible higher transmission capacity is very cost-effective.In this regard,to increase the capacity of the transmission lines,the flexible alternating current transmission system(FACTS)has been widely used in power grids in recent years by industrialized countries.One of the essential topics in electrical power systems is the reactive power compensation,and the FACTS plays a significant role in controlling the reactive power current in the power grid and the system voltage oscillations and stability.When a static synchronous compensator(STATCOM)is embedded in a power system to increase the bus voltage,a supplementary damping controller can be designed to enhance the system oscillation damping.Given the expansion of the grids in the power system,the complexity of their optimization and the extraordinary ability of the imperialist competitive algorithm(ICA)for solving such problems,in this paper,the ICA has been used to determine the optimal position and size of the FACTS devices.
基金This work is supported by the State Grid Shanxi Electric Power Company Technology Project(52053023000B).
文摘The data-driven transient stability assessment(TSA)of power systems can predict online real-time prediction by learning the temporal features before and after faults.However,the accuracy of the assessment is limited by the quality of the data and has weak transferability.Based on this,this paper proposes a method for TSA of power systems based on an improved extreme gradient boosting(XGBoost)model.Firstly,the gradient detection method is employed to remove noise interference while maintaining the original time series trend.On this basis,a focal loss function is introduced to guide the training of theXGBoostmodel,enhancing the deep exploration of minority class samples to improve the accuracy of the model evaluation.Furthermore,to improve the generalization ability of the evaluation model,a transfer learning method based on model parameters and sample augmentation is proposed.The simulation analysis on the IEEE 39-bus system demonstrates that the proposed method,compared to the traditional machine learning-based transient stability assessment approach,achieves an average improvement of 2.16%in evaluation accuracy.Specifically,under scenarios involving changes in topology structure and operating conditions,the accuracy is enhanced by 3.65%and 3.11%,respectively.Moreover,the model updating efficiency is enhanced by 14–15 times,indicating the model’s transferable and adaptive capabilities across multiple scenarios.
文摘The impact of large-scale grid-connected renewable power sources, such as wind generators and solar photovoitaic systems, on transient stability of synchronous generators is discussed in this paper. The permanent magnet synchronous generator with variable speed wind turbine is used in the simulation analysis as a wind generator model. The transient stability analysis is performed for IEEE 9-bus system model with high-penetration renewable power sources. The effect of FRT (fault ride-through) capability implemented for each power source on the transient stability is investigated.
文摘In the previous paper [1], the transient stability of synchronous generator in power system with high-penetration PV (photovoltaic) was assessed by simulation analysis of a single-machine infinite-bus system model. Through the simulation analysis, we have obtained some conclusions in terms of the impact of high-penetration PV on the stability. However, for more accurate assessment of the transient stability, it is necessary to analyze various simulation models considering many other power system conditions. This paper presents the results of the analysis for the transient stability simulation performed for IEEE 9-bus system model, in which the effects of various conditions, such as variety of power sources (inverter or rotational machine), load characteristics, existence of LVRT (low-voltage ride-through) capability and fault locations, on the transient stability are investigated.